PARTICULATE MATTER MONITOR



Similar documents
How To Use A Ds340 (Dsp)

Online Infrared Flue Gas Analyzer Gasboard 3000

DUST EMISSION MONITORING SYSTEM

Dialight Control and Monitoring System for Vigilant LED Based Obstruction System for High Intensity Installations. FAA Type B FAA Type C FAA Type F

Repeaters and Mimics Data Sheet

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

3500/93 System Display

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

ABB PSPS Erich Steinmann; Generator control-2013

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Multi-Range Programmable DC Power Supplies 9115 Series

In-Sight Hardware specifications

Temperature & Humidity SMS Alert Controller

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

A-307. Mobile Data Terminal. Android OS Platform Datasheet

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

Analytical Instruments Smart Analyzer 90 Type SMA

Hygro-Thermometer + InfraRed Thermometer Model RH101

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

WEATHER STATION FOR SOLAR FARM MONITORING

Electronic Control Devices The European Product Catalogue 2007

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

PD 100A. Printing data system

O C M III. Open Channel Flow Monitor

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

PIEZOMETER AIRFLOW MEASURING RING

Permissible ambient temperature Operation Storage, transport

Senses SV series industrial monitor user manual

Rackmount Intelligent Pressure Scanners

S300 Series Dust Monitors

Product overview mm. 100 mm

SNMP Web Management. User s Manual For SNMP Web Card/Box

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

HMI display Installation Guide

Residual Gas Analyzers

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

T0118 T2118 T3118. Instruction Manual

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

3500/22M Transient Data Interface

Why a torque measuring system?

OZW30. Central Unit SYNERGYR

Alignment Laser System.

Interface Level And Point Level Analyzers & Sensors

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

REAL-TIME DUST AND AEROSOL MONITORING

1.0 What Are the Purpose and Applicability of Performance Specification 11?

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Application Requirement

Product Information Sheet UH28CS-12kV Hi Pot Tester

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Owner s Manual

Microcor Wireless Transmitter (MWT)

Considerations When Specifying a DC Power Supply

Wahl C50 Calibrator FEATURES

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Digital Controllers ACTUATOR COMPATABILITY

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

CE6500 Energy Recovery Ventilator

For Multi-Parameter Meters see mvx

Freezers - Ultrafreezers. Platilab & Irilab Series

High Power Programmable DC Power Supplies PVS Series

NC-12 Modbus Application

Continuous Monitoring Data Acquisition System

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

T7560A,B,C Digital Wall Module

NetScanner System. Toronto: , Montreal: , Toll Free: ,

Multi-Range Programmable DC Power Supplies 9115 Series

Modular I/O System Analog and Digital Interface Modules

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Digital Pressure Measuring Instrument MDR480

Electronic Control Devices The European Product Catalogue 2007

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Centro-Matic Automatic Lubrication Systems System Controls

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Duct Humidity Transmitter

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

Wireless Data Logger Monitoring Systems

The photoionization detector (PID) utilizes ultraviolet

WIND Power Technology: IMD Integrated Motor Drive


DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

3466 Building Energy Management Training Systems

MOUNTING AND OPERATING INSTRUCTIONS

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

PPM Users Manual Signature Software

Transcription:

Model 360 PARTICULATE MATTER MONITOR A COMPLIANCE PARTICULATE MATTER MONITOR

A Complete Quality System... PARTICULATE MATTER Monitor - Model 360 The most stable (under all operating conditions), accurate and maintenance free PS-11 compliant dust concentration monitor available! Meets EPA Performance Specification-11 The LaserHawk was designed to comply with the performance specification for continuous particulate monitors. A complete system includes an optical head, purge system, enhanced remote panel fulfilling all QA/QC requirements. Rugged Construction Holds Up Under Toughest Conditions The Optical Head is built of heavy gauge aluminum parts and finished with acid-resistant enamel paint. All exposed hardware is stainless steel. The rugged design and extremely low heat generation allows operation over a wide range of ambient temperatures. It is built to withstand the typical hostile environment associated with outdoor industrial applications, including substantial shock and vibration. Commonality of Parts TML has paralleled the design of the LaserHawk from its Model 560 LightHawk Compliance Opacity Monitor and the UltraFlow-150 Ultrasonic Flow Monitor. All utilize the same Enhanced Remote Panel; communication protocols, and mounting hardware. This saves the customer valuable inventory dollars and permits the use of spares on a variety of equipment. Ideal For Retrofit Applications The LaserHawk is a compact design that can be installed on ducts or stacks using a single 4-in. mounting port. There is virtually no alignment necessary since there is no refl ector assembly. Adapters are available to match any 3-6 in. existing mounting fl ange. With an optional I/O module, the Optical Head meets all PS-11 requirements without the need for a Remote Panel. The LaserHawk is ideal for OEM applications. Labor Saving On-Stack Controls All of the hardware and software needed for system setup, control and maintenance are packaged within a single optical housing. Via a membrane-sealed keypad and digital display, the user can perform clear-stack zeroing, span/zero setup, reset window dirt calculation following maintenance, input particulate mass correlation data and access the full set of diagnostic parameters. Ideal For OEM Applications The LaserHawk is easy to calibrate, but for ideal accuracy, it should be calibrated on-site using Method 5 or 17 Isokinetic Testing by a third party. Once the linear, exponential or polynomial correlation curve is input via the keypads on either the Optical Head or Enhanced Remote Panel, the cal kit can be used to set up zero, low, medium and high energy levels in the appropriate scale. User friendly menus on the keypads enable adjustments of gains and currents to ensure proper operation of the monitor. No potentiometer adjustments or resistor changes are required. Instantaneous or average dust concentration can be transmitted directly to a Data Acquisition System or via optically isolated analog signals, network or serial communication. Advanced Optical Design For Consistant Operation Some backscatter monitors don t operate well in heat, high noon conditions or when stack or duct walls shift slightly due to temperature, wind, etc. Not the LaserHawk. Its electronically modulated, intensity-controlled solid state laser beam ensures unusually stable operation, without interference from sunlight, room lights or backwall scattered energy. The monochromatic, coherent red laser beam has no alignment issues since the beam shines directly into the stack requiring no reflector assembly. Flexible Trouble-Free Operation The Optical Head and Enhanced Remote Panel of the LaserHawk are interconnected via a commercial network protocol, using transformer isolated data lines which nearly eliminate the potential effects of electro-static discharge. This approach provides great flexibility in choices of options and interconnect topology. One twisted pair is required for each system interconnection. The Optical Head and Remote Panel provide all parameters needed for maintenance and diagnostics. It is easily configured to any plant, Digital Control System, Data Acquisition System or control system. Optional Equipment Optional equipment with the LaserHawk includes; optional flange nozzle materials, high-temperature hardware, adapter flanges and dual analog input module for correction to standard conditions. Consult factory for application criteria and options for small diameter stacks.

A Complete Quality System... Purge System A purge air system is furnished with each LaserHawk. The system supplies purge air to the Optical Head, protecting the instruments from stack gases and significantly reducing maintenance intervals. A purge air sensing switch is provided in case of power loss or interruption. Purge fail/power fail alarm is standard. LaserHawk Optical Head The optical head is housed in a rugged NEMA 4 aluminum casting. The optical head contains the active electronics necessary to project a laser beam into the stack/duct and to receive back the scattered energy off the particulate. The sealed optical head subassembly is designed for simple cover removal, allowing complete access to the electronics. Remote Display Panel Uses a large, back-lit, LCD graphics display with Englishlanguage, menu-driven screens, providing ready access to all information needed for full use of the system. In addition, the user can graph up to the most recent 100 values of a selected parameter, such as: Instantaneous dust concentration, average dust concentration Calibration values (zero, upscale, or dust com pensation) The keypad, a rugged 20-button ensemble inlaid under a tough, hard coated, scratch and chemical-resistant coating, can be used to: Display dust concentration on a mg/m3 or gr/ cf basis Identify the cause of an alarm or malfunction Configure the relay outputs Configure the analog outputs Edit parameters such as voltages, currents and gains Set alarm values for dust concentration, zero cal and upscale cal Load correlation curves for particulate concentration Ethernet Interface The LaserHawk Enhanced Remote Panel now features a 10/100 Based Ethernet interface as standard equipment. This capability provides a multilevel password protected user interface to TCP/IP networks such as LAN s or the Internet. Client side user interface access is via standard web browsers. Simultaneous Modbus TCP access to instrument parameters and emission data is also supported. Optical Head Keyboard/Display Uses a 10 button keypad & 6 digit readout to display and/or enter: Instantaneous particulate concentration (mg/m3 or gr/cf) Average particulate concentration Zero calibration Upscale calibration Dust compensation Status codes Diagnostic data about the analog signals inside the optical head (no need to open the optical head) Particulate concentration curves Optical gains Calibration Kit The calibration kit, standard with the LaserHawk, is used as an additional check of the unit s proper operation and calibration. The cal fixture attaches to the front face of the optical head and various audit standards can be inserted to challenge the instrument over the dynamic dust concentration range that is established during on-site calibration. A zero (clear) condition can also be established.

Specifications PHYSICAL DIMENSIONS Optical Head (with cal mechanism) 15¾ (400mm) (L) x 9 (229mm) (W) x 14 (356mm) (H) Purge Blower Assembly 22-1/4 (565mm) (L) x 20 (508mm) (W) x 33 (838mm).(H) Enhanced Remote Panel 3U 19 (483mm) Rack Mount 5-1/4 (133mm) (H) x 9 (229mm) Depth OPTICAL CHARACTERISTICS Optical Measurement Technique Optical backscatter of light from a red laser Spectral Response 655 nanometers (nominal) +/- 20 nanometers SYSTEM PERFORMANCE Resolution: 0.5 mg per actual m3 MEASUREMENT RANGE MIN: 0 20 mg per actual m3 MAX: 0 1000 mg per actual m3 SYSTEM MEASUREMENT Response Time (to 95% of change) Less than 10 seconds CHARACTERISTICS Calibration Zero Operation On Command Upscale Calibration Operation On Command Stability Over Operating Temperature Range Stability Over Operating Mains Voltage Range ± 2.0% of Full Scale, Maximum per 40 F (22.2 C) change in temperature ± 1.0% of Full Scale POWER REQUIREMENTS Optical Head 85-245 VAC, 47-63 Hz, Single Phase, 30 VA Maximum Purge Blower System** 115 VAC/230 VAC, 60/50 Hz, Single Phase, 414 VA Maximum AMBIENT OPERATING CONDITIONS MEASUREMENT MEDIUM CONDITIONS OPTICAL HEAD HUMAN/MACHINE INTERFACE (HMI) CHARACTERISTICS ENHANCED REMOTE PANEL HUMAN/MACHINE INTERFACE (HMI) CHARACTERISTICS MULTI I/O BOARD ANALOG OUTPUTS MULTI I/O BOARD ANALOG INPUTS Enhanced Remote Panel Optical Head: Enhanced Remote Panel Static Pressure Range** Gas Composition Humidity Maximum Temperature** Display Type Indicating LED s User Input Controls Display Type ** Does not apply to Instrument Air Purge version. Consult factory. 85-245 VAC, 47-63 Hz, Single Phase, 30 VA Maximum Temp Range: -4 to +140 F (-20 to +60 C) (startup) -25 to +140 F (-32 to +60 C) (operating) Relative Humidity Range: 0 to100% condensing Temperature Range: +32 to +104 F (0 to +40 C) Relative Humidity Range 0 to 95% noncondensing Standard Purge Blower: -15.0 to +5.0 inches H20 (-3736 to +1246 Pa) Gauge. Range: >+5 in. H2O consult factory not critical must be noncondensing for valid measurement +500 F (260 C) (w/o High Temperature option) +1500 F (816 C) (w/high Temperature option) Consult factory for higher temp operation Six 7 segment LED s Fault, Set, In Cal, Power 10-key keypad Graphics mode liquid crystal with LED backlight Display Resolution 240 x 128 Indicating LED s Fault, Alarm, Power User Input Controls 20-key keypad, security keyswitch Number 4 Isolation Type Optical & capacitive barriers: channel to channel, channel to circuit common & earth Number 8 Modes Isolated and Non-isolated

Simplified Audit Procedures Under regulations, there are times when continuous particulate monitors (CPMs) are periodically set up under clear-stack conditions, the zero verified, and audit filters run. When the process is running, this requires removing the CPM from the stack. The LaserHawk is designed such that this can be done without the need of test stands. Furthermore, the LaserHawk can capture the audit filter readings at the stack level, making it easy for one operator to perform the test without the need of reading a strip chart. Like the traditional Teledyne Monitor Labs opacity product line, the LaserHawk measures zero, upscale cal, and dust compensation using only one moving part. The LaserHawk employs a single gearmotor that, unlike competitor designs, is located safely inside the sealed optical housing, completely isolated from the potential of damage from stack gas. The gear mechanism is also brake-isolated from the effects of vibration. Ethernet Interface The LaserHawk Enhanced Remote Panel now features a 10/100 BaseT Ethernet interface as standard equipment. This capability provides a multilevel password protected user interface to TCP/IP networks such as LAN s or the Internet. Client side user interface access is via standard web browsers. Simultaneous Modbus TCP access to instrument parameters and emission data is also supported. Training An Operation and Maintenance Manual is provided with the LaserHawk monitor. In addition, periodic hands-on training classes are offered at both the Colorado and Pennsylvania facilities. Training classes may also be scheduled at the customer s facility. A certified trainer conducts factory and customer-site training classes. How the LaserHawk works The heart of the LaserHawk Dust Monitor is an electronically modulated (2400Hz), intensity controlled solid-state red laser located in the Optical Head assembly. A beam from the laser is projected from the Optical Head into the stack and along a path through the effluent. The laser beam is reflected, refracted, absorbed and scattered in all directions by the particulate matter, including in the backwards direction. The scattered light re-enters the Optical Head, where it is evaluated by a signal detector. The measured signal is correlated to dust concentration using either a linear, exponential or polynomial correlation curve. The dust concentration is provided in units of mg/m3 (or grains/cf). Zero and upscale calibration drift tests are conducted utilizing a superior anti-vibration calibration mechanism design. The unit displays extremely low drift and is sure to operate in the widest variety of applications. User Support TML prides itself on providing reliable and competent service utilizing one of the largest service forces in the environmental instrumentation business. TML has multiple remote offices placing our technicians closer to the customer ensuring quicker response time to boost the customer s equipment availability. A Call Center may also be accessed for assistance 24-hour/ day/365 days/year. TML technicians are crosstrained and have individual skill sets which best support the customer s equipment. State-of-the- Art computer programs and databases enable instantaneous access to historical service records for each customer. These can be reviewed and checked while on site to identify problem areas. Commitment TML has over 35 years experience in providing state-of-the-art Continuous Emissions Monitoring products to a wide variety of industrial markets. TML is dedicated to working in partnership with its customers to solve any application needs.

Teledyne Monitor Labs Leading the Way in Emissions Monitoring Teledyne Monitor Labs offers state-of-the-art CEM technologies to CEM users. Its line of opacity/dust monitors were the first to use a patented Light Emitting Diode (LED) as the source. The UltraFlow 100 & 150 have proven to be the most reliable, drift-free way to monitor stack flow for mass emission based monitoring. Teledyne Monitor Labs Windowsbased RegPerfect Data Acquisition Software represents a quantum leap in flexible, configurable system for satisfying a wide range of reporting requirements. Together with TMLs Sensor-e analyzer line and CEM systems for NOx, SO2, CO, O2, CO2, NH3, TRS and other gases. TML is your one-stop center for total emission monitoring solutions. System Assembly Teledyne Monitor Labs, Inc. reserves the right to make changes in construction, design, specifi cations amd/or pricing without prior notice. 35 Inverness Drive East/ Englewood, CO 80112 Ph: 303-792-3300/ Fax: 303-799-4853 www.teledyne-ml.com PL/LAH/3/08