Understanding Digital Modalities: System Integration and Use



Similar documents
Version 8 DICOM Conformance Statement. Version 3.04, September 2014

CARESTREAM PACS Suite (Client, Server, and CD Direct) Version DICOM Conformance Statement

DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement

DICOM 3.0 Conformance Statement

Infinity Medical Image Server

DICOM Conformance Statement

Technical Publication. DICOM Conformance Statement. DICOM Proxy 2.0. Document Revision 3. October 20, Copyright Brainlab AG

HP Medical Archive Solutions DICOM Conformance Statement. January 2007 (Third Edition) Part Number T

A PACS-Aware DICOM Image Object

MammoView 1.5. DICOM Conformance Statement 1.0. medigration GmbH All rights reserved

PARCA Certified PACS Interface Analyst (CPIA) Requirements

MiPACS Storage Server Conformance Statement Version

ClearCanvas ImageServer DICOM Conformance Statement

Technical Publications

DICOM Conformance Statement. DICOMscope 3.5. Software developed by: M. Eichelberg 1, K. Kleber 2, J. Riesmeier 1, A. Schröter 2, A.

DICOM Digital Imaging and Communications in Medicine

DICOM Conformance Statement For Diagnostic Review Workstation Software Version 5-x MAN-00546

Dx MM DICOM 3.0 Conformance Statement

Nio. Industry-standard diagnostic display systems

DICOM 3.0 Conformance Statement

DICOM 3.0 CONFORMANCE STATEMENT

ONIS 2.0 DICOM CLIENT. DICOM 3 Conformance statement

Supports screening, diagnostic, and multimodality workflows

DOLPHIN DICOM IMAGING DICOM CONFORMANCE STATEMENT

Technical Publications

DICOM CONFORMANCE STATEMENT FOR ZIOSTATION 2.0

PARCA Certified PACS System Analyst (CPSA2014) Requirements

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Technical Publications

Clarity the clear solution for managing digital medical imaging data

Health. NYC Quality Assurance Guidelines for. Primary Diagnostic Monitors

Consistency of Softcopy and Hardcopy: Preliminary Experiences with the new DICOM Extensions for Image Display

DICOM Conformance Statement

Picture archiving and communication systems (PACS) and guidelines on diagnostic display devices

DICOM CONFORMANCE STATEMENT FOR ZIOCUBE 1.0

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

Interfacing Fuji CR in a DICOM Network Environment

The Exposure Index and Its Standardization

Presentation Objective: Benefits to New Employee. Goal for Participants. Benefits to the Administration

Medical imaging monitors specification guidelines

Centricity Enterprise Web 3.0 DICOM Conformance Memo DOC

HDI 4000 Ultrasound System

PARCA Certified PACS System Analyst (CPSA) Requirements

Coronis 5MP Mammo. The standard of care for digital mammography

510(K) Summary K102148

Managing Clinical Imaging in EMRs. Guillermo Elizondo, MD, PhD Department of Radiology University Hospital, UANL Monterrey, NL Mexico

Technical Paper DENTAL MONITOR CALIBRATION

Success of DICOM standard

DICOM Conformance Statement FORUM

Technical Publications

Varian System Server. DICOM Conformance Statement

CAR Standards for Teleradiology

GE PACS Conformance Statement for DICOM v3.0

DICOM Conformance Statement

Department of Veterans Affairs VHA DIRECTIVE Veterans Health Administration Washington, DC February 8, 2011

SOP #: Revision #: Current Version Implementation Date: Page #: Page 1 of 10 Last Reviewed/Update Date: Expiration

DICOM, HL7, RIS, PACS

The Ongoing Relationship of PACS with the RIS, the HIS, and Other TLAs. Richard L. Morin, Ph.D., FAAPM

Introduction CDR Dicom for Windows is designed as a fully functional DICOM (Digital Imaging Communications of Medicine) based client-server

Quality Control and Maintenance Programs

DICOM Conformance Statement

AquariusNET DICOM Conformance Statement. DICOM Conformance Statement. AquariusNET 4.4. Rev B

Emory University RT to Bachelor of Medical Science Degree Medical Imaging

g GE Medical Systems Advantage Cluster Storage / Archive System Release 1 v Conformance Statement Direction number: Revision: 2

Physics testing of image detectors

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

PARCA Certified PACS Associate (CPAS) Requirements

Getting to Know Avreo

RADIOLOGY HOUSE STAFF MANUAL

DICOM Conformance Statement

Network Management for Picture Archiving and Communication Systems (PACS)

DICOM: Definitions and Testing

The New Enhanced Multiframe CT and MR DICOM Objects

ACR AAPM SIIM PRACTICE PARAMETER FOR DIGITAL RADIOGRAPHY

Workstation, Server Hosted

INTRODUCTION. A. Purpose

Diagnostic Exposure Tracking in the Medical Record

Imaging in Indian Health:

IHE Radiology: Mammography User s Handbook

ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research.

Fast mobile reading on the go November syngo.via WebViewer. Unrestricted Siemens AG 2013 All rights reserved.

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

Highmark Professional Provider Privileging Application Teleradiology Supplement INSTRUCTIONS

RIS. Complete -Complete exam on RIS *** [! - 9 ] ***

Golder Cat-Scan & MRI Center Automates Imaging Center Workflows

Migration of Medical Image Data Stored through Mini-PACS to Full-PACS

Page: 1 of 6 Page: 1 of 6

Parkway College of Nursing and Allied Health School of Nursing and Allied Health. BSc (Hons) Diagnostic Radiography and Imaging Module Synopses

DigitizingStation. DICOM V3.0 Conformance Statement

Computed Radiography: Acceptance Testing and Quality Control

HIMSS Analytics Europe Database. Sample Hospital 1 Unique ID# Hospital Profile. Name of Hospital. Background Information. Hospital Statistics

Thyroid Uptake Systems The Ultimate... User Friendly... Intuitive Captus 3000 Thyroid Uptake And Well System

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

MERGE PACS : PRODUCT ROADMAP. Dennis Roscoe, Ph.D., Director PACS Solution Management, Merge Healthcare Tuesday, August 28, 2012

Transcription:

Understanding Digital Modalities: System Integration and Use Donald J. Peck, PhD Henry Ford Health System Detroit, MI donaldp@rad.hfh.edu

Dicom Digital Imaging and Communications in Medicine Part 3: Information Object Definitions Image objects Non-image objects Dicom elements Defines specific information about the object Requires specific value representation (VR) for element Structure/Format, Information order, etc. Each element has a numeric Tag Group Number followed by an Element Number e.g. (0010,0020) = Patient ID AAPM 2004 2

Dicom Image Objects (26) Non-Image Objects (33) CR - Computed Radiography CT - Computed Tomography MR - Magnetic Resonance Enhanced MR NM - Nuclear medicine DX Digital X Ray US Ultrasound MF - Multi-Frame SC Secondary Capture MF - Multi-Frame SB - Single Bit GB - Grayscale Byte GW - Grayscale Word TC - True Color XA X Ray Angiography RF X Ray Fluoroscopy RT - Radiation Therapy Image PET Positron Emission Tomography DX Digital Radiography MG Digital Mammography IO Digital Intra Oral VL Visible Light EN - Endoscopy MC - Microscopic SL - Slide PH - Photographic ST - Stand Alone Object OV Overlay CV Curve Mod LUT Modality look-up-table VOI LUT Value-of-interest look-up-table PET CV PET Curve Basic Study Description Gray Scale Presentation State Stored Print Enhanced MR Spectroscopy Raw Data RT Radiation Therapy Dose Structure Plan Beam Record Brachy Record Sum WF Waveform Basic Voice Audio 12 Lead ECG General ECG Ambulatory ECG Homodynamic Basic Card EP SR Structured Report Basic Text Enhanced Comprehensive Key Object Selection Mammography CAD Chest CAD AAPM 2004 3

Dicom All PACS vendors have the ability to view Dicom information Information utilization: Determine acquisition system and location Radiographic technique QA Dose determination Setup display annotations Verify acquisition or processing parameters used Private Tags Used for proprietary or vendor specific information may not be visible AAPM 2004 4

What Does a Physicist Need to Know What elements does the Modality use Majority of elements are optional Dicom committee knows more mandatory elements need to be included in future standard What elements can the PACS use Many optional elements are not supported by PACS Is Modality supporting current and/or retired object standard As technology and utilization changes, Dicom standard changes AAPM 2004 5

CT/MR Object Developed over 10 years ago Defined viewing and annotation for standard series only Advanced application elements are optional or non existent Processing information is stored in private tags only Increased data set sizes and hanging protocols not handled well, if at all AAPM 2004 6

Dicom changes New objects include advanced features: Multi-slice data Mandatory acquisition parameters Specialized data interchange and archiving Raw data storage Post processed data handling CT MRI Total Elements Mandatory Elements Total Elements Mandatory Elements Original Standard 18 0 44 2 New Standard 41 39 103 94 AAPM 2004 7

Dicom Modality Worklist (DMWL) Basic Worklist Management Service that supports the transfer of information for scheduled studies from Radiology Information System to Modality. MWL Elements (over 50) (0040,0002) Scheduled Procedure Step Start Date (0040,0003) Scheduled Procedure Step Start Time (0040,0007) Scheduled Procedure Step Description (0008,0050) Accession Number (0010,0010) Patient s Name, last^first (0010,0020) Patient ID (0008,0060) Modality (0040,0006) Scheduled Performing Phys. Name AAPM 2004 8

Workflow Pre PACS Information Management Patient Management Image Processing 1 RIS Scheduled Study 4 Obtain Patient 6 Submit for processing 2 RIS Forms Print 5 Position Patient 7 Reload Cassettes 3 Study Folder Prep. 9 Acquire Image? repeats 8 Review Films 11 File & send folder 12 RIS exam complete 10 Select, window and print images AAPM 2004 9

Workflow Fully Functional PACS X Information Management Patient Management Image Processing 1 RIS Scheduled Study 2 Obtain Patient 5 Submit for processing 3 Modal. Modal. Worklist RIS Forms Print 4 Position Patient Reload Cassettes Study Folder Prep. Acquire QC and Image send PPS? repeats exam compl. 6 Review Images File & send folder 7 Performed Procedure Step RIS exam complete Select, window and print images AAPM 2004 10

Scheduled Procedure Step Description Institution generated description of study Purpose of this attribute is to store a description or classification that is used at a local level This description need not comply to an accepted standard Can allow integration of x-ray generator control to be preset for scheduled exams/views Requires programming on Modality to register technical parameters for all studies that may be scheduled AAPM 2004 11

Utilization by Modality For each study received from MWL an icon or listing of each ordered view is displayed e.g. AP and Lat For each listed view the appropriate technique is automatically set: kvp ma timed/aec Grid required (e.g. reminder displayed) AAPM 2004 12

Recommendations Insist on implementing MWL services on all modalities Carefully examine the query parameters in relationship to MWL database server Workflow improvements can be achieved by implementing Performed Procedure Step (PPS) and other features included in the standard e.g. Scheduled Procedure Step Description Virtually all Modality suppliers support MWL! However, support for other attributes such as PPS and other features are limited. AAPM 2004 13

Image storage and display Modalities may acquire, locally store and send data differently Raw and processed Processed only For CR/DX Objects values sent can be varied 8 12 bit Optical Density (OD) Presentation values (P-values) Log (exposure) AAPM 2004 14

Image VOI CR/DX modalities process raw values and convert them into log(exposure) space Then for a specific value of interest (VOI) range, log(exposure) values are converted to OD or P values using a Look Up Table (LUT) 4000 Raw Image Value Stored Image Value 0 AAPM 2004 15

OD values Film Image presentation values intended for film are printed to optical densities from 0 to 3.0 (+base) 4000 OD 3.0 3000 2.0 2000 1000 1.0 Image Value Optical Density 0 AAPM 2004 16

OD values Softcopy OD values presented on a softcopy display have a luminance ratio of ~350 (i.e. OD range of 2.5 ) 4000 OD 3000 3.5 2000 35 1000 Image Value Log(luminance) 1 to 350 cd/m 2 350 AAPM 2004 17

OD values Softcopy To allow OD values presented on a softcopy display to have a similar appearance to film window and level functions are used 4000 OD 3000 3.5 2000 35 1000 Image Value Log(luminance) 1 to 350 cd/m 2 350 AAPM 2004 18

OD values Softcopy To see the dark regions of the image the window level is changed 4000 3000 OD 3.5 2000 35 1000 350 Image Value Log(luminance) 1 to 350 cd/m 2 AAPM 2004 19

Luminance response softcopy vs. film OD values sent to film printer produce a luminance response with log(luminance) proportional to image value DICOM calibrated softcopy display characteristics produce a response with increased contrast in darker portions of image Therefore, OD values sent to a calibrated softcopy display produce increased brightness and decreased contrast in darker regions of the image Luminance (cd/m 2 ) 1000 100 10 1 0.1 Softcopy Film, OD DICOM Calibrated response 0 100 200 300 400 500 600 700 800 P value (JND index) AAPM 2004 20

Recommendations Modalities should be configured to send OD values to a printer and P values to PACS to produce equivalent appearance AAPM 2004 21

The DICOM VOI LUT sequence Configuring CR/DX modality to send VOI/LUT removes the need for applying VOI and removing acquired information Requires PACS to apply and vary the VOI/LUT on the softcopy display workstation in real time 4000 VOI/LUT VOI/LUT VOI/LUT 3000 2000 Raw image values P- values 1000 AAPM 2004 22

Using VOI/LUT with PACS PACS workstations should be capable of translating or stretching the VOI/LUT to make contrast and brightness changes P value 4000 3000 2000 1000 Raw Image Value AAPM 2004 23

Recommendations Calibrate monitors using a DICOM grayscale with a specified luminance ratio (~350) Configure your modalities and PACS to send and receive VOI/LUT sequences However, many reputable CR/DX suppliers have not released software support for P-values and many reputable PACS suppliers do provide functions to shift and stretch VOI/LUT sequences! CR / DX PACS VOI LUT Y P Value Y AAPM 2004 24

More Information AAPM 2004 Continuing Education Dicom Definitions and Testing Monday 8:30 rm 303 Digital Image Management Systems Tuesday 7:30 rm 317 RSNA 2004 Refresher Courses x53: Advanced PACS: How to Configure and Tune a PACS 726: A Survival Guide to Quality Control for PACS SCAR SPIE AAPM 2004 25