Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

Similar documents
Adaptive strategies for office spaces in the UK climate

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

ResearcH JournaL 2009 / VOL

Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

AN APPLICATION MANUAL FOR BUILDING ENERGY AND ENVIRONMENTAL MODELLING

WALLS Three common wall types are described below, with their insulation solutions.

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

3-D Modeller Rendered Visualisations

CHAPTER 3. The sun and the seasons. Locating the position of the sun

Improving thermal insulation of concrete sandwich panel buildings

Constructions Database User Guide <Virtual Environment> 5.9

Diego Ibarra Christoph Reinhart Harvard Graduate School of Design

SELECTIVE GLAZING FOR SUN CONTROL

Energy Efficiency HOSPITALITY.

Humid Air. Water vapor in air. Trace Glasses 1% Argon (A) Water vapor (H 2

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

LOW-E PHOTOVOLTAIC GLASS TECHNICAL GUIDE

UNIT 6a TEST REVIEW. 1. A weather instrument is shown below.

Greenhouse Glazing Effects on Heat Transfer for Winter Heating and Summer Cooling

Energy efficient home design

Pilkington Activ. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

CO2 Emissions. Indirect CO 2. Emissions Electricity and Heat Production 25 % Direct Emissions AFOLU 24 % Energy 1,4% Buildings 6,4 % Industry 11 %

National Building Code of Canada 2010

RESNET National Rater Test Study Guide Outline

Energy Efficiency. Bars & RestauRants.

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Klosterenga, Oslo, Norway, page - 1

Efficient use of energy simulation in the early design phase

Building skin and energy efficiency in a hot climate with particular reference to Dubai, UAE

Case Study 13 Schools of Architecture and Design, Wellington tertiary education institute, New Zealand

Priority School Building Programme

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.

Selecting Energy Efficient New Windows in Texas

Selecting Energy Efficient New Windows in Florida

Molds and mildew are fungi that grow

2.1 The performance of bus air conditioning system is evaluated in the following operating conditions

How do I measure the amount of water vapor in the air?

Purpose: To determine the dew and point and relative humidity in the classroom, and find the current relative humidity outside.

Energy Efficient HVAC-system and Building Design

Energy savings in the residential area are essential in

Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE

CONDENSATION IN REFRIDGERATED BUILDINGS

Residential Windows, 3 rd edition Corrected index 1

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

EVALUATION OF THE PMV THERMAL COMFORT INDEX IN OUTDOOR WEATHER CONDITIONS JuYoun Kwon and Ken Parsons

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Selecting Energy Efficient Replacement Windows in Nevada

1..GENERAL DATA 2. CLIMATIC DATA. Location

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

Selecting Energy Efficient New Windows in Georgia

HDA

Holistic Approach in Delivering Government Buildings The Low Carbon Concept

Selecting Energy Efficient New Windows in Arizona

Unbeatable energy efficient glass curtain wall system

THE EFFECT OF WINDOW POSITION AND WINDOW SIZE ON THE ENERGY DEMAND FOR HEATING, COOLING AND ELECTRIC LIGHTING. R.M.J. Bokel

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

Miami Science Museum DoE Modelling Grant. Light Planning. 19 December 2008 Concept Design

SYSTEMS INTEGRATION SYSTEMS INTEGRATION. Air handler uses heat recovery on exhaust air to temper incoming ventilation air Oxbow skylight

Executive Order amending the Executive Order on the Publication of the Danish Building Regulations 2010 (BR10) 1)

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

Humidity, Condensation, Clouds, and Fog. Water in the Atmosphere

Temperature and Humidity

AIRCONDITIONING Cooling Loads Calculations

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

COOLING AND HEATING OF BUILDINGS BY ACTIVATING THEIR THERMAL MASS WITH EMBEDDED HYDRONIC PIPE SYSTEMS -

Heating and cooling. Insulation. Quick facts on insulation:

TRANSSOLAR Climate-Engineering

Cooling Load Calculations and Principles

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

Building Energy Systems. - HVAC: Heating, Distribution -

How To Design A Room Air Conditioning System

Adapting to Change: New Thinking on Comfort Natural ventilation in UK schools: design options for passive cooling Steven Firth* and Malcolm Cook

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

Condensing Boiler Efficiency

Solar Energy Utilisation in Buildings

Application of Building Energy Simulation to Air-conditioning Design

Harvesting Solar Energy

EXPLANATION OF WEATHER ELEMENTS AND VARIABLES FOR THE DAVIS VANTAGE PRO 2 MIDSTREAM WEATHER STATION

THE EUROPEAN GREEN BUILDING PROGRAMME. Building Envelope Technical Module

Elegance SC. Solar Control

How To Model With Cfd Using Phoenics

Case Study Family Room Renovation 3br family home, Melbourne

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

CHAPTER 11: PASSIVE SOLAR HOMES

Mechanical and Natural Ventilation

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Outline. Thermal storage for low carbon buildings. Effect of global warming on design summer year. Environment impacts of buildings

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING

Transcription:

Opening the Bonnet Prof Darren Woolf WYSINWYG 1

WYSINWYG What You See Is NOT What You Get: Looking inside the Pandora s Box Prof Darren Woolf WYSINWYG 2

WYSIWYG implies a user interface that allows the user to view something very similar to the end result What You See Simulation Outputs What You Get Real Performance WYSIMOLWYG what you see is more or less what you get - recognizing that most implementations are imperfect WYSYHYG what you see you hope you get YAFIYGI you asked for it you got it WYSINWYG 3

CONTENTS Width and depth of building simulation studies Their impact within and on the design process Case studies covering Complexities of building physics within simulation Need for planning, attention to detail, scrutiny Good communication supporting an appropriate message WYSINWYG 4

Building Physics: The engineering sciences WYSINWYG 5

Adapted from CIBSE Guide F Energy Efficiency in Buildings chapter on concept design Building physics in practice WYSINWYG 6

Holistic design and building physics skills Structural Architecture Lighting & daylighting Building Physics skills set is a toolbox of methods, models and experiences Mechanical & natural ventilation systems Facades Materials Also: Fire Wind Acoustics WYSINWYG 7

Defining your building simulation services Performance based design for indoor and outdoor spaces Low energy, high comfort levels, high air quality Environmental modelling Dynamic thermal modelling, CFD, daylight Façade analysis Moisture, condensation, thermal bridging, glass performance Mechanical and natural ventilation systems Supply and extract air conditions / configuration Configuration and size of openings Building envelope performance Down draughts, overheating risk EIA, ES Wind, sunlight WYSINWYG 8

Bounding your model: Defining geometry and physics WYSINWYG 9

Understanding the relationship between environmental variables Large pond Small water feature Pergola Large water feature Small pond Effect of wind on: Effect of air temperatures on: Thermal comfort Surface temperatures Local air movement within the garden effect of walls and terrace lounge Air temperatures (mixing) Evaporative cooling off water surfaces and features Effect of the sun on: Effect of humidity levels on: Evaporative cooling performance of still ponds and water features Thermal comfort Shading performance Surface temperatures potential radiant effects of surfaces on thermal comfort Air temperatures within the roof garden from heated surfaces WYSINWYG 10

Using indexes to explain / combine your environmental variables, not bury them March 1pm: 27 C dry bulb, 51% RH, NW wind Air temperatures Sense of thermal comfort: Very hot: Hot: Warm: Slightly Warm: Neutral: Slightly Cool: Index limits? Air velocities WYSINWYG 11

Increasing complexity through the design stages Simple geometric model (Concept) Light ray tracing (Radiance) Advanced droplet model (Scheme) CFD WYSINWYG 12

Understanding risk Advanced droplet model CFD using a droplet model representing light, medium and heavy rain Capture of local wind and surface film effects including secondary transport Improved roof canopy design (integrating performance analysis into design cycle) WYSINWYG 13

Complex facades Office DSF Outside Double Skin Façade (DSF) with vents to the side blind Double Glazed Unit (DGU) with air vents to each side (between DSF and office) Single Glazed Unit (SGU) with 30mm vertical gaps (apertures between DSF and outside) WYSINWYG 14

Using gut feeling / experienced judgements Dry-bulb T ( C) Wet-bulb T ( C) External Conditions DSF Conditions Room Conditions Wind speed (m/s) Direct rad (W/m²) Diffuse rad (W/m²) Global rad (W/m²) SGU surface T ( C) DGU surface T ( C) External Dry-bulb T Air ( C) Change Rate (l/s) early observations very small T south-facing DSF, afternoon in July Mean radiant T ( C) Operative T ( C) Dry-bulb T ( C) Mean radiant T ( C) Operative T ( C) Nat Vent Rate (l/s) Mech Vent Rate (l/s) Flowrate out of room through rear transfer grille (l/s) Flowrate into room through rear transfer grille (l/s) WYSINWYG 15

Devising a simulation strategy Simulation strategy WYSINWYG 16

Closer scrutiny using sub-models atrium internal spaces corridor Original DTM of 3 rd floor South-facing perimeter office plus DSF Checking sub model (annulus flow) - operative temperature and flow directions Extremely complex model with many variables High uncertainty with wind, solar-heat distributions, DSF performance, air movement between internal and external zones WYSINWYG 17

Understanding heat transfer detail within solar transmission s7 s5 s3 s6 s4 s2 s1 s7 s6 s5 s4 s3 s2 s1 Relative importance of different elements contribution to overall heat distribution WYSINWYG 18

Understanding surface detail within the heat distribution Each surface has two sides (two sets of surface properties) Some surfaces have only incident diffuse radiation (shaded from direct sun), some have direct plus diffuse (in sun patch) SGU (outer) Blind (outer) DGU (outer) Solid surfaces WYSINWYG 19

How were the blinds influencing the 3D heat transfer? m/s Vertically upward movement in gap between blind and DGU in CFD (not recirculating between these surfaces) Limitations of DTM, e.g. only able to attach blind to inside of SGU, HTC? How does the heat transfer through a closely coupled blind differ from a far coupled one? WYSINWYG 20

Extracting data to simplify understanding Hand calculations provided an offset to better assess predictions and increase confidence overall WYSINWYG 21

Controlling performance actuated roof vents start of solar gains starting to partially open actuated louvres 10 min time step recording at hourly intervals air T just below roof vents open area WYSINWYG 22

Controlling defaults and time steps 6 min time step recording at 6 min intervals Detailed scrutiny exposed excessive switching Default / notional air temperature band width used (1K) Modified approach for controls strategy WYSINWYG 23

Communicating results 30 Surface temperature below 0 C, risk of condensation freezing on glazing surface. 1G = single glazed unit 2G = double glazed unit 1G RH beneath skylight 50 40 20 Temp ( C) 10 2G Air T beneath skylight 2G Surface T underside of skylight 1G Air T beneath skylight 2G RH beneath skylight 1G Surface T underside of skylight 30 20 RH (%) 00 Condensation risk zone 1G Dew point T 2G Dew point T 10 00 02 04 06 08 10 12 14 16 18 20 22 24 Hours Good communication includes simulation outputs that can be easily read and understood WYSINWYG 24

Are you competent for the intended application? Level 1: Understands how to drive the software and get the results out Level 2: Successfully implements the standard test models Level 3: Understands the principles behind the software Level 4: Good knowledge of the technical manual and/or online help so that non-standard applications can be implemented Level 5: Clearly explains results at the appropriate level Level 6: Recognised supervisor on the application of the software Level 7: Implements user code Level 8: Recognised expert CIBSE Guide AM11 Building Performance Modelling (2015 to be published soon) WYSINWYG 25

Some ideas for graduates Sensitivity test 1D solar and thermal transmission calculations to better understand heat transfer mechanisms / g-value / U-value formulation at surface property level Build box models to test application, sensitivities and tolerances of software application for single physics, e.g. long wave radiation Examine how your software deals with convective and radiative components of internal heat gains and how the heat is distributed Think about statistical positioning of climate data and potential impact of using different targets WYSINWYG 26

Turning WYSINWYG into WYSIWYG Education Education Education! (understanding and training) Application Application Application! (what s appropriate and practical in budget and time?) Defaults Defaults Defaults! (watch out for and understand the ) Limitations Limitations Limitations! (know and explain your + assumptions + simplifications) Interpretation Interpretation Interpretation! (a measured sale of your message is a valued one) Black Box = Blind Box = Pandora s Box! YAFIYGI WYSINWYG 27

Any Questions? WYSINWYG 28