POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION



Similar documents
POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT OBSTRUCTION LIGHTS SOL LED SOLAR POWERED RED OBSTRUCTION SYSTEM

DuroSite LED End-to-End Linear Fixture - NSF. for Indoor and Outdoor Industrial Applications

Dialight Control and Monitoring System for Vigilant LED Based Obstruction System for High Intensity Installations. FAA Type B FAA Type C FAA Type F

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

STB Series Enclosures

Explosion-Proof Electric Unit Heaters

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Advantium 2 Plus Alarm

Evolve LED Area Light

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

Dialight LED Lighting Fixture Catalog. for Industrial and Hazardous Locations

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

SafeSite LED Based Signaling for Hazardous Locations

MEDMASTER EXTERNAL POWER SUPPLY

DuroSite TM High Bay Lighting

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

STR7 Low Profile LED Strip Luminaire

OUTPUT CABLE CONNECTIONS:

Evolve LED Garage Light

PAINT BOOTH LIGHTING

Terminal Boxes Series 8146

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

ADDENDUM #1(BID PACKAGE # 3)

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

GUE, GUB Junction Boxes

8146/5 Series Breaker Panelboards

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

Evolve LED Area Light

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

DISCONTINUED (1998) MINIATURE RELAY 1 POLE 1 to 2 A (FOR SIGNAL SWITCHING) FBR211 SERIES. RoHS compliant

Power Supplies 3. SDN-P DIN Rail Series

Fire Pump Controllers Remote Alarm Panels

Scraper Passage Indicator. Electrical Indicator. Features

Technical Data. Dimensions

DuroSite LED High Bay - UL / CSA. for Indoor and Outdoor Industrial Applications

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

GE Lighting. Evolve LED Wall Pack. N Series (EWNA) imagination at work

Model #: SMART2200CRMXL

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

PART 1 - INTRODUCTION...

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

FIRERAY 2000 Installation Guide

SECTION LOW VOLTAGE LIGHTING CONTROLS

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Evolve LED Area Light

Evolve LED Roadway Lighting

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

AZ420 MINIATURE GENERAL PURPOSE RELAY

Cove lighting and tight space RGB LED luminaire

ADM1TE 5/30A DIN rail single phase two wire energy meter

USER GUIDE. For more information visit

LED-INTA-0024V-41-F-O

3DLevelScanner II TECHNICAL DATA SHEET

Compact pressure switch Flameproof enclosure Ex d Model PCA

Evolve LED Flood Lighting EFH1

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Operating Instructions

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Product Guide Specification

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Microcor Wireless Transmitter (MWT)

RM4TG20 three-phase network control relay RM4-T - range V

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Technical Data. Dimensions

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Operating Instructions. UL325 Compliant Non-monitored

Operating Instructions

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Section D..General Auto Electrical Corporation

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Low Voltage Transformers Sealed, General Purpose, Dry Type

AOK i Series LED High Bay / Flood / Tunnel Light

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs

1 POLE - 5A SLIM POWER RELAY

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

ACS-30-EU-EMDR-10-MOD

Kit Watt Audio Amplifier

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

A good connection. International approvals.

Heating Cable. Construction

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

TIGER Drylac U.S.A., Inc Swenson Avenue St Charles, IL T F office.us@tiger-coatings.us

Myers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure

DISCONTINUED (2009) RA SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Safety instructions VEGADIS DIS81.CEIA/V****

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

Transcription:

Compliances: Class I, Division 2, Groups A B C D, T5 at -40 deg C to +55 deg C* Class I, Zone 2, Groups IIA IIB+H2 IIC, T5 at -40 deg C to +55 deg C* Certified FAA L-810 by Intertek Testing Service (ETL) per FAA AC 150/5345-43G Complies with ICAO Annex 14 Low Intensity Types A (10 cd) & B (32 cd) ETL Listed to UL 844 & UL 1598; Report No. 3110856CRT-009c ETL Listed to UL 1598A Marine Vessels ETL Listed to CSA C22.2 No. 137-M1981 & No. 250.0-04 Canada Registered ISO 9001:2008 Compliance to UK CAP 168 Table 6A.1 Low Intensity (Group A) American Bureau of Shipping (ABS) Type Approved Product The POL series of red LED aviation obstruction lights presents the highest grade technical features and the most options available in the industry. POL steady-burning obstruction lights are used to mark tall structures that present hazards to air navigation. At night, these lights warn pilots when installed in accordance with FAA AC 70/7460-1 and applicable FCC and ICAO rules. Note: FAA approved lamp number 631 See important alarms note on specifications page. Point Type Power Photometric Color Entry Classified Style & Options Supply Specification Area POL-21005 1: 120v F: FAA L-810 R: Red 10B: 1-inch, Bottom EX: Explosion-Proof D: Double ** 2: 220v F: ICAO Type A 34B: ¾-inch, Bottom Class I, Division 2 NC: NVG Compatible 3: 12v DC B: Trans. Canada M20B: Metric, Bottom Class I, Zone 2 S3: w/junction Box 4: 24v DC B: ICAO Type B M25B: Metric, Bottom single only * 5: 48v DC B: UK CAP 168 Group A 6: 277v POL-21005-1F-R-10B-EX-D * T6 at -40 deg C to +40 deg C ** 1-inch thread only For alarm, transfer, flashing and other control options, see page 2 POL-21005-1F-R-10B-EX With S3 Option Marine Treatment standard for the POL-EX and is used for all marine, high salt content air and corrosive environments. The fixture shall be treated for marine conditions by cleaning per US Department of Defense TT-C-490 method III, pretreated with chrome-free aluminum conversion coating per US MIL-C-5541 type II, epoxy powder base coat primer and glossy polyester powder coat finish in color RAL 6003 (FED-STD-595 color #14097) dark green. Powder coating per US Department of Defense MIL-PRF-24712A type VI and oven cured. OL-1.9.3 February, 2015

CONTROL & MONITORING OPTIONS ADD THE SELECTED UNIT TO EACH POL LIGHT * POINT OBSTRUCTION LIGHTS FOR SINGLE LIGHTS: -x voltage -1: 120v -2: 220-240v -3: 12V DC -4: 24V DC -S1 Flashes at the FAA specified flash rate of 30 +/- 10 per minute PL10760-x-S2 PL10760-x-S4 Non-isolated failure alarm. Upon failure, an alarm relay activates remote alarm contacts powered by the POL s normal line voltage. Required for alarm monitoring with a POC Controller. Isolated failure alarm. Upon failure, an alarm relay activates remote alarm contacts. The alarm contacts are isolated dry (voltage free) normally open and normally closed. FOR DOUBLE LIGHTS: -x voltage -1: 120v -2: 220-240v -3: 12V DC -4: 24V DC PL10760-x-DT PL10760-x-D2 PL10760-x-D2.2 PL10760-x-D4 PL10760-x-D4.2 PL10760-x-D7 PL10760-x-D8 PL10760-X-D10 PL10760-x-D14 PL10760-x-D15 head, power is transferred to the standby head. No alarm function. head, power is transferred to the standby head & to a primary head failure alarm line powered by the POL s normal line voltage. Both heads operating. Upon failure of the first head, the alarm contacts are activated powered by the POL s normal line voltage. head, power is transferred to the standby head and to alarm contacts. The alarm contacts are isolated (voltage free) normally open and normally closed. Both heads operating. Upon failure of one head, the alarm contacts are activated. The alarm contacts are isolated dry (voltage free) normally open and normally closed. Both heads operating & flashing simultaneously. No alarm function. One operating head that is flashing and one standby head. Upon failure of the operating head, power is transferred to the standby head and it flashes. No alarm function. One operating head is flashing and one standby head. Upon failure of the operating head, the standby head activates & flashes and a failure alarm line is activated powered by the POL s normal line voltage. Both heads operating & flashing simultaneously. Upon failure of the first head, the alarm contacts are activated. The alarm contacts are isolated dry (voltage free) normally open and normally closed. Both heads operating & flashing simultaneously. Upon failure of the first head, the alarm line is activated powered by the POL s normal line voltage. * The PL10760-xx Control Unit is Class I, Division 2 and must be installed within 3-ft (1-meter) of its associated POL-EX obstruction light. Proper installation and sealing in accordance with all applicable standards is the responsibility of the installer. See page 4 for enclosure details.

POL EX SPECIFICATIONS The red LED lighted (specify: voltage) aviation obstruction light shall be tested and certified FAA L-810 (ICAO low intensity Type B). The obstruction light shall operate properly at 50 or 60 Hz at an input voltage supply of 120V (93V to 144V) or 220V units (176V to 250V). Within the preceding ranges, the output to the LED board shall be a controlled, stabilized constant current. The obstruction lights shall be listed and labeled for use in hazardous locations: Class I, Division 2, Groups A, B, C, D & T5 and Class 1, Zone 2, Groups IIA, IIB+H, IIC with a temperature rating of T5 at max +55-deg C per UL844 & CSA C22.2 No. 137-M1981. The AC obstruction lights shall be listed Suitable for Use in Wet Locations to UL1598A Marine Vessels (for AC), UL1598 2nd Edition Luminaries; CSA C22.2 No. 250.0-08, 2nd Edition; UL50 11th Edition Standard for Enclosures for Electrical Equipment and CSA C22.2 No. 94-M91 Special Purpose Enclosures for use at -40 deg C to +55 deg C and sealed to IP66 ingress protection. The unit shall have passed the FAA certification tests: the constant high temperature test to +130 deg F (+55 deg C) and the constant low temperature test to -67 deg F (-55 deg C) conducted in accordance with US MILSTD-810F, Method 501.4, Procedure II; the wind-blown rain test conducted in accordance with US MIL-STD-810E, Method 506.3, Procedure I; and the humidity test shall be in accordance with US MIL-STD-810E, Method 507.3, Procedure I. The complete test regime shall exceed the requirements of NEMA 4X and IP 66. The light head shall be marine treated for corrosion resistance certified by the manufacturer to comply with the US Military Standard Salt Fog Test conducted per MIL-STD-810F, Method 509.4, Procedure I, paragraph 4.5.2. Marine Treatment: The fixture shall be treated for marine conditions by cleaning per US Department of Defense TT-C-490 method III, pretreated with chrome-free aluminum conversion coating per US MIL-C-5541 type II, epoxy powder base coat primer and glossy polyester powder coat finish in color RAL 6003 (FED-STD-595 color #14097) dark green. Powder coating per US Department of Defense MIL-PRF-24712A type VI and oven cured. The lens shall be strong soda lime glass and shall be smooth and rounded to reduce the adhesion of dirt, ice and snow. The glass shall be clear to maximize light transmissivity. The red emitting LEDs shall meet the chromaticity requirements of US MIL-C-25050. The high output LED s be the latest technology providing uniform light output in 360 degrees horizontal. The LED average life shall exceed 100,000 hours. The LEDs shall be soldered in a factory set position to insure consistent light output. Wire mounted raised LEDs that can be bent out of position shall be unacceptable and cause for rejection. The LED board shall be treated with a protective dielectric conformal coating for protection from moisture and corrosion. The power supply board shall include short circuit and open circuit protection and the unit shall be protected from line surges by metal oxide varistors (MOVs). There shall be a clear design element for the dissipation of LED heat to insure the LEDs do not fail prematurely. The red LED aviation obstruction light shall be POINTSPEC Series POL-21005-EX manufactured by Point Lighting Corporation. Important Note: Alarm and other control options must be selected at time of initial order by adding the proper PL10760 unit. The POL-EX LED light can only be monitored by 3 rd party systems or controllers by selecting a POL-EX with a PL10760 monitoring unit.

PL10760 ALARM & MONITORING UNIT The Alarm & Monitoring Unit must be installed in accordance with all applicable local electrical codes within 3-ft (1-meter) of the POL EX light fixture. The PL10760 monitors the LEDs and translates the signal into a form usable by a POC controller or other alarm scheme. Two listed enclosures are used depending on the functions required. The following are the standard applications. Enclosure A is used for the following versions: S2 S4 DT D2 D4 D7 Enclosure B is used for the following versions: D2.2 D4.2 D8 D10 D14 D15 PL10760 ENCLOSURE A Manufacturer: Crouse-Hinds File: QBCR.E10518 Class I, Divisions 1 & 2, Groups A B C D PL10760 ENCLOSURE B Manufacturer: Akron File: E139669 Class I, Divisions 1 & 2, Groups B C D NEMA 4X, 7, 9

POWER CONSUMPTION PER POL EX LIGHT HEAD Code Type Voltage Frequency Watts* ma VA* -1F FAA & ICAO A 120 AC 50/60 Hz 1.5 25 2.9-2F FAA & ICAO A 220 AC 50/60 Hz 2.1 25 5.5-3F FAA & ICAO A 12 DC --- 1.2 96 1.2-4F FAA & ICAO A 24 DC --- 1.5 62 1.5-5F FAA & ICAO A 48 DC --- 1.2 25 1.2-6F FAA & ICAO A 277 AC 50/60 Hz 1.9 24 5.9-1B ICAO B & TRAN CAN 120 AC 50/60 Hz 6.9 63 7.6-2B ICAO B & TRAN CAN 220 AC 50/60 Hz 6.9 34 7.4-3B ICAO B & TRAN CAN 12 DC --- 4.3 470 4.3-4B ICAO B & TRAN CAN 24 DC --- 4.3 230 4.3-5B ICAO B & TRAN CAN 48 DC --- 5.0 104 5.0-6B ICAO B & TRAN CAN 277 AC 50/60 Hz 6.9 28 7.9 Note: For option NC, add 1.0 watts (1.1 VA) *Power consumption for AC units includes the effect of the unit s power factor which accounts for the difference between watts and volt-amperes. Measurements were made at the nominal AC voltages. The operating range for 120v units: 93-144v; for 220v units: 176-250v; for 277v units: 263-291v. REPLACEMENT PARTS Note: Single POLs and the fixture heads of double POLs are permanently sealed. In the event of failure, the fixture must be returned to the factory for evaluation and repair. Note: Failure caused by surge normally requires fixture replacement inches (mm) WEIGHT, DIMENSIONS & SHIPPING DATA Multi-Pack Carton Weight Height Width Depth Qty Weight Dim (inches) POINTSPEC Single: 3.5 lbs 1.6 kg 8.6 (210) 6.0 (152) 5.0 (127) 12 47 lbs 21.3 kg 22 x 15 x 17 POINTSPEC Double: 11.8 lbs 5.4 kg 13.3 (337) 14.9 (378) 5.0 (127) 2 27 lbs 12.3 kg 19 x 19 x 19 Wind Loading: Effective Projected Area (EPA) for POINTSPEC Double 0.69 square feet P O I N T L I G H T I N G C O R P O R A T I O N Mail: P.O. Box 686, Simsbury, CT 06070 Plant: West Dudley Town Rd, Bloomfield, CT Tel 01 860.243.0600 USA Fax 01 860.243.0665 email: Info@PointLighting.com website: www.pointlighting.com