CSA GROUP 8501 EAST PLEASANT VALLEY ROAD CLEVELAND, OHIO 44131

Similar documents
CANADIAN STANDARDS ASSOCIATION OPERATING AS CSA GROUP 178 REXDALE BOULEVARD TORONTO, ONTARIO M9W 1R3 CANADA

This is to attest that

CSA Group and Certification Marks

California HERO Program Residential Eligible Product List

Energy Efficiency Testing for HVAC/R Helping you comply with energy efficiency regulatory programs

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS: Section 1. Article V of Chapter XII of the Los Angeles Municipal Code is added to read:

Georgia State Amendments to the International Plumbing Code

Green Built Texas Protocol v3 Project Summary and Checklist, One and Two Family New Construction

WaterSense or Energy Star. Tank type toilets: WaterSense = 1.28 gpf (4.8L) with at least 350 gram waste. 1.5 gpm maximum & 0.8 gpm minimum at 20 psi

CHAPTER 9: WATER HEATING

WATER. Water Management Protect your building from water damage. Intent. Information & Tips

Federal Tax Credits for Energy Efficiency

New Technologies New Savings. Water Heater Market Profile U.S. Department of Energy

Water Efficiency Obtain EPA WaterSense Certification At Final Inspection. Verifier Verifier confirms presence by visual inspection.

Introduction. Kitchens

City of Elk River BASEMENT Office Use Only

Category Measure Minimum Efficiency / Certification Requirements

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

How To Build A Basement House

Arapahoe County Residential Water Heater Installation and Inspection Guide

Shop Maryland Energy Weekend for Certain Energy Efficient Appliances

PLBG/GAS SAFETY Information Bulletin

Ethanol Vehicle and Infrastructure Codes and Standards Citations

It Pays. To Save Energy FPO. Guide to Xcel Energy rebates, incentives and programs for residential customers in Minnesota

Montgomery County Health Department Mobile Food Guidelines. Definitions

Safety, Health and Accessibility Design Guidelines For Architects, Engineers and Design Firms

Selecting a New Water Heater

Energy Efficiency for the Homeowner

Section 1. The title of Section of Subchapter A of Chapter 100 of Title 1 of the Rules of the City of New York is amended to read as follows:

A Do-It-Yourself Home Water Audit

ENERGY AUDITS AND RETRO- COMMISSIONING Local Law 87

Residential Contractor Partnership Program Application EnergySmart and Denver Energy Challenge Programs

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

Energy Efficiency and Renewable Program Offerings

Energy Efficiency Evaluation Reportii House file number: 9900D00001ii

Hot Water Heating: Technologies and Use

Smart Ideas(R) Energy Efficiency Program for ComEd Customers

Rules of Thumb Energy Efficiency in Buildings

Exhibit IV Approved Measures List. Page 1 of 5

Training Course Catalog

PARTNERING. in Energy. Solutions A PROGRAM TO PROMOTE BUSINESS ENERGY EFFICIENCY

CHAPTER 10: APPLIANCES AND LIGHTING

Chapter 5 Water, Plumbing, and Waste

WATER HEATERS. If your water heater tank is leaking, then your course is clear: buy a new unit. But if it isn t, your answer is less obvious.

INTERNATIONAL RESIDENTIAL PLUMBING CODE

How to Reduce Energy Costs in Your Commercial Building

Training course catalog

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

PARTNERING. in Energy. Solutions A PROGRAM TO PROMOTE BUSINESS ENERGY EFFICIENCY

Effective Date: March Rev. 5/29/2015- Void After: March Product: Ceramic Plumbing Fixtures File No. 3360

Corporate Office Energy Efficiency Initiatives

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION

CSA Group OHS Standards. Institute for Work and Health April 1, 2014

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

NORTH CAROLINA INCENTIVES

1 RCNY CHAPTER 100

Exhibit B. Property Acquisition and Disposition Division Residential Design & Performance Standards

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

What to Expect From the Examination. How to Study the Plumbing Codes

energy-saving checklist a guide for rental property owners

CHAPTER 26 HEATING, AIR CONDITIONING AND REFRIGERATION COMMISSION AND CONTRACTORS

Backflow Bulletin #1

Whistler Green: Project Checklist

Sample DTE Energy Rebate Programs Follow:

South Central Service Center

Flood Risk Considerations

ENERGY STAR WATER HEATER MARKET PROFILE EFFICIENCY SELLS U.S. DEPARTMENT OF ENERGY

Georgia State Amendments to the International Plumbing Code

ENERGY EFFICIENCY ENERGY EFFICIENCY: Saving Dollars While Clearing the Air

City of Houston Mechanical Code

EMERGENCY EYEWASH AND SHOWERS 29 CFR Part (c)

How To Make A House Safe

SITE INSPECTION CHECKLIST

Japan s Energy Efficiency and Conservation Policy Updates. Naoko Doi Institute of Energy Economics, Japan

HOMEOWNER S PERMIT GUIDE

2014 APPLIANCE EFFICIENCY REGULATIONS

High Efficiency Heating

Plumbing Identification and Damage Assessment Guide

INFORMATION BULLETIN 121c Requirements for Plumbing Limited Service and Repair Permits (LSR)

Schedule of Maintenance Fees

Plumbing Lesson One: Help! Call the Plumber. Student Handouts

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

Transcription:

This is to attest that CSA GROUP 8501 EAST PLEASANT VALLEY ROAD CLEVELAND, OHIO 44131 Testing Laboratory TL-266 has met the requirements of the IAS Accreditation Criteria for Testing Laboratories (AC89), has demonstrated compliance with ISO/IEC Standard 17025:2005, General requirements for the competence of testing and calibration laboratories, and has been accredited, commencing April 11, 2016, for the test methods listed in the approved scope of accreditation. (See laboratory s scope of accreditation for fields of testing and accredited test methods.) This accreditation certificate supersedes any IAS accreditation bearing an earlier effective date. The certificate becomes invalid upon suspension, cancellation or revocation of accreditation. See http://iasonline.org/more/search.html for current accreditation information, or contact IAS at 562-364-8201. C.P. Ramani, P.E., C.B.O President

IAS Accreditation Number: Accredited Entity: Address: Contact Name: TL-266 CSA Group 8501 E. Pleasant Valley Rd. Cleveland, OH 44131 Benjamin Barker Manager, Accreditations Telephone: 416-747-4013 Effective date of Scope of Accreditation: April 11, 2016 Accreditation Standard: ISO/IEC 17025:2005 FIELDS OF TESTING Electrical Products Fuel Burning Appliances and Components 174, 372, 412, 429, 465, 467, 484, 559, 574, 732, 834, 858, 873, 921, 991, 1004, 1020, 1042, 1054, 1081, 1096, 1240, 1261, 1278, 1453, 1556, 1598, 1698, 1995 and 2021; C22.2 Nos. 61, 100, 139 and 250; CSA/ 61010-1, 60950-1 and S82.02.01; IEC Standard 60920 Energy Storage Standards (Batteries) ANSI/NEMA Standards C18.1 Parts 1 and 2, C18.2 Parts 1 and 2, C18.3 Parts 1 and 2 CSA Standard E62133 EN/IEC Standards 60086-1, -2, -3, -4, and -5; 62133; 61951-1 and -2; 62660-1, -2; 62281 642, 1973, 1989, 2054, 2575 and 62133 ANSI/CSA, ANSI/CGA and ANSI/ ANSI Standards Z21.1, Z21.5.1/CSA 7.1, Z21.5.2/CSA 7.2, Z21.10.1/CSA 4.1, Z21.10.3/CSA 4.3, Z21.11.2, Z21.12, Z21.13/CSA 4.9, Z21.15/CSA 9.1, Z21.17/CSA 2.7, Z21.18/CSA 6.3, Z21.19/CSA 1.4, Z21.20/CSA C22.2 No. 199/UL 372, Z21.23, Z21.42, Z21.57; Z21.21/CSA 6.5, Z21.22/CSA 4.4, Z21.24/CSA 6.10, Z21.35/CSA 6.8, Z21.40.1/CGA 2.91, Z21.40.2/CGA 2.92, Z21.40.4/CGA 2.94, Z21.41/CSA 6.9, Z21.47/CSA 2.3, Z21.50/CSA 2.22, Z21.54/CSA 8.4, Z21.56/CSA 4.7, Z21.58/CSA 1.6, Z21.60/CSA 2.26, Z21.61, Z21.63/CSA 11.3, Z21.66/CGA.6.14, Z21.69/CSA 6.16, Z21.71, Z21.72/CSA 11.2, Z21.73/CSA 11.1, Z21.74, Z21.75/CSA 6.27, Z21.76, Z21.77/CSA 6.23, Z21.78/CSA 6.20, Z21.79/CGA 6.21, Z21.80/CSA 6.22, Z21.81/CSA 6.25, Z21.83, Z21.84, Z21.86/CSA 2.32, Z21.87/CSA 4.6, Z21.88/CSA 2.33, Z21.89/CSA 1.18, Z21.90/CSA 6.24, Z21.91, Z21.92/CSA 6.29, ANSI Z21.101/CSA 8.5, Z83.4/CSA 3.7, Z83.7/CSA 2.14, Z83.8/CSA 2.6, Z83.11/CSA 1.8, Z83.18, Z83.19/CSA 2.35, Z83.20/CSA 2.34, Z83.21/CSA C22.2 No. 236/UL 921 and Z83.26/CSA 2.37; ANSI/CSA America PRD 1, and ANSI/CSA America FC 3; Page 2 of 5

Fuel Burning Appliances and Components (cont d.) Hazardous Locations ANSI/ASME Standards B16.33, B16.38, B16.40 and B16.44; ANSI/ 44, 252, 429, 536, 1002, and 1054; NGV Standards ANSI/CSA NGV 1, ANSI NGV 2, ANSI/AGA NGV 3.1/CGA 12.3; ANSI/IAS NGV 4.1/CSA 12.5, ANSI/IAS NGV 4.2/CSA 12.52, ANSI/IAS NGV 4.4/CSA 12.54, ANSI/IAS NGV 4.6/CSA 12.56; and ANSI NGV 4.8/CSA 12.58, ANSI LC Series Standards ANSI LC1/CSA 6.26, ANSI/IAS LC2, ANSI/CSA LC3, ANSI LC 4, and ANSI LC 6; 125, 132, 197, 244A, 296, 307B, 353, 378, 396, 427, 441, 462, 495, 567, 569, 726, 727, 729, 730, 731, 732, 733, 795, 969, 1075, 1584, and 2034; CAN, CGA and CAN/CGA Standards CAN Standards CAN 6.19, CAN1-1.1, CAN1-2-20, CAN1-2.23, CAN1 3.1, CAN1-8.1, CAN/CGA 8.3, CGA 1.3, CGA 2.29, CGA 3.2, CGA 3.3, and CGA 3.4; 3.8, B140.2, B140.4, B140.7, B140.8, B140.9.3, and B140.12; CSA Group Requirements 1.95, 1.99 US, 2.03 US, 2.94 US, 4.01 US, 4.96 US, 4.98 US, 5.01 US, 7.89 US, 8.94 US, 8.96 US, 9.96 US and 10.96 US; Australian Standards AS 4551 (Amendments 1 and 2), AS 4554, AS 4557 (Amendments 1 and 2) and AS 4563; International Approval Service (IAS) Standards U.S. Requirements 1-89, 1-91, 1-94, 2-87, 2-90, 2-93, 3-90, 3-91, 3-92, 3-93, 4-90, 5-94, 6-90, 6-96 and 12-94; SAE Standards SAE Surface Vehicle Standard J343 and SAE 100R Series, SAE Surface Vehicle Standard J517; ASCE 25, CR 90-002. ANSI/ISA Standards 12.12.01, 12.27.01, 60079-0 (12.00.01), 60079-1 (12.22.01), 60079-2 (12.04.01), 60079-5 (12.00.04), 60079-6 (12.00.05), 60079-7 (12.16.01), 60079-11 (12.02.01), 60079-15 (12.12.02), 60079-18 (12.23.01), 60079-25 (12.02.05), 60079-26 (12.00.03), 60079-27 (12.02.04), 60079-31 (12.10.03), 61241-0 (12.10.02), 61241-1 (12.10.03), 61241-2 (12.10.06), 61241-11 (12.10.04) and 61241-18 (12.10.07); ANSI/IEC Standard 60529; IEC Standards 60079-0; 60079-1, 60079-2, 60079-5 60079-6, 60079-7, 60079-11, 60079-15; 60079-18, 60079-25, 60079-26, 60079-31, 60529, 61241-0, 61241-1, 61241-4, 61241-11 and 61241-18; CAN/ C22.2 Nos. 60079-0, 60079-1, 60079-2, 60079-5, 60079-6, 60079-7, 60079-11, 60079-15, 60079-18, 60079-31, 60529, 61241-4; 25, 30, 130, 137, 145, 157, 159, 174 and 213; Page 3 of 5

Hazardous Locations (continued) Plumbing Products EPA WaterSense Specifications ENERGY STAR Program Requirements ANSI/ 60079-0, 60079-1, 60079-5, 60079-6, 60079-7, 60079-11, 60079-15, 60079-18, 674, 823,844, 913 and 1203; NFPA Standard 496; FMRC Standards 3600, 3610, 3611, 3615, 3616 and 3620 ASTM Standards C1173 and F1807; ASME and ASME/ A112.18.1/CSA B125.1, A112.18.2/CSA B125.2, A112.18.3, A112.19.4, A112.1002/CSA B125.12, A119.2/CSA B45.1, A119.1/CSA B45.2, CSA B45.3; A119.3/CSA B45.4; B45.0, B45.1, B45.2, B45.3, B45.4, B45.5, B45.6, B45.7, B45.8, B45.9, B45.10, B45.11, B64.0, B64.1.1, B64.1.2, B64.2, B64.2.1, B64.2.1.1, B64.2.2, B64.3, B64.3.1, B64.4, B64.4.1, B64.4.5, B64.4.5.1, B64.6, B64.6.1, B64.7, B64.8, B64.9, B70, B125.1, B125.2, B125.3, B137.0, B137.1, B137.2, B137.3, B137.4, B137.4.1, B137.5, B137.6, B137.8, B137.9, B137.10, B137.11, B137.12, B356 and B602; ASSE Standards 1001, 1002, 1003, 1005, 1010, 1011, 1012, 1013, 1014, 1015, 1016, 1017, 1018, 1019, 1020, 1022, 1024, 1025, 1035, 1037, 1044, 1047, 1048, 1051, 1052, 1053, 1056, 1061, 1062, 1066, 1069, 1070 and 1071; PDI Standard PDI-WH 201 EPA WaterSense Specifications for Showerheads; EPA WaterSense Specification for Tank Type High Efficiency Toilet Specification; EPA WaterSense Specification for Flushing Urinals; EPA WaterSense Specification for High Efficiency Lavatory Faucet Specification; EPA WaterSense Commercial Pre Rinse Spray Valves ASSE 1018, 1061 and 1071 Residential Refrigerators for Residential Refrigerators and Freezers, Version 4.1 10 CFR 430, Subpart B, Appendix A, A1 Residential Freezers for Residential Refrigerators and Freezers, Version 4.1 10 CFR 430, Subpart B, Appendix B, B1 Commercial Refrigerators and Freezers for Commercial Refrigerators and Freezers ANSI/ASHRAE Standard 72, ANSI/AHAM HRF-1 Page 4 of 5

ENERGY STAR Program Requirements (continued) Energy Efficiency Mechanical Water Heaters (Storage, Tankless, Heat pump and Solar Heaters) for Residential Water Heaters 10 CFR 430, Subpart B, Appendix E ASHRAE 118.2, Section 11.24 Solar Rating and Certification Corporation (SRCC) OG-300 certification Boilers for Boilers 10 CFR Part 430, Appendix N (Electronic Code of Federal Regulations) ANSI/ASHRAE 124, Methods of Testing for Rating Combination Space-Heating and Water-Heating Appliances Furnaces ENERGY STAR Program Requirements for Furnaces Partner Commitments 10 CFR Part 430, Appendix N Dehumidifiers for Dehumidifiers Eligibility Criteria CAN/CSA-C749, Performance of Dehumidifiers ANSI/AHAM Standard DH-1, Clauses 4, 5, and 7 Vending Machines for Refrigerated Beverage Vending Machines ASHRAE Standard 32.1, Methods of Testing for Rating Vending Machines for Bottled, Canned, and Other Sealed Beverages Ice Machine ENERGY STAR Program Requirements for Commercial Ice Machines Ceiling Fans ENERGY STAR Program Requirements for Residential Ceiling Fans CSA Standard C814, Energy Performance of Ceiling Fans AHRI-BTS-2000 Method to Determine Efficiency of Commercial Space Heating Boilers ANSI/UL Standard 969; CSA C22.2 No. 0.15 Marking and Labeling Systems Page 5 of 5