To purchase a full bound copy of this document contact



Similar documents
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Unstirred Water Baths

Unstirred Water Baths

Instruction manual. VWR unstirred water baths

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

Shaking water bath OLS200 Refrigerated immersion cooler CS200G

TMS TANK MANAGEMENT SYSTEM

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Drayton Digistat +2RF/+3RF

SAGE SCIENCE INC. Pippin Prep IQ/OQ Rev. A Originated: March 5, Sheet 1 of 11. Prepared by: Alex Vira SUMMARY

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Elster Metering Systems. EC Directive 2004/22/EC

STD - STANDARD VERSION extended possibilities reasonable price wide range of optional equipment

Clifton Food Range Bath Choice Booklet

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Hot Water Urns. all models. Helpline. v3.0

Contact Details. Please note that some of the contact details on this PDF document may not be current.

WATER BATH. Art. No /115/1400 (115 V) 35097/230/1400 (230 V) OPERATING INSTRUCTIONS. User information: Water bath Teflon mesh

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

804 Ti Stand. Manual EN

Current Monitoring Kit

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

CYMAQ Marking System AS200 + DS7050 N-14

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

Platelet Incubator Operation Manual

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Installation and Operation Back-UPS 1250, 1300, 1500

2-SLICE COOL TOUCH TOASTER

WSD130 SOLDERING STATION

Installation and Operational Qualification Protocol (Reference: SOP )

Pocket Tach 99 (PT99) Non-Contact Tachometer

TIG INVERTER INSTRUCTION MANUAL

T0118 T2118 T3118. Instruction Manual

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

TORKEL 820 Battery Load Unit

Manual Ranging MultiMeter

STERILIZERS, LABORATORY DRYING OVENS

User manual Insulation Resistance Tester

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

PD 100A. Printing data system

User Guide. Main Heat Condensing Central Heating Boiler

Current Monitoring Kit QUICK START GUIDE

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Problem / Solution. The problem:

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

Digi-Mantle A Reaction Station with Interchangeable Mantles.

Shaking Water Baths THERMOLAB

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

User Guide. Promax System Condensing System Boiler

User Guide. Temperature and Humidity Datalogger. Model 42280

USER S MANUAL HSC-24A

Operating instructions Platform/floor scales

Hand-held thermometer Model CTH7000

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

2-Stage, 3-phase controller Type 30051/

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Handheld portable appliance testers

Qualification of temperature-controlled storage areas

Operations Manual Blast Chiller

User manual. 086U6297 Rev. 9 EN

1. SAFETY INFORMATION

Single Station Remote Alarm

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Installation & User Instructions

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Please read operating instructions carefully before use and keep for further reference.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Agilent Cary 60 UV-Vis

Processor. User Guide

Instructions for Safe Use

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

DC Electronic Loads 8500 series

OPERATIONAL STANDARD

My home Mobile phone application

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

TC-9102 Series Surface Mount Temperature Controllers

Druck PV 62x pneumatic/hydraulic pressure stations

Refrigerated Air Dryers. Catalogue

Controls for fan coil units and cassettes

Installation and maintenance instructions. Danfoss Vent

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

Bosch Temperature Controllers Operation HANDBOOK

Michelin User Guide. Hi-power Rapid Tyre Inflator

MOUNTING AND OPERATING INSTRUCTIONS

Please read the operating instructions carefully to familiarize yourself with the features and modes of operation before using the instrument.

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

Paint Test Equipment. Holitech DC Holiday Tester Data Sheet

Microwave Meter. Instruction Manual

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

FIREDEX Conventional Fire Panels

Split Controller. User Manual SM-SS-F 2009/01/04

Thermistor Thermometer MODEL NO

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

Transcription:

29570 SUB Aqua Plus IQOQ document Unique Product Serial number label placed here To purchase a full bound copy of this document contact Grant Instruments (Cambridge) Ltd Shepreth Cambridgeshire SG8 6GB England Tel: +44 (0) 1763 260811 Fax: +44 (0) 1763 262410 Email: service@grant.co.uk www.grant.co.uk

Contents Installation Qualification Instrument Origin and Identification... 2 Instrument Specification... 3 Environment and Siting... 4 Instrument Delivery and Documentation... 5 Instrument Safety... 6 Assembly and Installation... 7 Summary Report... 8 Operational Qualification Safety Tests... 9 Pre-Run Checks... 10 Functional Tests... 11 Calibration... 12 Training... 13 Summary Report... 14 Installation and Operational Qualification 1

Instrument Origin and Identification Installation Qualification Instrument Series: Unstirred Water Bath Model: SUB Aqua Plus Instrument Description: Digital thermostatic unstirred water bath Manufacturer: Grant Instruments (Cambridge) Ltd Shepreth Cambridgeshire SG8 6GB England http://www.grant.co.uk Service Contact: Tel: +44 (0) 1763 260811 Fax: +44 (0) 1763 262410 E-mail: service@grant.co.uk Serial Number: Condition When Received: Date Received: New Used Reconditioned Installed Location: Purchase Order Number: Identification / Asset Number: Installation and Operational Qualification 2

Installation Qualification Instrument Specification Instrument Parameter Specified Range Acceptable Output Temperature 5 o C above ambient to 99 o C Temperature Stability at 37 C ± 0.2 o C Temperature Setting Resolution 0.1 o C Over Temperature Cut-Out Fixed (thermal fuse) and adjustable (user-defined sample protection) Bath Fluids Water only Bath Capacity SUB Aqua 2 Plus 2 litre SUB Aqua 2S Plus 2 litre SUB Aqua 5 Plus 5 litre SUB Aqua 12 Plus 12 litre SUB Aqua 18 Plus 18 litre SUB Aqua 26 Plus 26 litre SUB Aqua Dual Plus 5 &12L SUB Aqua 34 Plus 34 litre Comments: Installation and Operational Qualification 3

Installation Qualification Environment and Siting Has the instrument been adequately acclimatised since transport or storage? Yes No (refer to OM1.2*) * OMX denotes section X of the Operator Manual (also known as Operating Instructions) Operating Parameters Specified Range Conditions Met Ambient Temperature 5 40 o C Maximum Relative Humidity 80% up to 31 o C, decreasing linearly to 50% at 40 o C Maximum Altitude 2,000 m (6,500 ft) Supply Voltage & Frequency 230V@ 50/60Hz or 120V@ 50/60Hz Model 230V 110V Current Rating (Amps) Comments: SUB Aqua 2 Plus 1.0 0.5 SUB Aqua 2S Plus 2.6 1.3 SUB Aqua 5 Plus 2.6 1.3 SUB Aqua12 Plus 5.3 2.7 SUB Aqua18 Plus 7.9 5.3 SUB Aqua 26 Plus 7.9 5.3 SUB Aqua Dual Plus 7.9 4.0 SUB Aqua 34 Plus 13.4 8.8 Installation and Operational Qualification 4

Installation Qualification Instrument Delivery and Documentation Unpack the instrument carefully. Are any items missing against the Packing List? Yes No If yes, state missing items: Is there any damage to the instrument or accessories? Yes No If yes: Description of damage: Corrective action: Manufacturer informed: Yes No Is all standard documentation included? Present Missing Operator Manual (OM) Certificate of Conformity Quick Start Guide Warranty Card (UK only) Is all additional documentation included? Present Requested Missing Not Requested Calibration Certificate Service Manual (SM) Performance Qualification (PQ) Installation and Operational Qualification 5

Installation Qualification Instrument Safety Manufacturer s Safety Recommendations: Allow enough space for the instrument Position on level, non-combustible surface indoors Area free from aggressive / explosive chemical mixtures Ensure correct power supply and all power switches easily accessible Beware hot surfaces and hot water both during and after use For 18 and 26 litre baths, empty the bath before moving it Do not use to heat material that could cause fire or other hazard Use safety goggles during high temperature operation Read Operator Manual before use Comments: Installation and Operational Qualification 6

Installation Qualification Assembly and Installation Assembled and Installed By: User Specialised Engineer Installation Procedure: OK Discrepancy N / A Unpack and retain packaging (OM4.1) Assembly (OM4.2) Site and connect to power supply (OM4.3, 4.4) Bath fluid filled correctly (OM5.1.1) Base tray fitted (OM5.1.3) Comments (including discrepancies): Installation and Operational Qualification 7

Installation Qualification Serial Number: Summary Report Instrument: Manufacturer: Grant Instruments Assessment of Complete Installation Qualification: No Deviations Deviations (list below) Deviation Impact on Operation Justification for Acceptance Successful completion of the preceding activities and checks indicates that this instrument has been satisfactorily delivered and installed. The instrument has passed the Installation Qualification procedure and may now be submitted for Operational Qualification. IQ Completed By: Date: Deviations Approved By: Date: IQ Approved By: Date: Installation and Operational Qualification 8

Operational Qualification Safety Tests This instrument conforms to the following standards and is supplied fully tested by the manufacturer: BS EN 61326:2006 Electrical equipment for measurement, control and laboratory use EMC requirements. BS EN 61010 Part 2-010:2003 Safety requirements for electrical equipment for measurement, control and laboratory use particular requirements for laboratory equipment for the heating of material. The following electrical safety tests should also be carried out by a competent person after installation. Safety Test Refer to Pass Fail Date Signed Earth Bonding OM9.2.3 Insulation Resistance OM9.2.3 Comments: Installation and Operational Qualification 9

Operational Qualification Pre-Run Checks Pre-Run Check Refer to OK Discrepancy N / A Bath fluid filled correctly OM5.1.1 Lid / polypropylene spheres in place OM5.1.2 Base tray fitted OM5.1.3 All power switches easily accessible OM4.3 Comments (including discrepancies): Installation and Operational Qualification 10

Operational Qualification Functional Tests Functional Test Refer to Acceptance Criteria Pass Fail Powers up - 1. Display illuminates and shows fluid temperature Heats fluid to reach set-point temperature OM5.3.2 1. Display shows fluid temperature increase and rising bar Controls fluid temperature when set-point reached OM5.3.2 1. Display shows fluid temperature at set-point and rising bar disappears Controls fluid temperature when sample protection thermostat level reached (Test by setting sample protection thermostat slightly lower than set-point temperature. Remember to reset sample protection thermostat back above set-point afterwards) OM5.3.3 1. Display alternates between fluid temperature and and audible alarm sounds. 2. Fluid held just above sample protection temperature with greater fluctuation Water heats to the preset tempearture OM5.3.4 OM5.3.5 1. Display shows 'then preset temperature when Preset Key 1 is pressed 2. Water reaches preset temp Countdown timer Comments: OM5.3.6 1. Dot will flash on the display. 2. Alarm sounds at the end of countdown period 3. Alarm stops when enter is pressed Installation and Operational Qualification 11

Operational Qualification Calibration This instrument is supplied fully calibrated by the manufacturer, using equipment traceable to national standards. Calibration by the user directly following standard installation is not usually required. Calibration Step Refer to OK Not Done Single Point Calibration OM5.3.9 Twin Point Calibration OM5.3.10 Traceable Reference Thermometer Serial Number: Comments: Installation and Operational Qualification 12

Operational Qualification Training Date Instrument Released for Use: Trained Operators Read Operator Manual Practical Training Authorising Signature Comments: Installation and Operational Qualification 13

Operational Qualification Serial Number: Summary Report Instrument: Manufacturer: Grant Instruments Assessment of Complete Operational Qualification: No Deviations Deviations (list below) Deviation Impact on Operation Justification for Acceptance Successful completion of the preceding activities and checks indicates that this instrument is operating satisfactorily following delivery and installation. The instrument has passed the Operational Qualification procedure and may now be released for use. OQ Completed By: Date: Deviations Approved By: Date: OQ Approved By: Date: Installation and Operational Qualification 14