Heavy Metal Analysis for the Toy Industry by Inductively Coupled Plasma Optical Emission Spectroscopy



Similar documents
UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

Universal Data Acquisition (UDA)

Determination of Metals in a 3% Sodium Chloride (NaCl) Matrix by Axially-Viewed ICP-OES

Elemental Analyses by ICP-AES

How To Use The Nexion 300

HS 1003 Part 2 HS 1003 Heavy Metals Test

NUTC R304. Use of Absorption Mechanisms to Decrease Heavy Metal Mobility

Accurate Determination of Lead in Different Dairy Products by Graphite Furnace Atomic Absorption Spectrometry

VALIDATION REPORT. Investigation of the major interferences for proposed Horizontal ICP AES method. ECN protocol

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

TEST REPORT Page 1 of 30

Secondary Lead Smelting

Certificate of Analysis

TEST REPORT Page 1 of 9 TEXTILE LABORATORY MANAGER

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

Potassium Aluminium Silicate (Mica) Chemical and Technical Assessment (CTA) Prepared by Daniel E. Folmer, Ph.D., and reviewed by Madduri V. Rao, Ph.D.

TEST REPORT Page 1 of 7

BRIEFING Plastic Packaging Systems for Pharmaceutical Use.

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT

DMA-1 Direct Mercury Analyzer

This example of a completed sampling plan worksheet has been included to illustrate the information

Analysis of Chlorine, Bromine and Iodine in Water using ICP-AES

TEST REPORT Job No./Report No TR Date:12 June 2014 Page 1 of 5

Regional Environmental Protection Agency- Veneto Region LABORATORY REGIONAL DEPARTMENT

MILESTONE H E L P I N G C H E M I S T S

Colorants for Plastics are our Playground PRODUCT STEWARDSHIP: ONE STEP AHEAD WITH CLARIANT

Modern approaches to determination of toxic metals in marine environmental objects. Atomic absorption and inductively coupled plasma, advantages and

DMA-80 Direct Mercury Analyzer

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

MILESTONE CLEAN CHEMISTRY LINE DUOPUR TRACECLEAN ULTRA-TRACE INSERTS. A Breakthrough in Reduction and Control of the Analytical Blank MILESTONE

ANALYTICAL REPORT LABORATORY DETAILS. Telephone Facsimile . SGS Reference Report Number Date Reported Date Received

One sample of Lineplus Powerline 2300 Highlighter (Orange-Blue-Yellow-Green-Pink) BUYER :

RoHS Test Methods. Presented by: Bruce Peterson

Determination of calcium by Standardized EDTA Solution

Work Assignment Prepared for: Office of Air Quality Planning and Standards U.S. Environmental Protection Agency Research Triangle Park, NC

Phosphorus, colorimetry, phosphomolybdate, automated-segmented flow

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

TEST REPORT Job No./Report No TR R1 Date:9 July 2014 Page 1 of 12

METHOD 6010B INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROMETRY

Guidance and Reporting Instructions on Temporary E-reporting for the MATS Rule

* TEST REPOR. TETAŞ Đç Ve Dış Ticaret A.Ş. Page 1 of 26 APPLICANT NAME

TEST REPORT Page 1 of 6. Birikim Elektronik San. Tic. Ltd. Şti. Battery Directive (2006/66/EC) was performed on the item.

A Visual Method for the Detection of Arsenic 0 to 500 µg/l By Dan Kroll R&D Chemist. Hach Co., Loveland Colorado

Rapid Thermophilic Digestion Technology

LED Life-Cycle Assessment & Environmental Testing

Standard Operation Procedure. Elemental Analysis of Solution samples with Inductively Coupled Plasma Mass Spectrometry

Laboratory Procedure Manual

OLIVÉR BÁNHIDI 1. Introduction

TEST REPORT Job No./Report No TR R1 Date:9 July 2014 Page 1 of 17

Determination of the Mass Percentage of Copper in a Penny. Introduction

Quantitation of Drugs in Dried Bloodstains. Thomas Meyer Anna Gomenyuk Nadiah Lester

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

ICP - Mass Spectrometry APPLICATION NOTE. Authors. Introduction. Lee Davidowski Ewa Pruszkowski PerkinElmer, Inc. Shelton, CT USA

CRITERIA DOCUMENTATION VERIFICATION PRINTED PAPER (Commission Decision 2012/481/EU)

DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech

TEST REPORT Job No./Report No TR Date:5 January 2015 Page 1 of 11

* TEST REPOR. TETAŞ Đç Ve Dış Ticaret A.Ş. Page 1 of 19 APPLICANT NAME

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Elemental Analysis Manual for Food and Related Products

The following merchandise was (were) submitted and identified by the client as : LAN CABLE LSZH 2006/01/ /01/05 TO 2006/01/19

SPIKE RECOVERY AND DETERMINING A METHOD DETECTION LIMIT Pamela Doolittle, University of Wisconsin Madison, pssemrad@wisc.edu 2014

All the prepared formulations were subjected for following. evaluation parameters and obtained results were showed in Tables 6.3 &

SCP SCIENCE Certified Reference Materials. Materials

NITRIC OXIDE and NITROGEN DIOXIDE 6014

A Beer s Law Experiment

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

XI. Methods of Analysis DETERMINATION OF POTASSIUM CARBONATE CALCULATIONS REAGENTS PROCEDURE

Umur Kırtasiye San. ve Tic. AŞ. Neslihan Sözer Chemical Laboratory Manager

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

SANTE ET HYGIENE INDUSTRIELLE Health Industrial hygiene Filtres, Peinture, Amiante, Silice Filters, Paint, Asbestos, Silica

TotalChrom. Chromatography Data Systems. Streamlining your laboratory workflow

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

Test Report No. F690101/LF-CTSAYAA

PACKAGING & MATERIALS TESTING SERVICES

METHOD DETERMINATION OF TRACE ELEMENTS IN WATERS AND WASTES BY INDUCTIVELY COUPLED PLASMA - MASS SPECTROMETRY. Revision 5.

Standard Operation Procedure. Elemental Analysis of Solution Samples with Inductively Coupled Plasma Optical Emission Spectrometry

ph Alkalinity of Water

Technical Information DF30

METHOD DETERMINATION OF METALS AND TRACE ELEMENTS IN WATER AND WASTES BY INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROMETRY

Standard Test Method for Analysis of Barium, Calcium, Magnesium, and Zinc in Unused Lubricating Oils by Atomic Absorption Spectrometry 1

limit to percentage levels, a limited working range translates

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM

Return to Lab Menu. Acids and Bases in Your House

SANEM MATBAACILIK VE ULUSLARARASI TAŞ A.Ş.

EXPERIMENT 4. Determination of Sodium by Flame Atomic-Emission Spectroscopy

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER , CAS NUMBER ] IRON ORE PELLETS

Determination of elements by ICP-AES and ICP-MS

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

ST. CLOUD TECHNICAL AND COMMUNITY COLLEGE HAZARDOUS WASTE PROCEDURE

Sample Analysis Design Isotope Dilution

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

TEST REPORT Page 1 of 6

EL724. Biodegradable Resin Products [EL /2/ ]

Transcription:

Heavy Metal Analysis for the Toy Industry by Inductively Coupled Plasma Optical Emission Spectroscopy In support of the toy industry, many laboratories are being called upon to analyze a wide variety of sample matrices for metal content. The primary element of interest is lead, but a number of other toxic elements pose a considerable threat, especially for children. This subset of elements, known as heavy metals, includes antimony, arsenic, barium, cadmium, chromium, selenium, mercury and lead as they are all known to accumulate in the body and cause detrimental effects over time. Some plastic and wooden toys, particularly those with painted surfaces have demonstrated elevated levels of Pb and other elements. Regulations exist which provide limits in materials for which surface contact with children can result in possible ingestion. Analysis of toys and other items of interest for heavy metal content is necessary to validate their manufacture, distribution and sale. Different regulating agencies provide elemental content limits for a variety of these sample types. The European Standard for safety of toys, EN 71, Part 3, which is adopted into ISO 8124-3, contains one section entitled Migration of certain elements. In this section it defines the limits of element migration from toy materials (see Table 1). In the U.S., the Food and Drug Administration (FDA) regulates the amount of lead and cadmium that can be leached from ceramic and other hollowware and flatware. As these items are designed to contain food, potential exposure to cadmium and lead must be limited. They specify an acetic acid leach procedure, similar to the hydrochloric acid leach specified in ISO 8124-3. Tables 2 and 3 list the limits detailed in these regulations. Further U.S. safety standards for toys are described by the Consumer Product Safety Council (CPSC) and listed in ASTM 936-07 including a reference to EN 71, Part 3. Lead in paint applied to toys is regulated in the Code of Federal Regulations (16 CFR 1303) which bans paint containing more than 0.06% lead in the dried paint film. The CPSC also bans any toys or articles intended for use by children that bear this lead-containing paint. These articles can also include any products that are used in or around the household or in recreation that may pose a risk to children of lead poisoning such as mini-blinds. Authors Lee Davidowski, PhD Zoe Grosser, PhD Laura Thompson PerkinElmer Life and Analytical Sciences 710 Bridgeport Avenue Shelton, CT 06484 USA ICP-OPTICAL EMISSION SPECTROSCOPY A P P L I C A T I O N N O T E

Table 1. Limits of Element Migration from Toy Materials (ISO 8124-3). Element Sb As Ba Cd Cr Pb Hg Se Maximum migrated Any toy material element in mg/kg given in clause 1 toy material except for: modelling clay 60 25 1000 75 60 90 60 500 Modelling clay 60 25 250 50 25 90 25 500 Table 2. Ceramic Leachable Lead Limits. Guidelines Category Criteria micrograms/ml Flatware average of 6 units 3.0 Small Hollowware other than cups and mugs any one of 6 units 2.0 Cups/mugs any one of 6 units 0.5 Large Hollowware other than pitchers any one of 6 units 1.0 Pitchers any one of 6 units 0.5 Table 3. Ceramic Leachable Cadmium Limits. Guidelines Category Criteria micrograms/ml Flatware average of 6 units 0.5 Small Hollowware any one of 6 units 0.5 Large Hollowware any one of 6 units 0.25 Although the actual analysis of these elements is not generally complicated, appropriate sample preparation can be challenging. It is important to evaluate the individual regulation requirement as it pertains to sample leaching or decomposition. To simulate the actions of the human digestion system, some sample preparation techniques utilize specific leaching procedures. Others require a complete and total acid decomposition of the sample to ensure a full content analysis. If the entire product is used in the extraction, contributions from the substrate or interior material in addition to the paint may be evaluated. Regulations may require paint scraping for evaluation of paint content only. It is important to understand the differences between wholeproduct versus paint-only sampling as well as between leaching and complete dissolution techniques. Following sample preparation, the measurement of elemental content can be carried out in any number of ways such as atomic absorption (AA), inductively coupled plasma-optical emission spectroscopy (ICP-OES) or inductively coupled plasma-mass spectrometry (ICP-MS). For this work, the ICP-OES technique was chosen as it provides both sufficient detection limits for the elements of interest and multielement capability with reasonable cost and experience requirements. The measurements were performed using the PerkinElmer Optima 5300 DV instrument. However, the details specified in this method can also be applied to the Optima 2100 DV instrument as well. Sample preparation A variety of matrices (Figures 1-3) were analyzed to show performance at the concentration levels of interest. Three different sample preparation methods were used to satisfy the various regulating agencies: Extraction U.S. method AOAC 973.32 4% acetic acid, 24 hours in darkness Extraction European method EN 71, Part 3 (ISO 8124-3) HCl for 2 hours at 37 C, darkness Complete paint digestion Microwave, Multiwave 3000, diluted to 50 ml 2

Figure 1. Toy car samples. The complete digestion was carried out using the Multiwave 3000 microwave digestion system equipped with the Rotor 8XF100. The Multiwave 3000 offers closed vessel technology which allows for complete digestion of difficult substances as well as consistent results. Approximately 100 mg of sample was weighed into the sample vessels to which was added 6 ml HNO 3 and 1 ml HCl. The digestion program used is listed in Table 4. After digestion, the samples were quantitatively transferred to sample vials and diluted to 50 ml with deionized water. Figure 2. Additional toy samples. For the two extraction methods, the paint was scraped off the toys and approximately 100 mg was weighed into a plastic 50 ml volumetric tube. To each tube, 10 ml of 4% acetic acid or 5 ml of 0.1 M HCl was added. For the acetic acid extractions, the tubes were allowed to sit overnight in darkness (up to 24 hours). The tubes containing the HCl extractant were heated in a water bath at 37 C in darkness for 1 hour with agitation. This was followed by 1 hour in the water bath in darkness without agitation. These extractions were then filtered through 0.45 µm membranes prior to analysis. Experimental Analysis of all sample digests and extractions was performed using an Optima 5300 DV ICP-OES equipped with a SeaSpray concentric nebulizer (Glass Expansion, Pocasset, MA) and cyclonic spray chamber. The instrumental parameters are presented in Table 5. The wavelengths chosen are shown as part of the element name in Table 6. Figure 4. The Multiwave 3000. Table 4. MW3000 Digestion Program. Power Ramp Hold Step (W) (minutes) (minutes) Fan 1 800 5 10 1 2 1100 10 15 1 3 _ 15 3 Figure 3. Toy train samples. 3

Results and discussion The U.S. extraction method using acetic acid and the European hydrochloric acid extraction were compared to see if the results were significantly different in the amount of lead and cadmium extracted and available for determination. Detection limits in solution (three times the standard deviation of the blank) are similar for the matrices and are listed in Table 6 for the acetic acid matrix. The results for a variety of toys are presented in Table 7. The amount in solution was back calculated to the solid material to provide a more accurate comparison. The results are similar in that the large amount of lead clearly exceeding the criteria for lead paint was identified (>600 mg/kg) by both methods. The HCl extraction does seem more aggressive as evidenced by generally larger lead values extracted from the samples. Table 5. ICP-OES Instrumental Conditions. Parameter RF Power Nebulizer Flow Auxiliary Flow Plasma Flow Sample Pump Flow Plasma Viewing Processing Mode Auto Integration Read Delay Rinse Replicates 3 Background Correction Spray Chamber Nebulizer Setting 1450 W 0.55 L/min 0.2 L/min 15.0 L/min 1.2 ml/min Axial Area 5 sec min-20 sec max 30 sec 30 sec one or two points Cyclonic SeaSpray The European hydrochloric acid extraction method is referenced as the method of choice for toys in ASTM standard 936-07. It was further explored for a variety of toys using the variability factors and comparing the limits listed in the method. Table 8 shows the results for the eight elements listed in the method. The shaded boxes show values that exceed the values specified in the standard (listed in the table footnote). The yellow car exceeds the limits for barium, chromium, and lead. Extractions present reproducibility problems (as seen in the variability factors for the HCl method) and do not often have reference materials certified for use in that manner. A complete digestion and analysis provides a more conservative result and can often be verified with a certified reference material. Two NIST paint reference materials were digested in duplicate using the Multiwave 3000 microwave digestion system with the same method as used for the toys and the eight elements of interest were measured. Table 9 shows the reference materials duplicate analyses and the recovery of the certified value. Paint scraped from a variety of toys was also digested using the microwave procedure and the eight elements measured. The results are shown in Table 10. Several elements are present and lead is clearly above the leaded paint limits in the yellow plastic car. Table 6. Calculated Detection Limits in Acetic Acid Matrix. Analyte Detection Limit (mg/l) Sb 217.582 0.001 As 188.979 0.007 Ba 233.527 0.003 Cd 228.802 0.0004 Cr 267.716 0.001 Pb 220.353 0.003 Hg 194.168 0.001 Se 196.026 0.011 Table 7. Comparison of Acetic Acid and HCl Leaching Procedures (mg/kg). Hydrochloric Acid Acetic Acid Extraction Extraction Lead Cadmium Lead Cadmium Orange Wooden Spoon < DL < DL < DL < DL Purple Wooden Spoon < DL 0.1 < DL 0.1 Red Wooden Spoon < DL < DL < DL < DL Pink Charm < DL < DL < DL < DL Blue Charm 0.1 < DL < DL < DL Purple Charm 0.1 < DL < DL < DL Red Wooden Car Puzzle Piece 0.3 < DL 0.4 < DL Yellow Wooden Car Puzzle Piece 0.4 < DL < DL < DL Yellow Plastic Car 2490 < DL 1115 < DL 4

Conclusion Hazardous element content in toys is an on-going concern. This paper has shown that ICP-OES can accurately measure a wide range of concentrations and elements. The suite of eight elements specified in the European method can be increased to cover additional elements in the same run if additional elements are regulated or for liability concerns. ICP-OES coupled with a digestion technique, such as microwave, can provide a fast turnaround so that waiting shipments can be evaluated as soon as possible for release. Table 8. HCl Extract Results for Eight Elements (mg/kg). Antimony Arsenic Barium Cadmium Chromium Lead Mercury Selenium Orange Wooden Spoon < DL < DL 51.2 < DL < DL < DL < DL < DL Purple Wooden Spoon < DL < DL 69.5 0.1 0.1 < DL < DL < DL Red Wooden Spoon < DL < DL 71 < DL < DL < DL < DL 0.002 Pink Charm < DL < DL 5.1 < DL 0.1 < DL < DL < DL Blue Charm < DL < DL 4.8 < DL < DL 0.1 < DL < DL Purple Charm < DL < DL 4.9 < DL < DL < DL < DL < DL Red Wooden Car Puzzle Piece < DL 0.6 568 < DL 1.1 0.2 < DL < DL Yellow Wooden Car Puzzle Piece < DL 0.3 666 < DL 1.0 0.3 < DL < DL Yellow Plastic Car 2.1 0.4 1020 < DL 383 1740 0.3 < DL Calculations based on total amount extracted and factor for variability as described in the method. Limits: Sb 60, As 25, Ba 1000, Cd 75, Cr 60, Pb 90, Hg 60, Se 500. < DL: less than the calculated detection limit. Table 9. NIST Standard Analysis. Pb in Solution (mg/l) Standard Deviation (SD) Pb in solid % Recovery NIST 1579a High Lead Paint-1 122.1 3.2 11.74% 97.8 NIST 1579a High Lead Paint-2 138.2 3.6 11.85% 98.8 NIST 2582 Low Lead Paint-1 0.287 0.002 214 mg/kg 103 NIST 2582 Low Lead Paint-2 0.222 0.006 197 mg/kg 94.2 Table 10. Total Digestion Results for Paint (mg/kg). Antimony Arsenic Barium Cadmium Chromium Lead Mercury Selenium Red Train Engine 1 < DL < DL < DL < DL < DL 573 < DL < DL Red Train Engine 2 < DL < DL < DL < DL < DL < DL < DL < DL Caboose < DL < DL 88 < DL < DL < DL < DL < DL Yellow Crossing Sign < DL < DL 66 < DL < DL < DL < DL < DL Red Wooden Car Puzzle Piece < DL 8 2350 < DL 5 < DL 5 < DL Yellow Wooden Car Puzzle Piece < DL < DL 3170 < DL 7 < DL < DL < DL Yellow Plastic Car 600 14 104 < DL 3400 14800 6.0 < DL NIST 1579a High Lead Paint < DL 45 2.7% 20 200 11.8% < DL < DL NIST 2582 Low Lead Paint < DL 11 1860 < DL 30 205 6.0 < DL 5

PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA Phone: (800) 762-4000 or (+1) 203-925-4602 For a complete listing of our global offices, visit /lasoffices 2007 PerkinElmer, Inc. All rights reserved. The PerkinElmer logo and design are registered trademarks of PerkinElmer, Inc. Multiwave and Optima are trademarks and PerkinElmer is a registered trademark of PerkinElmer, Inc. or its subsidiaries, in the United States and other countries. All other trademarks not owned by PerkinElmer, Inc. or its subsidiaries that are depicted herein are the property of their respective owners. PerkinElmer reserves the right to change this document at any time without notice and disclaims liability for editorial, pictorial or typographical errors. 008024_01 Printed in USA