Green Built Texas Protocol v3 Project Summary and Checklist, One and Two Family New Construction

Size: px
Start display at page:

Download "Green Built Texas Protocol v3 Project Summary and Checklist, One and Two Family New Construction"

Transcription

1 Date of Application Path Project Identification Project Address Owner Identification Architect Identification Contractor Identification Third Party Provider Green Built Texas Protocol v3 Project Summary and Checklist, One and Two Family New Construction Summary Permit. Provider. Building Code IRC IBC Residential Occupancy Type of Building Single Family Duplex Townhouse** IBC Group R Occupancy: (circle one) R-1. R-2. R-3. R-4 Number of: Stories: Bedrooms: Baths: Garage Attached Detached Carport ne Building Sq. Lot Size: Building Total Area Under Roof: Total nroof Area: Footage Sq. Ft: IECC Climate Zone 3A Radon Zone: 3* Green Built Texas All requirements mandatory Protocol V 3.0* te: Checklist is intended for use with projects complying with the Dallas Green Construction Code for one and two family dwelling units following the Green Built Texas protocol path. Project seeking Green Built Texas certification must be verified by a certified Green Built Texas verifier in addition to the required plan reviews and inspections performed by a City of Dallas approved Third Party Green Building Provider and an approved Third Party Energy Inspector. * Radon Zone: Dallas lines within Radon Zone 3 - Radon; the potential exists for building and raw materials from radon zoned areas to be brought into the Dallas area for use on projects ** Townhouse: As defined by the Dallas Residential Code; may not be multifamily building City of Dallas Green Building Program, Phase 2 Page 1

2 Green Built Texas Protocol V3 Plan Item Review/ Water Efficiency 1 or Obtain EPA WaterSense Certification Submit copy of certification 2 Irrigation System: Equip system with smart controller (rain, and soil moisture sensors or Indicate controller system weather forecast based (ET) irrigation controller 3 Landscape and turf planting limited to drought tolerant species 4 2 inch deep mulch in landscape beds 5 Water efficient toilets, work on first flush, 1.3 gpf 6 Hot Water Reduction Select one of 3 strategies; Strategy 1: Maximum 30 ft hot water pipe run to kitchen and baths and sized per plumbing code Strategy 2: Piping system design: Select one system design 1. Structured type plumbing with demand control hot water loops 2. Engineered parallel piping system 3. Central core plumbing system with all plumbing fixture fittings located so volume of water between the water heater and fixture fittings is 6 cup maximum Strategy 3: Pipe runs in excess of 30 ft from water Select one option heater to fixture locations: 1. Tankless hot water heater installed at point of use and served by cold water 2. On demand hot water recirculation system 3. Pipes insulated to minimum R3; Circulating hot water piping insulated to minimum R2 7 Energy Star Dishwasher Review supporting documentation City of Dallas Green Building Program, Phase 2 Page 2

3 8 Water Conservation: Implement minimum two Review supporting documentation of following 2 strategies or install rain water catchment system for minimum of 50% of landscape irrigation needs Strategy 1: High performance fixtures Select minimum 2 of 4 Lavatory faucet flow rates equal to or less than 1.5 gpm Kitchen and utility faucet flow rates equal to or less than 2.2 gpm Showerhead flow rates equal to or less than 2.0 gpm Lavatory faucets have infrared sensors Strategy 2: Zone irrigation system separately for turf and slab/bedding areas Strategy 3: Install low volume, nonspray irrigation system Drip irrigation Bubblers Drip emitters Soaker hose Subsurface irrigation irrigation system Select one or more types City of Dallas Green Building Program, Phase 2 Page 3

4 Indoor Air Quality 1 or Obtain EPA Indoor Air Plus Certification Submit copy of certification 2 1a. Comply with Energy Star Version 3.0 HVAC Quality Installation requirements 1b. OR implement all of the following 1) Heating and cooling design loads for each room comply with ACCA Man J, ASHRAE Handbooks or equivalent software a) Heating and cooling equipment sized appropriately; meet design loads. ENERGY STAR HVAC QI Certificate submitted b) OR Verification of all the following: (1) Design load calculations (2) System design (3) Verification that outdoor and indoor coils match per AHRI Directory of Certified Product Performance 2a. Comply with Energy Star Version 3.0 HVAC Quality Installation requirements Select 1a or 1 b. Submit copy of Energy Star QI certification Submit design load calculations and report documentation Select 2a or 2b Submit documentation 2b. OR implement all of the following: 1) Heating and cooling design loads for each room comply with ACCA Man J, ASHRAE Handbooks or equivalent software a) Heating and cooling equipment sized appropriately; meet design load Submittal: ENERGY STAR HVAC QI Certificate City of Dallas Green Building Program, Phase 2 Page 4

5 2 Cont b) OR verification of following: (1) Design load calculation (2) System design (3) Verification that outdoor and indoor coils match per AHRI Directory of Certified Product Performance 2) Sealed duct system(s) designed per ASHRAE ACCA Manual D or equivalent software and installed airtight, properly balanced, and protected from construction debris or submit verification of all prescriptive requirements or Performance Test Alternative: a) Design verified by documentation b) Verify duct system complies with: (1)Seams in HVAC cabinet, plenum, and adjacent ductwork sealed with mastic systems, tape per UL 181A or UL 181B, or gasket systems. (2) Building cavities are not used as part of forced air supply or return systems (3) Duct openings covered during construction or thoroughly vacuumed prior to installation of registers, grilles, and diffusers Submit ENERGY STAR HVAC QI Certificate City of Dallas Green Building Program, Phase 2 Page 5

6 2 cont Performance Test Alternative: a) Room by room airflows balanced and verified within +/-20% of calculated room airflows to meet design loads, except for baths, closets, and pantries b) Duct system total leakage test no greater than 6 cfm per 100 s.f. of floor area (or 9% design fan flow), measured at 25 Pa, with duct boots and air handler in place, according to ASTM E1554, ASHRAE 152 or RESNET approved method 3. Mechanical whole house ventilation complies with ASHRAE a) Whole house mechanical ventilation system and controls deliver prescribed outdoor air ventilation rate (ASHRAE 62.2 section 4), including ventilation restrictions in ASHRAE 62.2 section 4.5 b) Transfer air is not used for ventilation requirements (ASHRAE 62.2 section 6.1) c) Outdoor air inlets located minimum 10 ft. from contaminant sources (ASHRAE 62.2 section 6.8) d) Airflow tested and meeting rated fan airflow at 0.25 in. w.c. OR ducts sized per ASHRAE 62.2 Table 7.1 and manufacturer s design criteria (ASHRAE 62.2 section 7.3) City of Dallas Green Building Program, Phase 2 Page 6

7 2 cont 4. Room pressure differentials minimized by transfer grilles or jump ducts for closed rooms without dedicated return, except baths, kitchens, closets, pantries, and laundry rooms a) Opening Size: 1 square inch capacity (grille area) per cfm of supply (including free area undercut below door as part of the area) b) Performance Test Alternative: Measured pressure differential no greater than 3 Pa (0.012 in. w.c.) between closed rooms and adjacent spaces with return te: Outdoor air ducts connected to the return side of an air handler permitted as supply ventilation if manufacturers requirements for return air temperature are met 3 Gas Furnaces and Water Heaters: Sealed combustion type or vented to outdoors if located in conditioned space 4 air handling equipment of ductwork located in garage 5 Mechanical exhaust vented to outdoors for Review drawings; visually inspect to extent possible each bathroom and kitchen (ASHRAE 62.2) 6 Garage Detached or Isolate from conditioned space; seal, gasket door between garage and conditioned space; continuous air barrier between walls and ceilings separating garage from conditioned space 7 HVAC set to maintain Relative Humidity at or below 60% by: a) Additional dehumidification system or b) Central HVAC equipped with controls for dehumidification mode 8 Combustion air for wood burning fireplaces Review drawings, visually inspect to extent possible from outside and install glass door or sealed combustion fireplace 9 Water based mastic for sealing ducts ; visually inspect 10 AC Return Filters: Minimum MERV 8; no visible bypass between filter and filter rack City of Dallas Green Building Program, Phase 2 Page 7

8 11 For home with combustion appliances or attached garage, carbon monoxide alarm in sleeping area, hardwired with battery back up, located per NFPA 730, certified by CSA 5.19 or UL 2034 te: In addition to above, implement any 2 strategies of the following to enhance indoor air quality 12 Strategy 1: Carpets, paddings, and adhesives compliant with emission levels in accordance with the Carpet and Rug Institute s (CRI) Green Label or Green Label Plus indoor air quality program 13 Strategy 2: Interior paints and finishes, including minimum 90% applied to interior surfaces of homes certified as low VOC or no VOC by one of the following: Green Seal Standard GS-11, or Greenguard Certification for Paints and Coatings, or Scientific Certification Systems (SCS) Standard EC , Indoor Advantage Gold, or Master Painters Institute (MPI) Green Performance Standards GPS-1 or GPS-2, or A third party low emitting product list based on CA Section Strategy 3: Central vacuum (canister unit) Review drawings, visually inspect outside conditioned space 15 Strategy 4: Structural plywood and OSB certified compliant with PS1 or PS2, as appropriate, and made with moisture resistant adhesives as indicated by Exposure 1 or Exterior on the American Plywood Association (APA) trademark. Hardwood plywood certified compliant with the formaldehyde emissions requirements of ANSI/HPVA HP and U.S. HUD Title 24, Part 3280 or certified compliant with CA Title 17 during construction to extent possible City of Dallas Green Building Program, Phase 2 Page 8

9 16 Strategy 5: Particleboard and MDF certified compliant with the formaldehyde emissions requirements of ANSI A208.1 and A208.2, respectively, and U.S. HUD Title 24, Part 3280, or certified compliant with EPPS CPA 3-08 by CPA Grademark certification program or certified compliant with CA Title Strategy 6: Cabinetry contains no added urea formaldehyde and made with component materials certified to comply with appropriate standards listed in Strategies 5 or 6 or registered brands or produced in registered plants certified under KCMA s Environmental Stewardship Certification Program 18 Strategy 7: AC return filtration upgraded to minimum 4 inch pleated or MERV 9 or greater (in lieu of item 9); no visible bypass between filter and filter rack; filter compatible with and accounted for in HVAC design calculations during construction to extent possible during construction to extent possible during construction to extent possible Energy Efficiency 1 Strategy 1: HERS Index of 85 or below Submit copy of report/certification 2 Strategy 2: ENERGY STAR Version 3.0 certification Durability and Moisture Management 1 Energy Star Version 3.0 Water Management System Checklist Homeowner Education 1 Homeowner operations and maintenance kit and perform walk through. 2 Homeowner provided with information on local recycling programs, green energy service providers, and Green Built Texas registration process Submit copy of certification, copy of checklist Copy of homeowner manual, document attesting to walk through Copy of homeowner information End of Green Built Texas Path Checklist City of Dallas Green Building Program, Phase 2 Page 9

Water Efficiency Obtain EPA WaterSense Certification At Final Inspection. Verifier Verifier confirms presence by visual inspection.

Water Efficiency Obtain EPA WaterSense Certification At Final Inspection. Verifier Verifier confirms presence by visual inspection. Green Built Texas Guidelines Version 3.0 (established by the Texas Home Energy Raters Organization) WATER EFFICIENCY Obtain EPA WaterSense Certification confirms presence by visual inspection. OR Implement

More information

Exhibit B. Property Acquisition and Disposition Division Residential Design & Performance Standards

Exhibit B. Property Acquisition and Disposition Division Residential Design & Performance Standards Exhibit B Property Acquisition and Disposition Division Residential Design & Performance Standards I. Introduction The Property Acquisition and Disposition Division ( PADD ) has developed design standards

More information

Building Performance Solutions HVAC Design Guide, 2007

Building Performance Solutions HVAC Design Guide, 2007 Building Performance Solutions HVAC Design Guide, 2007 HVAC sizing, system design, layout, and installation shall be sized according to (Air Conditioning Contractor of America), ACCA manual J8, 8 th edition,

More information

LEED for Homes Rating System

LEED for Homes Rating System LEED for Homes Rating System market rate affordable multi-family TARGET MARKET REGULATIONS typical building practices 70% The top 25% of new homes based on performance and environmental responsibility

More information

GUIDELINES for BUILDING ENERGY EFFICIENT NEW HOMES with the URA. November 3, 2010 - Version 2.0

GUIDELINES for BUILDING ENERGY EFFICIENT NEW HOMES with the URA. November 3, 2010 - Version 2.0 GUIDELINES for BUILDING ENERGY EFFICIENT NEW HOMES with the URA November 3, 2010 - Version 2.0 Welcome The Urban Redevelopment Authority of Pittsburgh (URA) is the City of Pittsburgh s economic development

More information

Residential Duct Systems for New and Retrofit Homes

Residential Duct Systems for New and Retrofit Homes Residential Duct Systems for New and Retrofit Homes Why it is important to properly design and install high quality, efficient ducted air systems? The efficiency of air distribution systems has been found

More information

California HERO Program Residential Eligible Product List

California HERO Program Residential Eligible Product List ALL PRODUCTS In addition to the HERO Product Eligibility Specifications listed below, all product specifications and installation quality must meet or exceed applicable local, state, and/or federal permitting,

More information

CASE STUDY: The EVERGREEN

CASE STUDY: The EVERGREEN CASE STUDY: The EVERGREEN 1691 Palm Ave Summary Information Type: Residential Occupancy: Single Family Residence Size: 3,075 square feet Completed: 2009 Owner: Rob and Denise Smith Developer: E2 Homes,

More information

Whistler Green: Project Checklist

Whistler Green: Project Checklist Whistler Green: Project Checklist (Detached and duplex dwellings) Whistler Green is our community standard for healthy homes that use energy and resources efficiently in a mountain setting. Considered

More information

MSHDA Affordable Green Enterprise Green Communities USGBC LEED

MSHDA Affordable Green Enterprise Green Communities USGBC LEED TAB M The ("QAP") is designed to further the Authority's mission by providing a process to allocate Low Income Housing Tax Credits ("LIHTC") to developments promoting safe, decent, affordable housing.

More information

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715, 4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.

More information

Table of Contents. Page ii

Table of Contents. Page ii Table of Contents Page i Table of Contents 9. Additions, Alterations and Repairs... 1 9.1 Introduction... 1 9.1.1 Additions... 2 9.1.2 Alterations... 2 9.1.3 Repairs... 3 9.2 What s New in the 2013 Standards...

More information

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances. Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org

More information

IECC Compliance Guide for Homes in Virginia

IECC Compliance Guide for Homes in Virginia IECC Compliance Guide for Homes in Virginia Amended Version of 2012 International Energy Conservation Code July 14, 2014 Climate Zone Since the entire state of Virginia falls in the IECC Climate Zone 4,

More information

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check #1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check Zoning laws Deed restrictions on home size, foundation style, roof pitch, etc. Suitability (slope, wetland issues, etc.) Accessibility

More information

Heating, Ventilation and Air-Conditioning (HVAC)

Heating, Ventilation and Air-Conditioning (HVAC) Heating, Ventilation and Air-Conditioning () Energy Code Requirements The energy requirements of the building code that apply to installations (ECCCNYS Section 503) are in addition to any plumbing, mechanical,

More information

Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668

Inspection Report. Dream Home Inspections. www.timinspects.com. 415 Second Ave. Frisco CO 80443-1789 (970) 368-2668 Inspection Report Property Address: 123 Dream Home Way Frisco, CO 80443 Prepared for: Inspector: Tim Nixon Tim Nixon Inspection date: 3/28/2014 1 of 9 General Information Property Information Address:

More information

ENERGY STAR Certified Homes, Version 3 Cost & Savings Estimates

ENERGY STAR Certified Homes, Version 3 Cost & Savings Estimates November 1, 2013 Contents ENERGY STAR Certified Homes, Version 3 Section 1: Executive Summary... 3 Section 2: Detailed Incremental Cost Estimates... 6 Section 3: Incremental Cost & Savings of the Thermal

More information

How To Build A Basement House

How To Build A Basement House Single Family Basement Finish Purpose of Guide The purpose of this guide is to assist you in the permit process for your project. This handout is intended as a basic plan submittal under the 2009 International

More information

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen May 2008 Wisconsin Area PO BOX 115 Lake Geneva, WI 53147 CELL (414) 550-4765 Home Performance with ENERGY STAR Evaluation Report Customer

More information

Arapahoe County Residential Water Heater Installation and Inspection Guide

Arapahoe County Residential Water Heater Installation and Inspection Guide Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however

More information

CASE STUDY: 1810 Via Palermo, Winter Park, FL 32789

CASE STUDY: 1810 Via Palermo, Winter Park, FL 32789 CASE STUDY: 1810 Via Palermo, Winter Park, FL 32789 Summary Information Type: Residential Occupancy: Single Family Residence Size: 3,280 square feet Completed: March 2012 Architect, Builder & Interior

More information

FLORIDA SOLAR ENERGY CENTER

FLORIDA SOLAR ENERGY CENTER FLORIDA SOLAR ENERGY CENTER Creating Energy Independence High Performance Existing Homes Partnerships and Research Janet McIlvaine Research Analyst, Florida Solar Energy Center A Research Institute of

More information

FAQ : 2011 ENTERPRISE GREEN COMMUNITIES CRITERIA

FAQ : 2011 ENTERPRISE GREEN COMMUNITIES CRITERIA FAQ : 2011 ENTERPRISE GREEN COMMUNITIES CRITERIA GENERAL QUESTIONS Q : Where can I locate the 2011 Enterprise Green Communities Criteria on the Enterprise website? A : The 2011 Online Criteria can be found

More information

Indoor airplus. Indoor Air Quality (IAQ)

Indoor airplus. Indoor Air Quality (IAQ) Indoor airplus Construction Specifications Indoor Air Quality (IAQ) About the Indoor airplus Construction Specifications These specifications were developed by the U.S. Environmental Protection Agency

More information

BUILDING SAFETY UNIT

BUILDING SAFETY UNIT POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential

More information

Development Services City of Lawrence, KS

Development Services City of Lawrence, KS Development Services City of Lawrence, KS Building Planning Table R301.2 (1) Climatic & Geographic Design Criteria Building Planning The design criteria for wind speed increased from 90 MPH to 115 MPH.

More information

Single Family Residential Basement Finish

Single Family Residential Basement Finish How to Use This Guide Building Guide Pottawattamie County Planning & Development Department Building & Safety Division Single Family Residential Basement Finish Provide two (2) sets of plans and complete

More information

BUSINESS, TRANSPORTATION AND HOUSING AGENCY CALIFORNIA DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT

BUSINESS, TRANSPORTATION AND HOUSING AGENCY CALIFORNIA DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT BUSINESS, TRANSPORTATION AND HOUSING AGENCY CALIFORNIA DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT Division of Financial Assistance Administers more than 20 programs awarding loans and grants to hundreds

More information

2015 1322) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY

2015 1322) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY MINNESOTA ENERGY CODE COMPLIANCE COLLABORATIVE 2015 Minnesota Residential Energy Code (MR 1322) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY (July 15, 2015 Update) Note: The following information contains

More information

Applications for building permits will not be reviewed until all of the required information has been submitted.

Applications for building permits will not be reviewed until all of the required information has been submitted. NOTICE: Applications for building permits will not be reviewed until all of the required information has been submitted. Once all items are submitted a minimum of ten (10) working days are required to

More information

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades Success with 2015 IECC Northeast & Mid-Atlantic Checklist for Builders & Trades COPYRIGHT 2015 ADVANCED ENERGY. ALL RIGHTS RESERVED TEMPLATE 2015.1.0 PAGE 1 CHECKLIST: JOB READY 1. 2. 3. 4. 5. 6. 7. 8.

More information

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings SUCCESS WITH 2012 IECC DELAWARE Recommended Practices for Optimized Energy Savings for Builders & Trades COPYRIGHT 2015 ADVANCED ENERGY. ALL RIGHTS RESERVED VERSION 2015.1.0 CHECKLIST: JOB READY 1. 2.

More information

ECHO System for Basements

ECHO System for Basements ECHO System for Basements Homeowners looking for more space are all too familiar with the cold, damp and dingy basement. Now, the Enclosure Conditioned Housing (ECHO) System TM, winner of the Ottawa-Carleton

More information

125 Mount Auburn Second Floor Office Renovation LEED-CI Silver, September 2008

125 Mount Auburn Second Floor Office Renovation LEED-CI Silver, September 2008 125 Mount Auburn Second Floor Office Renovation LEED-CI Silver, September 2008 The Harvard Law School s 125 Mount Auburn office renovation project team was committed to sustainable design and construction,

More information

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).

This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained). CITY OF MILPITAS Building & Safety Department 455 E. Calaveras Blvd. Milpitas, CA 95035 408-586-3240 www.ci.milpitas.ca.gov RESIDENTIAL AIR CONDITIONING, REPLACEMENT 1. PERMIT INFORMATION: The replacement

More information

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS St. Louis County Department of Public Works Division of Code Enforcement KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the

More information

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 31.00: CARBON MONOXIDE ALARMS Section 31.01: Purpose and Scope 31.02: Definitions 31.03: General Installation Provisions 31.04: Specific Installation Provisions 31.05: Carbon Monoxide Protection:

More information

Key energy-efficient features of your new home

Key energy-efficient features of your new home Key energy-efficient features of your new home Your thermal envelope The thermal envelope, or shell, of your home (walls, roof and floor) is designed to keep you dry and comfortable. It protects you from

More information

2014 British Columbia Building Code Changes

2014 British Columbia Building Code Changes District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most

More information

WHOLE-HOUSE VENTILATION SYSTEMS

WHOLE-HOUSE VENTILATION SYSTEMS Technology Fact Sheet WHOLE-HOUSE VENTILATION SYSTEMS Improved control of air quality Buildings for the 21st Century Buildings that are more energy efficient, comfortable, and affordable that s the goal

More information

City of Elk River BASEMENT Office Use Only

City of Elk River BASEMENT Office Use Only City of Elk River BASEMENT Office Use Only Fire and Building Safety Division (FABS) Building Permit Application Notes Scan Permit Total Date Permit # PID # $ Site Address Suite/Unit Structure Type Single

More information

Yuba County Building Department Operation and Maintenance Manual

Yuba County Building Department Operation and Maintenance Manual Yuba County Building Department Operation and Maintenance Manual In compliance with the California Green Building Standards Code, this Operation and Maintenance Manual shall be available at Final Inspection

More information

HV AC CODE CHECKLISTS

HV AC CODE CHECKLISTS The following text is informational only and shall serve as an informational guide for HV AC contractors, journeymen, and apprentices working in the Heating, Ventilation, and Air Conditioning industry.

More information

Glossary of HVAC Terms

Glossary of HVAC Terms Glossary of HVAC Terms Heating, Ventilation and Air Conditioning (HVAC) is a major sub- discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other

More information

STANDARD FEATURES & PROCESS- NEW HOME CONSTRUCTION. Now offered for a limited period of time, free solar with each home!

STANDARD FEATURES & PROCESS- NEW HOME CONSTRUCTION. Now offered for a limited period of time, free solar with each home! STANDARD FEATURES & PROCESS- NEW HOME CONSTRUCTION Now offered for a limited period of time, free solar with each home! ENERGY EFFICIENT ITEMS BUILD IN YOUR HOME 50 Gal Energy Star Hot Water Heaters with

More information

WHEN IS A PERMIT REQUIRED?

WHEN IS A PERMIT REQUIRED? WHEN IS A PERMIT REQUIRED? Any owner, builder, contractor, or other authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure,

More information

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers City of Duluth Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers Thank you for taking the time to join us today. We know you are busy and your time is valuable.

More information

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh Accessory Apartment Construction Guide For Single Detached Dwelling and Semi-Detached Dwellings that have been in existence for at least five (5) years Notes: Buildings that are less than five (5) years

More information

GREEN DEVELOPMENT PLAN Developer Name: Project Name: Address (Street/City/State) Description of Process. Goals. Design & Development Team Members Name

GREEN DEVELOPMENT PLAN Developer Name: Project Name: Address (Street/City/State) Description of Process. Goals. Design & Development Team Members Name GREEN DEVELOPMENT PLAN Developer Name: Project Name: Address (Street/City/State) Description of Process A description of the process that was used to select the green building strategies, systems and materials

More information

Guide to the (Non-Residential) California Green Building Standards Code. Including changes effective July 1, 2012

Guide to the (Non-Residential) California Green Building Standards Code. Including changes effective July 1, 2012 Guide to the (Non-Residential) California Green Building Standards Code An educational publication by the California Building Standards Commission Third Edition January 2012 CALGreen Section: 5.710.6.2

More information

Chapter 8. Duct Design and Sealing

Chapter 8. Duct Design and Sealing Chapter 8 Duct Design and Sealing Duct Materials The three most common types of duct material used in home construction are metal, rigid fiberglass duct board, and flex-duct. Both metal and fiberglass

More information

How To Make A House Safe

How To Make A House Safe 1 RESIDENTIAL Screen Enclosures Orange County Residential Code Compliance Alternative design method for screen enclosures R301.2.1.1.3 PLAN REVIEW Engineered plans must state that the Alternative Design

More information

Sustainable Strategies for Rehabilitation Projects: 9th Street Office Building Adaptive Reuse Case Study

Sustainable Strategies for Rehabilitation Projects: 9th Street Office Building Adaptive Reuse Case Study Sustainable Strategies for Rehabilitation Projects: 9th Street Office Building Adaptive Reuse Case Study Robert C. Burns, AIA, LEED AP Principal Director of Historic Architecture 804. 648. 5040, ext. 1107

More information

ANSI/BPI-1200-S-2015:

ANSI/BPI-1200-S-2015: Guidelines for Home Energy Professionals Project Standard Work Specifications (SWS) Update to Align SWS with the Combustion Appliance Section of ANSI/BPI-1200-S-2015: Standard Practice for Basic Analysis

More information

NSP3 Rehabilitation Standards Certification

NSP3 Rehabilitation Standards Certification Initial Certification: Subrecipient confirms that it has included in the scope of work all items necessary for the project to meet the NSP1 Rehabilitation Standards upon project completions. Second and

More information

Green and Energy Efficient Homes What you need to know

Green and Energy Efficient Homes What you need to know Green and Energy Efficient Homes What you need to know Introductions Agenda Why green or energy efficiency? What does it mean for a home to be green or energy efficient? Energy Efficient Construction Techniques

More information

energy-saving checklist a guide for rental property owners

energy-saving checklist a guide for rental property owners energy-saving checklist a guide for rental property owners taking responsibility As an individual, your efficient use of energy brings benefits such as lower bills, improved comfort levels in your home

More information

LOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS

LOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS SUBCHAPTER 9 LOW-RISE RESIDENTIAL BUILDINGS ADDITIONS AND ALTERATIONS IN EXISTING LOW-RISE RESIDENTIAL BUILDINGS SECTION 150.2 ENERGY EFFICIENCY STANDARDS FOR ADDITIONS AND ALTERATIONS IN EXISTING BUILDINGS

More information

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842 Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa. 18966 Phone: 215-322-9700 Fax: 215-322-5842 APPLICATION for ZONING and BUILDING PERMIT APPLICATION INSTRUCTIONS:

More information

Chapter Seven RESNET Standards

Chapter Seven RESNET Standards Chapter Seven RESNET Standards 700 RESNET NATIONAL STANDARD FOR HOME ENERGY AUDITS 701 GENERAL PROVISIONS 701.1 Purpose The provisions of this Standard are intended to define a framework for a home energy

More information

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist #506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist Case #: Date: Project Name: Site Address: Application Submittal Building permit applications and plans can be submitted to the

More information

Home Performance with ENERGY STAR. Evaluation Report

Home Performance with ENERGY STAR. Evaluation Report Home Performance with ENERGY STAR Customer Information Evaluation Report Customer Name: Sample Report 2 Address of Building: 123 Johnson Street Mailing Address: Same City: Madison State: WI Zip: 53704

More information

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: Somewhere, FL CLIENT: GAIA GC ID No: 2015000 DATE: 12/31/2015 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792 FLORIDA

More information

Beyond Code Programs: Design Strategies and Best Practices. Eric Makela, Britt/Makela Group

Beyond Code Programs: Design Strategies and Best Practices. Eric Makela, Britt/Makela Group Beyond Code Programs: Design Strategies and Best Practices Eric Makela, Britt/Makela Group Keys to an Effective Beyond Code Program Stakeholders involvement in the decision making process, Established

More information

Green Building of Senior Housing - Nuts and Bolts - Community Housing Partners

Green Building of Senior Housing - Nuts and Bolts - Community Housing Partners Green Building of Senior Housing - Nuts and Bolts - Community Housing Partners Angelwood II King George, VA EarthCraft certified Durable building materials and finishes Pedestrian-friendly site plan with

More information

Minnesota Overlay and Guide to the 2011 Enterprise Green Communities Criteria

Minnesota Overlay and Guide to the 2011 Enterprise Green Communities Criteria Minnesota Overlay and Guide to the 2011 Enterprise Green Communities Criteria April 2012 This document was last revised on 11 17 12 As a result of Enterprise changing their process and document submission

More information

CHARLOTTE COUNTY Community Development Department

CHARLOTTE COUNTY Community Development Department CHARLOTTE COUNTY Community Development Department Building Construction Services Division 18400 Murdock Circle, Port Charlotte FL 33948 Phone: 941.743.1201 Fax: 941.764.4907 www.charlottecountyfl.gov 50

More information

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE: STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE: 61-30.801 Standards of Practice, General. (1) Home inspections performed to these Standards of Practice are intended to provide the client with information

More information

City of St. Charles Basement Finish or Remodel

City of St. Charles Basement Finish or Remodel City of St. Charles Basement Finish or Remodel Building & Code Enforcement Division 2 East Main Street St. Charles IL 60174 630.377.4406 (Office) 630.443.4638 (Fax) http://www.stcharlesil.gov Please direct

More information

Before You Start an Energy Efficiency Retrofit The Building Envelope

Before You Start an Energy Efficiency Retrofit The Building Envelope ABOUT YOUR HOUSE Before You Start an Energy Efficiency Retrofit The Building Envelope The building envelope is the outer layer of the building that separates the indoor living space from the outdoor environment,

More information

2013 BUILDING ENERGY EFFICIENCY STANDARDS

2013 BUILDING ENERGY EFFICIENCY STANDARDS 2013 BUILDING ENERGY EFFICIENCY STANDARDS Title 24, Part 6, and Associated Administrative Regulations in Part 1 CALIFORNIA ENERGY COMMISSION Edmund G. Brown Jr., Governor MAY 2012 CEC 400 2012 004 CMF

More information

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012 2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,

More information

2. What building projects are exempted? (permit not required)

2. What building projects are exempted? (permit not required) BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and

More information

Building and Grounds Maintenance Checklist

Building and Grounds Maintenance Checklist Building and Grounds Maintenance Checklist Name: School: Room or Area: Date Completed: Signature: Instructions 1. Read the IAQ Backgrounder and the Background Information for this checklist. 2. Keep the

More information

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES ADDRESS: 123 MAIN ST MIAMI, FL CLIENT: BUYER ID No: 2014193 DATE: 5/13/2014 INSPECTION OR ASSESSMENT BY: GAIA CONSTRUCTION INC. CGC 1516136 FLORIDA HI-2792

More information

IEQ Management Plan. Denver Museum of Nature and Science ECF Addition

IEQ Management Plan. Denver Museum of Nature and Science ECF Addition IEQ Management Plan GH Phipps Construction Companies 5995 Greenwood Plaza Blvd., Suite 100 Greenwood Village, Colorado 80111-4710 303.571.5377 PHONE www.ghphipps.com Denver Museum of Nature and Science

More information

101 Low-Cost /No-Cost. Home Energy-Saving Measures

101 Low-Cost /No-Cost. Home Energy-Saving Measures 101 Low-Cost /No-Cost Home Energy-Saving Measures Your Touchstone Energy Cooperative has compiled this list of low-cost / no-cost energy-saving measures to help you better manage your home s energy costs.

More information

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression

More information

COMPLETING THE GREEN APPRAISAL ADDENDUM FOR AN NGBS GREEN CERTIFIED HOME

COMPLETING THE GREEN APPRAISAL ADDENDUM FOR AN NGBS GREEN CERTIFIED HOME COMPLETING THE GREEN APPRAISAL ADDENDUM FOR AN NGBS GREEN CERTIFIED HOME Tips Start completing the Addendum early, especially if appraisal will happen before final certification is issued. Complete with

More information

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION REPORT (850) 297-1998 1716 Monticello Dr Tallahassee, Florida 32303 PROPERTY INSPECTION REPORT THIS INSPECTION IS A DETAILED LISTING OF AREAS VISUALLY INSPECTED AT:, Tallahassee FL Client Tallahassee, FL 32304

More information

Residential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer

Residential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer Residential HVAC Load Sizing Training October 14, 2015 David Kaiser Green Code Plan Reviewer DCRA - Green Building Division Regulations of green codes including: Green Building Act Green Construction Code

More information

Air Conditioning Contractors of America

Air Conditioning Contractors of America Air Conditioning Contractors of America WHO IS ACCA???? Industry Manuals Residential D, J, S, H, RS, T, P A manual J load calculation is a measurement of how much heating and cooling capacity a home will

More information

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations

More information

Does Wall Township require an inspection by the building department on resale of a home?

Does Wall Township require an inspection by the building department on resale of a home? Selling your home Does Wall Township require an inspection by the building department on resale of a home? No. We do not require a Certificate of Continued Occupancy on the resale of home. A Smoke Detector,

More information

New Homes EPS Modeling Frequently Asked Questions. Developed by Energy Trust of Oregon

New Homes EPS Modeling Frequently Asked Questions. Developed by Energy Trust of Oregon New Homes EPS Modeling Frequently Asked Questions Developed by Energy Trust of Oregon 1 General Questions 3 REM/Rate questions 4 -Creating custom entries 4 -Modeling Heat Pumps 5 -Modeling HRV/ERV 7 -Modeling

More information

APPENDIX C FORMS 2010 FLORIDA BUILDING CODE ENERGY CONSERVATION C.1

APPENDIX C FORMS 2010 FLORIDA BUILDING CODE ENERGY CONSERVATION C.1 APPENDIX C FORMS 2010 FLORIDA BUILDING CODE ENERGY CONSERVATION C.1 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = The lower the Energy Performance Index, the more efficient

More information

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES Department of Health and Human Services, Division of Public Health Occupational and Environmental Epidemiology Branch 1912 Mail Service Center, Raleigh, North Carolina 27699-1912 BUILDING ASSESSMENT QUESTIONNAIRE

More information

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling October 2014 contents General Information

More information

Building Energy Codes 101 October 23, 2013. Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance

Building Energy Codes 101 October 23, 2013. Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance Building Energy Codes 101 October 23, 2013 Matthew Giudice Building Policy Associate Midwest Energy Efficiency Alliance OVERVIEW 1. Introduction 2. Energy Code Development 3. Adoption Process 4. Elements

More information

EarthCents (DSM) Program Summary

EarthCents (DSM) Program Summary EarthCents (DSM) Program Summary Renewable Energy EarthCents Programs Solar Water Heating This program is available to residential customers for the installation of a qualifying solar thermal water heater.

More information

Housing Quality Standards Inspection Checklist

Housing Quality Standards Inspection Checklist Housing Quality Standards Inspection Checklist To prevent delays, the R.T.A. must be complete and upon submission the unit must be in move in condition or an inspection will not be conducted. A Fair Housing

More information

RRIO Checklist. Use of checklist: Definitions: Limitations

RRIO Checklist. Use of checklist: Definitions: Limitations CITY OF SEATTLE RENTAL REGISTRATION AND INSPECTION ORDINANCE (RRIO) RRIO Checklist Use of checklist: Property owners will use the RRIO Checklist to confirm that their rental housing properties and units

More information

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL 60458 Phone: (708) 458-2130 Fax: (708) 458-3207 SELF EVALUATION CHECKLIST FOR RESIDENTIAL AND MULTI-FAMILY DWELLING INSPECTIONS The attached checklist

More information

Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot

Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot Craig Selover Selover Consulting craig@dotmc.us H:248 542-3010 C:248 917-1380 Floor Plan Floor Plan All Piping WaterSense,HERS,

More information

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects Makeup Air For Exhaust Systems In Tight Houses Tony Jellen Engineering Projects PA Housing & Land Development Conference February 23, 2012 Effects of Kitchen Ventilation on Residential Dwellings Anthony

More information

CLOSED CRAWLSPACES. Have you ever been in your crawlspace? If not, have you ever even

CLOSED CRAWLSPACES. Have you ever been in your crawlspace? If not, have you ever even CLOSED CRAWLSPACES What s In the Crawlspace? Wet Sagging Fiberglass Improper Drainage Have you ever been in your crawlspace? If not, have you ever even opened the door to look inside and see what it looked

More information

ENERGY EFFICIENCY PLAN REVIEW CHECKLIST

ENERGY EFFICIENCY PLAN REVIEW CHECKLIST GEORGE CHAVEZ, City Building Official DAVID YELTON, Building Inspection Manager NESTOR OTAZU, Community Preservation Manager BUILDING & SAFETY DIVISION 455 North Rexford Drive, 1 st Floor Beverly Hills,

More information

Air Conditioning Systems DOE, DOE ARRA, LIHEAP WX, RMP. Heating Systems DOE, DOE ARRA, LIHEAP WX, LIHEAP Crisis, Questar

Air Conditioning Systems DOE, DOE ARRA, LIHEAP WX, RMP. Heating Systems DOE, DOE ARRA, LIHEAP WX, LIHEAP Crisis, Questar Air Conditioning Systems DOE, DOE ARRA, LIHEAP WX, RMP Air conditioning system replacement or repair is an approved Weatherization Measure for our climate when auditing with a SIR of 1 or higher. It is

More information

HOMEOWNER S PERMIT GUIDE

HOMEOWNER S PERMIT GUIDE HOMEOWNER S PERMIT GUIDE WHEN IS A PERMIT REQUIRED? Department of Development and Permits 306 Cedar Road, City Hall 2 nd Floor P.O. Box 15225 Chesapeake, VA 23328 Phone: (757) 382-6018 Fax: (757) 382-8448

More information