DEALER SERVICE BULLETIN



Similar documents
, User s Manual

COMPRESSOR REPLACEMENT PROCEDURE

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

*.ppt 11/2/ :48 PM 1

10 YEAR WARRANTY REGISTRATION PROCEDURES. Please see product warranty section in back of book for registration procedures

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

Infinity/ Evolution Troubleshooting Guide User Interface Software Ver. -03, -05, -06, -08, -10 and -12. Table of Contents

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

User s Information/Installation Instructions

Air Conditioning Systems Warranty Manual. Version 1.8

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

ECM. Service Guide.

Installation, Operation & Service Manual

Technical Information

Split System Cooling Product Data

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

Failure code manual. content

CONTROLS KITS AND ACCESSORIES /2014 Supersedes10/2014

COMPRESSOR REPLACEMENT PROCEDURE

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.


SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE

EXTENDED 10 YEAR LIMITED LIFETIME WARRANTY LIMITED LIFETIME WARRANTY

Features and Benefits. Product Overview. Installation Overview. Sales Strategy Overview FPO

Limited Warranty. BARD MANUFACTURING CO., INC. BRYAN, OHIO Dependable quality equipment... since 1914

HVAC Claims: Repair vs. Replacement

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Rotary Phase Converters

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

E2 Series Electric Furnaces

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Customized Assessment Blueprint

Split System Heat Pump Product Data

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Electric Motor Brake Horsepower Calculations

Split System Cooling Product Data

EET272 Worksheet Week 8

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Single Phase Soft Starter

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

Application Engineering

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

MP-4000 Alarm List (Software version or later)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

APPLICATION GUIDELINE & SERVICE MANUAL R 410A & R 22 Split System AC & HP

HEAT SIPHON ANSWERBOOK

Service and Maintenance. SEW-EURODRIVE Driving the world

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Residential electric heating and cooling rebates

Control of Hazardous Energy Equipment-Specific Lockout/Tagout Procedure (ELP) Template Instructions

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

Miami Heat Pump HP Series Installation Guide

OUTDOOR UNIT MODEL NUMBER IDENTIFICATION GUIDE (single phase) ACCESSORIES PART NUMBER IDENTIFICATION GUIDE

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

PANASONIC TROUBLE SHOOTING GUIDE

ARMSTRONG AIR HEAT PUMPS

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

Hoshizaki America, Inc.

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Fan Coil EC Motor Control

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

How To Warranty A Car From Nordyne

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Installation Instructions

Introduction. Motor Types

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Fusible Disconnect Switch

The Ultimate Truck Stock Motor

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Appliance Diagnostic Modes Microwave. GE Consumer & Industrial Technical Training

Generator Warranty On-Line System Documentation

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

INSTALLER S & OWNER S MANUAL

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

For Models #6-5001, #6-7501, # & #10-12K1

INSTALLER'S GUIDE. Supplementary Electric Heaters 18-GJ08D1-1. Table of Contents

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

Warranty Service Policy Guide For Manufactured Housing

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

HEAT HEAT COOL HEAT PUMP COOL

Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.

Dealer Sales & Service Guide

Extended Warranty Handbook

Air Conditioning Sign-Off Sheet

Why and How we Use Capacity Control

Transcription:

DEALER SERVICE BULLETIN Number: DSB 14-0025 Date: 4/1/14 Supersedes: DSB 11-0025A Revised 9/17/12 Title: Bristol Two Stage Compressor or Unit Replacement Program PRODUCT CATEGORY: Heat Pumps and Split System AC MODELS AFFECTED: Bryant: 698B, 598B, 286A, 187A Carrier: 38YDB, 38TDB, 25HNA6, 24ANA7 Serial Number(s): All serial numbers within 10 years of unit production date as indicated by the unit serial number. **Commercial installations are not eligible for the program.** SITUATION: This bulletin sets forth the modified replacement program for Bristol two stage compressors or complete outdoor units due to a compressor failure occurring on or after April 1 st, 2014 IF such failure occurs within 10 years of the unit production date. The Bristol two stage reciprocating compressor has undergone continuous improvements to extend its long term reliability, but is more sensitive to certain operating conditions than a scroll compressor. Oversized equipment, improper airflow and charging issues are a few examples of applications and operating conditions that can cause additional stress on the system s components, including the compressor. SOLUTION: All claims will be submitted directly into the Service Bench Warranty System by the distributor. The Bristol Audit Form must be signed by the homeowner and is required to be held indefinitely at distribution for potential factory audit. The customer has a choice of 2 options: Option 1: Compressor replacement without optional labor contract Carrier provides the replacement compressor and associated parts and pays a $200 dealer allowance for labor cost. The replacement compressor and associated parts assume the remainder of the standard limited warranty from the original unit installation date. Compressor replacement with optional labor contract Carrier pays a tiered optional contract labor and materials allowance for labor and miscellaneous parts (see Table #2 in Policy section below) in addition to providing the replacement compressor. The replacement compressor assumes the remainder of the standard limited warranty and the optional labor contract from the original unit installation date.

The following Bristol TS Compressor Part Numbers are covered under this bulletin. Prior to 2006 RCD part number Bristol model Mfg part number P032-2722K T89B284CBCA GB20PF007 P032-1926K T89B194CBCA GB20PF008 P032-3722K T89B385CBCA GB20TF004 P032-5121K T89A514BBCA GB20JF006 P032-5122K T89A514BBCA GB20JF008 2006 & After RCD part number Bristol model Mfg part number P032-1829K T81J195CBCA 757006-1000-00 P032-2723K T81J285CBCA 757007-1000-00 P032-3525K T81J384CBCA 757008-1000-00 P032-5221K T89A515BBCA 757009-1000-00 Option 2: Unit replacement without optional labor contract Customer pays a tiered unit replacement buy-in (see Table #1 below). Carrier has reduced the buy-in amount charged to the consumer by $450 to assist the consumer with installation costs. The consumer is responsible for negotiating labor and any additional charges. All such costs must be paid directly to the dealer by the consumer. Customer receives a new equivalent unit with a scroll compressor The new unit assumes the remainder of the original unit s limited warranty. Distributor is invoiced for customer pay in funds according to table #1. Unit replacement with optional labor contract Customer pays a tiered unit replacement buy-in (see Table #1 below). Carrier pays a tiered optional contract labor and materials allowance for labor and miscellaneous parts (see Table #2 in Policy section below). New equivalent unit with a scroll compressor The new unit assumes the remainder of the original unit s limited or optional warranty. Distributor is invoiced for customer pay in funds according to table #1.

TABLE #1 Tiered buy-in for unit based on TIS (Time In Service) > 36 but less than 72 Months TIS Less than 36 Months TIS > 72 to 120 Months TIS Unit Replacement Buy-In (With Optional Labor Contract) $0.00, Labor rate per Table # 2 in Policy Section $545.00, Labor rate per Table # 2 in Policy Section $1545.00, Labor rate per Table # 2 in Policy Section Unit Replacement Buy-In (Without Optional Labor Contract) $0.00, Carrier pays labor capped at $450 $545.00, Includes $450 reduction to help with installation costs. Customer pays labor costs to dealer $1545.00, Includes $450 reduction to help with installation costs. Customer pays labor costs to dealer The following table identifies indoor coil models that have an approved outdoor unit match and are therefore covered under this bulletin. Approved Match: Yes/No Approved Bristol Replacement 40FK (w/puron TXV) Yes Yes * FK4 (w/puron TXV) Yes Yes * FV4A, B Yes Yes * FV4C No Yes FE4A Yes Yes * Requires replacement of the indoor motor module for correct air flow when replacing the outdoor Bristol unit with the approved replacement model. Reference SMB 11-0024. The following table identifies approved outdoor models that have an approved outdoor unit match and are therefore covered under this bulletin. Only the equivalent replacement to the failed unit as identified in the below chart is approved under this bulletin. No upgrades are allowed. A change in unit size (tonnage) is allowable if appropriate for the installation as long as the replacement unit is listed in the Approved outdoor replacement chart below. Approved outdoor replacement units listed below: Carrier Bristol AC Approved A/C Replacement Model Approved A/C Replacement Model (Coastal) 38TDB024 24APA724A or 24ANB724A 24ANB724C 38TDB036 24APA736A or 24ANB736A 24ANB736C 38TDB037 24APA736A or 24ANB736A 24ANB736C 38TDB048 24APA748A or 24ANB748A 24ANB748C 38TDB060 24APA760A or 24ANB760A 24ANB760C 24ANA724 24APA724A or 24ANB724A 24ANB724C 24ANA736 24APA736A or 24ANB736A 24ANB736C 24ANA748 24APA748A or 24ANB748A 24ANB748C

24ANA760 24APA760A or 24ANB760A 24ANB760C Bristol HP Approved HP Replacement Model Approved HP Replacement Model (Coastal) 38YDB024 25HPA624A or 25HNB624A 25HNB624C 38YDB036 25HPA636A or 25HNB636A 25HNB636C 38YDB037 25HPA636A or 25HNB636A 25HNB636C 38YDB048 25HPA648A or 25HNB648A 25HNB648C 38YDB060 25HPA660A or 25HNB660A 25HNB660C 25HNA624 25HPA624A or 25HNB624A 25HNB624C 25HNA636 25HPA636A or 25HNB636A 25HNB636C 25HNA648 25HPA648A or 25HNB648A 25HNB648C 25HNA660 25HPA660A or 25HNB660A 25HNB660C Bryant Bristol AC Approved A/C Replacement Approved A/C Replacement Model Model (Coastal) 598BNX024 187BNA024 187BNC024 598BNX036 187BNA036 187BNC036 598BNX048 187BNA048 187BNC048 598BNX060 187BNA060 187BNC060 187ANA024 187BNA024 187BNC024 187ANA036 187BNA036 187BNC036 187ANA048 187BNA048 187BNC048 187ANA060 187BNA060 187BNC060 Bristol HP Approved HP Replacement Approved HP Replacement Model Model (Coastal) 698BNX024 286BNA024 286BNC024 698BNX036 286BNA036 286BNC036 698BNX048 286BNA048 286BNC048 698BNX060 286BNA060 286BNC060 286ANA024 286BNA024 286BNC024 286ANA036 286BNA036 286BNC036 286ANA048 286BNA048 286BNC048 286ANA060 286BNA060 286BNC060 * Replacement models listed are valid at time of original bulletin publishing. As models are replaced over time, the replacement model may be the listed model in this bulletin OR the equivalent newer model. ** Call Customer Service for pre-approval on any Coastal replacement models. A customer signature is required on the Bristol Program Audit form to ensure that the customer was presented ALL options under the terms of this bulletin. Claims missing the customer signature can be reversed.

Claiming: All claims should be filed by distributor. Field Action: Diagnose the failed unit using the attached procedure and Bristol Program Audit Form. Determine if unit is eligible for program by utilizing appendix B to determine if it is within 10 years of its production date. If unit is eligible, determine customer choice for unit replacement or compressor replacement. Provide the completed Bristol Program Audit Form with the customer s signature to your distributor service manager to obtain pre-approval for replacement under this program. For additional questions: Carrier Expert Central: Bryant Solution Center: 800-946-2930 admin.sams@carrier.utc.com 888-994-7237 admin.sams@carrier.utc.com Customer brochures are available to help explain the program and choices to the customer. They can be ordered under the following part numbers: Carrier: 01-811-20402-50 Bryant: 01-8110-1183-50 Parts: The following parts are approved for replacement under the terms of this bulletin when indicated: Contactor, Capacitor, Filter Drier, Start kit, Start Relay and Compressor Plug (Accumulator - not covered). Policy: All Bristol Compressor Claims must be filed under the terms of the SMB. Claims filed through standard warranty channels, including optional labor contracts, will be denied. This Policy will terminate June 30, 2014

Bristol Program Audit Form This form needs to be completed and submitted to your Distributor Service Manager for pre-authorization to replace the compressor or unit under -. All Fields Required System Information: Outdoor Unit Model / Serial Number: Compressor Model/Serial Number: Date Installed: Date Failed: Customers Name: Dealers Name: Distributors Name: Date: Customer Complaint: Compressor Capacity Loss? Does Unit Run? Below System Checks should be done in accordance to Appendix A of SMB 14-0025 Airflow: Was Airflow checked and is it within specification for the application? Is Static Pressure within specification? System Charge: Was system charge checked and was it within specification for the application? Is application a long line set? If YES above, have appropriate checks been done to ensure application/installation is correct for a long line set? Are there Buried Refrigerant Lines in the application? If Yes, has it been verified that no liquid slugging is occurring? Failed Compressor: Is there power to the compressor? Have the appropriate checks been done to determine that the issue is not electrical? Yes/ No / NA / NA Required: Customer was presented with all options under flyer 01-811-20402-50 or 01-8110-1183-50. For compressor replacement option, customer has received a $200 dealer allowance for labor costs. For unit replacement option, customer is responsible for dealer labor costs. Homeowner signature: Distributor Name & Service Manager Service Managers Signature Is the failed unit covered with an optional labor contract? no yes Contract #:

Appendix A: Bristol Compressor Program Diagnostic Reference These procedures outline the steps associated with diagnosing the compressor and filling out the program claim form. Please use this section as a reference when filling out the required claim form for the program. After review of this completed Bristol Compressor Evaluation Form the Distributor Service Manager is authorized to sign and approve a replacement outdoor unit or compressor replacement under the terms of this SMB. Proof of Compressor Electrical Failure (Defined as Compressor windings electrically open, shorted or winding resistance measurements not correct. If electrically open, the internal overload may be open and steps must be taken to determine if a problem external to the compressor is the cause of the overload trip.) Important Note: Prior to testing the compressor, disconnect and lockout/tagout all electrical power to system, including indoor and outdoor power sources. Terminal Locations for winding resistance readings Run winding Terminal R Terminal #3 Common Terminal C Start winding Terminal S Checking Compressor Winding Resistance Use the symbol for Open circuit The sum of the start and run winding resistances should be equal to the value measured between R and S. Resistance reading (R to C) + (S to C) = (R to S) if not, compressor winding is damaged If R to C and S to C are open circuit and R to S has resistance, the internal overload is open. The compressor needs time to cool to allow the internal overload to close. If the overload has opened, then other problems may be present in the refrigerant system that needs to be evaluated. Some possible causes of an open internal overload include insufficient refrigerant charge, restriction in the refrigerant circuit, and power supply problems. Replacing the unit may not solve these problems.

Checking the start Components Place a clamp amp meter between the start relay terminal 4 and the start capacitor. With the relay closed, you should observe amperage if the relay opens amperage should disappear. Measuring the voltage across the open relay terminals (SR 6 to SR4) if the relay terminals are closed voltage should be zero (0). When the relays open a voltages should be measured at a minimum the voltage should be line voltage. How the relay works Pl4 is a three (3) pin locking header with pin 2 removed. Header is labeled sr. The connections are: pl4-1 sr connection for the start relay pl4-2 not used pl4-3 sr ground return for the start relay Start relay output sr 85ma 22vdc On Bristol compressor models, when a command for compressor run occurs, the control will energize the start relay output, energizing the start relay (external to the board) that will add a start capacitor across the run capacitor of the compressor. When a predetermined voltage level at the appropriate terminal (vs. in high capacity and vr in low capacity) has been reached the relay removes the capacitor from the circuit.

On all models, the presence of voltage at both vr and vs is an indication that a contactor has closed and the compressor is starting or running. When starting or running, a phase difference of the voltages on the inputs will indicate the compressor internal thermal cutout is closed. If the phase difference is <= 5 degrees for 10 seconds, the internal cutout has opened and the compressor is no longer running. If an open thermal cutout has been detected, the control will de-energize the low or hi compressor outputs, but continue to energize the odf/pwm output for 15 minutes. The status (yellow) led will flash the appropriate code. If the control does not detect a model plug or detects an invalid model plug it will not allow the unit to operate. The status (yellow) led will flash the appropriate code. Compressor start detection on Bristol models only: In low stage, if the specified start voltage at vr terminal is not achieved, the start relay is de-energized after 1 second and the control will flash the appropriate fault code. In high stage, if the specified start voltage at vs terminal is not achieved, the start relay is de-energized after 1 second and the control will flash the appropriate fault code. If the specified start voltage is not achieved for 3 consecutive low stage starts, low stage operation is locked out for 30 minutes. If the specified start voltage is not achieved for 3 consecutive high stage starts, high stage operation is locked out for 30 minutes. The control will flash the appropriate fault code. Proof of Compressor Mechanical Failure (Defined as Compressor electrically correct, but either will not operate or will operate but not pump refrigerant or will only pump at low stage capacity when the high stage control and high stage contactor are calling for high stage) Noisy units DO NOT QUALIFY for Replacement unit coverage.) WARNING: this portion of the test procedure requires electrical power be supplied to the unit. Caution should be used to prevent personal injury due to electrical shock. Testing the Capacitor Capacitor MFD = 2654 X Amps / Volts

Appendix B: How to determine unit eligibility based on serial number Example Unit Serial Number: 3104XXXXXX (First 2 digits are calendar week, second 2 digits are calendar year) To qualify for this bulletin, the fail date for the compressor must be within 10 years of the production calendar week. Use the calendar below to determine if the compressor fail date falls on, or before, the production calendar week.