Ion-selective Measurements



Similar documents
Ion Selective Electrodes

Conductivity measurements are used for applications such as in the production of ultrapure water or determining the salinity of sea water.

BOD measurement. BOD measurements. Respiration. Biological Oxygen Demand. Depletion/Respiration

Measurement by Ion Selective Electrodes

Standard methods in water analysis

DPST-ELMETRON-meters. Contents: ELMETRON 100 series pocket instruments. ELMETRON 411 series portable meters. ELMETRON 401 series portable meters

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Electrochemistry - ANSWERS

Compact ph Measuring Instruments

Naming and Writing Formulas for Ionic Compounds Using IUPAC Rules

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Eutech 2700 Series. Bench Meters. ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature

Texas Commission on Environmental Quality

Additional Lecture: TITRATION BASICS

Balancing Chemical Equations Worksheet

Operating manual. ph 7310 ph 7310P. Printermodul. ph 7310P. ph ph meter

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

Decomposition. Composition

Nomenclature and Formulas of Ionic Compounds. Section I: Writing the Name from the Formula

1332 CHAPTER 18 Sample Questions

ICON Analyzer. Dedicated online photometer for water and wastewater analysis

OPERATIONS MANUAL. ba76143e04 09/ MultiLab DIGITAL METER FOR IDS SENSORS

OPERATING MANUAL. ba77053d01 02/ C :37 USB output. Multi 3320 METER FOR 2 SENSORS (PH/ORP/D.O./COND)

Moles, Molecules, and Grams Worksheet Answer Key

Solubility Product Constant

General Chemistry II Chapter 20

WRITING CHEMICAL FORMULA

CHAPTER 5: MOLECULES AND COMPOUNDS

Chapter 5. Chapter 5. Naming Ionic Compounds. Objectives. Chapter 5. Chapter 5

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

Nomenclature of Ionic Compounds

Conductivity and TDS Meters

Question Bank Electrolysis

Operating manual. ba75441e. inolab ph/cond 720. Measuring Instrument for ph, Redox, and Conductivity

Success criteria You should be able to write the correct formula for any ionic compound

Naming Compounds Handout Key

Compact Water Quality Meter B-700 series

Equipment for Analysis

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Periodic Table, Valency and Formula

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Monatomic Ions. A. Monatomic Ions In order to determine the charge of monatomic ions, you can use the periodic table as a guide:

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

SenTix 950 SenTix 980

K + Cl - Metal M. Zinc 1.0 M M(NO

Name: Class: Date: 2 4 (aq)

Complexometric Titrations

Titrette. class A precision. The next generation Digital Burette!

CHEMICAL NAMES AND FORMULAS

Name Electrochemical Cells Practice Exam Date:

Titrette. class A precision. The next generation Digital Burette!

ELECTROCHEMICAL CELLS

Chapter 6 Assessment. Name: Class: Date: ID: A. Multiple Choice Identify the choice that best completes the statement or answers the question.

Chapter 16: Tests for ions and gases

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

Operating manual. Multi 340i. mg/l. ARng. ph/dissolved Oxygen/Conductivity Measuring Instrument. ba52318e02 03/2004

Current Monitoring Kit

Test equipment for temperature and its reduction

Polyatomic ions can form ionic compounds just as monatomic ions.

Application Bulletin

Operating manual. ph/cond 3400i. Tref25 nlf C TP CAL. ph/conductivity measuring instrument. ba75687e01 01/2007

ION EXCHANGE FOR DUMMIES. An introduction

NAMING QUIZ 3 - Part A Name: 1. Zinc (II) Nitrate. 5. Silver (I) carbonate. 6. Aluminum acetate. 8. Iron (III) hydroxide

Ionic and Metallic Bonding

6 Reactions in Aqueous Solutions

Temperature & Humidity SMS Alert Controller

UltraBasic Benchtop ph Meter Operation Manual

PortaSens ll G AS DETECTOR

Unit 2 Periodic Behavior and Ionic Bonding

(b) Formation of calcium chloride:

Chemistry Themed. Types of Reactions

PAT Tester Printers and Barcode Scanners

Experiment 8 - Double Displacement Reactions

Wahl C50 Calibrator FEATURES

Chloride and Salinity

SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, "Chemistry 11", McGraw-Hill Ryerson, 2001

TurbiDirect TurbiCheck TurbiCheck WL

Galvanic Cells. SCH4U7 Ms. Lorenowicz. Tuesday, December 6, 2011

ATOMS. Multiple Choice Questions

A Potentiometric Analysis of Fluoride Ion in Toothpaste

W1 WORKSHOP ON STOICHIOMETRY

80. Testing salts for anions and cations

Current Monitoring Kit QUICK START GUIDE

Chemistry 51 Chapter 8 TYPES OF SOLUTIONS. A solution is a homogeneous mixture of two substances: a solute and a solvent.

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

HOMEWORK 4A. Definitions. Oxidation-Reduction Reactions. Questions

1. Inspection and monitoring... 3

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Nomenclature and the Periodic Table To name compounds and to determine molecular formulae from names a knowledge of the periodic table is helpful.

Chapter 7: Chemical Reactions

Experiment 5. Chemical Reactions A + X AX AX A + X A + BX AX + B AZ + BX AX + BZ

5000V Graphical Megohmmeter Model 5070

ph 200 ph-/redox-/temperature Meter Operating instructions

The Theory of ph Measurement

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

neutrons are present?

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

Method 8155 NITROGEN, AMMONIA (0 to 0.50 mg/l NH 3 -N) For water, wastewater, seawater

100% ionic compounds do not exist but predominantly ionic compounds are formed when metals combine with non-metals.

TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES

Transcription:

Ion-selective Measurements Ion-selective measurement is a method for determining the concentration of dissolved ions. Potassium ions, sodium ions, fluoride or chloride are examples of such cations and anions that are directly measured in solutions. Indirect methods such as titration allow the determination of aluminum, nickel ions, or sulfate. Measurement with ISEs, like the measurement of, is a potentiometric method. ISEs are in two configurations: 1. Separate ion-selective electrode and reference electrode An introduction to ion-selective measurement technology, as well as application reports, are available on our CD-ROM entitled Principles of measurement technology. 2. Combined ion-selective electrode with built-in reference electrode The ion-selective membrane of the electrode consists of a sparingly soluble salt of the ion to be measured (solid state electrodes), a PVC-membrane, modified by an ion ex changer or ion carrier (matrix electrodes), glass (glass electrode) or a gas-permeable plastic (gas-sensitive electrodes). The activity of the ions to be measured determines the electrode voltage. With increasing activity of the anions the voltage turns more negative; with increasing activity of cations, more positive. A /ISE meter uses the electrode signal to calculate the concentration of the sample. The wide range of possible applications include the measurement of fluoride concentration according to DIN 38405-4. Chloride content determination in concrete samples or nitrate concentration determination in fruit juices are further examples of the ways in which ion-selective measurement technology can be applied. Determination of Application Lead (Pb 2+ ) Soil samples Bromide (Br ) Wine, plants Cadmium (Cd 2+ ) Soil samples Calcium (Ca 2+ ) Dairy products Chloride (CI ) Drinking water, food Cyanide (CN ) Electroplating baths Fluoride (F )Toothpaste, cement Iodide (I ) Saltwater Potassium (K + ) Wine, fertilizer Copper (Cu 2+ ) Electroplating baths Sodium (Na + ) Wine, boiler feed water Nitrate (NO 3 ) Baby food, fertilizer, wastewater Silver (Ag + ) Electroplating baths Sulfide (S 2 ) Proteins, sediments 48

Laboratory Meters Application Range Ion-selective Measurements Recommended by WTW Application Range Suitable Laboratory ISE Benchtop Meters inolab /ION 7320** inolab /ION 7320 Portable meters /ION 340i/3400i*, Multi 350i/3500i* Occasional, simple ISE measurement m l Routine and standard measurement l m Advanced methods and procedures l see page 49 22, 51 Reliable documentation of ISE measurements with the inolab /ION 7320 The new inolab /ION 7320 is ideal for precision measurements and automatic documentation acc. to GLP/ AQA in quality laboratories for all branches. Optional available with built-in printer. 2-channel instrument for simultaneous measuring of, ISE or Redox Data transfer via USB interface For fast data transfer in.csv format or via the optional integrated printer CMC function for monitoring the measuring range for and ISE measurements * North American version ** available in Q4/2012 Software/ Printers Colony Counter Parameter ISE ORP Multiparameter Conductivity Dissolved Oxygen (D.O.) Data logger/ flow + level Turbidity Photometers BOD/ Respiration 49

Measuring stability Repeatable measuring results through active, automatic and stable measuring values The CMC function for and ISE visualizes the ideal measuring range and supports correct measuring. Graphic display with text menu for convenient handling Documentation acc. to GLP/AQA Alphanumeric entry of electrode serial number Transfer of all data in.csv format via USB interface to PC, a formatted transfer to Excel is also possible (MultiLab Importer software, included in the delivery scope or available as download). Data can be printed directly from the instrument via the optional integrated printer. Flexile and high-performing: 1 to 5 point calibration for 1 to 7 point calibration for ISE, also non-linear Blank value correction, increment methods: known addition, known subtraction, sample addition, sample subtraction, double known addition Value of concentration for different units Selectable AutoRead criterion DIN- or BNC model Backlit graphic display with CMC Technical Data Model /ION 7320 Range/ Resolution Accuracy (±1 digit) Calibration Ordering Information inolab Laboratory ISE Meter SETs Order No. Order No. inolab /ION 7320 inolab /ION 7320P mv Temperature Concentration mv Temperature AutoCal AutoCal-Tec ConCal ISECal -2.000... +20.000-999.9... +999.9 mv -2000... +2000 mv -5... +105 C/0,1 C (23.0 221 F) 0.000... 10.000 mg/l 0.00 100.00 mg/l 0.0 1000.0 mg/l 0 2000 mg/l ±0.004 ±0.01 ±0.2 mv, ±1 mv ±0.1 K MultiCal automatic calibration: 2-/3-/4-/5-point 2-/3-/4-/5-point 1-/2-point 2- bis 7-point Special functions: Known addition (single) Known subtraction Sample addition Sample subtraction Blank value addition Known addition with Blank value correction Precise and convenient /mv/ise benchtop meter for measurements/ documentation according GLP/AQA, with dual channel input. Single instrument with universal power supply, stand and operation manual, software and USB cable. Precise and convenient /mv/ise benchtop meter for measurements/ documentation according GLP/AQA, with dual channel input, with integrated thermal printer. Single instrument with universal power supply, stand and operation manual, software and USB cable. 1GA340 1GA340P 1GA330 1GA330P IP 43 cetlus 3 Year Warranty with BNC plug with DIN plug 50

Laboratory & Portable Meters Portable ISE Meter Parameter /ION 340i/3400i* Handy, waterproof Up to 1500 hours continuous operation GLP, mv and ISE measurements in one hand The /mv and ISE meter /ION 340i/3400i* offer the highest degree of flexibility possible. For measurements the instrument can be calibrated manually or auto matically and offers simultaneous display of and temperature. For measurements with ion-selective electrodes the /lon 340i/3400i* offers concentration display in mg/l. Direct display in mv to ±999.9 mv in 0.1 mv steps; and to ±1999 mv in 1 mv steps. Even in these higher ranges the concentration is calculated from a mv resolution of 0.1 mv. Calibration is carried out with up to three standards (selected from 16 standards in the range of 0.01 to 1000 mg/l). The instrument can be used in-the-lab or in-the-field, operating on either AC power or rechargeable battery for up to 1500 hours, with convenient LoBat warning. Lightweight and compact, these robust meters are both waterproof and submersible to IP 66/67. The built-in data logger for up to 500 measurements together with GLP calibration protocol offer a com pre hensive system for documenting results. With analog or digital data transfer (RS 232), automatic recognition of stable measurements (AutoRead), electrode evaluation and calibration interval monitoring functions ensure reproducible and comprehensible measurements. ISE ORP Multiparameter Conductivity Dissolved Oxygen (D.O.) Data logger/ flow + level Technical Data Model Range/ Resolution Accuracy (±1 digit) Calibration mv Temperature Concentration AutoCal AutoCal-Tec ConCal ISECal /ION 340i/3400i* -2.000... +19.999-999.9... +999.9 mv -1999... +1999 mv -5... +105 C/0.1 C (23.0 221 F) 0.01... 1999 mg/l ±0.003 ±0.01 ±0.2 mv, ±1 mv ±0.1 K Ordering Information Portable ISE Meter MultiCal automatic calibration: 2-point 2-point 1-/2-point 2-/3-point Order No. /ION 340i/3400i* Robust and waterproof portable ISE meter with data logger and serial interface 2G30-100 Universal power supply 100 V - 240 V, 50-60 Hz; for 340i series 902 867 IP 66 IP 67 cetlus 3 Year Warranty * North American version Turbidity Photometers BOD/ Respiration Colony Counter Software/ Printers 51

reference electrode Ion-selective Electrodes WTW offers a complete range of ion-selective electrodes for challenging ISE applications. Choose between two types: the 500 Series half cells, which require a separate reference electrode, or the 800 Series combination electrodes. 500 Series The 500 Series half cells require a separate reference electrode (exception: the Ammonia electrode NH 500/2 contains an integrated reference electrode). Half Cells Series 500 Electrode type Membrane Determinable ions Half cell, reference electrode necessary: Measuring range Ammonia (NH + 4 ) Ammonia NH 500/2 0.02...900 mg/l 10-6...5 x 10-2 mol/l Lead (Pb 2+ ) S Lead Pb 500 0.2... 20000 mg/l 10-6... 10-1 mol/l Bromide (Br - ) S Bromide Br 500 0.4... 79000 mg/l 5 x 10-6... 1 mol/l Cadmium (Cd 2+ ) S Cadmium Cd 500 0.01... 11000 mg/l 10-7... 10-1 mol/l Calcium (Ca 2+ ) L Calcium, Ca 500 0.02... 40000 mg/l Magnesium 5 x Chloride (CI - ) S Chloride CI 500 2... 35000 mg/l R 503/P 5 x 10-5... 1 mol/l Cyanide (CN - ) Fluoride (F - ) S S Cyanide Fluoride, Aluminum CN 500 F 500 (2 mm pin plug) 0,2... 260 mg/l 8 x 10-6... 10-2 mol/l 0.02...sat. mg/l Iodide (I - ) S Phosphate 3, Lithium3 Iodide, Thiosulfate I 500 or 10-6...sat. mol/l 0.006... 127000 mg/l Mercury R 503 D 10 x 10-8... 1 mol/l Potassium (K + ) 5 L Potassium K 500 (4 mm 0.04... 39000 mg/l banana 10-6... 1 mol/l plug) Copper (Cu 2+ ) S Copper, Nickel 3 Cu 500 0.0006... 6400 mg/l 10-8... 10-1 mol/l Bridge electrolyte Ionic strength adjustment solution Standard solution (Conc. 10 g/l) For ordering information for ISE electrodes and accessories, see WTW Product Details. range MZ/NH 3 /CN ES/NH 4 4-12 ELY/BR/503 ISA/FK ES/Pb 4-7 ELY/BR/503 ISA/FK ES/Br 1-12 ELY/BR/503 ISA/FK 2-8 ELY/BR/503 ISA/Ca ES/Ca 2,5-11 ELY/BR/503 ISA/FK ES/CI 2-12 ELY/BR/503 MZ/NH 3 /CN 0-14 ELY/BR/503 TISAB ES/F 5-7 ELY/BR/503 ISA/FK ES/I 0-14 ELY/BR/503/K ISA/K ES/K 2-12 ELY/BR/503 ISA/FK ES/Cu 2-6 Sodium (Na + ) 5 G Sodium DX 223 NA 0.05... 23000 mg/l ISA/Na ES/Na >10 2 x 10-6... 1 mol/l Nitrate (NO - 3 ) 5 L Nitrate NO 500 0.4... 62000 mg/l ELY/BR/503/N TISAB/NO 3 ES/NO 3 2,5-11 7 x 10-6... 1 mol/l Silver (Ag + )5 S Silver Ag/S 500 0.01... 108000 mg/l ELY/BR/503 ISA/FK 2-12 Sulfide (S 2- )5 S Sulfide Ag/S 500 0.003... 32000 mg/l ELY/BR/503 2-12 1 Exchange measuring head 2 S = solid state electrode, L = matrix electrode, G = glass electrode 3 Titration 4 Use according to operating instructions 5 Formulations for additionally required solutions are given in the application steps and operating instructions 52

Ion-selective Electrodes 800 Series Parameter These combination electrodes with built-in reference are easy-to-use, and offer the option of measuring in small volume samples. Plus, they have an out-standing price performance ratio. ISE ORP Multiparameter Combined ISE Electrodes Series 800 Electrode type Membran Determinable ions Built-in reference electrode Measuring range Lead (Pb 2+ ) S Lead Pb 800 0.2... 20000 mg/l 10-6... 10-1 mol/l Bromide (Br - ) S Bromide Br 800 0.4... 79000 mg/l 5 x 10-6... 1 mol/l Cadmium (Cd 2+ ) S Cadmium Cd 800 0.01... 11000 mg/l 10-7... 10-1 mol/l Calcium (Ca 2+ ) L Calcium, Ca 800 0.02... 40000 mg/l Magnesium 5 x Chloride (CI - ) S Chloride Cl 800 2... 35000 mg/l 5 x 10-5... 1 mol/l Cyanide (CN - ) S Cyanide CN 800 0.2... 260 mg/l 8 x 10-6... 10-2 mol/l Fluoride (F - ) S Fluoride, Aluminum F 800 0.02...sat. mg/l Phosphate 3, Lithium3 10-6...sat. mol/l Iodide (I - ) S Iodide, Thiosulfate Mercury I 800 0.006... 127000 mg/l 10 x 10-8... 1 mol/l Bridge electrolyte Ionic strength adjustment solution Standard solution (Conc. 10 g/l) For ordering information for ISE electrodes and accessories, see WTW Product Details. range ELY/BR/503 ISA/FK ES/Pb 4-7 ELY/BR/503 ISA/FK ES/Br 1-12 ELY/BR/503 ISA/FK 2-8 ELY/BR/503 ISA/Ca ES/Ca 2,5-11 ELY/BR/503 ISA/FK ES/CI 2-12 ELY/BR/503 MZ/NH 3 /CN 0-14 ELY/BR/503 TISAB ES/F 5-7 ELY/BR/503 ISA/FK ES/I 0-14 Potassium (K + ) L Potassium K 800 0.04... 39000 mg/l ELY/BR/503/K ISA/K ES/K 2-12 10-6... 1 mol/l Copper (Cu 2+ ) S Copper, Nickel Cu 800 0.0006... 6400 mg/l ELY/BR/503 ISA/FK ES/Cu 2-6 10-8... 10-1 mol/l Nitrate (NO - 3 ) L Nitrate NO 800 0.4... 62000 mg/l ELY/BR/503/N TISAB/NO 3 ES/NO 3 2,5-11 7 x 10-6... 1 mol/l Silver (Ag + ) S Silver Ag/S 800 0.01... 108000 mg/l ELY/BR/503 ISA/FK 2-12 Sulfide (S 2- ) S Sulfide Ag/S 800 0.003... 32000 mg/l ELY/BR/503 2-12 1 Exchange measuring head 2 S = solid state electrode, L = matrix electrode, G = glass electrode 3 Titration 4 Use according to operating instructions 5 Formulations for additionally required solutions are given in the application steps and operating instructions Conductivity Dissolved Oxygen (D.O.) Data logger/ flow + level Turbidity Photometers BOD/ Respiration Colony Counter Software/ Printers 53