HeatSource HS1800 Heater



Similar documents
User's Instructions. Alpha HE CB25/33 and HE SY25

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

San josé OWNER S MANUAL

Shower Handbook (Also covers 650 chrome variant)

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Baxi Combi 80e & 105e

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

orlando OWNER S MANUAL

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

INFRARED QUARTZ WALL HEATER

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60

Mikrofill Ethos Condensing combination boiler

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Water Heater MkII WH1302 / WH1302B INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

HEAVY DUTY STORAGE GAS

Cooktop Low-Profile Ventilation Hoods


SF15K SF05KSS, SF10KSS

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

AquaNova. Water heater. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

E-gas Instant Gas Water Heaters

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

For installation guide see reverse of book

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

ELECTRONICS G H I J K L M

Operating instructions

3 IN 1 BATHROOM HEATER

Alpha CD13R,18R and 24R

Response: The combi boiler. Response: The fit anywhere combi

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Getting the best from your urn

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Operating instructions

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

1 DESCRIPTION OF THE APPLIANCE

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

SERVICE MANUAL REFRIGERATION

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Portable Air Conditioner

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

DIMENSION ELECTRIC RANGE


tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

SELECTION, APPLICATION AND MAINTENANCE

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

Munchkin Heat Exchanger Maintenance

Installation and Servicing Instructions. Eco. Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler

Manual for Fire Suppression & Methane Detection System

Drayton Digistat +2RF/+3RF

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Combi 24 HE. User s Guide and Important Warranty Information

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

V94 BULK TAPE DEGAUSSER

Spare Parts List M96A.24SM/B M96A.28SM/B

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Invisidor STYLE Air Curtain

GUIDELINES - Gas Inspection Regulations 1. Recommendations for camping site owners

Electric Instantaneous. Water Heaters. Service manual

Air Conditioning Sign-Off Sheet

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI


Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

CHAPTER 11 HEATING, VENTILATION AND AIR CONDITIONING. Section Title Page

SERVICE TIPS. Dometic REFRIGERATORS. Models. OS1927 4/96 Copyright 1996 The Dometic Corporation

VOYAGER 570G. 744A Sprayer Control

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

HVAC SYSTEM (AUTO A/C) (DIAGNOSTICS) AC

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER

CARING FOR YOUR WATER HEATER

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

ASX7-4-IOM-7 J

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

COMMERCIAL GAS DRYER

Hi-Spec. sustainable solutions under one roof HEATING HOT WATER VENTILATION. Warm Air Heaters. with System E-T & Basic Control USERS INSTRUCTIONS

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Operating instructions

Transcription:

HeatSource HS1800 Heater Vehical Installation & Operating Instructions Propex Heatsource Ltd Unit 5, Second Avenue Buisness Park, Milbrook, Southampton, SO15 OLP Tel: 023 8052 8555 Fax: 023 8052 8800 Website: www.propexheatsource.co.uk Email: info@propexheatsource.co.uk

SAFETY WARNINGS & GENERAL INFORMATION The heater must be installed by a corgi registered person or inspected by a corgi registered person in accordance with the relevant regulatory and safety requirements. Heater installations must comply with the current British standards for motorhomes / Caravans and BS5482 Part 3 for Boats. The Heatsource HS1800 heater is not suitable for installation on the outside of the vehicle. The heater must not be operated when refueling or when the vehicle is in a confined space, such as a garage. The exhaust gas outlet must not be fitted on the entry door nor in any position where combustion products may enter the interior. The Heatsource HS1800 heater is designed to operate on Propane gas 'mbar or Butane at 28 or 30mbar. The HS1800 may also be used on mbar propane but the heat output will be reduced. A 50mbar Propane model is also available. Under no circumstances should an adjustable regulator be used. Do not allow materials to come in to direct contact with the heater. Under circumstances must the intake grill be covered or obstructed at any time. The Heatsource HS1800 heater has been tested and passed the relevant sections of the following standards: EN5008-1 EN55014-1 EN60945 EN50082-1 EN50014-2 EN50165 IS07637-1 ISO7637-2 PREN624 EN298 The data label is situated adjacent to the gas inlet. The gas supply line should be checked regularly for damage or leaks and tested under pressure with a proprietary leak tester. NEVER TEST FOR GAS LEAKS WITH NAKED FLAME. If a gas leak is detected or smelt, turn off gas at the bottle immediately and ventilate the area. Contact a corgi registered installer to rectify the problem. The heater is suitable for use while the vehicle is in motion subject to gas regulations. Heatsource is suitable for boats when supplied with the correct marine installation kit

VEHICLE INSTALLATION a) Find a suitable location, usually in a bedbox, locker or base of a cupboard. The Heatsource HS1800 should be fitted in an area allowing a minimum distance of 25mm from adjacent walls, ceiling or shelves from the main body of the heater. Check that there are no chassis members underneath the location of the exhaust and combustion air spigots. b) Using the template provided, drill a 3mm pilot hole through the exhaust and combustion air spigot centres. Examine underneath the vehicle to check that there is adequate clearance for a 30mm hole saw. Cut away any carpet or matting around the exhaust and open out the holes to 30mm. c) Loosen the 4 x M4 screws on the base of the heater and slot the mounting brackets into position, then re-tighten the screws. Mount the heater in position and mark the 4 mounting holes on the floor of the vehicle for screwing the heater down. Remove the heater and drill 4 x 3.5mm holes in the marked positions, then screw the heater in place with the 3/4 x NO.8 self tapping screws provided. d) Find suitable locations for the hot air outlet and re-circulation air inlet vent and drill a 5mm pilot hole through each centre. Using a 95mm hole saw, drill out the holes and fix the vents in position using the black 1/2 x No.8 counter sunk self tapping screws provided. e) Fix the 60mm reducer (push fit) into the back of the hot air outlet. Cut the 60mm thermoplastic ducting to length and fix to the heater and the outlet using the 50-70mm hose clips provided. NOTE: There is no reducing spigot provided for the air inlet vent, as it is not necessary to put ducting on it.

A metre length of 22mm flexible stainless steel tubing with a special end is supplied for ducting the products of combustion away to the edge of the vehicle. The tube may be cut to length and fixed to the heater using the clip provided. A clip is provided for fixing the end of the pipe to the underside of the with the end cap slightly protruding under the sill or bumper and pointing towards the rear of the vehicle. If it not possible to exhaust the heater to the sill then it is permissible to terminate the flue underneath the vehicle but it if it exists in an under-floor box section then at least one side must be open to the atmosphere. The maximum overall length of the flue and inlet pipe combined can be up metres if required. However, the flue pipe should never be shorter than the combustion air inlet pipe. 0mm length of combustion air pipe is provided, which is also fitted with an end cap. This should be attached to the heater with the hose clip and pointed in the same direction as the flue pipe. The combustion air pipe can be terminated underneath the vehicle making sure the end of it is at least 0.5 metres away from the end of the exhaust. Take care to ensure that both pipes have a slight downward slope to prevent any possibility of water traps. Make sure that the flue is not terminated in an under-floor box section. GAS CONNECTION The heater uses an 8mm (5/16") gas connection which also incorporates a point. The gas supply should be connected with copper gas pipe with an isolating valve and all connections made with brass compression fittings, fitted with proper olives. When the gas line is complete all joints should be tested for leaks using leak detection solution - NEVER WITH A NAKED FLAME. Gas pressure should be verified at the test point using a low pressure gauge or "U" tube, any tests or connections should only be undertaken by a corgi registered person.

WIRING INSTRUCTIONS a) The Heatsource HST800 heater is supplied with 2 wring looms, a 2 core (red ad black) ad a 5 core (red, black, orange, white ad green), both are fitted with terminals ad housings to plug into the main PCB inside the heater and are supplied already connected. b) Find a suitable location for the thermostat between waist ad shoulder height. Make sure that it is not mounted in an area with poor air circulation or in an area with above average heat, such as above a cooker, refrigerator or in direct sunlight. c) When you have chosen the location, drill a pilot hole in the area you expect to retrieve the 5 core cable. If the clearance is OK, open the pilot hole out to 10mm. d) Run the 5 core cable from the heater to the thermostat location and remove approximately 60mm of the outer insulation. e) Remove the thermostat knob by gently prizing it off and undo screws "A" to remove the cover. f) Fix the backplate with the PCB to the wall making sure the 5 core cable is pulled through the hole in the centre. g) Connect the cable to the terminal blocks as in the diagram and refit the lid. h) Replace the thermostat knob ad push the finishing caps into the lid to cover the screw heads i) Run the 2 core cable to a convenient supply (usually at the battery) ad connect using the fuse holder supplied. j) Insert the 5 amp fuse and test.

OPERATION Usage: Pay particular attention to the exhaust and combustion air inlets that neither have been blocked or damaged. Ensure that any snow or clear from the part of the vehicle where the heater exhaust is mounted. Check the gas supply is turned on and that the battery voltage is correct (see specifications). Rotate the thermostat dial fully anti-clockwise and push the 3 position switch to the left. The red power light should illuminate. Rotate the thermostat dial until the green light illuminates. After 3 seconds the heater motor will start and ignition should occur after a 30 second pre-cycle. Select the desired temperature setting by adjusting the dial on the thermostat. The heater will then cycle on and off to maintain that temperature. When the set temperature is reached the green light will go out and the heater will start its post purge cycle. When the motor switches off, the red heater light will dim indicating that the heater is on standby. The 3 position switch is depressed on the right, the green LED will illuminate and the fan will blow cold air continuously. sequence of operation: Switch on Heater motor starts 30 second pre-purge to clear gases from heat exchanger Gas valve opens Spark generator operates Heater lights and runs Temperature reaches thermostat setting Heater switches off First Purge - approx. 2mins depending on heat exchanger temperature Temperature drops Cycle repeated MAINTENANCE Installation should be inspected annually by a corgi registered person and servicing and cleaning identified carried out. The heater should not be left for long periods without use. It is advisable to run it for short periods throughout the summer. The outlet grill on the heater should be inspected periodically for excess foreign objects and cleaned if necessary.

FAULT FINDING The Heatsource HS1800 is equipped with an electronic diagnostic system for fault finding. In the Event of a failure the red light on the thermostat will flash a certain amount of times, then pause and it will repeat this until switched off. Manual (Overheat Cut-Out. The H S 1900 is equipped with a manual) resetting thermal cut-out in addition to the electronic cut-out This is designed to disengage the gas solenoid valve if the electronic cut-out toils and can operate if the heater is switched off at the battery isolating switch without allowing it to purge. It can be found by removing the inlet grill and following the two purple wires from the main PCB. Press the red button, the fault code would be 2 flashes FAULT FINDING TABLE No. Of Flashes Symptons Possible Causes 1 Failed to ignite No Gas left in bottle Bottle or gas tap turned off Incorrect gas pressure Igniter in heater failed 2 Flame Sensing Run out of gas whilst operating Gas switched off Ingestion of gas through combution air intake Low gas pressure 3 Low Voltage Battery voltage low Bad connection in supply Cut out 12v Model=10v 24v Model=18v 5 Combustion air flow low Blocked/Partially blocked exhaust/combustion air inlet Water trapped in exhaust pipe Damaged/crushed exhaust Fan motor running slow 6 Gas solenoid valve Faulty valve in heater 8 High voltage Voltage too high 12Vmodel = 15.5V - 24V model = 30V 9 Heat exchange temperature high Blocked inlet grill or obstructed hot air outlet Fan speed low Faulty thermistor