Desktop and Integrated Desktop Computer Product Environmental Information Declaration Form for COMMISSION REGULATION (EC) No 617/2013

Similar documents
Guide to ecodesign requirements for computers and computer servers. Are you a manufacturer or importer of computers and/or computer servers?

Product environmental attributes THE ECO DECLARATION

47000 SERIES - ELECTRONIC TRANSFORMERS

INFO. Legally binding regulations on relating to energy efficiency and environmental protection. Eco-Design Directive and EC-Commission Regulation

IdeaTab A1000L-F 60041,Z0A1 Issue date * Intended market * Global Europe Asia, Pacific & Japan Americas Other Additional information

Code of Conduct on Energy Efficiency of External Power Supplies

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

ThinkCentre M91/M91p Tower/SFF Model number * Tower: 7049, 4468, 4473,4476, 4479, 7052, 7053, 4495, 7136, 7178, 4497,

MAJORSINE Power Inverter

Product environmental attributes - IT Eco Declaration 2004

Handheld portable appliance testers

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

ENERGY STAR Program Requirements Product Specification for Computer Servers. Test Method Rev. Apr-2013

A project to optimise quality and energy efficiency must include metering

CANADIAN STANDARDS ASSOCIATION OPERATING AS CSA GROUP 178 REXDALE BOULEVARD TORONTO, ONTARIO M9W 1R3 CANADA

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Product environmental attributes THE ECO DECLARATION

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

ENERGY STAR Program Requirements Product Specification for Data Center Storage. Draft 2 Test Method March 2013

HP Port Switches Quick Setup Guide

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

LOXONE 12 Channel Amplifier

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Dock HP Pro Portable Tablet Dock. HP Quick Charge 18W AC Tablet Adapter. HP Duet Pen Refills. Cables HP Micro USB to USB Adapter

1. SAFETY INFORMATION

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

Peel Back Force Tester GPD s Peel Back Force Tester with FORCEWare software is being used to set peel back standards for the entire industry

Digital Clamp-on DMMs with uncompromising performance

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

7.5 Watt AC-DC Switch Power Supply

Chassis, Power Supply, and Element Management

Energy Communication Unit (ECU)

ST Series POWER SUPPLIES USER INSTRUCTIONS

HP Port and 48-Port Switches Quick Setup Guide

DC Electronic Loads 8500 series

Features, Benefits, and Operation

Understanding Power Factor, Crest Factor, and Surge Factor. White Paper #17

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Powerline 1200 User Manual

Applications. diris_826_a_1_gb_cat

Connecting your Victron product to a computer with VE Configure

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

GUIDE FOR TESTING POWER TRANSFORMERS

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

Operating Manual UWAPS-TINY Series

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

7-41 POWER FACTOR CORRECTION

EMC Test for Compliance with EU EMC Directive 2004/108/EU

OUTPUT CABLE CONNECTIONS:

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Polyphase kwh Electricity Meter

ENERGY-SAVINg DRIVE PACKAGE DE ES FR IT. Overview

Broadband Telecommunications Drop Amplifier

Integrating Sound Level Meter and Datalogger

Uninterruptible Power Supply

Energy Communication Unit (ECU)

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

GHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance. Chapter 7:

QuickSpecs. HP 480/277 Volt Solutions. Overview

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Voltage Regulator SPAU 341 C. Product Guide

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

Multi-Function Ground

Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy

Understanding Emergency Power Off (EPO)

Actuator-Sensor-Interface

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE Test Method for AC to DC Power Supplies

Cisco Nexus 7000 Series Power Supply Modules

Interactive Logging with FlukeView Forms

Installation and Operation Back-UPS 1250, 1300, 1500

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

650W Single Output Power Supply

Speed Control Relays SX2

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

SL Series AC and DC Electronic Loads

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Setting Up the Cisco IP Phone

White Paper Energy Consumption ESPRIMO E5731 E85+

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

hp digital home networking wireless USB network adapter hn210w quick start guide

Scout 1U Rackmount Computer

Transcription:

SUBJECT: Product Environmental Information Declaration DATE OF DECLARATION: 2015-03-23 Regulatory Reference: Product Type: Manufacturer s Name: Product Model Number: Commission Regulation (EU) No. 617/2013 of June 26, 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for computers and computer servers Desktop Computer Hewlett Packard Company 3000 Hanover Street Palo Alto, CA 94303-1112 United States of America HP Pavilion Mini 300 Desktop / HP Stream Mini 200 Desktop Year of Manufacture: 2015 Product Category: B Regulatory Model Number (RMN): TPC-P041-BX 1

Number 7.1.1 (e) & (f) E TEC value (kwh) and capability adjustments applied when all discrete graphics cards (dgfx) are disabled and if the system is tested with switchable graphics mode with UMA driving the display. Information Description (e1) PCs Configured with UMA Graphics: E TEC value (kwh) and capability adjustments applied when UMA graphics is on. TEC Cat. A (kwh)[1] TEC Cat. B (kwh)[1] 26.60 TEC Cat. C (kwh)[1] TEC Cat. D (kwh)[1] (e2) PCs Configured with Switchable Graphics: E TEC value (kwh) and capability adjustments applied when switchable graphics is enabled. Note: TEC With UMA Only (Discrete Disabled) or ETEC With Discrete Only (UMA Disabled) is Not Applicable. (f) PCs Configured with Discrete Graphics: E TEC value (kwh) and capability adjustments applied when Discrete Graphics is on. Not Applicable Not Applicable [1] Values shown in Kilowatt Hours (kwh) are calculated and based on the Base ETEC plus the available capability adjustments for products configured with UMA graphics all TEC Categories that apply to the Computer Model Family. 2

Number 7.1.1 (g) (k) Idle state; sleep mode; sleep mode with WOL enabled; off mode; and off mode with WOL enabled power demand. State/Mode (g) Idle State Cat. A (in W) 230 Volts AC (± 1%), 50 Hz (±1%) Cat. B (in W) 230 Volts AC (± 1%), 50 Hz (±1%) 6.92 Cat. C (in W) 230 Volts AC (± 1%), 50 Hz (±1%) Cat. D (in W) 230 Volts AC (± 1%), 50 Hz (±1%) (h) Sleep Mode 1.10 (i)sleep Mode with WOL Enabled 1.16 (j) Off Mode 0.40 (k) Off Mode with WOL Enabled 0.64 Number 7.1.1 (l) Internal power supply efficiency at 10 %, 20 %, 50 % and 100 % of rated output power. Internal Power Supply Efficiency at 230 VAC 10% Efficiency Not Applicable 20% Efficiency Not Applicable 50% Efficiency Not Applicable 100% Efficiency Not Applicable 3

Number 7.1.1 (m) External power supply efficiency. External Power Supply Efficiency at 230 VAC 0% No Load Efficiency (Unit of Measure in Watts) 25% Average Active Mode Efficiency (Unit of Measure in %) 50% Average Active Mode Efficiency (Unit of Measure in %) 75% Average Active Mode Efficiency (Unit of Measure in %) 100% Average Active Mode Efficiency (Unit of Measure in %) 0.086 W 88.10 % 88.94 % 88.79 % 88.63 % Number 7.1.1 (n) Acoustic noise levels (the declared A-weighted sound power level) of the computer. Acoustic Noise Levels (Bels) Idle 3.6 Operation 3.7 Number 7.1.1 (o) The minimum number of loading cycles that the batteries can withstand (applies ONLY to notebook 1 computers). Minimum Number of Loading Cycles Not Applicable Number 7.1.1 (p) The measurement methodology used to determine information mentioned in Number 7.1.1 (e) through (o). 1 Limited to integrated display size measured diagonally that is greater than 9 inches or greater than 6 Watts idle state power demand. Notebook category may include Tablets, Slates and Mobile Thin Clients. 4

Number Reference 7.1.1 (e) through (k) 7.1.1 (l) 7.1.1 (m) 7.1.1 (n) and (o) Methodology IEC 62623 Edition 1.0 2012-10 - Desktop and notebook computers - Measurement of energy consumption Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac- Dc and Dc-Dc Power Supplies Revision 6.6 (April, 2012) EN 50563:2011 - External a.c. - d.c. and a.c. - a.c. power supplies Determination of no-load power and average efficiency of active modes ECMA-74 11th edition (December 2010) Measurement of Airborne Noise emitted by Information Technology and Telecommunications Equipment And ECMA-109 2nd edition (December 1987) Declared Noise Emission Values of Computer and Business Equipment. Number 7.1.1 (q) Sequence of steps for achieving a stable condition with respect to power demand. Refer to EC 62623 Edition 1.0 2012-10 - Desktop and notebook computers - Measurement of energy consumption. See Test Setup steps listed below. For test sequence for specific modes, refer to the Test Setup section of the EC 62623 Edition 1.0 2012-10 standard. Number 7.1.1 (r) Description of how sleep and/or off mode was selected or programmed. Number 7.1.1 (s) The computer automatically enters a Sleep Mode after a period of user and network inactivity. Typical default time setting is < 30 minutes. This capability is programmed into the Operating System power management scheme (such as Microsoft Windows Operating System. Sequence of events required to reach the mode where the equipment automatically changes to sleep and/or off mode. Number 7.1.1 (t) For Sleep Mode, the computer must be left alone (no user or network activity) for a period of time (up to 30 minutes). For Off Mode, the PC must be shut off through use of the Operating System Software (Press Start, and select Shut down) to allow the computer to shut off. The duration of idle state condition before the computer automatically reaches sleep mode, or another condition which does not exceed the applicable power demand requirements for sleep mode. Number 7.1.1 (u) The computer must be left alone (no user or network activity) for a period of time (up to 30 minutes). The length of time after a period of user inactivity in which the computer automatically reaches a power mode that has a lower power demand requirement than sleep mode. 5

The computer must be left alone (no user or network activity) for a period of time (up to 30 minutes). Number 7.1.1 (v) The length of time before the display sleep mode is set to activate after user inactivity. The computer must be left alone (no user or network activity) for a period of time (up to 15 minutes). Number 7.1.1 (w) User information on the energy-saving potential of power management functionality is listed at the end of this form. Number 7.1.1 (x) User information on how to enable the power management functionality is at the end of this form. Number 7.1.1 (y) For products with an integrated display containing mercury, the total content of mercury is listed below. Mercury Content (mg) 0 6

Number 7.1.1 (z) Test parameters for measurements: test voltage in V and frequency in Hz, total harmonic distortion of the electricity supply system, information and documentation on the instrumentation, set-up and circuits used for electrical testing. Energy Efficiency testing is performed with an AC input of 230 (± 1%) Volts AC, 50 Hz (± 1%). Test information including required instrumentation, setup etc. for Computers is detailed in EC 62623 Edition 1.0 2012-10 - Desktop and notebook computers - Measurement of energy consumption. Test information including required instrumentation, setup etc. for Internal Power Supplies is detailed in Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies Revision 6.6 (April, 2012). Test information including required instrumentation, setup etc. for External Power Supplies is detailed in ): EN 50563:2011 - External a.c. - d.c. and a.c. - a.c. power supplies Determination of no-load power and average efficiency of active modes. Number 7.1.1 (aa) Information on whether the battery is user replaceable (applies ONLY to notebook 2 computers). Is the battery user replaceable? Not Applicable 2 Limited to integrated display size measured diagonally that is greater than or equal to 9 inches and greater than or equal to 6 Watts idle state power demand. Notebook category may include Tablets, Slates and Mobile Thin Clients. 7

8