Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index



Similar documents
Cable-Gard Static Discharge Reels

2900 & 3000 Series Commercial Duty Reels 4000 Series Industrial Duty Reels Series Industrial Duty Reels 8000 Series Hazardous Location

air water oil antifreeze grease diesel fuel kerosene oxygen-acetylene lpg-methane electricity Hose & cable reel

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Extension Cord Safety Policy

Plugs and Receptacles

8146/5 Series Breaker Panelboards

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

For Models #6-5001, #6-7501, # & #10-12K1

Title: Grounding and Bonding Rev-01

DISPLAY & EXH I B I T

Operating Instructions

Medical Lighting. XL4 Patient Light

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Electrical Grounding. Appendix C

Operating Instructions

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

USA: 866.LAWSON4U ( ) Canada: lawsonproducts.com. Electrical Industrial and Fleet Solutions

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

AMERBRITE UNDERWATER WHITE LED POOL LAMP

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Fire Alarm System Plans Review Checklist Property location Date of Review

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Instructions & Safety Information Models A220-20D and A220-20L Version 2

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

GENERAL ELECTRICAL REQUIREMENTS

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Generator DoCKInG StatIonS

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

PUSHBUTTON/TEST INSTRUMENTS

IEC 309 INTERLOCKS NORTH AMERICAN

SP H/M/L AFLR /1464/ /1469/ /22/ AFLR /8 1468/1209/ /6050/ /31/28 115

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Top Commercial / Residential Electrical Requirements *

Carlon Carflex Liquidtight Flexible Tubing

Evaluating Water-Damaged Electrical Equipment

ELECTRICAL INSPECTION BULLETIN (Effective )

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

Submitted to Reference Approval Construction Unit Designation Schedule #

Lighting. Midmark Animal Health Products

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

RAY-MAX Integrated Solar Power Strip

Evaluating Water-Damaged Electrical Equipment

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

IMPORTANT SAFETY RULES TO FOLLOW

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Electrical Practices for Construction Work

12-Volt 10-Amp Regulated Power Supply

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

Instruction / Installation Sheet DataComm Electronics WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

Explosion-Proof Electric Unit Heaters

INSPECTION GUDELINES

October Safety Subject

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

LHD LINEAR HEAT D ETECTIONN

AlarmLine Addressable Linear Heat Detector

HIGHLAND VALLEY SUPPLY, INC STANDARD TERMS AND CONDITONS OF SALE

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

USER S MANUAL HSC-24A

In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius).

LED Sign Module. LED Super Tiny Strip. LED Accessories. LED Power Supply

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

HP Managed and Unmanaged Notebook Charging Carts Overview. Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

Advantium 2 Plus Alarm

Cable/Conduit Conversion

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

ELECTRICAL SAFETY Information Bulletin

NEC 2014 Code Changes

SMD Rework Station TABLE OF CONTENTS

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Utility Distribution Systems

Owner's/Installation Manual

Transcription:

Section R Index Product Page Number and R-2 3 Weatherproof Cable and Static Discharge Reels R-4 R-5 R-6 Index www.hubbell-wiring.com

and and Hubbell Electric Cord and Cable Reels Hubbell Wiring Device Kellems offers a complete line of electric cord, cable and static discharge reels for commercial, industrial and weatherproof applications. Hubbell reels eliminate unmanaged cords and cables which cause trip hazards or electric shock due to damaged wire insulation. These reels provide safe and effective wire management for your facility or plant floor. For Safety, Durability and Performance look to the industry Leader look to Hubbell. Weatherproof Cable Reels are made for the most abusive and demanding environments. These reels feature a solid steel construction, a 600V rating with SOW - A type cable and Type 4X enclosure rating. They are designed for use with 15 & 20 amp industrial products such as portable outlet boxes, Insulgrip and Twist- Lock devices and pendant push-button stations. are built to provide safe, convenient power and lighting for demanding industrial applications and environments. The industrial reels are all steel construction, have a 300V rating with SJ cord and can be ceiling, wall or bench mounted. They are available with fluorescent or incandescent hand lamps as well as a HBL5269C connector body or portable outlet box versions. are designed for the less demanding requirements of commercial and light industrial environments. The commercial reels feature steel construction and have a 125V rating with type cord. These reels are UL Listed and provide power and lighting for all your needs. Static Discharge Reels ground portable equipment operating in hazardous environments. When properly clamped to ground, the static discharge reel will prevent the build up of static electricity and reduce the chance of sparking which could cause an explosion. Hubbell has developed a broad product line of cord reels to offer safe and efficient wire management solutions for all applications. Whatever your requirements, Hubbell has the reel safety story. R-2 www.hubbell-wiring.com

and Weatherproof Cable Reels Solid steel construction. UL Type 4X enclosure rating. Polyester baked on powder coat finish. Ratchet lock. Multi-position roller guide. Pivot base. Superior design for the most demanding environments. Watertight enclosure protects spring motor, junction box, slip ring assembly and cable entrance from hosedown and corrosion. Baked on finish provides tightly bonded shield to protect reel from abrasion or corrosion. Can be disengaged in field for constant tension applications, built in product flexibility. Adjustable guide with nylon rollers may be mounted in four different positions. Allows 340 deg. rotation of Increases range of cable to nearly any direction. Steel construction with yellow powder coat finish. Durable design and corrosion resistant. Multi-position guide arm. Mounting on the ceiling, wall, floor or bench. Multi-directional nylon rollers on guide arm. Easier pull and prolonged cord life. 12 AWG 3 cond. cord standard on power reels. Greater current carrying capacity. Positive-latch mechanism. Automatically maintains desired cord length. Plug-in power cord. Requires no electrical wiring. Steel construction. Automatic shut off switch. Molded on plug for power cord. Compact size/flexible mounting. Automatic ratchet lock. Static Discharge Reels Steel construction. Compact design. Massive grounding jaw clamp. Durable design for commercial and general purpose applications. Available on fluorescent & incandescent versions. The automatic switch turns off power to the electrical attachment when the cord is fully retracted. Requires no electrical wiring. Takes up little room and can be ceiling, wall or bench mounted. Holds cord at desired length and provides easy, smooth retraction of cord. High quality durable design. Takes up little space. Provides secure low resistance ground termination. Note: Static Discharge Reels provide an approved method of complying with OSHA regulation 29 CFR 1910.107(E)(9). and www.hubbell-wiring.com R-3

Weatherproof & Static Discharge Reels Weatherproof and Static Discharge Reels HBL501431W HBL50SD HBL14PB Weatherproof Cable & Static Discharge Reels Catalog Cable Volts Cable Amps Weight Description Numbers Feet Meters Type lbs. kg 14 weatherproof HBL501431W 50 15.2 600 14/3 SOW-A 15 55 24 16 weatherproof HBL501232W 50 15.2 600 12/3 SOW-A 20 80 36.3 16 weatherproof HBL501242W 50 15.2 600 12/4 SOW-A 16 86 38.7 16 weatherproof HBL501032W 50 15.2 600 10/3 SOW-A 25 86 38.7 16 weatherproof HBL501042W 50 15.2 600 10/4 SOW-A 20 92 41.1 Static discharge HBL50SD 50 15.2 Single 3/32 12 5.4 Steel Static discharge HBL50YSD 50 15.2 Dual (Y) 3/32 13 5.9 Steel 14 pivot base. HBL14PB 5 2.27 16 pivot base. HBL16PB 13 5.9 Notes: All weatherproof cable reels are supplied with wire leads. 35ft./10.6m + Dual 15ft./4.5m for Y. Power supply cable not supplied. Specifications Weatherproof Reel In (mm) A B C D E F G H I J 14 reel 6.50 8.12 16.25 13.75 3.00 12.19 3.00 3.00 3.00 6.50 (165) (206) (413) (349) (76) (310) (76) (76) (76) (165) 16 reel 6.50 9.12 18.25 15.75 3.00 14.19 6.00 6.00 4.94 6.50 (165) (232) (464) (390) (76) (360) (152) (152) (125.5) (165) 8.81 (224) A D Static Discharge Reel 7.88 (200) B Line Entrance 3/4" NPT C 8.62 (219) 3.35 (85) F 1.50 (38) E Weatherproof Cable Reels Listings/ UL 355 and CSA Certifications C22.2 No. 21. Type 4X enclosure CAN/CSA - C22.2 No. 21. Operation Dry indoor & wet and damp outdoor non-hazardous location. Classification Agriculture, automotive, commercial and industrial applications. 340 Pivot Base (Optional) G I H Pivot base for use only with Weatherproof Cable Reel. J Mounting Surface 4 Holes 14" 0.44(11) dia. 16" 0.53 (13) dia. Reel Base 4 Holes 14" 0.47 (12) dia. 16" 0.53 (13) dia. R-4 www.hubbell-wiring.com

HBL45123C HBL45123R HBL50163IN HBL50162FL Catalog Cable Volts Cable Amps Weight Watts Description Numbers Feet Meters Type lbs. kg (Max) Reel with HBL45123C 45 13.7 125 12/3 15 23 10.4 1875 HBL5269C SJEO connector. Reel with HBL45123R 45 13.7 125 12/3 15 23 10.4 1875 portable SJEO outlet box. Reel with HBL50163IN 50 15.2 125 16/3 0.8 21 9.5 100 incandescent hand lamp. Reel with HBL50162FL 50 15.2 120V 16/2 0.3 21 9.5 13 fluorescent AC hand lamp. Pivot Base HBL340PB - - - - - 5 2.26 - Note: Supplied with 5 ft. power supply cord with HBL5266C, 15A straight blade plug. Specifications In (mm) A B C D E F 13.00 12.38 8.00 2.50 9.70 1.25 (330) (321) (203) (64) (246.4) (32) B HBL340PB A C E D F Listings/ UL 355/CSA C22.2 Certifications No. 21. Operation Dry, indoor, nonhazardous locations. Classification Incandescent Fluorescent Commercial/Industrial. 100 watt max., switch, no receptacle. 13 watt only. Wall mount Ceiling mount Bench mount www.hubbell-wiring.com R-5

Wiring Device-Kellems HBLC25163FL HBLC25143IN HBLC25163C Description Catalog Cable Volts Cable Amps Weight Watts Numbers Feet Meters Type lbs. kg (Max) Reel with fluorescent HBLC25163FL 25 7.62 120V 16/3 10 9 4.1 1200 hand lamp & inline AC receptacle. Reel with fluorescent HBLC25162AFL 25 7.62 120V 16/2 0.3 8.2 3.7 13 hand lamp & automatic AC shut off switch. Reel with non-metallic HBLC25163AIN 25 7.62 125 16/3 0.6 9 4.1 75 incandescent hand lamp & automatic shut off switch. Reel with metallic HBLC25143IN 25 7.62 125 14/3 13 9.5 4.3 1625 incandescent hand lamp with receptacle & circuit breaker. Reel with wire leads. HBLC25163 25 7.62 125 16/3 10 8.5 3.9 1250 Reel with a Hubbell HBLC25163C 25 7.62 125 16/3 10 8.5 3.9 1250 HBL5969VBLKconnector. Note: Reels supplied with 2 ft. power supply cord and molded on straight blade 15A plug. Specifications 2.83" (72) 9.50" (241) 11.38" (289) 4.11" (104) Listings/ UL 355. Certifications Operation Dry, indoor, nonhazardous locations. Classification Incandescent Fluorescent Commercial/Industrial. 75 watt max., auto switch, no receptacle; 100 watt max.bulb, with receptacle. 10A/1200W max with in-line receptacle; 13 watt without receptacle. R-6 www.hubbell-wiring.com