SYSTEM DESCRIPTION Termination Boards



Similar documents
SAFETY MANUAL SIL RELAY MODULE

SAFETY MANUAL SIL SMART Transmitter Power Supply

SAFETY MANUAL SIL Switch Amplifier

PROCESS AUTOMATION MANUAL OVERSPEED/UNDERSPEED MONITOR KF**-DWB-(EX)1.D ISO9001

SAFETY MANUAL SIL SWITCH AMPLIFIER

PROCESS AUTOMATION MANUAL. Universal Temperature Converter. KFD2-UT2-(Ex)*(-1) ISO9001

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

How To Use A Network Card With A Network Box (Ios) On A Microsoft Powerbook 2.5 (I2) (I3) (Io2) And I2 (Io) (Net) (Ipo) (

FACTORY AUTOMATION MANUAL ID-NET SETUP PROCEDURE USING PROGRAMMING BARCODES

Redundancy Module QUINT-DIODE/40

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

connecdim Gateway G1 Ethernet TCP/IP to DALI

FACTORY AUTOMATION MANUAL USB VIRTUAL COM PORT DRIVER INSTALLATION UNDER WINDOWS XP/WINDOWS 2000

IMR 6000/10../20../30

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

is then retained absolutely without interruption.

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Modular I/O System Analog and Digital Interface Modules

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Digital input modules

PHOENIX CONTACT Features

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

IO-DIM6 6-Channel, Digital to Analogue Converters

CompactLogix Power Supplies Specifications

Actuator-Sensor-Interface

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

I STAR COMPUTER CO., LTD

ADM1TE 5/30A DIN rail single phase two wire energy meter

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Power Supplies 3. SDN-P DIN Rail Series

MINI MCR-SL-R-UI(-SP)

Rack mounted telephone- and leased line modem for industrial applications

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

ISpac isolators. the perfect system

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

S-series DC to DC Power Supply

User Manual for CH-PFC76810

SINEAX U553 Transducer for AC Voltage

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

FACTORY AUTOMATION. Manual. Speed Monitor KHU8-DW-1.D

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

IO-RM3 3-Stage Relay Module

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Quick Connect. quick - simple - efficient.

PHOENIX CONTACT - 01/2007

Electronic overload relay EF19 and EF45

RM4TG20 three-phase network control relay RM4-T - range V

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

GAE953 Electrical Alarm Unit 19" with Indicator

ABB Drives. User s Manual HTL Encoder Interface FEN-31

E-STOP relays, safety gate monitors

New Media Power Socket Outlets. New Media Power Socket Outlets

Tina 2A/B Adaptor unit

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Pluggable interface relays CR-P Pcb relays

Telephone- and leased line modem for industrial applications TD-36

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Electronic overload relay EF65, EF96 and EF146

Product and functional description

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Original instructions Tina 3A/Aps Adaptor unit

DALI RC BASIC SO. Control unit Operating instructions

Emergency lighting units EM powerled

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Cross-beam scanning system to detect slim objects. 100 mm in

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Transcription:

PROCESS AUTOMATION SYSTEM DESCRIPTION Termination Boards Non-IS Termination Boards for Yokogawa CENTUM C3 and ProSafe RS ISO9001

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"

Contents 1 Introduction... 4 2 Installation... 5 2.1 DIN Mounting Rail...5 2.2 Termination Board Mounting...5 2.3 Connection...8 3 Operation... 9 3.1 Fault Signal and Alarm...9 4 Technical Specifications... 10 4.1 Technical Data...10 4.2 Supplementary Information...10 3

Indroduction 1 Indroduction The Termination Boards are designed to interface Yokogawa CS3000 R3/ProSafe RS I/O cards. Power feed-if required- and system connector to I/O cards is integrated in the Termination Board which results in noticeable space savings in the interface cabinet. The power supply should have a redundante design for increasing the availability of the system. The operating status of the power supply is monitored and reported via red flashing LED and relay output. There are two retainers on the back for mounting the Termination Board quickly and easily on to a standard DIN Rail in accordance with EN 60715 or integrated similar. Disconnecting is easy with aid of a screw driver to lever the two retainers. Field terminals (X10) HART connector (X3) Customer specified socket for a cable to an I/O module Terminal strip (removable) for redundant power supply and message contact for monitoring the power (X20) Figure 1.1 Termination Board 4

Installation 2 Installation 2.1 DIN Mounting Rail The devices are mounted on a 35 mm DIN mounting rail according to EN 60715. Figure 2.1 Example: DIN mounting rail UPR-MR (35 mm x 15 mm) 2.2 Termination Board Mounting Warning! Risk of short circuit Injuries and damage to the device are possible when working with live parts. Before working on the device, always disconnect the supply voltage. Connect the device to the supply voltage only after completion of the work. 5

Installation Mounting the Termination Boards The Termination Boards are mounted on the 35 mm DIN mounting rail. The DIN mounting rail runs centrally below the Termination Board. 1. Clip the Termination Board onto the DIN mounting rail. The Termination Board is now properly mounted and secured. Figure 2.2 Termination Board mounting Removing the Termination Boards Figure 2.3 Termination Board removing 6

Installation Vertical Mounting The Termination Board is designed for vertical installation. Advantage is, wiring of external connections can be made easily from cable ducts right and left hand side of the modules. So, the total lengths of the cabinet can be used for mountig the modules in one column. 112 ± 1 Figure 2.4 Vertical mounting 12 PEPPERL+FUCHS x TB-RS-AI16-KS-XXXXX 25 26 1 2 LABEL CUSTOMER X10 B A 16 15 14 13 11 10 09 08 07 06 05 04 03 02 01 X3 2 1 2 1 2 1 2 1 40 39 40 X1B 39 40 39 40 X1A 39 7

Installation 2.3 Connection Block Diagram GROUND BOARD X20 Alarm 1 2 3 4 5 6 PW1 (LD150) green PW2 () green K1 Figure 2.5 Block diagram power supply and fault signal Connection Power Supply Figure 2.6 Connection power supply and fault signal F2 F1 0V 24V Power feed & Alarm red (flashing) single power supply (minus interconnected on board) Alarm 1 2 3 4 5 6 X20 X20 redundant power supply (minus interconnected on board) Alarm 1 2 3 4 5 6 Power supply 1 Power supply 2 Alarm output (Dry contact NO) (Steady current) 8

Operation 3 Operation 3.1 Fault Signal and Alarm Power supply 1 Power supply 2 LED green LED red (flashing) PS ON and Fuse 1 OK PS ON and Fuse 1 OK PS ON and Fuse 2 OK PS PS PS ON and Fuse 2 OK PS ON and Fuse 1 OK PS ON and Fuse 1 broken PS ON and Fuse 1 broken PS ON and Fuse 2 broken PS ON and Fuse 2 OK PS ON and Fuse 2 broken LD150 LD150 LD150 LD150 LD150 LD150 PS PS LD150 Table 3.1 ON ON ON ON ON ON X20.1, 2 Alarm contact LD135 contact closed LD135 ON contact open LD135 ON contact open LD135 ON contact open LD135 ON contact open LD135 contact open LD135 contact open 9

Technical Specifications 4 Technical Specifications 4.1 Technical Data Supply Connection terminal X20 3+, 4-/5+, 6- (Fuse T2A) Rated voltage 21 30 V DC SELV/PELV, exceptions see data sheet Ripple < 10 % Rated current see data sheet Alarm terminal X20.1, 2, see data sheet Supply termination removable terminal block with screw terminals for 0.2 2.5 mm 2 Field termination spring terminals 0.2 1.5 mm 2 Ambient conditions Ambient temperature working: -15 50 C (5 122 F) storage: -15 55 C (5 131 F) Protection degree IP20 Humidity max. 95 % rel. humidity non condensing Vibration < 15 Hz, amplitude ± 2.5 mm/15 Hz as per IEC 68-2-6 Shock 1 g, 16 ms all space directions as per IEC 68-2-27 Table 4.1 4.2 Supplementary Information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. The galvanic isolation of all circuits on a Termination Board conform to the functional isolation level in accordance with EN 50178 with a rated isolation voltage of 50 V eff. This is only a small selection of the most frequently needed Termination Boards. A range of Termination Boards for other Yokogawa I/O modules are also available. Please contact Pepperl+Fuchs. 10

Notes 11

PROCESS AUTOMATION PROTECTING YOUR PROCESS Worldwide Headquarters Pepperl+Fuchs GmbH 68307 Mannheim Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com For the Pepperl+Fuchs representative closest to you check www.pepperl-fuchs.com/contact www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS Printed in Germany DOCT-3694B 06/2014