TRIPLETT TDR. Cable Fault Finder. Instruction Manual



Similar documents
INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

USB Rover port USB m Cat 5 Extender. User Guide

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

HVAC Clamp Meter. Users Manual

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Advanced Systems Tester 900AST

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

KVM - DVI, USB 2.0, Cat 5 Extender

i410/i1010 AC/DC Current Clamp

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Installation Guide Smart-UPS X External Battery Pack SMX120BP

User Guide. Model Insulation Tester / Megohmmeter

BroadBand PowerShield. User Manual

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions

Safety Information. 2 Safety Information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

How To Install A Power Supply (Uplast) With A Battery Pack

Ground Resistance Clamp-On Tester

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

Benchtop Computer Monitor Generator

PixController, Inc. Wireless Digital PIR Sensor

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

Seven function digital multimeter

HDMI over Cat5 Video Extender with RS232 and IR Control

Installation and Operation Guide for PD4100 Series Power Control Centers

USB/VGA Cat 5 UTP Console Extender

Manual Ranging MultiMeter

MicroScanner 2. Users Manual. Cable Verifier

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

Wireless Indoor/ Outdoor Thermometer

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

MicroScanner 2. Cable Verifier. Getting Started Guide

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Pocket Tach 99 (PT99) Non-Contact Tachometer

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

User's Guide. True RMS Industrial Multimeter

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

3 WATT LED SPOTLIGHT Model No. SLM

Dynatel 2273 Advanced Cable and Fault Locator

Coax Mapping Tester User's Guide.

24.2L M.A.N. V12 Engine Module

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

User s Manual. Bluetooth Calculator Keypad. Page

Multi Media Cable Tester TM-901N/TM-902/TM-903

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Automatic Phone-Out Home Monitoring Systems

Installation and Operation Guide for PD4000 Series Power Control Center

AutoRanging Digital MultiMeter

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Architect/Contractor Information Package

Model UT201/202: OPERATING MANUAL. Table of Contents

Ultrasonic Distance Meter. Operation Manual

Dual-Cool Notebook Cooler Pad. User s Manual

How To Use A Cdm250 Digital Multimeter

Section 1: Introduction Section 2: igolf Neo Section 3: igolf Neo Sync Section 4: Appendices... 26

AVerMedia AVerKey imicro User s Manual

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

Optical Wireless Mouse. User s Manual

TABLE OF CONTENTS 11.0 WARRANTY

LDG DTS-4/4R Desktop Coaxial Switch / Remote

User Guide. 4 wire Earth Resistance Tester Model GRT300

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

1. SAFETY INFORMATION

User Manual PT-E-HIP

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Powerware Relay-Serial Card User s Guide

User's Guide. Integrating Sound Level Datalogger. Model Introduction


Owner s Manual & Safety Instructions

INSTRUCTION MANUAL MODEL PCD-88

AXIS T81B22 DC 30W Midspan

User and Installation Guide

Advantium 2 Plus Alarm

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

User Manual (English)

ACL 800 MEGOHMMETER OPERATION MANUAL

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

USB Port Hub with USB Power Cable. User s Manual

Stretch DisplayPort TM

User Manual. CFG253 3 MHz Function Generator

Instructions A Amp AC/DC Current Probe

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Modular I/O System Analog and Digital Interface Modules

Handheld portable appliance testers

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

CABLE MODEM QUICK START

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Global Water Instrumentation, Inc.

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Transcription:

TRIPLETT TDR Cable Fault Finder Instruction Manual

Safety Warnings This Instrument meets the safety requirements of IEC 61010-1:1993. It is for use on de-energised circuits only, however the Instrument is protected against telephone network voltages (EN60950: 1999 Scn2.3). Connection to mains supply voltages will result in damage to the Instrument and/or a hazard to the operator. Hence the user must assume responsibility for ensuring his or her own safety. WARNING ONLY use the unit with non-energized or deenergized and suitably isolated circuits. Connection to AC power mains will damage the instrument and may cause user injury. Symbols used on Instrument! Caution: Refer to accompanying notes. CE Equipment complies with current EU directives Page 1

Standards UL 1311-1 and CUL 1311-1 Safety: IEC610101-1:1993 EMC BS/EN 61326-1:1997 ESD EM Burst Surge Conducted RF EMC Standard IEC 1000-4-2 IEC 1000-4-3 IEC 1000-4-4 IEC 1000-4-5 1EC 1000-4-6 Category of Pass A A A A A Page 2

Table of Contents 1. First Operation 2. The TDR Cable Fault Finder 3. Specifications 4. Principles of operation 5. Attaching a cable to the Fault Finder 6. Setting the cable type 7. Selecting a library cable type 8. Testing cables not included in library 9. How to determine unknown Vp settings 10. Measuring cable length 11. Checking networks (thin wire ethernet) 12. Accuracy 13. Theoretical and actual Vp 14. Battery 15. Trouble Shooting 16. Cable Library 17. Additional Features 18. Maintenance and Warranty Part # 84-891 Page 3

1. First Operation The TDR Cable Fault Finder comes complete with Alligator Clip adaptor Alkaline 9v PP3 cell Toolbelt Holster Carry Case IT IS IMPORTANT THAT YOU READ THIS HANDBOOK BEFORE OPERATING THE INSTRUMENT Remove all packaging, remove battery compartment cover and check that the battery is connected (see section 14). Page 4

2. The TDR Cable Fault Finder The Triplett TDR is a hand held battery powered unit designed to measure the length of copper power and communication cables, or indicate the distance to a fault on the cable, given access to one end only. Advanced signal processing techniques enable the TDR to identify opens and short circuits, and directly indicate the fault distance on an alpha-numeric display. An internal library of standard cable types enables accurate measurement without the necessity of entering Velocity of Propogation or Characteristic Impedance information. The TDR also incorporates an oscillating tone generator, that is detectable with a Triplett Hound, Hound 2, or Hound 3, for use in the tracing and identification of cable pairs. The TDR can be used to: Measure the length of cable on a drum, without the need to unwind, and given access to one end only. Measure segment lengths in a Local Area Network, and distance to a fault. Locate the distance to a fault on an installed cable run. Page 5

3. Specifications Approximate Range Coaxial Cable: 6400ft max (1999m) Structured Wiring: 2500ft max (750m) Telephone Cable: 2500ft max (750m) Resolution 0.1ft < 100ft & 1ft > 100ft Accuracy +/- 3% or 1.5ft Vp Range 0 to 99% Cable Library 39 Standard Cable Types Tone Generator Oscillating between 810Hz and 1110Hz Display Alpha-numeric LCD Connector BNC Battery 9v PP3 Alkaline cell Battery Life Better than 2000 tests Temperature 32 to 112 deg F (0 to 40 deg C) Storage Temp. 0 to 150 deg F Dimensions 7.9 x 3.1 x 1.4 Weight less than 0.55lb Safety IEC1010-1 EMC To EU directives UL, CUL and CE Approved 4. Principles of Operation The TDR works by measuring the time taken for a signal to travel to the far end of the cable (or to an intermediate fault) and to return. The velocity at which the signal is transmitted (Velocity of Propagation ie. Vp) will depend on the characteristics of the cable under test. Page 6

5. Attaching a cable to the TDR 1. Ensure that no power supply or equipment is attached to the cable to be tested 2. Check that the far end of the cable is either open or shorted (not fitted with a termination) 3. Attach the TDR to one end of the cable to be tested The cable attachment to the TDR is via a BNC Jack located at the top of the unit. For un-terminated cables use the alligator clip adaptor. Coaxial Cable Shielded Cable Connect the red clip to the center wire and the black clip to the shield. Connect the red clip to a wire adjacent to the shield of the cable and the black clip to the shield. Unshielded Twisted Pair Separate out one pair and connect the two clips to the two wires of a pair. Unshielded Multi-Conductor Cable Connect the clips to any two wires. Page 7

6. Setting the cable type Before the TDR can be used to take measurements, it needs to be set for the cable type to be measured. If the cable is listed in the library (see Section 16) then setting up is simply a matter of selecting the appropriate cable type. 7. Selecting a library cable type 1. Switch on the TDR with the ON/Off switch at the side of the unit 2. The display will show the previously selected cable setting with its Vp. For example E/net 9907 Vp=78% 3. Scroll through the library using the and keys to find the required cable type. The types are displayed in alphabetical order and listed in Section 16 of this user guide. When the TDR is switched off it automatically stores the last setting and will display this setting when powered up. Page 8

8. Testing cables not included in library If the cable type to be tested is not in the library, then it can still be tested if the Vp is known. If the Vp is unknown refer to Section 9. Using the Key scroll to the bottom of the library and beyond, until you find the the Vp settings from 99% downwards. 9. How to determine unknown Vp settings If the TDR is to be used with a cable type for which the Vp is unknown, this first must be determined. 1. Take a sample of the cable at least 60 feet in length 2. Measure its length by direct measurement 3. Connect to the TDR and adjust the Vp setting to give a reading of the correct length. This Vp setting can now be noted and used on unknown lengths of the same cable type. Page 9

10. Measuring cable length Set the cable type or the Vp for the cable to be measured and attach to the cable as described in section 5. Press the Key Assuming there are no shorts in the cable then the length of the cable will be displayed, in feet. For lengths less than 100ft this will be given to one decimal place. Length 63.9ft For lengths over 100ft the decimal place is suppressed. Length 345ft If there is a short in the cable then the distance to the short will be displayed. Short 40.2ft If the cable is outside the measurement range then the display will read: Length Out of Range or Short Out of Range Page 10

11. Checking networks (thin wire ethernet) While carrying out the following tests, equipment should NOT be connected to the network. Set TDR with network cable type ie. E/net 9907, remove 50Ω terminators from both ends of network. Connect TDR in place of one of the terminators. Press Length of network will be displayed as: Length XX.Xft Repeat measurement from other end of network The length shown should be the same from either end and indicate the total length of the network. If the lengths differ and are less than the expected, this is probably due to an open circuit in the network at the distance shown If displays of: Short XX.Xft are shown this indicates a short circuit in the network at the distance shown Disconnect TDR and refit terminators. Page 11

12. Accuracy For coaxial twisted pair and shielded types an accuracy of ±5% can be expected, or ± 1.5ft at less than 30ft. The velocity of propagation is less well defined with unshielded multiconductor cable, including AC mains cable, and is lower when the cable is tightly wound on a drum than when it is installed. This is due to capacitance and inductance effects between the turns, therefore limiting accuracy to ±10% or ± 3ft at less than 30ft. The BNC to alligator clip adaptor has an effective length of 4 inches. 13. Theoretical and actual Vp Vp can, in theory be calculated from the dielectric constant, but actual values often differ slightly from the theoretical. In a real cable the dielectric may not fill the space between the conductors completely, and this has the effect of increasing Vp. In twisted pair cables the Vp depends to an extent on the pitch of the twist. The tighter the pitch the more dielectric and less air space and so the Vp is higher. This has an implication for Cat 5, where the different pairs are deliberately given staggered pitches to reduce crosstalk. Variation of Vp between pairs with Cat 5 is typically ±2%. Page 12

14. Battery The TDR requires a standard 9 volt alkaline battery. When the battery has become discharged, and needs replacing, the display shows: Low Battery To replace battery, switch off the TDR, remove battery cover and replace battery. Replace the cover. If display shows: 15. Trouble Shooting Check length of cable under test is within specified range of TDR Check connections from TDR to cable under test. Check for open circuit in cable at less than 5 feet. Check alligator clip to BNC adaptor lead. Connect alligator clips together, press If display reads: Length Out of Range Short Out of Range Then the adaptor lead is OK. Page 13

If display reads: Length Out of Range Then the adaptor lead needs replacing or repairing. If display shows: Short Out of Range Check cable under test for short circuit at less than 7.5ft. Check that terminators have been removed from network. Length to short circuit is outside of range, check by reconnecting to opposite end of cable if possible. If the display shows: Low Battery Replace battery. If the display is blank: Check if good battery is installed in TDR. Install or replace battery If cable length measurement appears to be inaccurate: Check that cable type or Vp value have been correctly selected Conductors within cable may be broken, select alternative conductors if available. Page 14

Appletalk BT2002 Coax Air 50Ω Coax A/S 75Ω Coax Solid PE 50Ω Ethernet 9880 Ethernet 9907 IBM Type 9 RG6/U RG59 B/U T/Pair PE T/Pair Paper 72nF Twinax 100Ω 16. Cable Library Belden 8102 CAT5 STP Coax Air 75Ω Coax Foam PE 50Ω Coax Solid PE 75Ω Ethernet 9901 IBM 1/2A/6 Mains BS6500 RG58 (8219) RG62 A/U T/Pair PTFE T/Pair Paper 83nF URM70 Coax Belden 9933 CAT 5 UTP Coax A/S 50Ω Coax Foam PE 75Ω CW1308 Ethernet 9903 IBM Type 3 Multicore PVC RG58 C/U Jelly PE T/Pair PVC Twinax 78Ω URM76 Coax Page 15

17. Additional Features Units of measurement Choice of Units. The Cable Fault Finder will display cable lengths either in meters or feet. To change the units to be used, switch the TDR off, then switch on while holding down the key. The unit in use, either Meters or Feet will be displayed. Toggle from one to the other using the switch off, then on again. key. To resume normal operation Tone Generator In Warble Mode the TDR generates a warbling tone, which is transmitted down the cable under test and can be picked up with a standard tone probe like the Triplett Hound 2 or Hound 3 (optional). This facilitates cable tracing. To select Warble Mode, switch the TDR off, then switch on again while holding down the key. The message Warble will appear on the display. To resume normal operation switch off, then on. Page 16

18. Maintenance and Warranty No regular maintenance of the Triplett TDR is required. In the event the product is defective or is damaged, please contact Triplett for repair information. Triplett Product Return Instructions In the unlikely event that you must return your Triplett equipment for repair, the following steps must be taken. 1: Call 1-800-TRIPLETT to obtain a Return Material Authorization (RMA) number from Customer Service. 2: Enclose a copy of the original sales receipt showing date of purchase. 3: Clearly print the RMA number on the outside of the shipping container. 4: Return to: Triplett / Jewell Instruments 850 Perimeter Road Manchester, NH 03103 ATTN: Repair Dept. Page 17

Triplett Three Year Limited Warranty Triplett warrants instruments and test equipment manufactured by it to be free from defective material or workmanship and agrees to repair or replace such products which, under normal use and service, disclose the defect to be the fault of our manufacturing, with no charge within three years of the date of original purchase for parts and labor. If we are unable to repair or replace the product, we will make a refund of the purchase price. Consult the Instruction Manual for instructions regarding the proper use and servicing of instruments and test equipment. Our obligation under this warranty is limited to repairing, replacing, or making refund on any instrument or test equipment which proves to be defective within three years from the date of original purchase. This warranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way so as, in our sole judgment, to injure their stability or reliability, or which have been subject to misuse, abuse, misapplication, negligence, accident or which have had the serial numbers altered, defaced, or removed. Accessories, including batteries and fuses, not of our manufacture used with this product are not covered by this warranty. To register a claim under the provisions of this warranty, contact Triplett s Customer Service Department for a Return Authorization Number (RMA) and return instructions. No returned product will be accepted without an RMA number. Upon our inspection of the product, we will advise you as to the disposition of your claim. Page 18

Triplett Three Year Limited Warranty ALL WARRANTIES IMPLIED BY LAW ARE HEREBY LIMITED TO A PERIOD OF THREE YEARS FROM DATE OF PURCHASE, AND THE PROVISIONS OF THE WARRANTY ARE EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED. The purchaser agrees to assume all liability for any damages and bodily injury which may result from the use or misuse of the product by the purchaser, his employees, or others, and the remedies provided for in this warranty are expressly in lieu of any other liability Triplett may have, including incidental or consequential damages. Some states (USA ONLY) do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. No representative of Triplett / Jewell Instruments or any other person is authorized to extend the liability of Triplett in connection with the sale of its products beyond the terms hereof. Triplett reserves the right to discontinue models at any time, or change specifications, price or design, without notice and without incurring any obligation. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Page 19