16/20/22 kw. 16/20/22 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine



Similar documents
*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

8/11 kw. 8/11 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES

16/20/22 kw CENTURION SERIES

20 kw. 20 kw ISO. Synergy Variable Speed Residential Standby Generator Air-Cooled Gas Engine FEATURES

*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Diesel Engine Driven Generators Page 1 of 6

Frequently Asked Questions Generators

Magnum Mobile Generator MMG55 Specifications

Spark-ignited generator set

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

residential & commercial Generators

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Centro-Matic Automatic Lubrication Systems System Controls

C18 ACERT Fire Pump Tier bkw/ rpm

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

DIESEL GENERATOR SETS

Technical Specification. Generating Set with Waukesha engine burning natural gas

WHOLESALE DIRECT INC WEST 65TH STREET

ASCO SERIES 185 Power Transfer Switches

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

GTEC transfer switch open transition

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Diesel Generating Set

Giving You the Power to Stand Alone

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Oil and Coolant Circulating Heating System. Model - OCSM

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

How To Control A Power Command Powerplant

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

PM734F - Technical Data Sheet Winding 28

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

VLT Series 300 Watt True Sine Wave Inverter

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Distribution Dry Type Transformers

MAC-120HE-01 Air-Cooled Chiller

Explosion-Proof Electric Unit Heaters

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Generator DoCKInG StatIonS

New 27 hp 2 Cylinder Liquid-Cooled Engine

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Diesel Generator Set Model DFHC 60 Hz

FTQ. Daikin Inverter Ducted Heat Pump

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Diesel Generator Set Model DGDK 60 Hz

Thyristor-controlled power supplies and battery chargers

POWER GENERATION.

AZ420 MINIATURE GENERAL PURPOSE RELAY

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

It s storming outside. Neighbors have no power. For you, dinner s on in 15.

Continuous Power... Continuous Protection

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Model #: SMART2200CRMXL

CorePower Home Standby Generator

FTXS. Wall Mount Heat Pump or Cooling Only

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Annex-A TECHNICAL SPECIFICATION

Generator 101: Buying and Installing a Generator for Your Home or Office. bruniandcampisi.com

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Specifying a Variable Frequency Drive s

Secondary Unit Substations

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

Diesel Generator Set Model DFMB 60 Hz

Eaton s backup power systems. Mother nature strikes when you re least expecting it. Let Eaton be the solution for your backup power needs.

Transcription:

6/20/22 kw GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine 6/20/22 kw of 5 INCLUDES: True Power Electrical Technology Two Line LCD Multilingual Digital Evolution Controller (English/Spanish/ French/Portuguese) Two Transfer Switch Options Available: 00 Amp Pre-Wired Switch or 200 Amp Service Rated Switch. See Page 4 for Details. Electronic Governor External Main Circuit Breaker, System Status & Maintenance Interval LED Indicators GFCI Duplex Outlet Sound Attenuated Enclosure Flexible Fuel Line Connector Composite Mounting Pad Natural Gas or LP Gas Operation 5 Year Limited Warranty Capability to be installed within 8" (457 mm) of a building* Standby Power Rating s 006459-2, 00646-, 006462-2 (Steel - Bisque) - 6 kw 60 Hz 00672- (Aluminum - Gray) - 6 kw 60 Hz s 006729-2, 006730- (Steel - Bisque) - 20 kw 60 Hz s 00655-2, 006552- (Aluminum - Gray) - 22 kw 60 Hz Note: CUL certification only applies to unbundled units and units packaged with pre-wired switches. Units packaged with the Smart Switch are UL certified in the USA only. *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC S success in IMPROVING POWER BY DESIGN. But it doesn t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. TRUE POWER ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems. TEST CRITERIA: PROTOTYPE TESTED SYSTEM TORSIONAL TESTED NEMA MG-22 EVALUATION MOTOR STARTING ABILITY SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±%. SINGLE SOURCE SERVICE RESPONSE from Generac s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. TM *

6/20/22 kw 2 of 5 6/20/22 kw features and benefits Engine Generac (OHVI) design Quiet-Test Spiny-lok cast iron cylinder walls Electronic ignition/spark advance Full pressure lubrication system Low oil pressure shutdown system High temperature shutdown Maximizes engine breathing for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. Greatly reduces sound output and fuel consumption during bi-weekly exercise, compared to other brands. Rigid construction and added durability provide long engine life. These features combine to assure smooth, quick starting every time. Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. Shutdown protection prevents catastrophic engine damage due to low oil. Prevents damage due to overheating. Generator Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. Displaced phase excitation Maximizes motor starting capability. Automatic voltage regulation Regulates the output voltage to ±% prevents damaging voltage spikes. UL 2200 listed For your safety. Transfer Switch Fully automatic Pre-wired, color-coded conduits (Pre-wired switches only) Remote mounting Transfers your vital electrical loads to the energized source of power. Ensures the easiest, trouble-free installation. Mounts near your existing distribution panel for simple, low-cost installation. Evolution Controls Auto/Manual/Off illuminated buttons Two-line LCD multilingual display Sealed, raised buttons Utility voltage sensing Generator voltage sensing Selects the operating mode and provides easy, at-a-glance status indication in any condition. Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. Smooth, weather-resistant user interface for programming and operations. Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up, of standard voltage. Constantly monitors generator voltage to ensure the cleanest power delivered to the home. Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-500 seconds from the factory default setting of 5 seconds by a qualified dealer. Engine warm-up Engine cool-down Ensures engine is ready to assume the load, setpoint approximately 5 seconds. Allows engine to cool prior to shutdown, setpoint approximately minute. Programmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Smart battery charger Electronic governor Unit SAE weather protective enclosure Enclosed critical grade muffler Small, compact, attractive Installation System Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Maintains constant 60 Hz frequency. Sound attenuated enclosure ensures quiet operation and protection against mother nature, withstanding winds up to 50 mph. Hinged key locking roof panel for security. Lift-out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation, as close as 8" away from a building.* ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. Composite mounting pad Eliminates the need to pour a concrete pad unless required by local municipalities.

6/20/22 kw specifications Generator 006459-2, 00646-, 006729-2, 006730-, 00655-2, 006552-006462-2, 00672- (6 kw) (20 kw) (22 kw) Rated Maximum Continuous Power Capacity (LP) 6,000 Watts* 20,000 Watts* 22,000 Watts* Rated Maximum Continuous Power Capacity (NG) 6,000 Watts* 8,000 Watts* 9,500 Watts* Rated Voltage 240 240 240 Rated Maximum Continuous Load Current 240 Volts (LP/NG) 66.6/66.6 83.3/75 9.6/8.3 Total Harmonic Distortion Less than 5% Less than 5% Less than 5% Main Line Circuit Breaker 65 Amp 90 Amp 00 Amp Phase Number of Rotor Poles 2 2 2 Rated AC Frequency 60 Hz 60 Hz 60 Hz Power Factor.0.0.0 Battery Requirement (not included) Group 26R, 2 Volts and 525 CCA Minimum Unit Weight (lb/kg) 455/206.4 (Steel) 49/90 (Aluminum) 505/229 476/26 Dimensions (L x W x H) in/mm 48 x 25 x 29/28 x 638 x 732 Sound output in db(a) at 23 ft (7 m) with generator operating at normal load** 66 66 67 Sound output in db(a) at 23 ft (7 m) with generator in Quiet-Test low-speed exercise mode** 60 60 58 Exercise duration 5 min 5 min 5 min 6/20/22 kw 3 of 5 Engine Type of Engine GENERAC OHVI V-TWIN GENERAC OHVI V-TWIN GENERAC OHVI V-TWIN Number of Cylinders 2 2 2 Displacement 992 cc 999 cc 999 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/ Magneto Solid-state w/ Magneto Solid-state w/ Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5: 9.5: 9.5: Starter 2 Vdc 2 Vdc 2 Vdc Oil Capacity Including Filter Approx..9 qt/.8 L Approx..9 qt/.8 L Approx..9 qt/.8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas Liquid Propane ft³/hr (m³/hr) /2 Load Full Load ft 3 /hr (gal/hr) [l/hr] /2 Load Full Load 93 (5.47) 32 (8.83) 205 (5.8) 308 (8.72) 84 (5.2) 28 (7.96) 72.4 (.9) [7.2] 30 (3.9) [2.07] 75.6 (2.08) [7.87] 40 (3.85) [4.57] 83 (2.6) [8.6] 27 (3.68) [3.94] Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7" water column (7-3 mm mercury) for natural gas, 0-2" water column (9-22 mm mercury) for LP gas. For Btu content, multiply ft 3 /hr x 2500 (LP) or ft 3 /hr x 000 (NG). For Megajoule content, multiply m³/hr x 93.5 (LP) or m³/hr x 37.26 (NG) Controls 2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode Buttons: Auto Automatic Start on Utility failure. 7 day exerciser. Manual Start with starter control, unit stays on. If utility fails, transfer to load takes place. Off Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance Messages Engine Run Hours Indication Programmable start delay between 2-500 seconds (programmable by dealer only) Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting) From 40-7 V/90-26 V Future Set Capable Exerciser/Exercise Set Error Warning Run/Alarm/Maintenance Logs 50 Events Each Engine Start Sequence Cyclic cranking: 6 sec on, 7 rest (90 sec maximum duration). Starter Lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Charger Fault/Missing AC Warning Low Battery/Battery Problem Protection and Battery Condition Indication Automatic Voltage Regulation with Over and Under Voltage Protection Under-Frequency/Overload/Stepper Overcurrent Protection Safety Fused/Fuse Problem Protection Automatic Low Oil Pressure/High Oil Temperature Shutdown Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown High Engine Temperature Shutdown Internal Fault/Incorrect Wiring Protection Common External Fault Capability Field Upgradable Firmware **Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS554, ISO3046 and DIN627). * Maximum wattage and current are subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each,000 feet (304.8 meters) above sea level; and also will decrease about percent for each 6 C (0 F) above 6 C (60 F).

6/20/22 kw 4 of 5 6/20/22 kw switch options Pre-wired Features available on Steel 6 kw models only Electrically operated, mechanically-held contacts for fast, positive connections. Rated for all classes of load, 00% equipment rated, both inductive and resistive. 2 pole, 250 VAC contactors. 30 millisecond transfer time. Dual coil design. Main contacts are silver plated or silver alloy to resist welding and sticking. NEMA (indoor rated) enclosure is standard on the pre-wired switch. Multi listed for use with " standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effective install. Pre-wired 30 foot (9. meter) whip to connect to the provided 5 foot pre-wired whip and external connection box. Pre-wired 2 foot (0.6 meter) whip, color coded to connect into the existing electrical panel. 00646- (6 kw) No. of Poles 2 Current Rating (Amps) 00 Voltage Rating (VAC) 20/240, Ø Utility Voltage Monitor (Fixed)* -Pick-up 80% -Dropout 60% Return to Utility* approx. 5 sec. Exercise bi-weekly for 2 minutes* UL Listed Total of Pre-wired Circuits 6 No. 5 A 20 V 5 No. 20 A 20 V 5 No. 20 A 240 V No. 30 A 240 V - No. 40 A 240 V No. 50 A 240 V Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts 0,000 * Function of Evolution Controller Exercise can be set to weekly or monthly Dimensions Mechanical Dimensions Height Width H H2 W W2 Depth in 23.5 26.4 8.3 2.6 6.3 mm 597 67.7 2 320.7 59.6 H2 H Wire Ranges Conductor Lug Neutral Lug Ground Lug 2/0 - #4 2/0 - #4 2/0 - #4 W W2 Service Rated Switch Features Electrically operated, mechanically-held contacts for fast, clean connections. Rated for all classes of load, 00% equipment rated, both inductive and resistive. 2 pole, 250 VAC contactors. Service equipment rated, dual coil design. Rated for both aluminum and copper conductors. NEMA/UL 3R aluminum outdoor enclosure. Main contacts are silver plated or silver alloy to resist welding and sticking. 006462-2 (6 kw)/006729-2 (20 kw)/00655-2 (22 kw) No. of Poles 2 Current Rating (Amps) 200 Voltage Rating (VAC) 20/240, Ø Utility Voltage Monitor (Fixed)* -Pick-up -Dropout 80% 60% Return to Utility* approx. 3 sec. Exercise weekly for 2 minutes* UL Listed Enclosure Type NEMA/UL 3R Withstand Rating (Amps) 22,000 Lug Range 250 MCM - #6 *Function of Evolution Controller W Dimensions 200 Amps 20/240, ø Open Transition Service Rated Height Width H H2 W W2 Depth in 27.24 30.0.4 3.5 7.09 mm 692.0 762.4 289.0 343.0 80.0 DEPTH H2 W2 H

6/20/22 kw available accessories # Product Description 006463-3 Mobile Link Generac's Mobile Link allows you to check the status of your generator from anywhere that you have access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator s status occurs via e-mail or text message. Available in the U.S. only. 6/20/22 kw 00589-0 26R Wet Cell Battery 00622-0 Cold Weather Kit Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact). If the temperature regularly falls below 32 F (0 C), a cold weather kit is required to maintain optimal battery and oil temperatures. Kit consists of a battery warmer and oil filter heater with built-in thermostats. 5 of 5 00562-0 005839-0 - Bisque 005666-0 - Gray 005703-0 - Bisque 005704-0 - Gray 006484-0 - 6 kw 006485-0 - 20 & 22 kw Auxiliary Transfer Switch Contact Kit Fascia Base Wrap Kit* ( on 22 kw) Paint Kit* Scheduled Maintenance Kit The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you may not need. Not compatible with 50 amp pre-wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. 006664-0 Wireless Remote Monitor 006873-0 Smart Management Module (50 Amps) Completely wireless and battery powered, Generac's wireless remote monitor provides you with instant status information without ever leaving the house. Not compatible with CorePower or EcoGen systems. Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power management capabilities. It provides additional power management flexibility not found in any other power management system. * Note: Bisque kits are used in conjunction with steel enclosures. Gray kits are used in conjunction with aluminum enclosures. dimensions & UPCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 637.6 mm [25. in] 28 mm [47.9 in] 73.9 mm [28.8 in] UPC 006459-2 69647064599 00646-6964706462 00672-6964706727 006729-2 69647067293 006730-69647067309 00655-2 6964706550 006552-69647065527 006462-2 69647064629 642 mm [25.3 in] LEFT SIDE VIEW 226 mm [48.3 in] FRONT VIEW Generac Power Systems, Inc. S45 W29290 HWY. 59, Waukesha, WI 5389 generac.com 205 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0K8458-G Printed in U.S.A. 08/03/5