Operating Instructions. UL325 Compliant Non-monitored



Similar documents
Operating Instructions

Operating Instructions

Operating Instructions

INSTALLATION INSTRUCTIONS

Water Leak Detection System

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

HM-W536 Install Guide

Shunt lock function 3066

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

INSTALLATION & SERVICE MANUAL. Display Panel

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Solid State Timers Type F

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Self Monitoring Power Supply (BPSM)

How To Use A Ds340 (Dsp)

ACS-30-EU-EMDR-10-MOD

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

TC-9102 Series Surface Mount Temperature Controllers

Advantium 2 Plus Alarm

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Model 1756 Test Lead Kit

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

FSLIMRF

LIEBERT VNSA Installation Sheet

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Mobile Data Power Model: MDP-25

CITY OF LOS ANGELES CALIFORNIA

RAY-MAX Integrated Solar Power Strip

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

MCR1900 Media Converter 19-Slot Chassis

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Universal Voltage Terminal Photoelectric E3JM

FIRERAY 2000 Installation Guide

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

HORNET Remote Control Systems

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

PART 1 - INTRODUCTION...

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

PRODUCT PROFILE FEATURES

OUTPUT CABLE CONNECTIONS:

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

Capacitive Prox E2K-X

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Streaming Potential System (SPT1000, SPD1000)

User's Guide. True RMS Industrial Multimeter

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

WD-AMX Water Detection Controllers

BACnet Automation Interface Module (Network Version)

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

ETZGAR CONVEYOR COMPANY Controls Section v12.05

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Digi-Motor Installation Guide

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

MANAGEMENT SOLUTION (P.A.M.S.)

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

T1 Backhaul Connectivity Solution All Products :: Application Note

! WARNING. Before using product, read and understand instructions.

SECTION LOW VOLTAGE LIGHTING CONTROLS


FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

TrueAlarm Fire Alarm Systems

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Comfort Control Relay Panel (CCRP)

User Manual for CH-PFC76810

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

ST Series POWER SUPPLIES USER INSTRUCTIONS

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

Radiant Temperature Sensor TY7321

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Cross-beam scanning system to detect slim objects. 100 mm in

Safety Relays ESM/ESM-F

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Original instructions Tina 3A/Aps Adaptor unit

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Color Mark Sensor with Red or Green LED E3S-VS

AutoRanging Digital MultiMeter

Installation and Operation Guide for PD4100 Series Power Control Centers

Modular I/O System Analog and Digital Interface Modules

Transcription:

IRB-325 Infrared Photocell UL325 Compliant Non-monitored Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product to. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death!

Product Overview The IRB-325 conforms to the UL325 standard when used with the powder coated steel hoods. Registration reference number 9901994. The IRB-325 photocell is used as an external entrapment protection device type B1 non-contact sensor for use with automatic gate and door openers. The IRB-325 transmitter and receiver have a line of site range of up to 65 feet. The IRB-325 operates on 12 VDC to 24 VAC and draw 150 ma maximum. The IRB-325 receiver is activated whenever anything interrupts the beam from the transmitter, triggering the relay output to change state and send a signal to the operator that there has been an interruption. WARNING: This product is UL 325 compliant with a non-monitored output. IRB-325 Instructions 2

Technical Specifications Power Supply 12 Volts Dc to 24Volts AC Power Supply Tolerance +/- 20% Current Draw 150 ma maximum Housing Material UL and CSA Type 4, 4X, 3, 3R, 12, 13 rating and powder coat steel hood Relay Type Type C Rating 1A @ 30 VDC Temperature Range -40 o F to 170 o F Connector Screw terminal isolated contact (2) transmitter (5) receiver Power Indicator Green LED Detect Indicator Red LED Dimensions H=5.03 in, W=3.06 in, D=3.02 in Range 6 feet to 65 feet line of sight Power Controls, Indicators and Connections Transmitter Receiver LED Power LED Green SMT glows when power is applied Green SMT glows when power is applied Connections Screw terminal Connections Screw terminal 2 position for power source 5 position for power and controls Detect LED (2) Red SMT LEDs glow on detection The IRB-325 is an external entrapment device Type B1 non-contact sensor for use with automatic gate operators. If the IRB-325 is used as the primary entrapment protection device it must be monitored for presence and fault condition. The IRB- 325 does not produce a monitored output. IRB-325 Instructions 3

Installation 1. Disconnect the IRB-325 from power before installing or servicing the device. 2. Always follow the instructions of the gate operator manufacturer regarding installation of type B1 sensors on the gate operator. The instructions of the gate operator manufacturer always supersede any instructions given in this or any other instructions by EMX Industries Inc. 3. The IRB-325 has to be powered by 12V 24V AC/DC 150mA power supply. 4. Do not connect the IRB-325 output to loads higher than 1A @ 30V AC/DC. 5. Connect power to terminals 1 and 2 on IRB-325 transmitter marked TX polarity is not important. 6. Connect power to terminals 4 and 5 marked power input on the IRB-325 receiver, marked RX polarity is not important. 7. For operators that require normally closed contact for entrapment protection, connect terminals 1 (NC) and 2 (COM) to the designated terminals in the gate operator. 8. For operators that require normally open contact for entrapment protection, connect terminals 2 (COM) and 3 (NO) to the designated terminals in the gate operator. 9. Install the IRB-325 according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate. 10. The IRB-325 is housed in a NEMA 4X enclosure. To insure the integrity of the enclosure make sure the covers are attached and closed tight with the help of four plastic screws provided. The wiring to the IRB-325 Enclosure has to enter via watertight strain relief or watertight conduit connector. 11. The IRB-325 must be powered by Class 2 circuits only, wiring must be segregated from other circuits or insulation must be provided that is suitable for the highest voltage for those circuits. HIGH MED LOW 1 2 3 4 5 N/C COM N/O PWRPWR IRB-325 RX IRB-325 Instructions 4

Operational settings WARNING: To reduce the risk of sever injury or death 1. Read and follow all operation instructions. 2. Always follow gate operator manufacturer installation instructions regarding installation of Type B1 sensor to the operator. 3. Disable the gate so it is unable to move. 4. With the IRB-325 mounted in place and powered, make sure the transmitter TX is in line of sight of the receiver RX. 5. Introduce an obstruction in form of a hand between the IRB-325 transmitter and receiver. Two Red LED s on the receiver have to turn on. Check the operator control board that the safety input is actuated. 6. Remove the obstruction and the Red LED s in receiver will turn off. 7. Should the IRB-325 fail to recognize the obstruction lower the sensitivity by moving jumpers J1 and J2 to a lower position. 8. Should the two Red LED s be turned on while there is no obstruction increase the sensitivity by moving jumpers J1 and J2 to a higher position. IRB-325 Instructions 5

TROUBLE SHOOTING GUIDE Symptom Possible cause Solution Does not detect interruption Sensitivity too high Signal is reflecting off another surface Move jumpers J1 and J2 to a lower position Check area for highly reflective surfaces Red detect LED stays on Sensitivity too low Transmitter does not have power Receiver does not see transmitter Move jumpers J1 and J2 to a higher position Check power source for transmitter Make sure transmitter and receiver have line of sight alignment Receiver activates but does not transmit signal to operator Faulty connection between receiver and operator control input Check wires and terminal connections to make sure they are good IRB-325 Instructions 6

Ordering Information IRB-325 Infrared photocell includes transmitter and receiver Accessories IRB-325-HD IRB-325-PT IRB-325-SP Set of 2 powder coated steel protective hoods required for UL-325 Mounting post 2 in x 2 in x 2 ft black powder coat Watertight strain relief for use with interconnection cords. IRB-325-SP IRB-325-PT IRB-325 Instructions 7

4564 Johnston Parkway Cleveland, Ohio 44128 United States of America www.emxinc.com Technical Support: (216) 834-0761 technical@emxinc.com Sales: (216) 518-9888 Fax: (216) 518-9884 salessupport@emxinc.com IRB-325 Instructions 8