DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications



Similar documents
How is Dew Point Measured Reliably?

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

Instruction Manual. T3111 T3111L T3111P T3111Ex

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Duct Humidity Transmitter

Micro Motion 3098 Gas Specific Gravity Meter

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

OEM-EP Pressure Controllers

Typical Aluminum GFM Mass Flow Meter

Hand-held thermometer Model CTH7000

Handheld portable appliance testers

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Dew-Point Measurement Solutions

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

PortaSens ll G AS DETECTOR

Test equipment for temperature and its reduction

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

USB-500/600 Series Low-Cost Data Loggers and Accessories

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

TORKEL 820 Battery Load Unit

Mass Flow Meters & Controllers

Online Infrared Flue Gas Analyzer Gasboard 3000

USB-500/600 Series Low-Cost Data Loggers and Accessories

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15

IFC 070 Technical Datasheet

Hydraulic Control Solutions

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

COMBIMASS. Technical Data COMBIMASS eco-bio +

Digital inductive conductivity transmitter

Laminar Flow Elements

How To Use An Irius Pid Detector

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

USB-500 Series Low-Cost Data Loggers and Accessories

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Vaisala Weather Transmitter WXT510 The Most Essential of Weather

Long Distance Industrial Wireless Transmitters and Receivers

Rense Product Range. Customized Humidity Solutions. Rense Product Range

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Multifunction HVAC and IAQ Meter

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Battery Powered Thermal Mass Flow Meters for Gases

1. SAFETY INFORMATION

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Pressure Dew Point Probe / Application Information

Integrating Sound Level Meter and Datalogger

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

ThermoSorb Desiccant Dryers

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

Measuring electric and magnetic fields

S300 Series Dust Monitors

API Marine. BMS Presentation. Ballast Measurement Systems

RTD Temperature Probe for the Food/Pharmaceutical Industry

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Models SFP33 & SFP32 Pressure Transmitters

Precision digital pressure gauge Model CPG1500

Battery Powered Thermal Mass Flow Meters for Gases

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Relative and absolute pressure switch type 529

Nirvana. Cycling Refrigerated Dryers

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

PRODUCT PROFILE FEATURES

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Pressure transmitter For general industrial applications Model A-10

How To Use A Flowmeter

Highly efficient flue gas analyzer

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

PIEZOMETER AIRFLOW MEASURING RING

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Refrigeration Air Dryers. Catalogue

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

Current Monitoring Kit

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Electromagnetic Flow Meter

Thermal Mass Flow Meter (Series MST)

KNC Model 3666 Automatic Pressure Calibration System

Turbine Flowmeters for Gas Applications

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

General Purpose ph/orp Sensors

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

How To Use A Ds340 (Dsp)

Refrigerated Air Dryers. Catalogue

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

Transcription:

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications P.O. Box 26, FIN-00421 Helsinki, FINLAND Tel: +358 9 894 91 Fax: +358 9 8949 2485 Email: industrialsales@vaisala.com www.vaisala.com The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 offers accurate and fast measurement for industrial dewpoint applications, such as compressed air, metal treatment and plastics drying. Features/Benefits Designed for industrial spot checking and field calibration Three models: accurate measurement ranges from -60 to +60 C (-76 +140 F) Vaisala DRYCAP Sensor with patented autocalibration function Low maintenance need due to superior long-term stability Sensor withstands condensation Fast response, enhanced by Sensor Purge option Easy-to-use user interface Data can be logged and transferred to a PC via MI70 Link software Compact, small and light NIST traceable (certificate included) The Vaisala DRYCAP Hand-Held Dewpoint Meter DM70 measures dewpoint temperature accurately over a wide measurement range. The probe may be inserted directly into pressurized processes, and it responds rapidly from ambient to process conditions. The sensor withstands condensation and fully recovers from getting wet. Three DMP74 probe models Three probe models, all with autocalibration, are available. The A and B models are both general purpose probes. The A model is for dewpoint range from -40 to +60 C T d, and the B model for -60 to +20 C T d. The C model is specifically developed for SF 6 gas with a dewpoint range down to -50 C T d. The B and C probe models have an additional Sensor Purge feature. The Sensor Purge heats and dries the sensor, making the response from ambient to dry conditions exceptionally fast. This facilitates rapid spot checking measurements in low dewpoints. Low maintenance due to innovative autocalibration The DM70 is fitted with the Vaisala DRYCAP Sensor. The sensor provides reliable and high-performance dewpoint measurement with revolutionary long-term stability. The patented autocalibration procedure detects on-line possible measurement inaccuracies and automatically corrects dry-end drift in the calibration curve. These advanced features provide a long calibration interval and low maintenance cost. The meter is calibrated in the factory against internationally traceable standards and delivered with a calibration certificate. The DM70 can also be sent to a Vaisala Service Center for a traceable recalibration. Easy-to-use user interface The DM70 has a versatile and easy-touse, menu-based user interface and a clear graphical LCD display with datalogger function. It can also be used as a tool for reading the output of fixed Vaisala dewpoint transmitters, like the DMT242, DMT142 and DMP248. Various display variables The DM70 displays one to three parameters at a time, either numerically or graphically. Several humidity units can be selected. In addition, the DM70 includes conversion from gas pressure dewpoint to ambient pressure dewpoint. An analog output is also available. The graphical display helps the user to know when the dewpoint plateau is reached. 66 Vaisala Instruments Catalog 2005

DM70 DEWPOINT Technical Portable Sampling Data System and Sampling Cells MI70 Link PC connection The DM70 has a MI70 Link Windows software program for transferring logged and real time measurement data from the DM70 to a PC. Lightweight construction The DM70 is small and rugged, and therefore an ideal choice for demanding applications. The long battery life provides convenient use in the field. DSS70A portable sampling system The DSS70A is designed to provide dewpoint sampling flexibility. For processes at atmospheric pressure, a battery powered pump is used to extract a gas sample. For pressurized processes up to 20 bar, the sample is measured at process pressure and then reduced to atmospheric pressure for venting or re-direction, bypassing the pump. In all cases, the sample gas passes through a filter to remove particulate contamination before measurement. Flow through the system is controlled and monitored with a needle valve and flow meter. The DSS70A is easily connected to an appropriate sample point with tubing (typically 1/4" or 6 mm). The measured dewpoint must be below ambient temperature to avoid condensation in the system. Gas temperatures higher than +40 C (+104 F) should be cooled with a short PTFE or stainless steel tube prior to entering the DSS70A. Sampling cells for pressurized processes The DM70 can easily be connected to pressurized processes. In addition to direct pipeline installation, a variety of sampling cell options are available for gas sampling. The DSC74 sampling cell is the recommended choice. It has a variety of connection adapters that allow several different ways of installation. The quick connector with a leak screw allows a very fast connection for compressed air lines. Additionally, two thread adapters are available for the inlet port. The DSC74B is a two-pressure sampling cell, which enables measurements in both process and ambient pressure. This sampling cell is especially suitable for dewpoint measurements in SF 6 gas with the DMP74C probe. The DMT242SC is a basic sampling cell. The DMT242SC2 is a sampling cell supplied with welded Swagelok connectors for sampling in a 1/4" pipeline. The DSS70A provides a compact solution for field checking dewpoint where direct measurement is difficult. Typical applications for the sampling system are metal treatment and plastics drying processes. DM70 Accessories The DM70 meter is suitable for direct dewpoint measurements in the process in a wide temperature and pressure range. For more demanding applications, the DM70 can be used with the Vaisala sampling cell adapters, or with the Vaisala DRYCAP Sampling System DSS70A. Vaisala Instruments Catalog 2005 The sampling cells (from the left) DMT242SC2, DMT242SC and DSC74 can be used to connect the DM70 to sample gas flow. The DSC74B (right) is a two-pressure sampling cell that can be used for measurements in either pressurized or ambient pressure. The cooling/venting coil is an option for all sampling cells. 67

Technical Data P.O. Box 26, FIN-00421 Helsinki, FINLAND Tel: +358 9 894 91 Fax: +358 9 8949 2485 Email: industrialsales@vaisala.com www.vaisala.com DSS70A Sampling System and DSC74B/C Sampling Cells Sample Gas Inlet The DSS70A sampling system includes a filter to clean the dirty sample gas and a needle valve to control the sample flow rate with the flow meter. A sample pump is used to generate a sample flow from processes at ambient pressure. Measurement in gas pressure inlet Measurement in atmospheric pressure inlet Filter DSS70A DSC74B Removable flow limiter DSC74B DSC74C Sampling Cell for Td Probe Sampling Cell for Td Probe Needle Valve Valve Valve Flow meter Removable flow limiter Sampling Cell for Td Probe Sample Pump Diffusion coil outlet Sample Gas Outlet outlet The DSC74B sampling cell enables the measurement of the sampled gas either in gas pressure up to 10 bar or in atmospheric pressure depending on the gas inlet and outlet. The DSC74C is like the DSC74B but with an additional coil to avoid back diffusion, the effect of surrounding moisture, in dewpoint measurements in atmospheric pressure. DM70 hand-held dewpoint meter (DMP74 probe + MI70 indicator) General Battery operation time continuous use 48 h typical at +20 C (+68 F) data logging use up to 30 days Housing materials ABS/PC blend Storage temperature -40...+70 C Storage humidity 0...100 %RH non-condensing Total weight 750 g Accessories Connection cables for fixed Vaisala dewpoint transmitters for DMT242 transmitter order no: 27160ZZ for DMP248 transmitter order no: 27159ZZ for DMT142 transmitter order no: 211917ZZ Analog output cable order no: 27168ZZ Windows software, includes PC connection cable MI70LINK 10 m (32.81 ft) extension cable for probe 213017SP MI70 indicator Indicator general Menu languages English, French, German, Spanish, Swedish, Finnish Display LCD with backlight Graphic trend display of any parameter Character height up to 16 mm Probe inputs 1 or 2 Power supply Rechargeable NiMH battery pack with AC-POWER or 4xAA size alkalines, type IEC LR6 Analog output 0...1 VDC Output resolution 0.6 mv Data interface RS232 Datalogging capacity 2700 points Alarm audible alarm function Operating temperature range -10...+40 C (+14 +104 F) Operating humidity range non-condensing Housing classification IP54 Weight 400 g 68 Vaisala Instruments Catalog 2005

DM70 DEWPOINT Technical Data DMP74 dewpoint probes Measured variables, DMP74A probe Dewpoint Measurement range (typical) -50...+60 C (-58 +140 F) Accuracy (A probe) -40...+60 C ±2 C (±3.6 F) (see graph below) Dewpoint temperature ( C) 70 60 50 40 30 20 10 0-10 -20-30 -40-50 -60-70 -80-10 Accuracy < ± 2 C Td Dewpoint measurement range lower limit 0 10 20 30 40 50 60 Process temperature ( C) Response time flow rate 0.2 m/s, 1 bar pressure, +20 C (+68 F) 63% [90%] 0 -> -40 C T d (32 -> -40 F T d ) 20 s [120 s] -40 -> 0 C T d (-40 -> 32 F T d ) 10 s [20 s] Dewpoint sensor Vaisala DRYCAP 180S Dewpoint converted to atmospheric pressure Dewpoint range for converted Td (20 bar to 1 bar) with ±2 C (±3.6 F) accuracy -64...+60 C (-83...+140 F) Temperature Measurement range -10...+60 C (+14 +140 F) ±0.2 C (±0.36 F) Typical temperature dependence of electronics ±0.005 C/ C (±0.005 F/ F) Temperature sensor Pt100 IEC751 1/3 class B ppm volume and ppm weight concentration Measurement range (typical) 40...200 000 ppm ±(7.3 ppm + 8.3% of reading) Relative humidity Measurement range 0...100 %RH RH < 5 % ±(0.025 %RH + 17.5% of reading) RH > 5 % ±(0.8 %RH + 2% of reading) Measured variables, DMP74B and DMP74C (for SF 6 gas) probes Dewpoint Measurement range (typical) -70...+30 C (-94 +86 F) Accuracy (B and C probe) -60...+20 C ±2 C (±3.6 F) (see graph below) Dewpoint temperature ( C) 70 60 50 40 30 20 10 0-10 -20-30 Accuracy < ±2 C Td -40-50 -60-70 -80 Dewpoint measurement range lower limit Dewpoint measurement range high limit -10 0 10 20 30 40 50 60 Process temperature ( C) Dotted line: For DMP74C the ±2 C accuracy range is limited to -50 C T d when used in SF6 gas. Response time flow rate 0.2 m/s, 1 bar pressure, +20 C (+68 F) 63% [90%] 0 -> -60 C T d (32 -> -76 F T d ) 50 s [340 s] -60 -> 0 C T d (-76 -> 32 F T d ) 10 s [20 s] Dewpoint sensor Vaisala DRYCAP 180M Dewpoint converted to atmospheric pressure Dewpoint range for converted Td (20 bar to 1 bar) with ±2 C (±3.6 F) accuracy -80...+20 C (-112...+68 F) Temperature Measurement range -10...+60 C (+14 +140 F) ±0.2 C (±0.36 F) Typical temperature dependence of electronics ±0.005 C/ C (±0.005 F/ F) Temperature sensor Pt100 IEC751 1/3 class B ppm volume and ppm weight concentration Measurement range (typical) 2...40 000 ppm < 40 ppm ±(0.5 ppm + 25.4% of reading) > 40 ppm ±(7.3 ppm + 8.3% of reading) Measurement environment, all probe models Temperature -10...+60 C (+14 +140 F) Pressure DMP74A 0...20 bar a (0...290 psia) DMP74B DMP74C 0...20 bar a (0...290 psia) 0...10 bar a (0...150 psia) Sample flow rate no effect for measurement accuracy General, all probe models Measured gases non-corrosive gases Probe material (wetted parts) Stainless steel (AISI 316L) Sensor protection Sintered filter (AISI 316L) partno: HM47280 Mechanical connection G1/2" ISO228-1 thread with bonded seal ring (U-seal) Housing classification IP65 (NEMA 4) Weight 350 g Vaisala Instruments Catalog 2005 69

Technical Data and Dimensions P.O. Box 26, FIN-00421 Helsinki, FINLAND Tel: +358 9 894 91 Fax: +358 9 8949 2485 Email: industrialsales@vaisala.com www.vaisala.com Sampling cells technical data DSC74 sampling cell for pressurized gases 1 MPa (10 bar g, 145 psig) DSC74B two pressure sampling cell 1 MPa (10 bar g, 145 psig) DSC74C DSC74B with DMCOIL cooling/venting coil DMCOIL cooling/venting coil DMT242SC sampling cell DMT242SC2 10 MPa (100 bar g, 1450 psig) sampling cell with Swagelo g connectors 4 MPa (40 bar g, 580 psig) Material for all sampling cells stainless steel AISI316 DSS70A sampling system Operating conditions Operating gases Dewpoint range air, N 2 and other non-toxic, inert gases -60 C...T amb (-76 F T amb ) Inlet/outlet connection 1/4" SWAGELOK Operating temperature ambient temperature 0...+40 C (32 +104 F) process gas temperature with PTFE tube at +20 C (+68 F) max. +200 C (+392 F) with stainless steel tube specification according to stainless steel tube specification maximum gas temperature at inlet +40 C (+104 F) Operating pressure with pump 0.6...1.2 bar a (8.7...17.4 psia) pump disconnected 0...20 bar a (0...290 psia) General Battery operation time for pump 8 h continuous use battery can be recharged using DM70 charger Filter 7 mm inline filter cartridge 1/4" SWAGELOK SS-4F-7 (spare part order no. 210801) Materials wetted parts Stainless steel carrying case ABS plastic Case size (W x D x H) 430 x 330 x 100 mm Weight 5.5 kg (12 lbs) Electromagnetic compatibility Complies with the EMC standard EN61326-1:1997 + Am1:1998 + Am2:2001; Generic Environment. Dimensions Dimensions in mm (inches). DSC74, same as the body of DMT242SC and DMT242SC2. SW 24mm (0.94) 72 (2.83) 35 (1.38) 32 (1.26) G1/2" 32 (1.26) G1/4" G3/8" (G1/4") 28.5 (1.22) 18 (0.71) 22 (0.87) Cooling/ venting coil DSC74B/C MI70 indicator DMP74 probe Cable length 2 m (6.56 ft) 12 m (39.37 ft) cable optional DRYCAP is a registered trademark of Vaisala. Specifications subject to change without prior notice. Vaisala Oyj 70 Vaisala Instruments Catalog 2005

DEWPOINT Technical Dry without Data a Doubt Excess moisture in compressed air can cause many problems both to the end product and to the components in the air distribution system itself. The DM70 can be used for spot measurements at the compressed air line or for field checks of other dewpoint transmitters. Photo: Atlas Copco To ensure the best quality and yield of end products plastics must be sufficiently dry before further processing. The DM70 provides an easy method for checking the plastic dryer performance. Dewpoint is an important parameter in moisture measurement and control of SF 6 gas insulated equipment, such as high voltage switchgear. The DM70 is an easy and fast hand-held instrument for dewpoint measurement with direct sampling. Photo: Areva T&D Vaisala Instruments Catalog 2005 71