MEDMASTER EXTERNAL POWER SUPPLY



Similar documents
SAFETY RECOMMENDATION

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Advantium 2 Plus Alarm

BACnet Automation Interface Module (Network Version)

VK-250 WARRANTY REGISTRATION FORM

PGL5/6 - Parking Garage Luminaire Installation Instructions

Duct Humidity Transmitter

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

CHAPTER 1. GETTING STARTED... 1

Signal Manager Installation and Operation Manual

BroadBand PowerShield. User Manual

Model SRMD Setra Remote Monitoring Display

User Guide. HDMI Active Cable Extender. DVI-7370c

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

AXIS T81B22 DC 30W Midspan

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

12V Dimmable Driver EL-TMDRVR

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

VLT Series 300 Watt True Sine Wave Inverter

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

TC-9102 Series Surface Mount Temperature Controllers

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION

SSNICLRG SSNICSM PLNICLRG PLNICSM

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

Utility Distribution Systems

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Ceiling Mount Air Handler Manual

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Automatic Phone-Out Home Monitoring Systems

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

PagePac PAGEPAL V

12-Volt 10-Amp Regulated Power Supply

INSTALLATION INSTRUCTIONS

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Triple Expansion Chassis

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Die-Cast Metal, Motion- Activated Post Light

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

, User s Manual

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

Color Splash LED Light Fixture Installation and Operation Guide

G670 Intermittent Pilot Ignition Controls

On/Off Relay Switch and 3-Way Switch Kit

Manual. Solar Fountain Mobile Phone Charger

OPTOTRONIC LED Power Supply OT180W/UNV/800C/2DIMLT2/P6 - Technical Specifications

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

INSTRUCTION MANUAL MODEL PCD-88

GAS SAFETY PRECAUTIONS

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

tire inflator with pressure gauge

PART 1 - INTRODUCTION...

Part I - Installation

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER DS BMW 335i 3.0L

Instructions for Connecting PETROSMART EZ Control Systems To Wayne Electronic Dispensers With/Without CAT CREDIT CARD MODULES

LED MOTION ACTIVATED FLOOD LIGHT

Instructions & Safety Information Models A220-20D and A220-20L Version 2

ROUTER TABLE INSERT ASSEMBLY AND OPERATING INSTRUCTIONS

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

PWM-60 series IP67 TRC ELECTRONICS, INC

Water Leak Detection System

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

Switching Power Module

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Threaded Inline Air Heaters

Battery Power Inverters

Single Station Remote Alarm

INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

Single Phase Soft Starter

Radiant Temperature Sensor TY7321

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

ST Series POWER SUPPLIES USER INSTRUCTIONS

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Antec TruePower User's Manual

LED-INTA-0024V-41-F-O

Installation and Operation Guide for PD4100 Series Power Control Centers

About Your NetBotz 4-20mA Sensor Pod

How To Test A Power Distribution Unit

Installation Instructions WARNING: WARNING: WARNING: WARNING: WARNING:

Configuration Instructions

InHome Water Leak Detection Package

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Installation & Maintenance Instructions

KVM - DVI, USB 2.0, Cat 5 Extender

Transcription:

PROJECT INFORMATION Job Name MEDMASTER EXTERNAL POWER SUPPLY MRIPS-312 SERIES PRODUCT FEATURES: Recommended for MRI CleanScene, Downlight, Auracyl Sconce, Stratalume Undercabinet and Envela Remote mounted outside EMI shielded structure 13.5" 8.5" Provides DC Power to MedMaster MRI luminaires ETL Listed power supply and enclosure Fixture Type Catalog Number Approved by SPECIFICATIONS HOUSING: Die formed marine grade extruded aluminum. Black TGIC polyester powder coat finish 5-stage pre-treatment; Salt spray test: 1,000 hours. ELECTRICAL: INPUT: 120~240 VAC, 50/60 Hz. Active PFC Function, PF>0.95. OUTPUT: Constant-voltage DC output. Factory preset at 24VDC, adjustablerange 20~26.4VDC. Maximum current load 13ADC. WARRANTY: This product is warranted by Kenall Manufacturing to be free of defects in workmanship and materials for a period of one year from the date of invoice. The DC power supply contained in the enclosure carries a five-year warranty from the date of invoice. Warranty is void if all wiring is not completely shielded in grounded conduit. LISTINGS: Power supply is certified to UL1012 and CSA C22.2 No. 107.1 by Intertek Testing Services. Dry Location only. NOTE: See Kenall luminaire specifications that utilize remote power supplies for use with this unit. INSTALLATION WIRING/CONDUIT: All power and signal wiring must be completely shielded in grounded conduit. Total length of low-voltage supply wires, at least 18AWG, from power supply to filter to luminaires, should not exceed 50 feet (15m). EMI FILTERS: All MRI room EMI filters must be sized as suitable for power supply load (supplied by others). AMBIENT TEMPERATURE/HUMIDITY: The surrounding ambient temperature must remain below 104 F (40 C). The working temperature is between -20~+65 C. Allowable relative humidity is 20~90% non-condensing. PRODUCT LOCATION: The MRIPS-312 power supply must be installed outside the shielded MRI environment. It contains ferrous components that can damage or interfere with MRI equipment. A minimum free-air spacing must exist of 3" around all sides and 6" over exhaust fan. Location should not allow excessive dirt/dust to clog ventilation holes and prevent internal air circulation. 8.41 13.50 2.94 MRIPS-312-021414

MEDMASTER External Power Supply for MRI Luminaires MRIPS SERIES INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: 1 THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. DISCONNECT POWER TO ALL CIRCUITS BEFORE WIRING FIXTURE. INSTALL IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL CODES. DO NOT CONNECT TO AN UNGROUNDED SUPPLY. READ ALL FIXTURE MARKINGS AND LABELS TO ENSURE CORRECT INSTALLATION OF FIXTURE. SUPPLEMENTAL INSTRUCTIONS MAY BE LOCATED ON THE FIXTURE, IN ADDITION TO THIS INSTRUCTION SHEET, REGARDING ORIENTATION, OR MOUNTING RESTRICTIONS. INSTALLATION INSTRUCTIONS SAVE THESE INSTRUCTIONS This instruction sheet applies for the Kenall MRIPS-312 External Power Supply. It describes the proper mounting procedure and wiring instructions for singular and multiple fi xture confi gurations. A separate instruction sheet is provided with the MRI luminaire(s). Both sheets together are intended to provide comprehensive instructions on system installation and electrical wiring. The Kenall MRIPS-312 power supply and EMI fi lter (by others) must be installed outside the shielded MRI environment. It contains ferrous components that can damage or interfere with MRI equipment.

2 Power Supply Mounting Procedure Follow instructions provided with the luminaires for the proper installation procedure. Make electrical connections to power supply after luminaires are mounted. 1. Locate suitable mounting location for the power supply. Location should be chosen based on the following requirements: A. Ambient Temperature/Humidity: The surrounding ambient temperature must stay below 104 F (40 C). Allowable relative humidity is 20~90% non-condensing. Product is rated for DRY locations only. B. Wire Distance: The length of 24V DC supply wires from power supply to luminaires should not exceed 50 feet (15m). In multiple-luminaire confi gurations, this is the distance to the last luminaire in the run. C. Ventilation Hole Spacing: Maintain at least 3 of free-air spacing must exist around all sides and at least 6 over exhaust fan. D. Contaminants: Location should not allow excessive dirt/dust to clog ventilation holes and prevent internal air circulation. 2. Securely mount enclosure to a mechanically-sound surface. Use hardware appropriate for the installation (not provided). Single Power Supply Wiring Procedure Use the following procedure if only one power supply is to be connected in this installation. Refer to page 3 for multiple power supply installations. 3. Open wire access cover to expose wiring compartments (see Figure 1). 4. Secure conduit to low voltage and line voltage compartments using either the front or side KO locations. Class 1 wiring is required. 5. Make 120-240VAC, 50/60Hz supply connections on line voltage side. Make sure proper ground is connected. NOTE: 24VDC and Dimming Wires to be run through same conduit.

3 6. Run conduit and DC wiring to an MRI room EMI fi lter sized to the load of the power supply (supplied by others). See Figure 2. Make sure wiring is completely enclosed in grounded conduit. Any gaps, regardless of size, must be closed or wrapped in copper foil tape. 7. If a 0-10V dimmer is to be connected, install at this time. See Figure 2. Dimmer must be installed outside the shielded MRI environment with an intermediate MRI room EMI fi lter to the luminaires. Kenall recommends using a Leviton lllumatech IP710 series dimmer or Grafi k Eye GRX-TVI control interface. Contact Kenall for suitability of using an alternate sink-type 0-10V dimmer. WARNING: all DC power and dimming signal wiring must be run through separate EMI fi lters. 8. Run low voltage supply wires to luminaires using at least 18 AWG wires. Wire distances should not exceed 50 feet (15m) to prevent signifi cant line losses. Class 1 wiring is required. Make sure wiring is completely enclosed in grounded conduit. Any gaps, regardless of size, must be closed or wrapped in copper foil tape. Special attention should be paid to the wiring entry point into the shielded space. 9. Make connections to luminaires following the procedure in the luminaire installation instructions. NOTE: see Maximum Fixture Connection section for the maximum number of luminaires that can be connected to each power supply. 10. Complete any remaining steps on luminaire installation. 11. Connect power on line voltage side and test system operation. Test operation of lighting during MRI machine idle mode and during scanning operations. 12. Fill out the Installation Registration Form (attached) and fax to Kenall at (847) 360-1781. Multiple Power Supply Wiring Procedure Installations involving many luminaires may require multiple power supplies to handle the load. This section describes the procedure for properly wiring this situation. See Maximum Fixture Connection section for the maximum number of fi xtures that can be connected to each power supply. 13. Mount power supplies in the same manner as described in Section II. 14. Wire line voltage and low voltage connections similar to Section II, except follow the wiring diagram shown in Figure 3 to connect to each fi xture group. All DC Ground (black) leads must be tied together. WARNING: do not exceed the rated wattage of each power supply (312W). MRI room EMI fi lters are still required and must be sized to the load of the supply.

4 Maximum Fixture Connection Use the table below to determine the maximum number of luminaires that can be connected to an individual power supply. The maximum recommended DC amperage leaving the power supply should not exceed 13.0A. CUSTOMER SERVICE For technical assistance, call 1-800-4KENALL (1-800-453-6255). WARRANTY When installed to these instructions, this product is warranted by Kenall to be free of defects in workmanship and materials for a period of one year from the date of invoice. The DC power supply contained in the external power supply carries a three year warranty from the date of invoice. The warranty is void if all power and dimming signal wiring is not completely shielded in grounded aluminum conduit and installed with a suitable MRI room fi lter (by others). Kenall reserves the right to issue credit, repair, or replace the defective merchandise, at its discretion, upon notifi cation and confi rmation by its local representative of the defect. Kenall also reserves the right to test and examine the defective product if the defect is questionable and to deny the warranty herein for any product altered, improperly installed, installed in applications for which it is not intended. This includes operation in ambient temperatures above stated limits for any length of time. Failure by electrical surge shall not be covered under warranty. Kenall assumes no responsibility for labor or freight costs incurred in connection with the installation, removal, or replacement of products determined to be defective or any other consequential or incidental damages arising from the use of the product. Kenall s entire liability on any claim of loss or damage resulting from a defective product is limited to the replacement price of the product. The foregoing warranty is exclusive of all other warranties and no other warranties of any kind are expressed or implied.

4 Maximum Fixture Connection Use the table below to determine the maximum number of luminaires that can be connected to an individual power supply. The maximum recommended DC amperage leaving the power supply should not exceed 13.0A. CUSTOMER SERVICE For technical assistance, call 1-800-4KENALL (1-800-453-6255). WARRANTY When installed to these instructions, this product is warranted by Kenall to be free of defects in workmanship and materials for a period of one year from the date of invoice. The DC power supply contained in the external power supply carries a three year warranty from the date of invoice. The warranty is void if all power and dimming signal wiring is not completely shielded in grounded aluminum conduit and installed with a suitable MRI room fi lter (by others). Kenall reserves the right to issue credit, repair, or replace the defective merchandise, at its discretion, upon notifi cation and confi rmation by its local representative of the defect. Kenall also reserves the right to test and examine the defective product if the defect is questionable and to deny the warranty herein for any product altered, improperly installed, installed in applications for which it is not intended. This includes operation in ambient temperatures above stated limits for any length of time. Failure by electrical surge shall not be covered under warranty. Kenall assumes no responsibility for labor or freight costs incurred in connection with the installation, removal, or replacement of products determined to be defective or any other consequential or incidental damages arising from the use of the product. Kenall s entire liability on any claim of loss or damage resulting from a defective product is limited to the replacement price of the product. The foregoing warranty is exclusive of all other warranties and no other warranties of any kind are expressed or implied.

4 Maximum Fixture Connection Use the table below to determine the maximum number of luminaires that can be connected to an individual power supply. The maximum recommended DC amperage leaving the power supply should not exceed 13.0A. CUSTOMER SERVICE For technical assistance, call 1-800-4KENALL (1-800-453-6255). WARRANTY When installed to these instructions, this product is warranted by Kenall to be free of defects in workmanship and materials for a period of one year from the date of invoice. The DC power supply contained in the external power supply carries a three year warranty from the date of invoice. The warranty is void if all power and dimming signal wiring is not completely shielded in grounded aluminum conduit and installed with a suitable MRI room fi lter (by others). Kenall reserves the right to issue credit, repair, or replace the defective merchandise, at its discretion, upon notifi cation and confi rmation by its local representative of the defect. Kenall also reserves the right to test and examine the defective product if the defect is questionable and to deny the warranty herein for any product altered, improperly installed, installed in applications for which it is not intended. This includes operation in ambient temperatures above stated limits for any length of time. Failure by electrical surge shall not be covered under warranty. Kenall assumes no responsibility for labor or freight costs incurred in connection with the installation, removal, or replacement of products determined to be defective or any other consequential or incidental damages arising from the use of the product. Kenall s entire liability on any claim of loss or damage resulting from a defective product is limited to the replacement price of the product. The foregoing warranty is exclusive of all other warranties and no other warranties of any kind are expressed or implied.