Using meters to measure steam flow



Similar documents
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

ABB Flowmeters Review of industrial processing flowmeters

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

Custody Transfer Measurement. with the V-Cone Flowmeter

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Flow Measurement Options for Pipeline and Open Channel Flow

A basic introduction to steam

Energy and Flow Measurement for Hydronic Systems

Energy Systems Engineering Technology

Flow Measurement in Pipes and Ducts. Flow Measurement in Pipes and Ducts, Course #503. Presented by:

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

Thermal Dispersion Mass Flow

FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS. Sami Halilah Dynamic Flow Computers Houston, Texas

The Unique Accelabar Flow Meter

Flue gas measurement and control Partial-insertion pitot tubes in CEMS applications

Take total control of your HVAC system with cost-saving flow and thermal energy meters

Daniel Venturi Tubes and Flow Nozzles Brochure

Fluid Flow Instrumentation

V-Cone, An Alternative to Orifice Meter in Wet Gas Applications

For Multi-Parameter Meters see mvx

Heating Water by Direct Steam Injection

Testing methods applicable to refrigeration components and systems

Oil and Gas Custody Transfer

Flow Sensors. - mass flow rate - volume flow rate - velocity. - stream line parabolic velocity profile - turbulent vortices. Methods of measurement

FLUID FLOW Introduction General Description

Liquid Flowmeters A Guide for Selecting a Flowmeter for Pressurized Systems

Fundamentals of Mass Flow Control

The World Market for Thermal Flowmeters

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

OIL & GAS PRODUCTION AUDITING

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

Design and Analysis of Various Bluff Objects for Vortex flow meters

COMBIMASS. Technical Data COMBIMASS eco-bio +

Rosemount Orifice Plate in Wet Gas

Implementing New Technology at TransCanada Meter Stations -- Better, Faster, Cheaper

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Accurate Air Flow Measurement in Electronics Cooling

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

measurement, but almost any pipe elbow can be calibrated Elbow meters are not as potentially accurate as venturi,

FLOW METER SPECIFICATION AND APPLICATION ANALYSIS Class #41

Industry faces unrelenting pressure to increase production

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Industrial Steam System Process Control Schemes

How does solar air conditioning work?

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

C. starting positive displacement pumps with the discharge valve closed.

Advances in Thermal Dispersion Mass Flow Meter Accuracy

Gas Custody Transfer Calibration

Ultrasonic Meters: A Natural Choice To Measure Gas Flow

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Class A Foam Mixing and Application Equipment

Theory overview of flow measurement using differential pressure devices based on ISO-5167 standard.

Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2

Flow. 1.1 Introduction. 1.2 Units of Flow. 1.3 Measurement of Flow

Steam System Best Practices Condensate System Piping

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class # 2010

Redefining Spray Technology

Service catalog Flow products

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

Fluxi 2000/TZ Turbine Gas Meter

Averaging Pitot Tubes; Fact and Fiction

Liquid level measurement using hydrostatic pressure and buoyancy

Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems

TEXAS COMMISSION ON ENVIRONMENTAL QUALITY WORK ASSIGNMENT 5

How To Use A Flowmeter

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT page 1 THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT INTRODUCTION COEFFICIENT OF DISCHARGE

EDD-600 FLOW TOTALIZER RATE INDICATOR OPERATION MANUAL. P.O. Box Odessa, Texas USA.

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

Flow distribution and turbulent heat transfer in a hexagonal rod bundle experiment

Air Eliminators and Combination Air Eliminators Strainers

VOLU-probe/SS. Stainless Steel Pitot Airflow Traverse Probes. Accurate airflow measurement for demanding applications

FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER

Refrigeration Basics 101. By: Eric Nelson

T U R B I N E G A S M E T E R

SAMPLE CHAPTERS UNESCO EOLSS

Desuperheater Online Program Sizing Guidance

VACUUM REFRIGERATION SYSTEMS

VAD Variable Area Desuperheaters

OPTIMASS 1400 Technical Datasheet

Fiscal Measurement Natural Gas

A Practical Overview of Level Measurement Technologies

ME 538: Experiment # 1 Flow measurement and particle generation instruments

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15

4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re.

Selecting TEMA Type Heat Exchangers

PPB Dissolved Oxygen Measurement - Calibration and Sampling Techniques

OPTIMASS 6000 Technical Datasheet

Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

Transcription:

Page 1 of 6 April 1998 Plant Engineering SELECTING NEW TECHNOLOGY: PROBLEM SOLVING Using meters to measure steam flow Jesse L. Yoder, Ph.D., Senior Analyst, Automation Research Corp., Dedham, MA Key Concepts Types of steam--wet, saturated, and superheated--influence selection of the flow measuring device. As measurement becomes more accurate, the meter's price increases. Installation varies for each type of flowmeter. When people hear about fluid measurement, they usually think of checking either liquid or gas flow. This belief is natural, since about 90% of fluid measurements are for these two applications. In a worldwide survey of flowmeter users, 68% measured liquids, 22% gas, and only 10% steam. While 10% may not seem like a large percentage, it represents a significant number of measurements. Many companies measure steam for purposes of internal custody transfer and for utility applications in power generation and chemical plants. Steam types While all steam may look the same, the way it is measured varies with the type: wet, saturated, or superheated. Wet steam Wet steam is probably the most difficult type to measure. It contains both condensed hot-water particles and steam, and is considered two-phase flow. Wet steam is difficult to measure with any of the technologies currently available, and accuracies can vary. Saturated steam Saturated steam occurs at a particular pressure and

Page 2 of 6 corresponding temperature when a state of equilibrium exists between liquid and vapor states; for example, at the end of the boiling process when only steam is present. Superheated steam Superheated steam is at a higher temperature than the saturation temperature at the same pressure. Thus, it occurs when saturated steam is subjected to an increase in temperature while the pressure remains constant or is decreased while the temperature remains the same. In a boiler, steam is saturated. As steam leaves a boiler, a pressure drop is created by the flow. Reduced pressure, along with a relatively constant temperature, results in superheated steam, which acts as a gas and conforms to general gas laws. Flowmeter types Steam flow is measured with several types of flowmeters: differential pressure-based (orifice plates, flow nozzles, venturi tubes, and averaging pitot tubes), vortex, Coriolis, and ultrasonic. For specific applications contact the manufacturer for recommendations based on steam type, flow rate, and operating conditions. Differential pressure-based flowmeters Differential pressure-based flowmeters measure steam flow by using a primary element to cause a pressure drop. Flow rate varies with the square root of the pressure drop across the primary element. Pressure drop is measured with a differential pressure (DP) transmitter. Orifice plates contain a hole or orifice through which liquid passes. Upstream and downstream piping are required to condition the flow and provide for accurate measurement. Pressure is measured upstream and downstream from the orifice plate with a DP transmitter, which then calculates the flow rate. Flow nozzles (Fig. 1) have a narrow opening for steam to pass through. One of the most common uses of flow nozzles in the power industry is to measure the amount of steam going to a turbine. Fig. 1. Flow nozzles for high-velocity and hightemperature

Page 3 of 6 Pipe.jpg (12636 bytes) jobs are usually manufactured from stainless steel to prevent corrosion of the polished throat. They are used primarily for high-velocity and high-temperature applications, and work best with fluids whose Reynolds numbers are at or above 10,000. Venturi tubes consist of a tapered inlet and outlet with a straight section in the middle that is narrower than the pipe diameter. They have a length of about eight pipe diameters. Pressure drop is lower than with orifice plates. Upstream pipe requirements are less stringent than those for orifice plates or flow nozzles, and they do not require straightening vanes. On the other hand, venturi tubes are more difficult to manufacture with precision than orifice plates or flow nozzles, which makes them more expensive. Their size makes them difficult to inspect and change. Averaging pitot tubes (Fig. 2) consist of an insertion sensor spanning the full pipe diameter that detects an impact and reference pressure through a series of ports on the upstream and downstream faces. By averaging pressure signals, a differential signal is created that resembles the signal produced by an orifice plate meter. Fig. 2. Averaging pitot tubes span the entire pipe diameter, are easy to install, and provide an inexpensive way to measure steam. (Courtesy Rosemount, Inc.) Valve.jpg (13844 bytes) Vortex flowmeters

Page 4 of 6 Vortex flowmeters (Fig. 3) are becoming widely used for steam flow measurement. They operate on a principle known as the von Karman effect. According to this principle, fluid that passes a bluff body generates vortices alternately on either side of the body. Frequency of vortices generated is proportional to the flow rate of the fluid. Wheel.jpg (16104 bytes) Fig. 3. Vortex flowmeters have a barlike or bluff construction that allows for the passage of dirt. (Courtesy Yokogawa Industrial Automation) Although vortex flowmeters cost more than DP-based transmitters and orifice plates, their installed cost is comparable to that of orifice plate flowmeters because of the additional expense of the mounting systems and pressure taps required for orifice plate meters. Vortex meters, like DP-based flowmeters, are also sensitive to inlet flow conditions, and may require straightening vanes or straight pipe runs to obtain required accuracy. Coriolis flowmeters Coriolis flowmeters directly measure mass flow rate. They have one or more bent, straight, or U-shaped vibrating tubes in the fluid stream. As the fluid passes through the tubes, they twist. The amount of tube twisting is directly proportional to mass flow. This meter can also be used for heat measurement of low-pressure, superheated steam. The chief advantage of Coriolis flowmeters is providing highly accurate measurements of mass flow rate without flow conditioning or accessory devices such as pressure or temperature measurement. Ultrasonic flowmeters Ultrasonic flowmeters measure the time it takes an ultrasonic pulse to travel back and forth across a pipe at an angle. When the

Page 5 of 6 pulse travels with the flow, it moves quicker than when it travels against the flow. Difference between these times is proportional to the flow rate. These meters are especially suited for measuring flow in large pipes. As with Coriolis meters, they have a relatively high initial cost. While DP-based flowmeters are thoroughly entrenched as a means to measure steam flow, the newer technologies of vortex, Coriolis, and ultrasonic measurement are used more often. One disadvantage the newer technologies have is that fewer standards have been written for them, which limits their use. Related info Comparing flowmeters -- Edited by Joseph L. Foszcz, Senior Editor, 847-390-2699, j.foszcz@cahners.com Portions of this article were contributed by Tom O'Banion of Micro Morion and John Garnett of Dieterich Standard. More info The author is available to answer questions about devices to measure steam. He can be reached at 781-461-9100. [Top] Comparing flowmeters Type Advantages Disadvantages Orifice plate Flow nozzle Venturi tube Low cost Inexpensive installation No moving parts Moderate price Low pressure drop Simple upstream requirements High pressure loss Low rangeability Flow conditioning Difficult installation Difficult cleaning High cost Limited rangeability Awkward size

Page 6 of 6 Accuracy does not degrade Not suited for low flow Averaging with use rates pitot tube Low pressure drop High cost Vortex Easy to install Sensitivity to vibration Low maintenance and inlet flow Moderate installed cost Good accuracy Coriolis High accuracy High initial cost No flow conditioning Ultrasonic Non-intrusive No pressure drop Works in large pipe diameters High initial cost [Top] Plant Engineering - Apr 01, 1998 register help contact us magazines subscribe ad info Copyright 2000 Cahners Business Information, A Division of Reed Elsevier, Inc. Read our Use Agreement and Privacy Statement.