S Y N C H R O N O U S G E N E R A T O R S



Similar documents
A S Y N C H R O N O U S M O T O R S

Generators TEM. for small hydroelectric power stations. Electric Machines

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, HP

Turbo generators Best quality for thermal power plants

PM734F - Technical Data Sheet Winding 28

GE Power Conversion. Generators. 2,500 to 80,000 kva Up to 22,000 Volts

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

TABLE OF CONTENTS INTRODUCTION...3 ADVANTAGES...5 OPERATION CHARACTERISTICS...6 EXCITATION TYPES...8 CONSTRUCTIVE COMPONENTS...9 ACCESSORIES...

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

Annex-A TECHNICAL SPECIFICATION

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Single-Phase AC Synchronous Generator

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Mecc Alte 400Hz In Depth

Diesel Engine Driven Generators Page 1 of 6

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

Basics of Electricity

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

SYNCHRONOUS MACHINES

DIRECT CURRENT GENERATORS

Raising the waters. Lift irrigation is getting a boost from ABB s synchronous motors

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

Mounting Instructions. Torque Transducer. A en

Shaft grounding. Carbon brushes for shaft grounding are used in turbo-generators, in distinct AC- and DC motors and as a special application in Ships.

Unified requirements for systems with voltages above 1 kv up to 15 kv

BCI184E - Technical Data Sheet

Chen. Vibration Motor. Application note

ECOCIAT. Domestic hot water heat recovery unit

AC Electric Motors best practice

Operataing Manual. Single stage radial Fan. Model MKV/TKV

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

Transformer oil cooler ALFA A02

*ADVANCED ELECTRIC GENERATOR & CONTROL FOR HIGH SPEED MICRO/MINI TURBINE BASED POWER SYSTEMS

How To Build A Low Voltage Capacitor Lvcp

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Brochure. Electric generators to power the world

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

GE Power Conversion. Motors. Medium / High Voltage and High Speed 190 to 100,000 kw 250 to 134,000 HP

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Powerformer chosen for Swedish combined heat and power plant

Subminiature Load Cell Model 8417

Excitation.

Rules for Classification and Construction Additional Rules and Guidelines

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

AC-Synchronous Generator

Synchronous motor. Type. Non-excited motors

3. Three phase winding technology

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

RPV - RP - RA air handling units

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Principles of Adjustable Frequency Drives

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Thermistor motor protection

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Understanding Insulation Resistance Testing

Motor Fundamentals. DC Motor

CONTINUOUS AUTOMATED FLUX MONITORING FOR TURBINE GENERATOR ROTOR CONDITION ASSESSMENT

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Unit 33 Three-Phase Motors

Power Plant Electrical Distribution Systems

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

C Standard AC Motors

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

ELECTROPUTERE ROTATING ELECTRICAL MACHINES DIVISION

MEMBRANE VACUUM MINI PUMPS

Gas Turbine Power COMPACT, EFFICIENT, RELIABLE

vacon ac drives for mining & minerals

Water-cooled three-phase asynchronous motors. Type series K21B / K23B

Stepper motor I/O. Application Note DK Motion Control. A General information on stepper motors

Technical Specification. Generating Set with Waukesha engine burning natural gas

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

CRN A-F-G-E-HQQE 3x400D 50 HZ

ENERGY CONVENTIONAL THERMAL POWER ELECTRICAL, MECHANICAL & SEALING SOLUTIONS

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Permanent Magnetic Generator Construction Manual

Mounting Instructions for SP4 Power Modules

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

Lab 8: DC generators: shunt, series, and compounded.

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

Comparative study for cables and busbars

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

525-MVA Generator-motor and Thyristor Starter Put into Service at the Tokyo Electric Power Co., Inc. s Kannagawa Hydroelectric Power Station

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

Brochure. Generators for wind power Proven generators reliable power

Torque motors. direct drive technology

Transcription:

S E R I E S SYNCHRONOUS G E N E R A T O R S

INDAR SYNCHRONOUS GENERATORS S E R I E S BZK INDAR ELECTRIC INDAR, EXPERIENCE AND COOPERATION INDAR Electric develops and manufactures electrical rotating machines to respond to customer needs. Its experience is shown in the thousands of Indar Electric generators in operation all over the world. Cooperation with the customer is part of the company's philosophy, through special personal attention as the basis for the relationship and with a clear common objective: to develop products and services that adapt to the characteristics of each project. Indar Electric, an Ingeteam company, has worked for over sixty years Indar Electric has modern facilities equipped with the latest technology in its different sections; sheet metal die-cutting, machining, coiling, assembly and testing. Indar Electric is present in several continents through agencies and after-sales service centres, to guarantee a comprehensive service for its generators: technical assistance, maintenance, repairs and replacement parts. in the design, manufacture and supply of electrical rotating machines. CONSULTANCY SUPPLY MAINTENANCE TECHNICAL ASSISTANCE 2

SYNCHRONOUS GENERATORS - BZK SERIES The development of the BZK series has been based on the knowledge that Indar Electric has accumulated for decades in the manufacture of synchronous machines, combined with the use of advanced design tools that its R+D+i support unit uses. Technological innovation is a basic element in the company's development and has become an essential factor in keeping the company competitive in a demanding market. Synchronous brushless generators, 4,111 kva - 1,000 r.p.m., 6.3 kv, for a gas engine for Caterpillar. Modular construction The BZK series makes up a three-phase synchronous generator family designed for horizontal forms of construction. The equipment is designed to comply with different shaft centre heights and anchoring options. It can adapt to requirements on the basis of the drive through a modular design. The construction of the BZK is divided into: Casing: The stator core is welded onto the outer ferrule in a cylindrical manner, thus creating the main structure of the generator. Shields: Made of mechanically welded rolled steel, both for applications with bearings and those designed to bear radial and axial loads. 3

INDAR SYNCHRONOUS GENERATORS S E R I E S BZK CONSTRUCTIVE DESIGNS Knowledge of the physical phenomena that occur in synchronous machines, together with the latest software to calculate finite elements, have meant that the electro-magnetic design has been optimised, with excellent performance. The main characteristics of the BZK series are: Power (kva) 1,250-15,000 No. of Poles 4-10 Voltage (V) 690-15,000 Frequency (Hz) 50-60 Insulation Heating class Ambient temperature Standards F (H if required) F 40º C CEI, NEMA, VDE, ANSI Vibration requirements IEC 34-14 or ISO 10816 Other standards Overloads borne without damage occurring Bureau Veritas, Lloyd s Register, Det Norske Veritas 110% for 1 hour in a 6-hour period 125% for 15 minutes in a 6-hour period 150% for 2 minutes in a 6-hour period Power (kva) 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000 0 POWER RANGE OF BZK GENERATORS No. of Poles 4 6 8 10 4

SOLUTIONS FOR EACH APPLICATION The modular structure of the series means that the generator can be adapted to a wide range of applications based on power, speed or voltage to respond to market needs. The characteristics of the main drive or motor are also taken into account when configuring the generator, in terms of the level of cooling and protection required (adverse environments, high humidity, heat, etc.). BZK generators provide an energy generation solution for a number of sectors: Cogeneration: Gas or steam turbines, diesel or gas engines. Shipbuilding sector: Main and auxiliary generation. BZK 710 (main generation) 6,750 KVA, 1,000 r.p.m., 690 V, for a dredger of the Belgian ship-owner Jan De Nul. INDAR generators comply with current international legislation on the manufacture of electrical rotating machines: IEC, CEI, NEMA, etc. 5

INDAR SYNCHRONOUS GENERATORS S E R I E S BZK R&D AT YOUR SERVICE The team is made up by highly qualified professionals with considerable experience in design and manufacture. This, together with the application of modern simulation programs for finite mechanical elements and electromagnetic flows, means that we can provide solutions based on in-house technology to deal with customer requirements. Electrical and mechanical optimisation studies have been made using a number of finite element simulation programs: Electrical optimisation: Our knowledge of the physical phenomena that occur in synchronous machines, together with the latest software to calculate finite elements, has allowed us to optimise the electro-magnetic design of our machines and thus obtain higher performance. 0 / 0.125 0.125 / 0.25 0.25 / 0.375 0.375 / 0.5 0.5 / 0.625 0.625 / 0.75 0.75 / 0.875 0.875 / 1 1 / 1.125 1.125 / 1.25 1.25 / 1.375 1.375 / 1.5 1.5 / 1.625 1.625 / 1.75 1.75 / 1.875 1.875 / 2 6

COOLING AND PROTECTION INDAR offers a range of solutions, depending on the demands of the application or customer requirements, ranging from open air-cooled machines to closed machines with air/water cooling systems. OPEN MACHINES NOMENCLATURE OF PROTECTION CLASSES There are two configuration options: Those that take and expel the cooling air from machine room IC 01. They can be used in places where the air is relatively clean. Those that take ambient air from the machine room and expel the hot air through a duct outside of room IC 21. CLOSED MACHINES IP: first number Indicates the level of protection against accidental contact between live parts and the penetration of solid bodies. 2. Drives protected against objects larger than 12 mm. 4. Drives protected against objects larger than 1 mm. 5. Drives protected against penetration by dust. In cases in which the air is not sufficiently clean or not suitable for ventilation, the solution consists of completely closed generators with two types of cooling system: Those that take and discharge air outside through an IC 31 duct. Machines with IC-81W81W cooling have a closed air circuit. The air that is ventilated by the machine goes through the coolants located on the outside of the generator. The water that runs through the cooling units extracts the heat generated in the machine. IC-01 second number Degree of protection referring to the tightness of the drive against penetration by liquids. 3. Drive protected against drops of liquid at an angle of 60º (rain). 4. Drive protected against splashes in any direction. 5. Drive protected against water jets. 6. Drive protected against high seas. 7

INDAR SYNCHRONOUS GENERATORS S E R I E S BZK STATOR The stator package consists of low-loss thin sheets of magnetic silicon steel, which are die-cut and coated on both surfaces with insulating material to reduce losses from stray currents. The spaces that make up the radial air ducts in the core of the stator are distributed to ensure efficient cooling. The shields attached to the central part are studied by modern calculation methods such as Finite Element Modelisation (FEM) to bear the most demanding electromagnetic stresses. Magnetic core The magnetic core is held in place by tie bolts that make up a pressure box on the outside, with the help of some pressure plates with pins located on either side of the core. This system guarantees high mechanical rigidity of the magnetic core through an excellent compacting of the steel sheets. The bearings are located in the shields. They are designed to handle a range of cooling solution in terms of air inputs and outputs. The cooling of the magnetic core and coils is divided into a number of basic 'packages' with radial ventilation channels made up of sheet metal with spacers attached. The spacer core is selected to achieve uniform distribution of the pressure applied during the formation of the core, thus guaranteeing low hydraulic resistance to obtain the necessary air flow for cooling. Once the core has been formed a non-destructive test is carried out at low induction, with the aim of detecting short circuits between the plates. 8

COILS Formation of coils Each coil is made up of individually insulated copper platens. Once the coil is formed a number of layers of Mica tape are applied to ensure reliable insulation. After insulation, protection is applied to the rated voltage of the machine. The objective is to avoid differences of potential between the surface of the insulation and the iron of the magnetic package in the active part of the coil, and also discharges in the area around the head of the coil. The insulation of the generator is guaranteed to the Class F Standard used by Indar Electric, but it depends on the working environment or the specific needs of the customer. Class H insulation can also be used. Winding An element that guarantees the performance of Indar Electric generators is the high level of insulation of its components. The stator winding is three-phase and is insulated by the VPI System. This insulating system has excellent dielectric, thermal and mechanical characteristics. Its reliability is backed up by hundreds of machines that have been manufactured in recent years using this system, not only under normal operating conditions but also under transient conditions. Stator winding. Individually insulated copper platens. 9

INDAR SYNCHRONOUS GENERATORS S E R I E S BZK PROCESS OF IMPREGNATION Indar Electric generators undergo the most reliable processes to produce machines that will operate for decades, even under the most adverse conditions. As a result of this process of impregnation, the magnetic package, the coils, the wedges, the fastenings and the supports of the head make up a compact unit that is capable of supporting all the mechanical and electrical stresses the machine can be subjected to, even transient regimes as a result of discharges, disconnection operations, etc. The windings are characterised by: High mechanical resistance in all parts of the winding, due to the fact that the coils, the magnetic package and the supports have all been impregnated at the same time. Uniform dielectric strength throughout the circuit. Total absence of gaps in the insulation. This guarantees excellent thermal conductivity and good dielectric properties. High thermal capacity. All the insulating materials comply with Class F, and may therefore be continuously subjected to temperatures of up to 155º C. The insulating materials are not affected by humidity; if water does get into a particular area the machine can started up again after drying the wet surface. It is not sensitive to oil and other contaminants, and the low roughness of its surface avoids the accumulated of dust. High resistance to the effects of radioactive radiation. This means the machines can be installed in areas of high radiation in nuclear plants. The insulation system is inflammable and selfextinguishing. 10

ROTOR The design of the rotor is a key factor in the mechanical and electrical performance of the generator. The rotor of BZK generators is the best example of the work done by the company's R+D+i support unit in the ongoing optimization of the design of the generators. For 4 poles rotors: the rotor package consists of thin low-loss magnetic silicon steel sheets. They are diecut and coated on both surfaces with insulating material to reduce losses from stray currents. These sheets are pressed against each other, leaving radial channels that reinforce the cooling of the rotor winding and thus ensuring efficient cooling of the generator. For 6, 8 and 10 poles rotors: the rotor consists of rolled steel plates that are pressed together and welded to two discs to make up a compact core that is then linked to the shaft. The copper-insulated coils are inserted into the grooves and are insulated from the rotor sheet metal. The coils are held in place in the grooves by fibreglass wedges. The assembled rotors undergo tests in the tunnel to ensure their correct operation. The tests include dynamic balancing and overspeed tests to check the structural integrity of the components after the tests. The poles manufactured from rolled steel create a compact unit consisting of the earth and the polar coil. They are then subjected to an insulation process that gives them great rigidity and avoids air inclusions in the spirals. The rotor has a dampening coil that reduces the effect of unbalanced loads, improves the stability of the generators and dampens the oscillations caused by sudden load changes. The shafts used in the construction of the generators are manufactured with top-quality steel (forged or rolled) and then subjected to specific tests to check the homogeneity of the material. They are machined along their entire length and are polished on the surfaces where the bearings slide. The field winding consists of insulated copper. The current to this winding is injected through an exciter/rectifier bridge or a set of rings. 11

INDAR SYNCHRONOUS GENERATORS S E R I E S BZK BEARINGS Indar Electric offers two solutions, depending on the type of application: ball bearings or slide bearings. Ball bearings Under normal operating conditions they have a forecast working life of at least 50,000 hours. Slide bearings These have a working life of over 100,000 hours. This is the recommended system for high-speed or highvibration applications. They are installed under special manufacturing conditions (rotation speed, load-bearing capacity) or according to customer requirements. The lubrication of the bearings can be done in two ways, depending on operating conditions: self-lubricating or through an external lubricating mechanism. 12

CONNECTION BOXES In the BZK series, the connection box is assembled on top of the generator and includes the transformers required for excitation (T1 and T2). It is designed to enable easy connection of the cables and the installation of the current and voltage transformers for measurement and protection. Cable connections in the standard series can be either on the right or the left side. It is mounted on the stator and provides all the connections for the connection and protection elements: temperature sensors, excitation, current transformer outputs, heaters and similar equipment. For high- and medium-voltage machines, the auxiliary connection box is located away from the main connection box. The standard protection of the connection box is IP 54. The main connection box complies with Standard DIN 42962 in terms of distance between terminals, insulators and walls. 13

INDAR SYNCHRONOUS GENERATORS S E R I E S BZK TYPE OF EXCITATION The BZK series has a range of options, depending on the application and the voltage of the machine. Basically, there are three systems of brushless excitation: Powered by ancillary equipment. The AVR is powered by an external AC source. This is the simplest system although it is not always possible to apply it. If the power supply to the excitation equipment can be guaranteed it can comply with 3 In (and similar) demands. Powered by PMG. The excitation equipment is powered by a Permanent Magnet Generation mounted on the opposite side from the main generator. The PMG supplies the power required by the AVR, even in cases when it is necessary to comply with demands such as maintaining a level of short circuit for a short period. Powered by terminals on the generator. This is a system in which the equipment is powered by a transformer, whose primary is connected to the generator output and the secondary to the excitation equipment. In cases where 3 In is required or guaranteed, a Boost module is installed (with its corresponding transformer). 14

REGULATION Regulation system The regulation system is through a reliable microprocessor that can be custom-built. It regulates the output voltage of the brushless generators by controlling the current in the excitation of the generator field. For operations in parallel with the main generator, the way the power factor control is designed allows a continuous supply of reactive current. When supplying insulated networks, a single voltage control is used. 15

INDAR SYNCHRONOUS GENERATORS S E R I E S BZK GENERAL TESTS Components and the different parts of the generator are checked and tested throughout the manufacturing process. The controls include: Quality control, test to ensure insulation, inspection on reception of products, etc. These ongoing checks during the manufacturing process and the final tests guarantee the total reliability of Indar Electric generators. The routine tests that Indar Electric applies to its generators are: Measurement of the winding insulation. Measurement of the insulation resistance. Phase sequence and direction of turn. Vacuum curve. Short circuit curve. High voltage test. Overspeed test. Dielectric strength test. Checks on auxiliary components. PT 100. Heater. Regulator. Visual checks. Standard tests that Indar Electric carries out in accordance with Standard IEC 34 are: No load heating. Synchronous Machine. Test under Load. Heating under short circuit. Determination of losses and efficiencies. 16

STANDARD ACCESSORIES IN THE BZK RANGE PT-100 temperature sensors These are temperature sensors consisting of a platinum filament surrounded by cylinder-shaped ceramic material in a metallic sheath (in the case of bearings) or flat in the case of windings. All BZK machines have 6 PT-100 (2x3) installed in the winding, and 2 PT-100 in each slide bearings. If antifriction bearings are installed, there is 1 PT-100 in each of these bearings. Heating resistance Heat resistors keep the air inside the generator at 5ºC above ambient temperature. They are used to avoid oxidation from water condensation during long shutdowns of the machine, and to maintain the dielectric properties of the insulation. Optional accessories Indar Electric offer the following additional accessories. They can be included in the BZK range to cover any requirement. Cooling air filter. Air/water cooler with water loss sensor. PT-100 in hot/cold air. PT-100 in hot/cold water. Extra PT-100 in bearings. Thermometers. Current transformer for measurement and protection. Voltage transformer for measurement. Sea transport packing. Two single-phase power resistors are installed on both sides at the bottom of the generator. 17

INDAR SYNCHRONOUS GENERATORS S E R I E S BZK Power 4,111 kva Voltage 6.3 kv, Speed 1,000 r.p.m. Power 4,050 kva, Voltage 6.3 kv, Speed 1,500 r.p.m. Power 6,550 kva, Voltage 6.3 kv, Speed 1,500 r.p.m. 18

OUR FINAL PRODUCT Power 3,750 kva, Voltage 690 V, Speed 1,000 r.p.m. 19

Indar Electric, S.L. Polígono Industrial Txara, s/n 20200 BEASAIN - ESPAÑA Tel.: 34 943 02 82 00 Fax.: 34 943 02 82 04 electric@indar.ingeteam.com Una Marca Indar Electric, S.L. www.indar.net