9448 Installation and User Guide



Similar documents
9452/9453 Installation and User Guide

500r+ Installation and User Guide

TS510 & TS500. Installation & User Guide. Compatible Equipment

ACTIVE 5 ENGINEERING MANUAL

How To Set A Timer On A Gg System

Using your LED Plus keypad

HARDWIRED CONTROL PANELS

CONTENTS 4. HOW TO UNSET THE PANEL...7

SECURIT 800L+ CONTROL PANEL

XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

Intruder alarm system Operating Instructions

Intruder alarm system Engineering Information

Accenta/Optima. Engineer s Manual. Honeywell Security. 8SP399A - Accenta mini panel with remote LCD keypad and communicator outputs.

INSTALLATION MANUAL CONTENTS

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

User Guide Veritas 8/Veritas 8Compact/Veritas R8 INS036-5

Intruder alarm system Engineering Information

ACP10 10 Zone Intruder Alarm System

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

TS590. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT 0 ESC

Security System Installation and Programming Guide

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panels. Issue 12

Security System User Guide

INSTALLATION AND PROGRAMMING GUIDE HARDWIRED CONTROL PANEL

UNSET TAMPER FINAL EXIT

AC-115 Compact Networked Single Door Controller. Installation and User Manual

FIREDEX Conventional Fire Panels

IMPORTANT USER INFORMATION

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

User s Information Guide R1A

GST301. (Single Protection Zone) Operation Manual

SECTION DETECTION AND ALARM

SECURIT 800L+ CONTROL PANEL

Programming & Installation PIEZO WARNING. EN : 2009 EN : 2008 EN : 2005 Security Grade 2 Environmental Class II RINS1347-2

9x5x PROGRAMMING GUIDE

NESS D Zone Control Panel and Dialler OWNER S MANUAL

EURO User Manual. Castle Care-Tech 2012 (RINS1531) Issue 2. Page 1

Master User Guide Premier Elite 24/48/88/168/640

USER GUIDE HARDWIRED CONTROL UNIT

SD2. Speech Dialler. Installation and Operator s Manual

User.QXD 09/05/00 14:47 Page 1 Gardtec /582 User Instructions

INSTALLATION MANUAL PC2525. Version 1.1

Speech Dialler Engineering Information

Master User Guide Premier Elite Series

WD-AMX Water Detection Controllers

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

IDS X-Series User Manual D Issued July 2012

Digital Keypad Use s Manual

CA60 Plus Software Version 3.1 User Manual May 2000

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

i 70 Installation Manual V1.04 Contents Grade 2 Wireless Intruder Alarm System YOUR SECURITY IS OUR PRIORITY Installation Instructions 2

LW A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

Control/Communicator Installation Manual

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

PA4. 4 Zone Wired Intruder Alarm System. Installation & Operating Manual. MAINS CLEAR 24Hr. Zone 1 Zone 2 Zone 3 Zone 4

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

Users Guide to Keypad Functions

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

Speech Dialler Engineering Information

TABLE OF CONTENTS FEATURES

How To Control A Car Alarm On A Car With A Remote Control System

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

Solution-16 Operators Manual ISSUE 1.60

Secure Keypads for access control

PX Control Panel. User Manual. Issue C

Quick Installation Guide LCD GSM ALARM SYSTEM LH

Automatic Telephone Dialer TD-101(W)

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

MATRIX 6/816. Control Panel with Remote Keypads Software Version 1.34 USER MANUAL RINS545-7

Security System. User Guide for the LED Command Center

Scantronic Leading the way in security

Master User Guide Veritas Excel. Issue 2

Intelligent GSM Auto-Dial Alarm System

Installation and Programming Guide

GSM ALARM SYSTEM USER MANUAL

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

Installation Manual for D1110 DigiCom2

SD1+ Speech Dialler. Installation and Programming Guide. Programming

USER INSTRUCTIONS CONTENTS

Galaxy 2 Series. User Guide. Honeywell Security

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

SCORPION. micron security products

ICP-CC488. Installation Guide ICP-CC488 Control Panel

HomeSafe Security Panel User s Guide 5400 Series

astec Integrated Alarm System USER GUIDE

Business/Home GSM Alarm System. Installation and User Manual

ALARM SYSTEM USER GUIDE

Matrix 424/832/832+ ICON & LCD User Manual. Software Version 5 RINS EN Security Grade 2 Environmental Class 2

P/N Rev D

WIRELESS HOME ALARM SYSTEM (WHA1)

NESS D8 ALARM CONTROL PANEL AND DIALLER USER S MANUAL. NESS D8 CONTROL PANEL V4 USER MANUAL Revision 5 A$12.00 INC GST

Mobile Data Power Model: MDP-25

User Guide Premier Elite 24/48/88/168/640

1R / 4-BUTTON SERIES

Transcription:

9448 Installation and User Guide Compatible Equipment 9040 Internal Sounder 660 Speech communicator 496327 Issue 1 1 of 6

9448 INTRODUCTION The 9448 is a 3 zone control panel with separate Entry/Exit and PA zones, designed specifically for domestic installations. The control unit PCB is built into a polycarbonate box with keypad and eight indicator LEDs on the front of the lid. Dimensions Weight Power Supply System Power Supply Quiescent Panel Power Standby Battery Outputs Technical Specification h x w x d 212 x 212 x 68mm. Approx 1.1kg (without stand-by battery). 230VAC (Ambient Temp. 20 º C). 70mA nominal. 12 Volt, 2.1AH rechargeable lead-acid, Gel Type battery. Bell, Strobe, and O/P are open collector transistor outputs. Bell, Strobe 500mA Max. AUX (for detectors) 300mA, 12VDC. Communicator Outputs PA, Intruder*. Outputs PIR Set Latch/Shock Sensor Reset. LS 9040 (1 max). Fuses F1 - Battery F2-12V AUX 2A Quick Blow. 1A Quick Blow. Caution: When replacing fuses use the ratings quoted above. * The control panel has none of the required software functions to allow it to conform with the required standards for remote signalling in the UK. Scantronic recommend that you use this system for "bell only" installations. Wiring Figure 1 shows the layout of the 9448 PCB and its connector. 2 of 6 496327 Issue 1

9448 Programming Figure 1. 9448 PCB Layout Initial Start Up Programming Before applying power to the control panel, ensure that all zone circuits are connected (link out any circuits not used). DO NOT connect the 12V terminal to the external sounder or 12VAUX terminals to the detectors at this stage. Caution: You may damage the panel if you connect bell and AUX power before you power up the system. 1. Apply mains to the control panel. The green power LED lights and the internal sounder will sound. Ignore any other lights. 2. Key-in the factory default user access code: 1234. The internal sounder stops. Ignore any other lights. 496327 Issue 1 3 of 6

Changing Default Programming 9448 3. Key-in 0 then ENTER followed by the factory default engineer access code: 7890. The Day LED goes off. 4. Open the control panel lid. You are now in programming mode. Changing Default Programming To change the factory defaults, the panel must be in programming mode. Then: 1. Key in a two digit programming command followed by "ENTER". (See "Engineer Program Command List".) 2. Key in the correct digit for the option you want, and then press ENTER. The panel beeps twice to show that it has accepted the command. The panel gives a single error tone if you enter an incorrect command (or if you close the lid). Re-enter the correct command. 3. Key in "99 ENTER" to leave programming mode when you have finished. You will then be in user mode. Engineer Program Command List To change: Key-in: Followed by: Notes Defaults Engineer Code 20 ENTER new code ENTER 4 digits 7890 User Code 1 21 ENTER new code ENTER 4 digits (see note 1) 1234 Zone 2 Entry 36 ENTER 0 ENTER Normal Alarm y Route 1 ENTER Entry Route Auto Re-Arm 40 ENTER 1 ENTER Never rearm y 4 ENTER Rearm three times Bell Duration 42 ENTER 1 ENTER 90 seconds 2 ENTER 3 minutes 3 ENTER 10 minutes 4 ENTER 20 minutes y Entry time 43 ENTER 1 ENTER 20 seconds y 2 ENTER 1 minute 3 ENTER 2 minutes 4 ENTER 4 minutes Exit time 44 ENTER 1 ENTER 10 seconds y 2 ENTER 30 seconds 3 ENTER 1 minute 4 ENTER 2 minutes Bell Trigger Type 50 ENTER 0 ENTER SAB y 1 ENTER SCB 4 of 6 496327 Issue 1

9448 Leaving Programming Mode Prog O/P 51 ENTER 0 ENTER PIR set latch y 1 ENTER Shock reset Zone 1 in Part Set 52 ENTER 0 ENTER Normal Alarm y 1 ENTER Entry/Exit Walk Test 97 ENTER Trigger detectors. Press OMIT to exit test. Leave Program 99 ENTER (See note 2.) Notes: 1. The end user may change the user codes (see separate user guide). 2. If the internal sounder activates when you use this command then check the lid tamper, bell tamper, and the global zone anti tamper. Leaving Programming Mode 1. Connect the battery. 2. Complete the connections between the 12V terminal and the external sounder, and 12VAUX and the detectors. Note: The SAB module in the external sounder will continue to ring until the hold off supply is connected, or until the bell cover lid tamper switch is closed. 3. Close the panel lid. 4. Key in "99 ENTER" to leave programming mode. You are now in user mode. To Re-enter Programming Mode You can re-enter programming mode at any time when the panel is in the unset mode: Key-in 0 then ENTER followed by the engineer access code. Open the control panel lid. You are now in programming mode. Restoring Factory Defaults The control panel can retain all programmed information and access codes if both mains and battery power fail. When power is restored the panel will simply need resetting with the customer or engineer's access code. If the installer wants to return the panel to the factory default settings, then: 1. Power down the control panel, mains and battery. 2. Locate the pair of Molex pins marked 'RST' near the microcontroller. 3. Place a small screwdriver blade to short between the 'RST' pins. 4. With the blade still across the pins, apply battery power then mains. The system loads the factory default user and engineer's access codes. 496327 Issue 1 5 of 6

Eningeer Walk Test 9448 5. Remove the screwdriver blade. 6. Key in 1234. 7. Key in 0 then ENTER followed by 7890. 8. You must now reprogram the system. Engineer Walk Test Allows the engineer to test all devices on the system. 1. Enter programming mode. 2. Key in "97 ENTER". The panel gives a continuous tone. 3. Open and close each detector contact in turn. When a detector contact is open the panel gives an interrupted tone and flashes the zone LED. 4. Press OMIT to stop the walk test. Note that the Engineer's walk test allows you to test all zones including PA zones, zone tampers, and panel and bell tampers. The user's walk test does not allow this. User Commands Set/Unset System Omit zone/part set Test Bells Walk Test Change User code User code 2 + OMIT and/or 3 + OMIT + User code 4 + ENTER + User code The system sounds the internal sounder for three seconds, followed by the bell and strobe for three seconds. 5 + ENTER User code Key in User code to end test 6 + ENTER + current user code new user code + ENTER 6 of 6 496327 Issue 1