VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421



Similar documents
OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Light Meter (Foot Candles)

DISSOLVED OXYGEN METER Model : DO-5509

GSM HOME SECURITY SYSTEM

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Current Monitoring Kit

DC Electronic Loads 8500 series

Voltech DC1000. Precision DC Bias Current Source

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Modular I/O System Analog and Digital Interface Modules

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Ground Resistance Clamp On Tester

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

4-Channel Thermometer / Datalogger

Wahl C50 Calibrator FEATURES

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

AutoRanging Digital MultiMeter

Current Monitoring Kit QUICK START GUIDE

Hand-held thermometer Model CTH7000

Quick Connect. quick - simple - efficient.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Duct Humidity Transmitter

Drayton Digistat +2RF/+3RF

Contents. Document information

User Guide. Model Insulation Tester / Megohmmeter

Product Information Sheet UH28CS-12kV Hi Pot Tester

LT-82 Stationary IR Transmitter

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Kit Watt Audio Amplifier

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE


Physical Specifications (Custom design available.)

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Turbo X channel UHF true diversity

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

Digital Pressure Measuring Instrument MDR480

Temperature & Humidity SMS Alert Controller

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

1. SAFETY INFORMATION

Combi B Alarm box. Mounting instructions

T0118 T2118 T3118. Instruction Manual

User's Guide. True RMS Industrial Multimeter

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

iva Cable & Antenna Analyzer

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

4.3-inch Back-Up Camera

TS-770 SERIES CONFERENCE SYSTEM

Absolute Rotary Encoder E6CP

iva Cable & Antenna Analyzer

Physics 3330 Experiment #2 Fall DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Research RF Sputtering Packages

FREJA 300 Relay Testing System

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

T Substation Maintenance and Commissioning Test Equipment

Electronic Pressure Switch EDS 300

Ground Resistance Clamp-On Tester

magnetronic GmbH Kreuzhofstr München Tel.: 089/ Fax: 089/ Battery control system DCC 6000

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Solid-State Timer H3G

Voltage Regulator SPAU 341 C. Product Guide

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

Model UT713 OPERATING MANUAL

12 Volt 30 Amp Digital Solar Charge Controller

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Vario-Series Accessories

Installation Manual for D0700 ISDN Analogue Converter

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Loop Calibration and Maintenance

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Integrating Sound Level Meter and Datalogger

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

DCS Input/Output Relay Card Series

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

Model UT33A: OPERATING MANUAL Table of Contents (1)

Handheld portable appliance testers

1.44 kw Programmable DC Power Supplies XLN Series

SC8108-A. NetWork Cable Tester. User Operation Manual. Taking Its Source At Sanling Science & Technology Good helper to network

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

THE KW107 SUPERMATCH ATU manual, courtesy of Barry G0DWZ

Manual Ranging MultiMeter

UT202A Operating Manual. Contents

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

Multifunction Process Calibrator

Transcription:

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1 Display... 4 3-2 Function Switch... 4 3-3 Power Switch...4 3-4 Range Switch...4 3-5 Calibration Adjust knob...4 3-6 Battery Compartment/Cover... 4 3-7 Input Socket... 4 3-8 Cable Plug...4 3-9 Alligator Clips... 4 4. MEASURING PROCEDURE... 5 4-1 Current source... 5 4-2 Current measurement... 5 4-3 Power and current measurement of two wire loop... 6 4-4 DC mv source... 7 5. REPLACEMENT OF BATTERY... 8

1. FEATURES * Portable instrument for calibrating process devices and measuring process signals. * Adjustable 0-24 ma current source. * Adjustable -199.9 mv to +199.9 mv DCV source. * Current calibrator drives loads up to 500 ohms. * The instruments can power as well as measure a two-wire current loop, useful for testing 4-20mA loop devices ( for example pressure transmitters). * Four functions include: 1) Precision current source 2) Measurement of current signal 3) Simultaneous powering and measurement of a 2-wire current loop 4)Precision DC mv source, 2. SPECIFICATIONS 2-1 General Specifications Display LCD display, max. display count 1999. 13 mm ( 0.5" ) digit height. Function 1) Current source : Range & 2 ranges : Resolution 0-19.99 ma x 0.01 ma 0-24 ma x 0.1 ma 2) Current measurement : 2 ranges : 0-19.99 ma x 0.01 ma 0-24 ma x 0.1 ma 3) Power and current measurement of two wire loop : 0-19.99 ma x 0.01 ma 0-24 ma x 0.1 ma 4) DC mv source : - 199.9 mv to + 199.9 mv x 0.1 mv 1

Sampling Approx. 0.4 second. Time Over input Indication of " 1 ". Indication Operating 0 to 50 ( 32 to 122 ). Temperature Operating Less than 80% RH. Humidity Power Supply 006P DC 9V, MN1604/PP3 battery or equivalent. Alkaline type or heavy duty type. Power Current measurement : Consumption Approx. DC 12 ma Power and current measurement : Approx. DC 12 ma Current source (under 10 ma signal out put) : Approx. DC 33 ma DC mv source (under 100 mv signal out put) : Approx. DC 33 ma Dimension 185 x 78 x 38 mm ( 7.3 x 3.0 x 1.5 inch ). Weight 265 g/0.58 LB ( incluing battery ). Accessories Operational manual... 1 PC. Included Cable with the alligator pairs ( red & black ), LN-TL421... 1 PC. 2-2 Electrical Specifications (23 5 ) Current source Range Display Accuracy Resolution 0-19.99 ma 0.01 ma ± ( 0.25 % FS + 1 d ) 0-24 ma 0.1 ma ± ( 0.5 % FS + 1 d ) * Output 0 to 24 ma current for loads up to 500 ohms. Output > 20 ma current for loads up to 400 ohms. * FS : full scale 2

Current measurement Range Display Accuracy Resolution 0-19.99 ma 0.01 ma ± ( 0.25 % FS + 1 d ) 0-24 ma 0.1 ma ± ( 0.5 % FS + 1 d ) * FS : full scale Power and current measurement of two wire loop Range Display Accuracy Resolution 0-19.99 ma 0.01 ma ± ( 0.25 % FS + 1 d ) 0-24 ma 0.1 ma ± ( 0.5 % FS + 1 d ) * Provides power DC 12V 2 V to the loop and measures current. * FS : full scale DC mv source Range Display Accuracy Resolution - 199.9 mv 0.1 mv ± ( 0.25 % FS + 1 d ) to + 199.9 mv * Output measured load impedance should > 1 K ohms. * FS : full scale Remark : The above specification are tested under the environment RF Field Strength less than 3 V/M & frequency less than the 30 MHz only. 3

3. FRONT PANEL DESCRIPTION Fig. 1 3-1 Display 3-2 Function Switch 3-3 Power Switch Symbol 1 = On 0 = Off 3-4 Range Switch 3-5 Calibration Adjust knob 3-6 Battery Compartment/Cover 3-7 Input Socket 3-8 Cable Plug 3-9 Alligator Clips 4

4. MEASURING PROCEDURE 4-1 Current source 1) Install the " Cable Plug " ( 3-8, Fig. 1 ) into the " Input Socket " ( 3-7, Fig. 1 ). 2) Slide the " Function Switch " ( 3-2, Fig. 1 ) to the " CURRENT SOURCE " position. 3) Slide the " Range Switch " ( 3-4, Fig. 1 ) to " 0-19.99 ma " position for getting the 0.01 ma display resolution ( max. display is 19.99 ma ). Slide the " Range Switch " ( 3-4, Fig. 1 ) to " 0-24.0 ma " position for getting the 0.1 ma display resolution. 4) Adjust the " Calibration Adjust knob " ( 3-5, Fig. 1 ) will generate the current output same as the display value. Note : The " Red Alligator clip " ( 3-9, Fig. 1 ) is for the positive current output. The " Black Alligator clip " ( 3-9, Fig. 1 ) is the " ground " for current output. 4-2 Current measurement 1) Install the " Cable Plug " ( 3-8, Fig. 1 ) into the " Input Socket " ( 3-7, Fig. 1 ). 2) Slide the " Function Switch " ( 3-2, Fig. 1 ) to the " ma MEASURE " position. 3) Slide the the " Range Switch " ( 3-4, Fig. 1 ) to " 0-19.99 ma " position for geeting the 0.01 ma display resolution ( max. display is 19.99 ma ). Slide the " Range Switch " ( 3-4, Fig. 1 ) to " 0-24.0 ma " position for getting the 0.1 ma display resolution. 4) Open the circuit in which current is to be measured and connect the " Alligator Clips " ( 3-9, Fig. 1 ) securely in series with the load in which the current is be measured. 5

Note : The " Red Alligator clip " ( 3-9, Fig. 1 ) is for the positive current measurement input. The " Black Alligator clip " ( 3-9, Fig. 1 ) is for the negative current measurement input. 4-3 Self-powered two-wire current loop measurement meter equivalant block diagram red clip DC 12 V + 19.99 + 2 V POWER SOURCE Current meter black clip - external Fig. 2 measuring load 1) Install the " Cable Plug " ( 3-8, Fig. 1 ) into the " Input Socket " ( 3-7, Fig. 1 ). 2) Slide the " Function Switch " ( 3-2, Fig. 1 ) to the " POWER/ ma MEASURE " position. 3) Slide the " Range Switch " ( 3-4, Fig. 1 ) to " 0-19.99 ma " position for getting the 0.01 ma display resolution ( max. display is 19.99 ma ). Slide the " Range Switch " ( 3-4, Fig. 1 ) to " 0-24.0 ma " position for getting the 0.1 ma display resolution. 4) Open the circuit in which current is to be measured and connect the " Alligator Clips " ( 3-9, Fig. 1 ) securely in series with the load in which the current is be measured. 6

Note : a. The " Red Alligator clip " ( 3-9, Fig. 1 ) is for the positive current measurement input. The " Black Alligator clip " is for the negative current measurement input. b. The measuring procedures & principal are the same as those in 4-2 Current measurement except the fact that the 12V DC power source is derived from the calibrator rather than from an external voltage source 4-4 DC mv source 1) Install the " Cable Plug " ( 3-8, Fig. 1 ) into the " Input Socket " ( 3-7, Fig. 1 ). 2) Slide the " Function Switch " ( 3-2, Fig. 1 ) to the " VOLTAGE SOURCE " position. 3) Adjust the " Calibration Adjust knob " ( 3-5, Fig. 1 ) will generate the voltage ( mv ) output same as the display value. Note : The " Red Alligator clip " ( 3-9, Fig. 1 ) is for the positive voltage output. The " Black Alligator clip " ( 3-9, Fig. 1 ) is for the negative voltage output. 7

5. REPLACEMENT OF BATTERY 1) When LCD display show the " BAT " marker, It is necessary to replace the battery. However, in-spec measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate. 2) Slide the " Battery Cover " ( 3-6, Fig. 1 ) away from the instrument by loss the screw and remove the battery. 3) Replace with 9V battery ( Alkaline or heavy duty type ) and reinstate the cover. 4) Make sure the battery cover is secured after change the battery. RS Components UK Tel: 01536 201234 PO Box 99 Corby Northamptonshire NN17 9RS United Kingdom Fax: 01536 405678 8 0009-CC-421-RS