Powerful IND690 technology for hazardous areas



Similar documents
Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

Industrial Balances PREMIUM Series 490 IBK/ITK/ISK

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

High-Precision Platforms

Multi-Range Programmable DC Power Supplies 9115 Series

Product Information Sheet UH36 Hi Pot Tester

Accuracy and Pharmacutical

Multi-Range Programmable DC Power Supplies 9115 Series

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

Supplementary Certificate of Approval NMI S669

Product Information Sheet UH28CS-12kV Hi Pot Tester

EC type-examination certificate UK/0126/0099

High Power Programmable DC Power Supplies PVS Series

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Multifunction devices

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Inductive sensor NI10-M18-Y1X-H1141

Electronic Control Devices The European Product Catalogue 2007

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Quick Connect. quick - simple - efficient.

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

X2 series balances INNOVATIVE FUNCTIONAL SOLUTIONS

Technical Information RIA14

DC Electronic Loads 8500 series

How To Use A Ds340 (Dsp)

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Analogue + IVS Electronic Throttle Controls for CUMMINS Engines

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Hand-held thermometer Model CTH7000

For medical, health and veterinary requirements

Electronic Control Devices The European Product Catalogue 2007

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Asset Management Solutions. EID Tags Electronic Weighing EID Readers

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Material test chamber with mechanical convection

Exceptional Accuracy and Durability for Tough Industrial Environments INDUSTRIAL FLOOR SCALES. VERTEX Industrial Floor Scales Heavy-Duty Design

Product Information Fire alarm panel 8000 C

Vacuum drying oven for non-flammable solvents

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

CompactLogix Power Supplies Specifications

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

1.44 kw Programmable DC Power Supplies XLN Series

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

3DLevelScanner II TECHNICAL DATA SHEET

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Lockout Specification BW Clip Maintenance-free single gas detector

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Terminal Boxes Series 8146

Digital input modules

Technical Data. Dimensions

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Instruction Manual. T3111 T3111L T3111P T3111Ex

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Micro Motion 3098 Gas Specific Gravity Meter

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

A9 A8 A6 A5 A4 KIOSK B8-C B6-C B4 CONTENTS. Short-Travel / Full-Travel Keyboards. Page 4 8. Page 12. Page 9. Page Page 13.

A good connection. International approvals.

Product Specification instalert Rapid Messenger Variable Message Sign

Digital inductive conductivity transmitter

Incubator with mechanical convection

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

3500/93 System Display

DCS Data and communication server

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Test equipment for temperature and its reduction

40.3. Control Relays and Timers

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Industrial Bar Code Scanners

IND131 IND131xx IND331 IND331xx

Operating instructions Platform/floor scales

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

OZW30. Central Unit SYNERGYR

Data Sheet FUJITSU Display E19-7 LED

Technical Data Sheet. 3DLevelScanner

3200L 32" Interactive Digital Signage Touch Display

S-series SQ Controller

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Industrial Bar Code Scanners

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

TX2123 RS485 TO ETHERNET ADAPTOR

LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: printmaterial

Transcription:

IND690XX Application terminal The extensive expansion options of the IND690 can also be used with the IND690xx: 8 application pacs (software modules) for totalising, formulation, filling, etc. Alibi memory Profibus interface Ethernet connection 2 types of housing Up to 9 serial interfaces Certification according to ATEX Directive 94/9/EC Cat. 3, Zones 2/22 Zone 2 According to ATEX Directive 94/9/EC Zone 22 Powerful IND690 technology for hazardous areas

Application terminal IND690xx Tough but sensitive even in hazardous areas Complies with ATEX Directive 94/9/EC for potentially explosive atmospheres Protection class IP69K ideal for the toughest working conditions BIG WEIGHT display bright, with graphics capability, even in poorly lit areas Excellent performance with software pacs to enhance further Easily integrated To see and be seen BIG WEIGHT display. Bright, fast and clear, this active dot matrix display shows the result of the weighing operation. Readable from a distance, the BIG WEIGHT display is ideal for professional users. Protected behind scratch-proof safety glass the display will not dim over time. 1 terminal, 2 models, 3 types of installation Sure to be just right for your purpose. Protected to Class IP69K and made of stainless steel, the bench model is also ideal for wall mounting, thanks to the adapter that allows it to be tilted and turned. Cables can be hidden underneath the best protection against dirt and damage. The built-in model is also uncompromising, featuring fast, universal installation, and maximum accessibility. Front side also IP69K + stainless steel. Keypad has a nice, substantial feel The generous, easy-to-clean membrane with smooth surface and raised, embossed buttons meets all requirements related to ergonomics, hygiene and durability. A connectable PC keyboard (MFII/PS2) or barcode reader makes data entry even faster and easier. Interfaces for secure connectivity The basic version is ready to go with an RS232 data interface (e.g. to connect a printer). Up to 8 more interfaces can be added easily and inexpensively for still greater modularity and flexibility. IND690 displays say it loud and clear. Available in many languages, to guide the user easily and reliably. BIG WEIGHT is a registered trademark of Mettler-Toledo (Albstadt) GmbH. German Patent 197 32 659. European Patent 0 895 071. 100% leakproof and yet open on all sides. Data and pulses for other devices.

Relationship between categories and zones Hazardous areas are frequently subdivided into different zones according to the degree of the hazard. Depending on the zone, different categories of electrical equipment must be used. Category Specified type of Permitted for use Also permitted IND690xx hazardous in Zone for use in Zone permitted atmosphere for use Gas/air mixture 3 Or vapor/air 2 mixture or mist 3 Dust/air mixture 22 EN 1127-1:1997 Since 1998 METTLER TOLEDO has operated an approved quality assurance system according to ATEX Directive 94/9/EC for the production of instruments intended for use in hazardous areas.

Application terminal IND690xx The frequency of occurrence of an explosive mixture How frequently is an explosive atmosphere expected? The answer to this question is used to define separate zones in a factory or plant: Hazardous, explosive atomospheres are present rarely and briefly Due to gases, vapors, mists Zone 2 Due to dusts Zone 22 The more frequently an explosion hazard is expected to occur, the higher the safety requirements for instruments used. The ATEX Directive 94/9/EC defines categories for the various safety levels. Safety level of instrument Category For use in Zones Very high level of safety 1 0, 1, 2, 20, 21, 22 High level of safety 2 1, 2, 21, 22 Normal level of safety 3 2, 22 Connection to the scale by weight Bench and stand scales Weighing ranges from 3kg/0.1g to 600kg/50 g. Certifiable Class II and III with resolution up to 32,000 verification scale intervals or 3x3000e multi-interval Pallet scales Weighing ranges from 300kg/50g to 3000kg/500 g. Certifiable Class III with resolution of 6000 verification scale intervals. Low profile scales Weighing ranges from 300kg/50g to 1,500kg/500g. Certifiable Class III with resolution of 6000 verification scale intervals. Height of guides 35mm or 45mm Floor scales Weighing ranges from 300kg/20g to 12t/2kg. Certifiable Class II and III with resolution of up to 6 000 verification scale intervals or 3x3000e multiinterval Floor scales with folding load plate Weighing ranges from 1500kg/ 200g to 3000kg/500g. Certifiable Class III with a max. resolution of 7500 verification scale intervals or 3x3000e multi-interval

Technical data application terminal IND690xx Housings/ambient conditions Bench model Housing Angled desktop Material Chrome-nickel steel DIN X5 CrNi1810 Suitable for wall mounting with the wall adapter Built-in model Housing Material, front Compact housing design for front panel mounting Chrome-nickel steel DIN X5 CrNi1810 Ambient conditions Protection IP69K (DIN 40050): resistant to highpressure/steam jet cleaning Ambient -10 to +40 C for accuracy class III temperature 0 to 40 C for accuracy class II For dimensions for all of IND690 housing, please refer to the dimensional diagrams Explosion protection Instrument IND690xx application terminal D line weighing platforms K line weighing platforms M line weighing platforms Type of protection G: II3G EEx nal [L] IIC T4 D: II3D T70 C IP69K G: II3G EEx na II T4 D: II3D T+50 C IP67 G: II3G EEx nr T6 D: II3D T+45 C IP67 G: II3G EEx na IIC T6 D: II3D T+50 C IP67 Display and data entry Standard functions Display Screen size Type Displayed data BIG WEIGHT display Display cover Keypad Type Surface Markings/ key design Key functions Durability Alphanumeric Entry Display field 195x46 mm Active, high-luminance VFD dot matrix display, graphics capability, green Weighing data, identification data, clear-text information (user guidance, error messages), graphic information, designation of function keys F1 to F6 Patented, large display, showing weight or other data, characters are up to 35mm high Scratch-proof, toughened safety glass Three-point membrane keypad with sensed key action, acoustic acknowledgement Closed, smooth surface of heavy duty polyester, with raised, embossed buttons Scratch-proof, multi-color text/symbol markings, important keys enlarged 6 keys A to F for identification data 6 function keys F1 to F6, with functionchange and info key 4 weighing-function keys Numeric entry pad 1 million keystrokes With keys F1 to F6, guided selection connection for external MFII/PS2 keypad, optional Weighing functions Taring Auto tare Tare preset Taring functions Gross select Zero set Unit select Dynamic weighing Stability detection Weighing process adapter Vibration adapter Test key Check mode Switching points Key-operated, by subtraction Automatic taring, on/off select Through keypad Through interface, e.g. from PC or barcode reader 999 tare-setpoint memory for frequently used tare values Tare addition, tare multiplication, provisional tare Gross displayed on pressing key Automatic or manual Key-operated selection of the following weight units: kg, g, lb, oz, ozt, dwt For weighing unsettled objects, e.g. animals Selectable cycle time and automatic printout Adjustable in 4 stages, with movement indicator Adapts scale to weighing operation, choice of 3 levels Damps the influence of vibration, choice of 3 levels Displays identity code (certification seal) On K weighing platforms, to verify measuring accuracy (internal auto-calibration) Displays measured weight at higher resolution 8 independent freely definable switching points for Base-, Form-, Count-, Sum- and Com-690

Technical data application terminal IND690xx Scale connections A maximum of 4 IDNet, SICS or analogue scales can be connected IDNet connection For all weighing platforms with an IDNet connection Load mounts with system solution point SICS connection Precision weighing with serial interface RS232 Industrial scales BBA/BBK Analogue connection Connection method Terminals inside Connectable METTLER TOLEDO scales type D..T, N..T, analogue scales Spider, load mounts RWM with system solution analogue Other connectable Number: 1 4 (350 Ω cells) scales Weighing cells: 1 12 (1000 Ω cells) Sensitivity: 0.4...3mV/V A/D converter Max. resolution (certifiable) 7500e Max. resolution (not certifiable) 450,000d DMS supply voltage 8.75V Min. numeral step (calibr.-ability) 0.58 _V/e Min. numeral step (no calibr.-ability) 0.058 _V/d Max. length of line 100m Stabilization time typ. > = 0.6s Reading change-rate, adjustable max: 20/s Data interfaces RS232 (COM1) Operating modes Barcode GA46 Other interfaces COM2... COM9 Dialog mode For devices with dialog compatibility; extensive instruction set for exchanging data with the scale; able to transmit soft ware and data, e.g. for updating software or saving data Print mode Free formatting for external strip printers (GA46) and form printers Receptacle for barcode reader, power supply present Receptacle for Printer GA46 Expandable to max. 9 interfaces (Accessories) General data Display functions Startup text Tare indicator DeltaTrac Date/time Info functions Identification data Quality/length Entry Naming Preset text Application Pacs Text up to 20 characters, displayed briefly on startup, configured to choice NET appears when tare weight is stored Analog display of dynamic readings, with markers for target value and plus/minus tolerances Applications: dispensing, classifying, checking 999-value DeltaTrac setpoint memory Quartz-accurate, 12- or 24-hour clock, automatic calendar, Europe, USA or free format Recall capability for all current weighing data, stored data and identification data For all displayed and data output data, choice of English, German, French, Spanish, Italian, Dutch or Polish. Other languages to order 6 alphanumeric identifiers, 30 characters On membrane keypad, external MFII/PS2 keyboard or interface (e.g. barcode reader) Keys A F with variable text field 999-place memory for frequently used text and identification data, each 20 characters see Accessories Power supply Voltage 100 to 240V, +10/-15%, 50/60Hz Power input 60VA approx. Power cable Length: 2.5m Approvals and standards EC conformity CE mark and conformity declaration Certification EC Directive 90/384/EEC, 93/68/EEC, EN 45 501, OIML R76, NTEP conformity Elec. safety EC Directive 73/23/EEC, 93/68/EEC, EN 60 950 concurring, UL, CSA approved EMC EC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC, EN 50 081-1, EN 50 082-2, EN 61 000-3-2

Technical data application terminal IND690xx Ordering information Model Order-No. IND690xx bench model 22 011 903 IND690xx built-in model 22 011 904 Packaging Carton, approx. 440x330x260mm (bench) Carton, approx. 550x450x280mm (built-in) Weight Gross approx. 5kg, net approx. 4,2kg (bench) Gross approx. 7kg, net approx. 4,7kg (built-in) Documentation Full installation and operating instructions on CD-Rom Application Pacs A selection of high-performance Pacs are available for special weighing tasks: Pac designation Function Order No. Count-690 Counting, totaling 22 011 941 Form-690 Formulating, totaling 22 011 942 Com-690 Computer dialog mode 22 011 943 Sum-690 Totaling on 3 levels 22 011 944 Fill-690 Dispensing 22 011 945 Batch-690 Multi-component dispensing 22 011 946 Control-690 Verifying, classifying 22 011 947 FormXP-690 Convenient formulating 22 011 948 with PC connection For a description of performance features, see Pac data sheet Dimensions (mm) IND690 bench model IND690 built-in model Accessories Multi-Range Application Terminal IND690xx Scale connections Order-No. A maximum of 4 IDNet, SICS or analogue scales can be connected IDNet-690 Connection 22 011 951 for IDNet scales AnalogScale-690 Connection for analogue 22 011 952 weighing platforms SICS-Scale-690 Connection for SICS 22 011 953 scales Connection cable 22 006 795 SICS scales, 3m Serielle Interfaces CL20mA-690 CL20mA interface, 22 011 954 7-pole fem. conn. CL cable, 3m 00 503 749 Male connector, 7-pole 00 503 745 RS232-690 RS232 interface 22 011 955 8-pole fem. conn. RS232-Kabel/DTE, 3m 00 503 754 RS232-Kabel/DCE, 3m 00 503 755 RS232-Kabel/PC, 3m 00 504 374 RS232-Kabel/9p, 3m 00 504 376 Male connector, 8-pole 00 503 756 RS485/422-690 RS485/422 interface 22 011 956 6-pole fem. conn., galvanic separation RS422/485 cable, 00 204 933 open end, 3m Extension cable for 00 204 847 RS422/485, 10m Male connector, 6-pole 00 204 866 Bluetooth-690 Wireless serial 22 011 958 Integrated antennae USB-690 USB slave 22 011 959 USB adapter cable, 0.2m 22 006 268 USB adapter cable, 3m 22 007 713 PS2-690 MFII/PS2 keyboard 22 011 960 connection Network interfaces Ethernet-690 Ethernet 10/100 Base T 22 011 961 Twisted pair 8-pole fem. conn. Twisted pair cable, 8-pin 00 205 247 RJ45, 5m Twisted pair cable, 8-pin 00 208 152 RJ45, 20m WLAN-690 wireless network 22 011 962 with stub antenna ProfibusDP-690 2xPG11 cable gland for 22 011 963 direct internal connection

Accessories application terminal IND690xx Digital I/O interfaces outside hazardous areas The 4-690 and 8-690 relay boxes are not designed for use in potentially explosive areas. They may only be used in non-hazardous areas, or in hazardous areas if additional safety measures are taken. Digital I/O Interfaces Order-No. 4I/O-690 4 input/4 output 22 011 965 interface, 19-pole fem. conn. Relay box 4-690 Relay box with 4 input/ 22 011 967 4 output, for connection to 4I/O-690 Cable, 10m, for connecting 00 504 458 4I/O-690 with the relay box Male connector, 19-pole 00 504 461 Relay box 8-690 Relay box with 8 input/ 22 011 968 8 output for connection to RS485/422-690 Conformity Quality certificates Analogue output Analogue Out-690 Analogue output 22 011 966 0-10V, 0-20mA, 4-20 ma, 5-pole fem. conn. Cable for analogue output, 00 204 930 open end, 3m D/A male connector, 5-pole 00 205 538 Certifiable memory AlibiMemory-690 Storage for metrologically relevant records. Replaces the alibi printer in certifiable applications. 22 011 950 Mechanical accessories Wall bracket for bench model, stainless steel 22 011 980 Floor stand for bench model, stainless steel 22 011 981 Stand base stainless steel 22 011 982 www.mt.com Sales and service: Subject to technical changes Mettler-Toledo GmbH 22012876. Printed in Germany