Experiment C-31 Color Absorption



Similar documents
Experiment P-17 Magnetic Field Strength

2 Spectrophotometry and the Analysis of Riboflavin

Beer's Law: Colorimetry of Copper(II) Solutions

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

NEULOG HEART RATE AND PULSE LOGGER SENSOR GUIDE

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Appendix C. Vernier Tutorial

The Determination of an Equilibrium Constant

A Beer s Law Experiment

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

INTRODUCTION TO SPECTROMETRY

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Photosynthesis and Light in the Ocean Adapted from The Fluid Earth / Living Ocean Heather Spalding, UH GK-12 program

Electromagnetic Radiation (EMR) and Remote Sensing

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Using the Spectrophotometer

MAKING SENSE OF ENERGY Electromagnetic Waves

Photosynthesis and Cellular Respiration. Stored Energy

2C: One in a Million. Part 1: Making solutions. Name: Section: Date: Materials

Name Class Date. spectrum. White is not a color, but is a combination of all colors. Black is not a color; it is the absence of all light.

Color and Light. DELTA SCIENCE READER Overview Before Reading Guide the Reading After Reading

Upon completion of this lab, the student will be able to:

8.2 Cells and Energy. What is photosynthesis? Photosynthesis takes place in the chloroplasts. CHAPTER 8. Solar cells and chloroplasts

COLORIMETER. Description 0358BT. Figure 1. The Colorimeter

Effect of Light Colors on Bean Plant Growth

THE NATURE OF LIGHT AND COLOR

Evaluation copy. Case File 9. A Killer Cup of Coffee? GlobalTech manager dies

Lab #11: Determination of a Chemical Equilibrium Constant

Review Vocabulary spectrum: a range of values or properties

What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)

The Determination of an Equilibrium Constant

To determine the mass of iron in one adult dose of either a ferrous sulfate or. ferrous gluconate iron supplement using a colorimetric technique.

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

TEACHER ACTIVITY GUIDE

Principle of Thermal Imaging

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

Shimadzu UV-VIS User s Guide

Using Spectrophotometers to Examine Photosynthetic Rates Under Various Qualities of Light

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy

Measuring Manganese Concentration Using Spectrophotometry

Overview. What is EMR? Electromagnetic Radiation (EMR) LA502 Special Studies Remote Sensing

SYNTHESIS AND ANALYSIS OF SILVER/GOLD NANOPARTICLES

Measuring Protein Concentration through Absorption Spectrophotometry

Shielding Ourselves from Ultraviolet Light

Can Traffic Accidents be eliminated by Robots?

After a wave passes through a medium, how does the position of that medium compare to its original position?

Application Note: Absorbance

Green Heating. Pupil Research Brief. Teachers Notes. Syllabus Coverage Subject Knowledge and Understanding. Route through the Brief UPIL ESEARCHER

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Computer Vision: Machine Vision Filters. Computer Vision. Optical Filters. 25 August 2014

Drop Counter Sensor Product Number: ENDRP-AD100

A. Incorrect! No, while this statement is correct, it is not the best answer to the question.

Reaction Stoichiometry and the Formation of a Metal Ion Complex

1 Laboratory #5: Grating Spectrometer

Outline. Quantizing Intensities. Achromatic Light. Optical Illusion. Quantizing Intensities. CS 430/585 Computer Graphics I

Phosphates (ortho- and total)

Setting Up the MimioCapture Device

Computer Vision. Color image processing. 25 August 2014

Reaction of Blue Food Dye with Bleach

GETTING TO KNOW YOUR 4G USB

1. Three-Color Light. Introduction to Three-Color Light. Chapter 1. Adding Color Pigments. Difference Between Pigments and Light. Adding Color Light

Experiment #5: Qualitative Absorption Spectroscopy

INF-USB2 and SI-USB Quick Start Guide

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Zetasizer Nano-ZS User Instructions

Review Questions Photosynthesis

CS 325 Computer Graphics

CPI Links Content Guide & Five Items Resource

VMobile Desktop Talk User Guide

1. At which temperature would a source radiate the least amount of electromagnetic energy? 1) 273 K 3) 32 K 2) 212 K 4) 5 K

Separation and Identification of Plant Pigments Dr. Gergens - SD Mesa College

Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab

Call Center - Agent Application User Manual

3. USB DRIVER Installation of USB driver Driver for Infinity SD Data Logger. INFINITY Series Acquisition Tools Manual

Macs are not directly compatible with Noetix.

Jackson Systems E-commerce Guide

Renewable Energy Monitor User Manual And Software Reference Guide. (979)

Light Waves and Matter

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.

Use of Micropipettes

DSM155 Digital LED Light Meter User s Manual DSM155

Energy Pathways in Earth s Atmosphere

Luminol Test PROCESS SKILLS SCIENCE TOPICS VOCABULARY

TO INVESTIGATE THE PROTECTION OF SUNCREAMS AGAINST UV RAYS

THE EFFECT OF COLOUR FILTERS ON SOLAR PANELS. Katie Fitzgerald Expo Project Grade 7

GENERAL SCIENCE LABORATORY 1110L Lab Experiment 6: Ohm s Law

Studying Photosynthetic Electron Transport through the Hill Reaction

STAAR Science Tutorial 30 TEK 8.8C: Electromagnetic Waves

LinQ Mobile Software User s Guide

Introduction to Infrared Thermography. Jeff Beard IT 570

Chemistry 118 Laboratory University of Massachusetts Boston Beer s Law

Service Desk. (Ver.Oct.2012)

GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G

Inking in MS Office 2013

Select Correct USB Driver

Colorimetric Determination of Iron in Vitamin Tablets

F re Alarm Network etwo (FAN) T rou rou h Virt Vi ual u Private Network etwo (VPN) Dr. Dr Sa S mir H. Abdull--Ja J u a wad

Transcription:

1 Experiment C-31 Color Absorption Objectives To understand the concepts of light waves and color. To investigate how red, green and blue liquids absorb light of different wavelengths. To learn about colorimeter applications. Modules and Sensors PC + NeuLog application USB-200 module NUL-219 Colorimeter logger sensor Equipment and Accessories 50 ml beaker 3 Plastic cuvette (included with 3 the sensor) The items above (except for the cuvette) are included in the NeuLog Utility accessories, UTL-KIT. Materials 20 ml of red food coloring (1:40 dilution) 20 ml of green food coloring (1:40 dilution) 20 ml of blue food coloring (1:40 dilution)

2 Introduction In order to understand color concepts, it is first necessary to understand light concepts. Visible light waves are seen by the human eye as different colors and they are characterized by their wavelength, which is the distance between any two corresponding points on successive waves. The length of the wave determines the amount of energy it has; the shorter the wavelength, the higher the energy. Color may be also defined in more subjective terms, as something perceived by an individual. When light is reflected from an object, cones and rods in the retina of the eye respond to the light and the brain interprets the information received as color. Light can be directly absorbed by an object, reflected at the surface or transmitted through it. The electromagnetic spectrum which is visible to us is in the range of 400-700 nm. When visible light with an energy distribution similar to sunlight (light of all colors) completely reflects from an object, this light appears white to the human eye. When the object completely absorbs all the light, it is recognized as black. When we project light through a transparent colored liquid, some light is absorbed and some is transmitted (and reflected). A red liquid transmits mostly red light and absorbs the rest. This principle is used in colorimetry. Colorimetry is a procedure in which a solution is analyzed by passing selected wavelengths of light (in the visible range) through a solution and measuring the amount of light that is transmitted. Then the absorbed light can be calculated.

3 The quality (wavelengths) of the absorbed light depends on the molecule dissolved in the solvent. This may help to identify a solute. The quantity of the absorbed light depends on the concentration of the absorbing solute (see experiment C-28, Beer-Lambert law). This helps when you want to determine the concentration of a solute in a solution. In this experiment we will investigate the absorbance of red, green, and blue food coloring after irradiating light in red (640 nm), green (524 nm) and blue (470 nm) wavelengths. Procedure Experiment setup 1. Set up the experiment as shown in the picture below. 2. Make sure you have three 50 ml beakers, each containing 20 ml of diluted food coloring (red, green and blue). It is recommended to dilute the food coloring by 40 (depends on the initial concentration). Make sure you also have three cuvettes.

4 Sensor setup 3. Connect the USB-200 module to the PC. 4. Check that the colorimeter sensor is connected to the USB-200 module. Note: The following application functions are explained in short. It is recommended to practice the NeuLog application functions (as described in the user manual) beforehand. 5. Run the NeuLog application and check that the colorimeter sensor is identified.

5 Settings 6. Click on the On-line Experiment icon in the NeuLog main icon bar. 7. Click on the Sensor's Module box. 8. Click on the Range button. 9. Select the "Red Abs" button to change the sensor's mode to absorbance of red wavelengths. 10. This experiment is done in single step mode so the experiment duration and sample rate will not be set.

6 Testing and measurements 11. Pour the red food coloring into the cuvette so that it will fill a third of it. 12. Place the cuvette in the colorimeter and click on the Single Step icon wavelength. in order to measure absorbance in the red 13. Click on the Table icon on the bottom part of the screen. A table will be displayed for data record. 14. Change the "Manual values" column name to "Light/Liquid" (clicking on the title of the column will allow you to do so). 15. Fill the suitable name in the "Light/Liquid" column, for this measurement it will be "Red/Red".

16. Fill in the following table with your measurement: 7 Liquid Red food coloring Green food coloring Blue food coloring Red Light irradiated Green Blue 17. Click on the Erase Experiment icon. 18. Click on the sensor's Module box and change the irradiated light to green. 19. Repeat the measurement while filling the suitable name in the "Light/Liquid" column, for this measurement it will be "Green/Red". 20. Repeat the measurements according to table above.

8 21. This is an example of irradiating the red food coloring with red, green and blue light. We can see that the red liquid does not absorb any of the red light (A=0). However, it absorbs green and blue light (A=0.83 and A=0.69 respectively). Our results are compatible with the concepts discussed in the introduction. When we project light through a transparent colored liquid, some light is absorbed (the colors that we do not see) and the rest is transmitted and reflected (the colors that we do see).

9 Summary questions 1. Explain the results of the green and blue food coloring measurements. 2. If the liquids were more diluted, how would it affect the results? Explain. 3. What is the best light color (of the colorimeter) for determining the concentration of your red, green and blue food coloring? 4. According to your results, which wavelengths (in terms of colors) do you think chlorophylls use in photosynthesis?