Noise Control Solutions for Floors, Walls, Ceilings, and Structures

Similar documents
Controlling the Transmission of Impact Sound through Floors

Lightweight Partition Design for Residential and Commercial Buildings

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

HOME THEATER. Noise Isolation, Soundproofing & Accessories

Mass Loaded Vinyl A review of the performance and cost in acoustical applications

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No.

Additions and Alterations

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

H-Stud Area Separation Wall System

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Color logos Reverse logos Acoustics Black only logos

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

The Case for Cross Laminated Timber: Part 2

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

The Role of Acoustics in Curtain Wall Design:

R-Value and Densities Chart

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Acoustic performance of dwellings and specifics for lightweight constructions Professor Eddy Gerretsen

Renovating Your Basement

CertainTeed. Shaftliner For A rea Separation Firewalls

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

PART 1 GENERAL 1.1 SECTION INCLUDES

Cement Board Exterior Applications Guide

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

B. Related categories: The following categories contain requirements that relate to this section:

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Gypsum Board Systems Manual

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

Fire Protective Options for I-Joist Floor Systems CONSTRUCTION GUIDE

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Installation Guide. Bath and Wall Surrounds SERIES B

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

How To Repair A Boat Landing Deck With A Boat Bed

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Fiberglas, Exterior Wall Thermal Insulation

Underwriters Laboratories Testing Information

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Point Auditorium Design Narrative PROJECT NAME: Point Auditorium DATE: 06/25/15 TO: Lance Francis FROM: Leslie Ellsworth

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

PANELIZED HOME INSTALLATION GUIDELINE

Vibration Isolation in Data Centers

EcoTouch Insulation with PureFiber Technology

GYPSUM AREA SEPARATION FIREWALLS GA

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

GYPSUM BOARD AND PLASTER

Mark Cramer Inspection Services, Inc.

Rockwool Flexi Insulation Application Guide

TECHNICAL ASSESSMENT:

Chapter 6 ROOF-CEILING SYSTEMS

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

Design No. P736 September 26, Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A)

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

MOLD AND MOISTURE RESISTANT PAPERLESS SOLUTIONS FOR AREA SEPARATION WALLS

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Wood-frame Construction, Fire Resistance and Sound Transmission

Composite Panel Firewall Systems

SECTION PIPE HANGERS AND SUPPORTS

Retrofit structural insulated panels (SIPs) increase sound transmission loss of existing single family houses impacted by highway noise

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

sound reduction systems for commercial, educational and industrial environments

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

FIRE-RESISTANCE RATINGS WITH STEEL JOISTS

CHAPTER 7: Building Systems ROOFING SYSTEMS

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

Comprehensive information on fire-rated assemblies incorporating USG products and systems. Fire-Resistant. Assemblies

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

MRI RF SHIELDING DESIGN

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

Engineered Wood Foundations

Technical Data wedi Subliner Dry Waterproofing Shower and Wet Area System

Insulation R-Value Comparisons

WEBSTER ELEMENTARY SCHOOL New Rochelle, New York Evaluation of Collapsed Ceiling Room 204

DUROCK Brand Cement Board. installation guide. Substrate and ceramic tile installation for walls, floors, countertops and wall shields.

COMMONLY USED RESIDENTIAL BUILDING CODES

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

4 Installation Requirements

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Controlling sound to make buildings more functional, productive and comfortable. Acoustical Assemblies

How To Install Hardwood Flooring

AUTHORIZATION TO MARK

ULTIMATE GUIDE BE PREPARED FOR YOUR UPCOMING PROJECT

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

Annex of the certificate (Page 1/6) Accreditation Scope

Best Basement Water Management Practices

Transcription:

Noise Control Solutions for Floors, Walls, Ceilings, and Structures

CREATE QUIET IsoMax: Resilient Sound Isolation Wall and Ceiling Clip Patent No. 7,093,814 Effective sound control at low installed cost Error free installation of standard drywall furring channel Low-profile design; maximizes available occupied space Best performance for the fewest dollars spent to build noise control ceilings and walls Exclusive UL design L583 offers 1-hour fire rating for typical wood-framed ceiling composites Sound Damp2 Add to second layer of drywall for improved Great for renovations Tested up to 53 Easy to apply Water Cleanup 2x4 Wood Stud Fiberglass Insulation KINETICS TM IsoMax Clips 7/8" 57 without Sound Damp2 39 with Sound Damp2 50 +11 2 Layers of 2x4 Wood Stud Fiberglass Insulation KINETICS TM IsoMax Clips 7/8" 2 Layers of 2 Layers of 1-5/8" x 3-5/8" Steel Stud Fiberglass Insulation KINETICS TM IsoMax Clips 7/8" 2 Layers of 64 RYWALL 2" x 4" Wood Stud Wall Studs 16" on Center Fiberglass Insulation (2) Layers 2" x 4" Wood Stud Wall Studs 24" on Center Sound Damp2 by Kinetics Noise Control (one side) Fiberglass Insulation (2) Layers

EILINGS 61 CERAMIC TILE 56 ESR-3207 WAVE Hanger Worldwide Patents Pending Quick and Easy Wood-Framed Installations Don t design mixed use or multi-family projects without KINETICS TM WAVE Hanger! Outperforms resilient channel and sound clips Highest performance-to-cost value for wood-framed floor/ceilings Fast and simple - No more pinching furring channel into clips! 7.88 in (200 mm) Fasteners Included 1.5 in (38 mm) Under Design Load ISPL Improvement vs. Resilient Channel ISPL Improvement (db) 16 14 12 10 8 6 4 2 WAVE ISPL Improvement above RC Deluxe Ceramic Tile 0 125 250 500 1000 2000 4000 WAVE Hanger 0.44 in (11 mm) Under Design Load 7/8" Frequency (Hz) Find your representative: www.kineticsnoise.com/arch/rep/ E-Mail: archsales@kineticsnoise.com Page 3

CREATE QUIET Concrete and Wood-Framed Ceiling Isolation Systems ICC: Deck-Suspended Ceiling Hanger Maximum natural frequency of 4.4 Hz under lightest typical load conditions Multiple features incorporated into the design ensure inexpensive installation; eliminates tying wire Spring/neoprene cup combination improves performance against low-frequency noise 4" Concrete Slab 1/2" Plywood 2" KINETICS TM RIM-Q-2-16 KINETICS TM ICC Isolation Hanger 3-1/2" Fiberglass Insulation KINETICS TM ICC Isolation Hanger 3-1/2" Fiberglass Insulation 94 84 82 70 THE ULTIMATE SOLUTION Contact your local sales rep for wire-tie and other hanger options KINETICS TM KSCH Ceiling Hanger Rock Wool Batts 72 51 IsoGrid: Quick-Connect Ceiling Hanger KINETICS TM IsoGrid Ceiling Hanger 6" Airspace Filled w/ Insulation 50 Dramatic labor savings over conventional ceiling hangers Meet code requirements while maximizing ceiling height Various attachment methods allow for installation on a variety of ceiling structures Known deflection rates ensure performance under design loads KSCH: Super-Compact Ceiling Hanger Patent No. 7,028,432 Low ~4" airspace using 7/8" drywall furring channel with full 1-inch spring deflection; Multiple mounting options Meets building code for / 50 in smallest possible space

EILINGS 5/16" Parquet Flooring 5/8" Plywood 2 x 10 Joists KINETICS TM ICW Ceiling Hanger 3-1/2" Fiberglass Insulation Hardwood Floor Over Vapor Barrier Mat 1-1/4" AccuCrete Slab 3/8" AccuQuiet Underlayment 3/4" Plywood 2 Layers Existing 1" x 6" Wood Subfloor 2x10 Joists 16" OC KINETICS TM ICW Ceiling Hanger 6" Fiberglass Insulation 3/8" Wood Floor 1-1/2" Concrete Slab 3/4" Plywood 2 x 10 Joists KINETICS TM ICW Ceiling Hanger 3-1/2" Fiberglass Insulation 59 F 57 76 52 F 62 ICW: Wood-Framed Ceiling Hanger 62 (UL Design 581) Exclusive UL design L581 offers 1-hour fire rating for typical wood-framed ceiling composites (UL Design 581) (UL Design 581) Maxium natural frequency of 4.4Hz under lightest typical loads Actual installed load can vary between 75% and 150% of rated load without significant impact to ceiling performance Superior noise control for wood-framed construction without floor underlayment Ideal solution for new-build and renovations Find your representative: www.kineticsnoise.com/arch/rep/ E-Mail: archsales@kineticsnoise.com Page 5

CREATE QUIET Concrete Floating Floor Systems 2" Topping Slab Precast Concrete 14" Tee 54 24 4" Concrete Slab 1/2" Plywood 2" KINETICS TM RIM L-2-12 2" Topping Slab Precast Concrete 14" Tee 73 70 4" Concrete Structural Floor 6" Concrete Structural Floor 49 53 25 27 3" Lightweight Concrete (polished) 1/2" Plywood 2" KINETICS TM RIM L-2-16 3-1/2" Wood Deck Subfloor Steel Beam and Glue Lam Joist Support No Ceiling 4" Concrete Slab 1/2" Plywood 2" KINETICS TM RIM-Q-2-16 NNIC* 62 72 F 54 62 LOFT FIELD TEST RIM: Roll-Out Isolation Mat System Design for any load range Easy to create 1", 2", 3", and 4" airspaces 4" Concrete Slab 1/2" Plywood 2" KINETICS TM RIM-Q-2-16 KINETICS TM ICC Isolation Hanger 3-1/2" Fiberglass Insulation 94 82 THE ULTIMATE SOLUTION Fast, simple, inexpensive installation Installation and supervision available RIM System successfully installed for over 45 years Natural Frequency constant over a wide load range Slab cast-in-place with no lifting required; trades back on the job as soon as concrete cures *Normalized Noise Isolation Class, field test for airborne noise reduction

Wood Flooring 4" Concrete Slab KINETICS TM LSM Isolator 2" Air Space, Vented 6" Structural Slab LOORS F 72 4" Reinforced Concrete Slab KINETICS TM FLM Isolator w/ Neoprene Pad 2" Air Space 6" Structural Slab 4" Reinforced Concrete Slab KINETICS TM FLM Isolator w/ Model KIP Pad 2" Air Space 6" Structural Slab 4" Reinforced Concrete Slab KINETICS TM FLM Isolator w/ Neoprene Pad 4" Air Space 6" Structural Slab 69 69 71 61 Which is better? Ask for full report. 61 KSSM: Spring Formwork Isolation System Optimal placement of isolation system across low capacity structural floor designs Pre-loaded assemblies eliminate long wait to lift concrete slab Coordinate design directly with Kinetics at SD/DD Phase LSM: Spring Lift Slab Concrete Floating Floor System Proven effective for vibration mitigation of intense impact noises, in gyms, weight rooms, bowling alleys, and sensitive instrumentation spaces. Concrete floors only. In-field acoustical testing yielded results of F 72, F 61 for a vented floating floor. FLM: Neoprene/KIP Lift Slab Concrete Floating Floor System Various load capacities offered in either fiberglass or neoprene isolators Easy to adapt for wide range of air spaces Standard mounts available for 4" thick concrete slabs Low-cost adapters available for thicker concrete slabs Find your representative: www.kineticsnoise.com/arch/rep/ E-Mail: archsales@kineticsnoise.com Page 7

CREATE QUIET Low Profile Floating Floors and Continuous Underlayent Systems RIM: Roll-out Isolation Material Highest Performance for Demanding Applications 1" Oak Hardwood Floor 3" Subfloor F 15 Ideal for dance studios, loft style condominiums, music practice rooms, and other applications requiring high performance noise control. Surpasses performance of continuous underlayments due to the airspace and lower natural frequency created by KINETICS TM KIP isolators. 3/4" Oak Hardwood Floor 3/4" Sleepers 1-1/2" Gypsum Concrete 2 Layers 1/2" OSB 1" KINETICS TM RIM-L-1-16 1" Oak Hardwood Floor 3" Subfloor 3/8" Plywood 2 Layers 3/4" Plywood 2" KINETICS TM RIM-I-2-16 Add between 2 Layers 3/4" Plywood F 50 66 71 F 45 64 Soundmatt: Low Profile for All Finish Floor Types Economical and Effective Low cost continuous floor underlayment Low-profile underlayment for wood, tile, and carpet Fast, easy installation - no bonding required Ceramic Tile 1/2" Wonderboard 5/16" KINETICS TM Soundmatt Vinyl Floor Covering 1" Gypsum Concrete 5/16" KINETICS TM Soundmatt 3/4" Oriented Stand Board (OSB) 18" I-Joist 3" Mineral Fiber Batts Resilient Channel without Soundmatt 60 53 F 51 +18 F 33

LOORS Low-cost, recycled rubber ISOLayment QT: Lowest Profile for Wood Floors and Ceramic Tile noise control underlayment Extensively tested at the top labs in the USA Two (2) Styles: Flat (F) and Bumpy (B) in full rolls Engineered Wood KINETICS TM IsoLayment QT-F 4" Concrete Hambro 500D System 1 Layer 1/2" GWB on furring channel Ceramic Tile KINETICS TM IsoLayment QT-F 8" PT Slab 54 51 F 59 SR Floorboard: Sound Rated Floor System Withstands live loads up to 1000 psf Cuts easily using standard construciton knife Floor composites with finished tile flooring can be under two-inches (2") high Ceramic Tile 7/16" Glass Mesh Mortar Unit/Bond Coat 5/8" KINETICS TM SR Floorboard 8" Flexicore Precast Subfloor 5/8" Hardwood Floor 3/4" Plywood Subfloor 5/8" KINETICS TM SR Floorboard 7" Concrete Slab 59 59 +38 F 54 Ultra Quiet SR Floorboard: High Performance Sound Rated Floor System Find your representative: www.kineticsnoise.com/arch/rep/ E-Mail: archsales@kineticsnoise.com Same features as SR Floorboard with higher performance capabilities High resilience and sound absorption in a single layer Hardwood Floor with 1/8" Pad 1-1/4" Gypsum Concrete 1" KINETICS TM Ultra Quiet SR Floorboard 3/4" Plywood 14" I-Joist 6" Fiberglass Insulation Resilient Channel 2 Layers of No Resilient Channel 54 53 59 51 Approved for use with gypsum concrete, standard concrete, and built-up wood floors Page 9

Wall Isolation Wallmat: Resilient Partition Isolation Pad Easy to install pre-cut strips Field cut to length with a utility knife Continuous resilient support of the partition Engineered for a wide range of studwall loads Use for both top and bottom plate installation IsoBacker: Acoustical Fire Rated Outlet Backer Pad Pipe/Duct Lagging Barrier Model KNM-100ALQ PSB and UniBrace L Resilient Sway Braces When an isolated masonry or stud partition requires bracing to the adjacent vertical structure, this sway brace acoustically decouples the two walls. Composite material designed to reduce the sound transmission from ductwork, piping, and equipment housings by combining a fire-rated limp mass barrier with a decoupling quilted fiber glass lining. (KNM-100AL is available without the quilted fiberglass lining) Fire Rated Indoor or Outdoor Noise Barrier Material Barrier Overlap Tab for Fast, Noise-Tight Installation Underwriters Laboratories classified Maintains acoustical ratings per ASTM C 919 and ASTM E 497 Testing ALLS to UL 2 (ASTM E119) and UL 1479 (ASTM E814) Outstanding adhesion to outlet boxes and other substrates UL listed for metallic and non-metallic outlet boxes Insertion Loss Tested as a duct wrap over 2" fiberglass board (ASTM E1222-90) Frequency, Hz KNM-100ALQ 2 125 10 250 16 500 27 1000 35 Tested as a duct wrap directly over duct (ASTM E1222-90) Frequency, Hz KNM-100ALQ 3 125 6 250 7 500 18 CREATE QUIET 1000 24 2000 34 2000 27 4000 33 4000 28

NIBRACE UniBrace Quick and easy solutions to challenging isolation hurdles. Head of Wall Isolation Soffit Isolation Single L Double L Plumbing Isolation TV Isolation Single F Double F Find your representative: www.kineticsnoise.com/arch/rep/ E-Mail: archsales@kineticsnoise.com Page 11

Bringing you the largest selection of Acoustic, Noise Control, and Vibration Isolation Products Noise Control www.kineticsnoise.com/arch/ Room Acoustics www.kineticsnoise.com/interiors/ Vibration Isolation www.kineticsnoise.com/hvac/ Airflow Attenuation www.kineticsnoise.com/industrial/air_control.html Environmental www.kineticsnoise.com/industrial/environmental.html kineticsnoise.com/arch/ archsales@kineticsnoise.com 1-800-959-1229 Manufacturing facilities in Ohio, USA; California, USA; and Ontario, Canada. Sales offices worldwide. Kinetics Noise Control, Inc. is continually upgrading the quality of our products. We reserve the right to make changes to this and all products without notice. ARCH 9/14