Petrol Storage Information Note

Similar documents
Petroleum (Consolidation) Regulations 2014

Fire & Explosion Risks in Service Stations

FIRE SAFETY GUIDANCE NOTE Risk Assessments for Petrol Filling Stations Required Under Fire Safety Legislation

Site and Storage Conditions for Class 3.1 Flammable Liquids

REFERENCE NUMBER : PPC/54. POLLUTION PREVENTION AND CONTROL ACT 1999 POLLUTION PREVENTION & CONTROL (ENGLAND AND WALES) REGULATIONS 2000(as amended)

Performance Standard for Secondary Containment

UPDATE ON MAINE'S UNDERGROUND TANK LAWS

September 2008 AFC (2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations

The Pipelines Regulations, 2000

The Control of Major Accident Hazards Regulations (Northern Ireland) 2015

Cyan 100% Magenta 76% Yellow 0 Black 27% Wetstock Reconciliation at Fuel Storage Facilities. An Operator s Guide

Reporting dangerous goods incidents. Guideline (6th edition)

Civil Engineering Sector Labour-Management Health and Safety Committee

The Electrical Safety Regulation (pre and post 1 January 2014)

CHAPTER PETROLEUM CONTACT WATER

How To Manage A Fire Explosion

The National Road Traffic Act 93 of 96

LPG, Flammable Liquids, Toxic and Corrosive Substances

ALL UST SYSTEMS. MOTOR FUEL, USED OIL, BULK HEATING OIL STORAGE (Federal/State Regulated Systems)

Incident Reporting Requirements

A guide for service station operators

FUELING AND FUEL STORAGE

Health and Safety Management in Healthcare

LIQUEFIED PETROLEUM GAS CHAPTER 218

Fuels Safety Program. Liquid Fuels Handling Code Adoption Document Amendment

Licence condition handbook

Guide to Certification for Retail Hardware Stores

COMPLIANCE MANAGEMENT STRATEGIES. Presented by: Megan Kazmierczak, ECS Eclipse

NDEP Bureau of Corrective Actions Secondary Containment Regulations Guidance Document April 7, 2010 (Revision)

HAZARDOUS MATERIALS MANAGEMENT ISSUE 2

Public Health (Wales) Bill

EAST LINDSEY DISTRICT COUNCIL ~ RESIDENTIAL CARAVAN SITES CONDITIONS OF SITE LICENCE

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

Environmental Protection Department March 2010

Management of Environmental Risks and Emergencies. Compliance Audit Program

Waste Oil Collection / Storage

PETROLEUM ACT, 1934 CHAPTER I : CONTROL OVER PETROLEUM

2016 No. 253 HEALTH AND SAFETY. The Health and Safety and Nuclear (Fees) Regulations 2016

FLAMMABLE LIQUIDS COMPLIANCE NOTE

District of Columbia Municipal Regulations UNDERGROUND STORAGE TANKS: GENERAL PROVISIONS 5500 COMPLIANCE WITH OTHER DISTRICT LAWS

2.0 Mandatory conditions for importing and marketing petroleum in Kenya: 2.1 Purchase of products from the Kenya Petroleum Refineries Limited:

NOTIFICATION OF PERFORMANCE TESTING FOR GASOLINE DISPENSING FACILITIES (GDFs) NESHAP 40 CFR, Part 63, Subpart CCCCCC (Sections

Examples of pressure systems and equipment are:

Pollution Incident Response Plan

Fact sheet 6: for farmers

CONDITIONS FOR SUPPLY OF SKIPS AND CONTAINERS AND FOR THE DISPOSAL OF THE CONTENTS OF THE SKIPS AND CONTAINERS

Environmental Management System Procedures

Economic and Social Council

No. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974

Health (Tobacco, Nicotine etc. and Care) (Scotland) Bill [AS PASSED]

Not Protectively marked

Farm Fuel Tank Safety Guide

OIL STORAGE REQUIREMENTS OF THE SPCC REGULATIONS. Christopher J. Ecsedy, P.E. Fuss & O'Neill, Inc. 146 Hartford Road Manchester, CT 06040

TAMPA BAY WATER Supplying Water To The Region

Energy Act 2011 CHAPTER 1 CONTENTS PART 1 ENERGY EFFICIENCY GREEN DEAL

REGISTER OF DELEGATIONS COUNCIL TO CEO Environmental Protection Act 1994

Chapter Four Taxable Services and Contractors

Inspection Location Standards

TITLE 29: EMERGENCY SERVICES, DISASTERS, AND CIVIL DEFENSE CHAPTER I: EMERGENCY MANAGEMENT AGENCY SUBCHAPTER d: STATE EMERGENCY RESPONSE

History of the SPCC Rule

End-of-life vehicles. Information for authorised treatment facilities

Harbour Town Adelaide Busking Permit Application Form

STANDARD SITE LICENCE CONDITIONS FOR RESIDENTIAL PARK HOME SITES IN GUILDFORD CARAVAN SITES AND CONTROL OF DEVELOPMENT ACT 1960 (AS AMENDED)

Arctic King Fuel Tanks meet the Environment Canada TECHNICAL REQUIREMENTS FOR COLLAPSIBLE FABRIC STORAGE TANKS (BLADDERS) - December 17, 2009

Guide for Contractors and Project Supervisors

4.7 HAZARDS AND HAZARDOUS MATERIALS

Standards and best practice guidelines for vapour recovery at petrol service stations. Department of Environment, Climate Change and Water NSW

Fact sheet 6: for farmers

DUTIES and GUIDANCE. for. BOARDS of MANAGEMENT. DEALING with ASBESTOS CONTAINING MATERIALS. before, during & after

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

CSA CONSTRUCTION, INC McAllister Road Houston, Texas SUBCONTRACTOR AGREEMENT

Fuel Tanker Online Content Monitoring. Petroleum Products Real Time! Solution for Modern Businesses

The Fuel Storage Tank Regulations 2009

Fair Trading (Fuel Prices) Amendment Bill 2013

BP Southern Africa (Pty) Ltd. Storage Facility Allocation Mechanism 2013/14. Version

MOTOR FUEL DISPENSING SAFETY

STANDARD FOR SECONDARY CONTAINMENT TESTING OF UNDERGROUND STORAGE TANK SYSTEMS I. INTRODUCTION

Last Updated: June 1, 2014

Storage Tank Systems for Petroleum products and allied petroleum products regulations

Underground Storage Tanks

SECTION THREE CONSTRUCTION CODES

For the Provision of animal collection and impound services.

Excavation & Trenching Procedure

Pollution Incident Response Management Plan

FUEL CARD PROGRAM - User Guide

Rider 101 Scope of Work CLEANING AND TREATMENT OF STORED #2 DIESEL FUEL

Safe use of liquefied petroleum gas (LPG) at small commercial and industrial bulk installations

DRAFT VEHICLE MAINTENANCE AGREEMENT BETWEEN THE COUNTY OF SANTA CLARA AND OUTREACH

ONTARIO REGULATION proposed to be made under the

Transportation of Soils Contaminated with Flammable Liquids

Motor Vehicle Claim Form

It is hereby notified that the President has assented to the following Act which is hereby published for general information:-

Street Trading Policy. Bradford District

JOINT CBA AND SIA GUIDANCE FOR THE STORAGE OF FLAMMABLE LIQUIDS IN SEALED PACKAGES IN SPECIFIED EXTERNAL STORAGE AREAS

Subpart XX Standards of Performance. Terminals. Environmental Protection Agency

On-Site Risk Management Audit Checklist for Program Level 3 Process

Sample Hazard Communications Program for Spray Polyurethane Foam Applications

DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIRECTOR'S OFFICE

Building Report & Consent

CONTRACT CONDITIONS FOR LOGISTICS (2014)

Transcription:

Petrol Storage Information Note The storage of petrol is governed by specific legislation. These regulations are entitled; Dangerous Substances (Retail and Private Petroleum Stores) Regulations, S.I. 311 of 1979, as amended, and are made under the Dangerous Substances Act, No. 10 of 1972. The Act requires that all petrol storage facilities must be licensed. The regulations set minimum requirements for the design, construction, installation, maintenance and management of petrol storage facilities, such as, storage tank specifications, petrol dispense control measures, certification of electrical systems, emergency control measures, storage tank pressure testing and training. These requirements apply equally to private petrol stores and storage for the purpose of retail sale (petrol filling stations). Private petrol stores include petrol held at business premises, e.g. golf clubs, public amenity centres, local authority parks department, car dealerships etc, storing petrol for their own use (not for re-sale) and storage of fuel held by private individuals. How to Obtain a Licence To be eligible for the grant of a licence a petrol store must meet the requirements of the Dangerous Substances (Retail and Private Petroleum Stores) Regulations, S.I. 311 of 1979 as amended. Licence applications may be made to the relevant local or harbour authority, which under normal circumstances for local authorities, is to your local Fire Authority for the attention of the Chief Fire Officer. All applications must be in writing and accompanied by the appropriate fee. For a first licence, applicants must submit site plans, drawings and particulars of tanks, dispensing pumps, associated equipment and relevant buildings. The licensing authority can advise on specific application requirements and associated fees. Information on fees may also be obtained by referring to the Dangerous Substances (Licensing Fees) Regulations, S.I. 301 of 1979, as may be amended. [If the petrol store is owned by a local or harbour authority, the licensing body is the Health and Safety Authority] Page 1 of 5

Licence Conditions The period of validity for a licence to store petrol may not exceed 3 years and the licensing authority may attach conditions to the licence. Licensing authorities have discretion to relax certain regulations or impose more stringent requirements dependent on the individual circumstances. Storage facilities that do not require a licence Certain quantities of petrol may be kept without a licence, however storing petrol over certain thresholds or in containers over a certain size; you are required to notify your local licensing authority (Fire Authority or Harbour Authority): Total Quantity Purpose of Petrol Use Licence required Notify licensing authority 3 x 5 litres Any use other than engine petroleum No No Over 3 x 5 litres Any use other than engine petroleum Yes Yes Up to 100 litres Engine petroleum : No No Petrol used in engines of any vehicle, ship, vessel, boat or aircraft, lawn mowers, generators, stationary engines etc. Not for re-sale. Must comply with storage regulations; see Part III of S.I. 311 of 1979. 100 to 273 Litres Engine petroleum No Yes Over 273 litres Engine petroleum Yes Yes Stored in containers over 23 litres capacity Engine petroleum No Yes Page 2 of 5

Note: The maximum quantity of engine petroleum that can be carried in/on a vehicle (other than the fuel tank of the vehicle) while in a public place, is limited to 2 x 10 litre metal containers. Kerbside or pre 1979 Petrol Stations The regulations take account of petrol stores built before 1979 which are unable meet the regulations in full due to the cost of re-design or engineering modification and physical constrains on the site. These allowances are at the discretion of the licensing authority and relate primarily to; underground tanks, the road tankerunloading stand and separation distances for manholes, tank vents, offset fill pipes and dispensers from the site boundary. These (retail) petrol stores often have dispensers located on or close to a public footpath and are known as kerbside sites. Licence applications are made as normal to the local licensing authority. Refusal of a Licence and Licence Appeals Appeals against a decision by a licensing authority to refuse the grant of a licence or to conditions attached to it must be made within 14 days to the Health and Safety Authority. Appeal submissions must be in writing setting out the claim in detail and be accompanied by a certificate from the licensing authority stating the reasons for the decision. Appeals should be sent to: RPPS Licence Appeals, Work Place Contact Unit, Health and Safety Authority, Metropolitan Building, James Joyce Street, Dublin 1. Late Appeals Where the applicant/licensee can demonstrate either agreement with the licensing authority on a suitable plan of action to address most of the reasons for a licence refusal or that substantial negotiations made in good faith have failed, then the Health & Safety Authority may accept a late appeal. Driver Controlled Deliveries The regulations require that petrol storage operators supervise all petrol deliveries. However, where the local licensing authority gives prior consent a petrol store may be modified to allow deliveries under the control of the road tanker driver only. Page 3 of 5

Further details regarding the modifications required for this purpose can be found in the Certificate of Exemption No. R.P.P.S.I Driver Controlled Deliveries available on the HSA web site. Leak Detection Underground petrol storage tanks (typically single skin steel tanks) become more susceptible to developing leaks after they have been in service for over 20 years. The regulations require, as a minimum, these tanks must be checked weekly to ensure that any leak may be detected at the earliest opportunity. It is advisable however that all tanks, whatever age, should be subject to wet stock monitoring on a regular basis and associated records kept for inspection. For further details on recommended wet stock monitoring, see the Health & Safety Authority publication Wetstock Inventory Control for Petrol Stations available on the HSA web site. As part of the required safety management of underground storage tanks and associated pipe-work, the Health & Safety Authority recommends leakproofness testing should be carried out as follows; two-yearly intervals for tanks over 20 years old annually for tanks in service for more than 30 years. This work should only be carried out by a competent contractor. Note: Modern systems such as double skin storage tanks with interstitial leak detection and fuel containment may not require the same checks as required for single skin tanks. These systems generally provide a higher level of safety in preventing fuel loss. In these cases you should follow manufacturers recommendations on use, training and system maintenance. Refurbishment or Modifications Before carrying out any work at a petrol station that may affect the safe storage of petrol the written permission of the local licensing authority must be obtained. This requirement only normally applies to construction work that might damage the underground tanks and pipelines or to work that introduces an ignition source into a hazardous zone within the site. The need to obtain written permission will not Page 4 of 5

generally apply to routine maintenance work or for the replacement of petrol dispensers. Abandoned Storage Tanks Disused underground petrol storage tanks pose a very high risk from fire and explosion unless the tanks are properly decommissioned. Removing the liquid petrol is not sufficient as petrol vapours remain in the tanks for many years and explosions have occurred in tanks that had not been used for over 30 years. The local licensing authority must be given 21 days notice in writing by the licensee or owner of the site, of the intention to decommission a petrol storage tank. The licensing authority may specify the method for decommissioning which must then be followed. On completion of the decommissioning process certificates of decommissioning should be promptly forwarded to the local licensing authority. Further Information: Licensing or notification queries may be submitted your Local Authority Fire Department or Harbour Authority as appropriate. Publications available on the HSA web site, www.hsa.ie under the Retail and Private Petroleum Stores (RPPS) sector: Wetstock Inventory Control for Petrol Stations Certificate of Exemption No. R.P.P.S.I Driver Controlled Deliveries Relevant regulations: Dangerous Substances Act, no.10 of 1972 Dangerous Substances (Retail and Private Petroleum Stores) Regulations, S.I.311 of 1979, as amended. Dangerous Substances (Licensing Fees) Regulations, SI 301 of 1979, as amended. Regulations are available via the HSA web site www.hsa.ie or directly from www.irishstatutebook.ie Queries regarding appeals or legislation enforcement may be directed by e-mail to wcu@hsa.ie or in writing to; Petrol Station Queries, Work Place Contact Unit, Health and Safety Authority, Metropolitan Building, James Joyce Street, Dublin 1 HSA WCU Locall: 1890 289 389 (Monday to Friday, 9am to 5pm) Page 5 of 5