1 Version 2.7 DICOM 3.0 Conformance Statement 1

2 1. Conformance Statement Overview SOP Classes Query and Retrieve Study Root Query/Retrieve Information Model Find Study Root Query/Retrieve Information Model Move Transfer Table 1.1 Network Services User of Service (SCU) 12-Lead ECG Waveform Yes Yes Ambulatory ECG Waveform Yes Yes Basic Text SR Yes Yes Basic Voice Audio Waveform Yes Yes Blending Softcopy Presentation State Yes Yes Cardiac Electrophysiology Waveform Yes Yes Color Softcopy Presentation State Yes Yes Comprehensive SR Yes Yes Computed Radiography Image Yes Yes CT Image Yes Yes Digital Intra-oral X-Ray Image (Presentation) Digital Intra-oral X-Ray Image (Processing) Yes Yes Digital Mammography Image (Presentation) Digital Mammography Image (Processing) Yes Yes Digital X-Ray Image (Presentation) Yes Yes Digital X-Ray Image (Processing) Yes Yes Encapsulated PDF SOP Class Yes Yes Enhanced MR Image Yes Yes Enhanced SR Yes Yes General ECG Waveform Yes Yes Grayscale Softcopy Presentation State Yes Yes Hardcopy Color Image Yes Yes Hardcopy Grayscale Image Yes Yes Yes Yes Yes Yes Provider of Service (SCP) Yes Yes Yes Yes 2

3 Hemodynamic Waveform Yes Yes Key Image Object SOP Class Yes Yes Key Image Object SOP Class Yes Yes MR Image Yes Yes Multi-frame Grayscale Byte Secondary Capture Image Multi-frame Grayscale Word Secondary Capture Image Multi-frame Single Bit Secondary Capture Image Multi-frame True Color Secondary Capture Image Nuclear Medicine Image Yes Yes Ophthalmic Photography IOD 16 Bit Image Yes Yes Ophthalmic Photography IOD 8 Bit Image Yes Yes Pseudo Color Softcopy Presentation State Yes Yes Positron Emission Tomography Image Yes Yes RT Beams Treatment Record Yes Yes RT Brachy Treatment Record Yes Yes RT Dose Yes Yes RT Image Yes Yes RT Plan Yes Yes RT Structure Set Yes Yes RT Treatment Summary Record Yes Yes Secondary Capture Image Yes Yes Stand-alone Curve Yes Yes Stand-alone Modality LUT Yes Yes Stand-alone Overlay Yes Yes Standalone PET Curve Yes Yes Stand-alone VOI LUT Yes Yes Stereometric Relationship Image Yes Yes Stored Print Yes Yes Ultrasound Image Yes Yes Ultrasound Image Yes Yes Ultrasound Multi-frame Image Yes Yes Video Endoscopic SOP Class Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 3

4 VL Endoscopic Image Yes Yes VL Microscopic Image Yes Yes VL Photographic Image Yes Yes VL Slide Yes Yes X-Ray Angiographic Image Yes Yes X-Ray Radiofluoroscopic Image Yes Yes Verification Verification Yes Yes Table 1.2 Media Services Media Application Profile Write Files (FSC) Read Files (FSR) CD Recordable General Purpose CD-R See conformance note Yes General Purpose Secure CD-R See conformance note No DVD Recordable General Purpose DVD-R See conformance note No General Purpose Secure DVD-R See conformance note No 4

5 2. Table of Contents 1. Conformance Statement Overview Introduction Revision History Legal Notices Copyright Notice Trademark Acknowledgements Contact Address Definitions, Terms and Abbreviations References Implementation Model SCP AE Application Data Flow Diagram Functional Definition of AE Sequencing of Real World Activities SCU AE Application Data Flow Diagram Functional Definition of AE Sequencing of Real World Activities DICOM DISC Writer AE Application Data Flow Diagram Functional Definition of AE Sequencing of Real World Activities Query and Retrieve SCU AE Application Data Flow Diagram Functional Definitions of AE Sequencing of Real World Activities Query and Retrieve SCP AE Application Data Flow Diagram Functional Definitions of AE Sequencing of Real World Activities

6 4.6. Importer AE Application Data Flow Diagram Functional Definitions of AE Sequencing of Real World Activities Verification AE Application Data Flow Diagram Functional Definitions of AE Sequencing of Real World Activities AE Specifications SCP AE SOP Classes Association Establishment Policies Association Initiation by Real World Activity Association Acceptance Policy SCU AE SOP Classes Association Establishment Policies Association Initiation by Real World Activity Association Acceptance Policy DICOM DISC Writer AE File Meta Information Real World Activity Store Images on DICOM DISC Query and Retrieve SCU AE SOP Classes Association Establishment Policies Association Initiation by Real World Activity Sop Specific Conformance to C-Move SOP Class Association Acceptance Policy Query and Retrieve SCP AE SOP Classes Association Establishment Policies

7 Association Initiation by Real World Activity Association Acceptance for Real World Activity Importer AE Initiation by Real World Activity Import Images Verification AE SOP Classes Association Establishment Policies Association Initiation by Real World Activity Association Acceptance for Real World Activity Accept Verification Communication Profiles Supported Communication Stacks TCP/IP Stack API Physical Media Support Support of Extended Character Sets Configuration Configurable Parameters Host Configuration SCP AE Query and Retrieve SCU AE Query and Retrieve SCP AE Peer Configuration Security Security Profiles Association Level Security Application Level Security

8 3. Introduction This document describes the conformance of the expedo Application Suite to the DICOM 3.0 Standard [DICOM] Revision History Revision Author Comments Date 1 Matthew Gray Created 05/20/ Matthew Gray Updated 06/29/ Timothy Krehl Updated 06/10/ Dion Barrier Updated 07/07/ Dion Barrier Updated 07/27/ Lara Zimberoff Updated 02/13/ Legal Notices Copyright Notice Sorna Corporation. All rights reserved. No part of this document may be copied or reprinted, in whole or part, without written permission. The contents of this document are subject to change without notice or legal obligation Trademark Acknowledgements expedo is a registered trademark of Sorna Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. This document may include trademarks or registered trademarks of other companies Contact Address Sorna Corporation 2020 Silver Bell Road Suite 17 Eagan, MN Definitions, Terms and Abbreviations AE Application Entity ANSI American National Standard Institute DICOM Digital Imaging and Communications in Medicine FSR File Set Reader FSC File Set Creator IOD Information Object Definition ISO International Organization for Standardization NEMA National Electrical Manufacturers Association SCP Service Class Provider SCU Service Class User 8

9 SOP TCP/IP UID XML Service-Object Pair Transmission Control Protocol/Internet Protocol Unique Identifier extensible Markup Language 3.4. References [DICOM] Digital Imaging and Communications in Medicine (DICOM), NEMA PS ,

10 4. Implementation Model 4.1. SCP AE Application Data Flow Diagram Figure 4.1 SCP AE Dataflow Functional Definition of AE The SCP AE accepts connections to the configured AE title s presentation address. Associations having presentation contexts with SOP classes will be accepted Receive Images The Receive Images operation is initiated by a successful association with a remote AE requesting to store images. Images received from the remote AE are sent to an image storage system(s). The system(s) to which received images are sent are determined by configuration for the destination AE title Sequencing of Real World Activities Figure 4.2 Example Real World Activity for SCP AE 10

11 4.2. SCU AE Application Data Flow Diagram Functional Definition of AE Figure 4.3 SCU AE Dataflow Send Images The Send Images operation is initiated in response to Query and Retrieve or DICOM DISC media import operations. An association is initiated with the destination AE and is followed by a transfer of the requested images using C-Store operations Sequencing of Real World Activities Not Applicable 11

12 4.3. DICOM DISC Writer AE Application Data Flow Diagram Functional Definition of AE Figure 4.4 DICOM DISC Writer AE Dataflow Store Images on DICOM DISC The operation Store Images on DICOM DISC is initiated by the existence of a job production order in the build queue. Images bundled with the job will be conveyed to a DICOM DISC. Job production orders may include the following options: Data Encryption writes images in Secure DICOM File Format. Re-identification modifies patient demographic information. DISC Write Verification verifies successful creation of DISC media. Include Structured Reports retrieves associated structured reports from image source Sequencing of Real World Activities Not applicable 12

13 4.4. Query and Retrieve SCU AE Application Data Flow Diagram Functional Definitions of AE Figure 4.5 Query and Retrieve SCU AE Dataflow Query Images Query Images establishes an association with a DICOM Query/Retrieve SCP using a presentation context having a Find SOP class. A Find request is sent with user specified query fields Retrieve Images Retrieve Images establishes an association with a DICOM Query/Retrieve SCP using a presentation context having a Move SOP class. A Move request is sent for selected studies. 13

14 Sequencing of Real World Activities Figure 4.6 Example Real World Activity for Query and Retrieve SCU AE 14

15 4.5. Query and Retrieve SCP AE Application Data Flow Diagram Figure 4.7 Query and Retrieve SCP AE Dataflow Functional Definitions of AE The Query and Retrieve SCP AE accepts connections to the configured AE title s presentation address. Associations having presentation contexts with Find or Move SOP classes will be accepted Search Images Search Images is initiated by a Find request to the addressed local store. Search Images searches the host file system area assigned to the addressed local store for matches to user provided search criterion. Results are returned to the calling SCU Send Images Send Objects is initiated by a Move request to the addressed local store. Send Images initiates Store requests through the SCU AE for the image instances corresponding to the received Move request. 15

16 Sequencing of Real World Activities Figure 4.8 Example Real World Activity for SCU AE 16

17 4.6. Importer AE Application Data Flow Diagram Figure 4.9 Importer AE Dataflow Functional Definitions of AE The Importer AE is a FSR enabling the importation of DICOM part 10 files from removable DICOM disc media Import Images Import Images reads in a DICOM file set and sends Store requests to a user selected. Import Images includes the ability to re-identify patient demographic using one of the following user selected source options: Query and Retrieve SCP Modality Worklist Management SCP User-entered Values 17

18 Sequencing of Real World Activities Figure 4.10 Example Real World Activity for Importer AE 18

19 4.7. Verification AE Application Data Flow Diagram Functional Definitions of AE Figure 4.11 Verification AE Dataflow Request Verification The Verification AE acts as an SCU by sending requests with a presentation context having a Verification SOP class Accept Verification The Verification AE acts as an SCP by accepting connections for associations having presentation contexts for Verification SOP classes Sequencing of Real World Activities Figure 4.12 Example Real World Activity for Verification AE 19

20 5. AE Specifications 5.1. SCP AE SOP Classes The SCP AE provides Standard Conformance to the following SOP classes: Table 5.1 Supported SOP Classes SOP Class Name SOP Class UID SCU SCP Stored Print No Yes Hardcopy Grayscale Image No Yes Hardcopy Color Image No Yes Computed Radiography Image No Yes Digital X-Ray Image No Yes (Presentation) Digital X-Ray Image (Processing) No Yes Digital Mammography Image No Yes (Presentation) Digital Mammography Image No Yes (Processing) Digital Intra-oral X-Ray Image No Yes (Presentation) Digital Intra-oral X-Ray Image No Yes (Processing) CT Image No Yes Ultrasound Multi-frame Image No Yes MR Image No Yes Enhanced MR Image No Yes Ultrasound Image No Yes Ultrasound Image No Yes Secondary Capture Image No Yes Multi-frame Single Bit Secondary No Yes Capture Image Multi-frame Grayscale Byte Secondary No Yes Capture Image Multi-frame Grayscale Word Secondary No Yes Capture Image Multi-frame True Color Secondary No Yes Capture Image Stand-alone Overlay No Yes Stand-alone Curve No Yes 12-Lead ECG Waveform No Yes General ECG Waveform No Yes Ambulatory ECG Waveform No Yes Hemodynamic Waveform No Yes 20

21 Cardiac Electrophysiology Waveform No Yes Basic Voice Audio Waveform No Yes Stand-alone Modality LUT No Yes Stand-alone VOI LUT No Yes Grayscale Softcopy Presentation State No Yes Color Softcopy Presentation State No Yes Pseudo Color Softcopy Presentation No Yes State Blended Softcopy Presentation State No Yes X-Ray Angiographic Image No Yes X-Ray Radiofluoroscopic Image No Yes Nuclear Medicine Image No Yes Key Image Object SOP Class No Yes VL Endoscopic Image No Yes Video Endoscopic SOP Class No Yes VL Microscopic Image No Yes VL Slide No Yes VL Photographic Image No Yes Ophthalmic Photography IOD 8 Bit No Yes Image Ophthalmic Photography IOD 16 Bit No Yes Image Stereometric Relationship Image No Yes Basic Text SR No Yes Enhanced SR No Yes Comprehensive SR No Yes Key Image Object SOP Class No Yes Encapsulated PDF SOP Class No Yes Positron Emission Tomography Image No Yes Standalone PET Curve No Yes RT Image No Yes RT Dose No Yes RT Structure Set No Yes RT Beams Treatment Record No Yes RT Plan No Yes RT Brachy Treatment Record No Yes RT Treatment Summary Record No Yes 21

22 Association Establishment Policies General The DICOM standard Application context shall be specified. Application Context Name Number of Associations The SCP AE is internally limited by configuration in the number of simultaneous associations it may accept. Maximum Number of Simultaneous Associations (acceptor) 100 (default) Asynchronous Nature Multiple outstanding operations over a single association are not supported. Maximum Number of Outstanding Asynchronous Transactions Implementation Identifying Information Implementation Class UID Implementation Version Name EXPEDOSVC{x} Association Initiation by Real World Activity The SCP AE never initiates an association Association Acceptance Policy The SCP AE accepts associations from remote AEs offering valid Presentation Contexts. Figure 5.1 Receive Images Activity Accepted Presentation Contexts Note: transfer syntax support is consistent across classes. 1 {x} representing the application version number. E.g

23 23

24 Table 5.2 Accepted Presentation Contexts Abstract Syntax Transfer Syntax Role Ext. Name UID Name UID Neg. See Table 5.1 See Table 5.1 Implicit VR Little Endian SCP None Explicit VR Little Endian SCP None Explicit VR Big Endian SCP None JPEG Process 1 Baseline SCP None JPEG Process Ext SCP None JPEG Process SCP None Lossless JPEG Process SCP None Lossless SV1 JPEG Lossless SCP None JPEG Near Lossless SCP None JPEG 2000 Near Lossless SCP None JPEG SCP None MPEG SCP None Table 5.3 SCP AE C-Store Status Return Reasons Service Status Further Meaning Error Reason Code Refused Out of resources A700 Out of resources Failed Identifier Mismatch A900 Identifier/SOP Class mismatch Not Supported C001 Option is not supported on the expedo system Volume Not Found C002 Unable to find specified local store Not Responding C003 The server is not responding. Try again later Not Authorized C004 The system could not log you on Presentation Context C006 Cannot understand Missing Cancel Request Cancelled FE00 Cancelled Pending Pending FF00 Pending Success Success 0000 Success 24

25 5.2. SCU AE SOP Classes The SCU AE provides Standard Conformance to the following SOP classes: Table 5.4 Supported SOP Classes SOP Class Name SOP Class UID SCU SCP Stored Print Yes No Hardcopy Grayscale Image Yes No Hardcopy Color Image Yes No Computed Radiography Image Yes No Digital X-Ray Image Yes No (Presentation) Digital X-Ray Image (Processing) Yes No Digital Mammography Image Yes No (Presentation) Digital Mammography Image Yes No (Processing) Digital Intra-oral X-Ray Image Yes No (Presentation) Digital Intra-oral X-Ray Image Yes No (Processing) CT Image Yes No Ultrasound Multi-frame Image Yes No MR Image Yes No Enhanced MR Image Yes No Ultrasound Image Yes No Ultrasound Image Yes No Secondary Capture Image Yes No Multi-frame Single Bit Secondary Yes No Capture Image Multi-frame Grayscale Byte Secondary Yes No Capture Image Multi-frame Grayscale Word Secondary Yes No Capture Image Multi-frame True Color Secondary Yes No Capture Image Stand-alone Overlay Yes No Stand-alone Curve Yes No 12-Lead ECG Waveform Yes No General ECG Waveform Yes No Ambulatory ECG Waveform Yes No Hemodynamic Waveform Yes No Cardiac Electrophysiology Waveform Yes No Basic Voice Audio Waveform Yes No 25

26 Stand-alone Modality LUT Yes No Stand-alone VOI LUT Yes No Grayscale Softcopy Presentation State Yes No X-Ray Angiographic Image Yes No X-Ray Radiofluoroscopic Image Yes No Nuclear Medicine Image Yes No Key Image Object SOP Class Yes No VL Endoscopic Image Yes No Video Endoscopic SOP Class Yes No VL Microscopic Image Yes No VL Slide Yes No VL Photographic Image Yes No Ophthalmic Photography IOD 8 Bit Yes No Image Ophthalmic Photography IOD 16 Bit Yes No Image Stereometric Relationship Image Yes No Basic Text SR Yes No Enhanced SR Yes No Comprehensive SR Yes No Key Image Object SOP Class Yes No Encapsulated PDF SOP Class Yes No Positron Emission Tomography Image Yes No Standalone PET Curve Yes No RT Image Yes No RT Dose Yes No RT Structure Set Yes No RT Beams Treatment Record Yes No RT Plan Yes No RT Brachy Treatment Record Yes No RT Treatment Summary Record Yes No Association Establishment Policies General The DICOM standard Application context shall be specified. Application Context Name Number of Associations The SCU AE is not internally limited in the number of simultaneous associations it may initiate. Maximum Number of Simultaneous Associations (initiator) No Limit 26

27 Asynchronous Nature Multiple outstanding operations over a single association are not supported. Maximum Number of Outstanding Asynchronous Transactions Implementation Identifying Information Implementation Class UID Implementation Version Name EXPEDOSVC{x} Association Initiation by Real World Activity Figure 5.2 Send Images Activity Table 5.5 Proposed Presentation Contexts Abstract Syntax Transfer Syntax Role Ext. Name UID Name UID Neg. See Table 5.4 See Table 5.4 Implicit VR Little Endian SCU None Explicit VR Little Endian SCU None Explicit VR Big Endian SCU None JPEG Process 1 Baseline SCU None JPEG Process Ext SCU None JPEG Process SCU None Lossless JPEG Process SCU None Lossless SV1 JPEG Lossless SCU None JPEG Near Lossless SCU None JPEG 2000 Near Lossless SCU None JPEG SCU None MPEG SCU None 2 {x} representing the application version number. E.g

28 Association Acceptance Policy The SCU AE never accepts an association. 28

29 5.3. DICOM DISC Writer AE Conformance to DICOM Interchange of the Media Service DICOM DISC Writer AE supports DICOM Interchange of the Media Service. It provides standard conformance as a FSC as defined in part 10 of the DICOM standard. NOTE: The DICOM DISC Writer AE is agnostic with respect to transfer syntax as an FSC for Image classes. Image instances included in a build job production order receive no conversion/post-processing. Standard conformant application profiles are only possible if images to be written already match profile transfer syntax options. Table 5.6 Supported Application Profiles Application Real-World Activity Roles SC Option Profiles Supported STD-GEN-CD Store Images on DICOM DISC FSC Interchange STD-GEN-SEC-CD Store Images on DICOM DISC FSC Interchange STD-GEN-DVD Store Images on DICOM DISC FSC Interchange STD-GEN-SEC-DVD Store Images on DICOM DISC FSC Interchange File Meta Information Implementation Class UID Implementation Version Name EXPEDOSVC{x} Real World Activity Store Images on DICOM DISC The DICOM DISC Writer AE acts as an FSC to export SOP instances associated with DICOM DISC build jobs. The user is able to provide DISC production options that include the re-identification of patient demographics, encryption of DICOM files 4 as well as DISC verification Options DICOM DISC Writer AE supports the SOP classes and Transfer Syntaxes listed in the table below. Table 5.7 Supported IODs, SOP Classes and Transfer Syntaxes IOD SOP Class UID Transfer Syntax Transfer Syntax UID Basic Directory Explicit VR Little Endian Uncompressed Stored Print Refer to Hardcopy Grayscale Conformance Note. Image Refer to Conformance Note. 3 {x} representing the application version number. E.g Refer to the Security section of this document for DICOM conformance specifics. 29

30 Hardcopy Color Image Computed Radiography Image Digital X-Ray Image (Presentation) Digital X-Ray Image (Processing) Digital Mammography Image (Presentation) Digital Mammography Image (Processing) Digital Intra-oral X Ray Image (Presentation) Digital Intra-oral X Ray Image (Processing) CT Image Ultrasound Multiframe Image MR Image Enhanced MR Image Ultrasound Image Ultrasound Image Secondary Capture Image Multi-frame Single Bit Secondary Capture Image Multi-frame Grayscale Byte Secondary Capture Image Multi-frame Grayscale Word Secondary Capture Image 30

31 Multi-frame True Color Secondary Capture Image Stand-alone Overlay Stand-alone Curve Lead ECG Waveform General ECG Waveform Ambulatory ECG Waveform Hemodynamic Waveform Cardiac Electrophysiology Waveform Basic Voice Audio Waveform Stand-alone Modality LUT Stand-alone VOI LUT Grayscale Softcopy Presentation State X-Ray Angiographic Image X-Ray Radiofluoroscopic Image Nuclear Medicine Image Key Image Object SOP Class VL Endoscopic Image Video Endoscopic SOP Class VL Microscopic Image VL Slide VL Photographic Image Ophthalmic Photography IOD 8 31

32 Bit Image Ophthalmic Photography IOD 16 Bit Image Stereometric Relationship Image Basic Text SR Enhanced SR Comprehensive SR Key Image Object SOP Class Encapsulated PDF SOP Class Positron Emission Tomography Image Standalone PET Curve RT Image RT Dose RT Structure Set RT Beams Treatment Record RT Plan RT Brachy Treatment Record RT Treatment Summary Record 32

33 5.4. Query and Retrieve SCU AE SOP Classes The Query and Retrieve SCU AE provides Standard Conformance to the following SOP classes: Table 5.8 Supported SOP Classes SOP Class Name SOP Class UID SCU SCP Study Root Query/Retrieve Information Yes No Model Find Study Root Query/Retrieve Information Model Move Yes No Association Establishment Policies General The DICOM standard Application context shall be specified. Application Context Name Number of Associations The Query and Retrieve SCU AE is not internally limited in the number of simultaneous associations it may initiate. Maximum Number of Simultaneous Associations (initiator) No Limit Asynchronous Nature Multiple outstanding operations over a single association are not supported. Maximum Number of Outstanding Asynchronous Transactions Implementation Identifying Information Implementation Class UID Implementation Version Name EXPEDOSVC{x} 5 5 {x} representing the application version number. E.g

34 Association Initiation by Real World Activity Real World Activity Query Images Figure 5.3 Query Images Activity Table 5.9 Proposed Presentation Contexts Abstract Syntax Transfer Syntax Role Ext. Name UID Name UID Neg. Study Root Query/Retrieve Information Model Find Implicit VR Little Endian SCU None SOP Specific Conformance to C-Find SOP Class Query and Retrieve AE SCU provides standard conformance to the C-Find SOP class. Only a single information model, Study Root is supported. Table 5.10 Study Root Request Identifier for Query and Retrieve SCU AE Name Tag Study Level Patient s ID (0010,0020) Patient s Name (0010,0010) Patient s Sex (0010,0040) Study ID (0020,0010) Study Date (0008,0020) Study Accession No. (0008,0050) Study Description (0008,1030) 34

35 Real World Activity Retrieve Images Figure 5.4 Retrieve Images Activity Table 5.11 Proposed Presentation Contexts Abstract Syntax Transfer Syntax Role Ext. Name UID Name UID Neg. Study Root Query/Retrieve Information Model Move Implicit VR Little Endian Sop Specific Conformance to C-Move SOP Class Query and Retrieve AE SCU provides standard conformance to the C-Move SOP class Association Acceptance Policy The Query and Retrieve SCU AE does not accept associations SCU None 35

36 5.5. Query and Retrieve SCP AE SOP Classes The Query and Retrieve SCP AE provides Standard Conformance to the following SOP classes: Table 5.12 Supported SOP Classes SOP Class Name SOP Class UID SCU SCP Study Root Query/Retrieve Information No Yes Model Find Study Root Query/Retrieve Information Model Move No Yes Association Establishment Policies General The DICOM standard Application context shall be specified. Application Context Name Number of Associations The Query and Retrieve SCP AE is internally limited by configuration in the number of simultaneous associations it may accept. Maximum Number of Simultaneous Associations (acceptor) 100 (default) Asynchronous Nature Multiple outstanding operations over a single association are not supported. Maximum Number of Outstanding Asynchronous Transactions Implementation Identifying Information Implementation Class UID Implementation Version Name EXPEDOSVC{x} Association Initiation by Real World Activity The Query and Retrieve SCP AE never initiates an association Association Acceptance for Real World Activity The Query and Retrieve SCP AE accepts associations from remote AEs offering valid Presentation Contexts. 6 {x} representing the application version number. E.g

37 Figure 5.5 Search Images and Send Images Accepted Presentation Contexts Table 5.13 Accepted Presentation Contexts Abstract Syntax Transfer Syntax Role Ext. Name UID Name UID Neg. See Table See Table Implicit VR Little Endian SCP None Explicit VR Little Endian SCP None Explicit VR Big Endian SCP None JPEG Process 1 Baseline SCP None JPEG Process Ext SCP None JPEG Process SCP None Lossless JPEG Process SCP None Lossless SV1 JPEG Lossless SCP None JPEG Near Lossless SCP None JPEG 2000 Near Lossless SCP None JPEG SCP None MPEG SCP None 37

38 Table 5.14 Study Root Request Identifier for Query and Retrieve SCP AE Name Tag Types of Matching Study Level Patient s ID (0010,0020) S, U, W Patient s Name (0010,0010) S, U, W Patient s DOB (0010,0030) S, U Patient s Sex (0010,0040) S, U Study UID (0020,000D) S, U Study ID (0020,0010) S, U Study Date (0008,0020) R, U Study Accession No. (0008,0050) S, U, W Study Description (0008,1030) S, U, W Legend: R= Range; S = Single Value; U = Universal; W = Wild Card NOTE: Wild card matching does not support the OR ( \ ) operator. Patient name matching does not support the caret ( ^ ) operator. Table 5.15 Query and Retrieve SCP AE Status Return Reasons Service Status Further Meaning Error Reason Code Refused Out of resources A700 Out of resources Move Host Unknown A801 Unknown move destination Failed Identifier Mismatch A900 Identifier/SOP Class mismatch Not Supported C001 Option is not supported on the expedo system Volume Not Found C002 Unable to find specified local store Not Responding C003 The server is not responding. Try again later Not Authorized C004 The system could not log you on Data File Missing C005 File Not Found Presentation Context C006 Cannot understand Missing Cancel Request Cancelled FE00 Cancelled Pending Pending FF00 Pending Success Success 0000 Success 38

39 5.6. Importer AE Conformance to DICOM Interchange of the Media Service Importer AE supports DICOM Interchange of the Media Service. It provides standard conformance as a FSR as defined part 10 of the DICOM standard. NOTE: The Importer AE is agnostic with respect to transfer syntax as an FSR for Image classes. Conversion/post-processing of images is delegated to the SCU AE. Table 5.16 Supported Application Profiles Application Real-World Activity Roles SC Option Profiles Supported STD-GEN-CD Store Images on DICOM DISC FSR Interchange Initiation by Real World Activity Import Images The Importer AE acts as an FSR to import DICOM image instance files into the user specified remote AE Options Importer AE supports the SOP classes and Transfer Syntaxes listed in the table below. Table 5.17 Supported IODs, SOP Classes and Transfer Syntaxes IOD SOP Class UID Transfer Syntax Transfer Syntax UID Basic Directory Explicit VR Little Endian Uncompressed Stored Print Refer to Hardcopy Grayscale Conformance Note. Image Hardcopy Color Image Computed Radiography Image Digital X-Ray Image (Presentation) Digital X-Ray Image (Processing) Digital Mammography Image (Presentation) Digital Mammography Image Refer to Conformance Note. 39

40 (Processing) Digital Intra-oral X Ray Image (Presentation) Digital Intra-oral X Ray Image (Processing) CT Image Ultrasound Multiframe Image MR Image Enhanced MR Image Ultrasound Image Ultrasound Image Secondary Capture Image Multi-frame Single Bit Secondary Capture Image Multi-frame Grayscale Byte Secondary Capture Image Multi-frame Grayscale Word Secondary Capture Image Multi-frame True Color Secondary Capture Image Stand-alone Overlay Stand-alone Curve Lead ECG Waveform General ECG Waveform Ambulatory ECG Waveform Hemodynamic Waveform 40

41 Cardiac Electrophysiology Waveform Basic Voice Audio Waveform Stand-alone Modality LUT Stand-alone VOI LUT Grayscale Softcopy Presentation State X-Ray Angiographic Image X-Ray Radiofluoroscopic Image Nuclear Medicine Image Key Image Object SOP Class VL Endoscopic Image Video Endoscopic SOP Class VL Microscopic Image VL Slide VL Photographic Image Ophthalmic Photography IOD 8 Bit Image Ophthalmic Photography IOD 16 Bit Image Stereometric Relationship Image Basic Text SR Enhanced SR Comprehensive SR Key Image Object SOP Class Encapsulated PDF SOP Class Positron Emission Tomography Image 41

42 Standalone PET Curve RT Image RT Dose RT Structure Set RT Beams Treatment Record RT Plan RT Brachy Treatment Record RT Treatment Summary Record 42

43 5.7. Verification AE SOP Classes The Verification AE provides Standard Conformance to the following SOP classes: Table 5.18 Supported SOP Classes SOP Class Name SOP Class UID SCU SCP Verification Yes Yes Association Establishment Policies General The DICOM standard Application context shall be specified. Application Context Name Number of Associations The Verification AE is not internally limited in the number of simultaneous associations it may initiate. Maximum Number of Simultaneous Associations (initiator) Maximum Number of Simultaneous Associations (acceptor) No Limit 100 (default) Asynchronous Nature Multiple outstanding operations over a single association are not supported. Maximum Number of Outstanding Asynchronous Transactio ns Implementation Identifying Information Implementation Class UID Implementation Version Name EXPEDOSVC{x} 7 7 {x} representing the application version number. E.g

44 Association Initiation by Real World Activity Activity Request Verification Figure 5.6 Request Verification Activity Table 5.19 Proposed Presentation Contexts Abstract Syntax Transfer Syntax Role Ext. Name UID Name UID Neg. Verification Implicit VR Little Endian SCU None Association Acceptance for Real World Activity Accept Verification The Verification AE accepts associations from remote AEs offering valid Presentation Contexts to fulfill the Accept Verification activity. Figure 5.7 Accept Verification Activity 44

45 Accepted Presentation Contexts Table 5.20 Accepted Presentation Contexts Abstract Syntax Transfer Syntax Role Ext. Name UID Name UID Neg. Verification Implicit VR Little SCP None Endian Explicit VR Little Endian SCP None Explicit VR Big Endian SCP None JPEG Process SCP None Baseline JPEG Process Ext SCP None JPEG Process SCP None Lossless JPEG Process SCP None Lossless SV1 JPEG Lossless SCP None JPEG Near Lossless SCP None JPEG 2000 Near SCP None Lossless JPEG SCP None MPEG SCP None 45

46 6. Communication Profiles 6.1. Supported Communication Stacks DICOM Upper Layer over TCP/IP as defined by part 8 of the DICOM standard is supported TCP/IP Stack The TCP/IP stack is inherited from the underlying host operating system API The application makes use of the Windows Socket 2 interface Physical Media Support Any physical medium supported by the host operating system can be used. 46

47 7. Support of Extended Character Sets The expedo Application Suite supports the ISO_IR 100 (ISO/IEC ) character set. 47

48 8. Configuration Configuration of the expedo Application Suite may be accomplished through the Windows client or by editing the underlying XML documents Configurable Parameters Host Configuration Port number Binding address Maximum PDU size Maximum concurrent accepted connections Send/Receive buffer size Receive timeout Socket linger Socket keep-alive SCP AE AE Title Originator timeout Query and Retrieve SCU AE AE Title Query and Retrieve SCP AE AE Title Peer Configuration AE title IP address Port number 48

49 9. Security 9.1. Security Profiles The DICOM DISC Writer AE provides standard conformance to the Basic DICOM Media Security Profile Association Level Security The expedo local store is secured against an acceptable peer list Application Level Security Clients of the expedo Application Suite are secured with password protected user accounts. 49

Version 8 DICOM Conformance Statement. Version 3.04, September 2014

Version 8 DICOM Conformance Statement. Version 3.04, September 2014 Version 8 DICOM Conformance Statement Version 3.04, September 2014 1 Conformance Statement Overview The application described in this Conformance Statement VEPRO EMR Manager PACS is a collection of processes

More information

HP Medical Archive Solutions DICOM Conformance Statement. January 2007 (Third Edition) Part Number T4434-96003

HP Medical Archive Solutions DICOM Conformance Statement. January 2007 (Third Edition) Part Number T4434-96003 HP Medical Archive Solutions DICOM Conformance Statement January 2007 (Third Edition) Part Number Copyright 2007, 2007 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license

More information

Infinity Medical Image Server

Infinity Medical Image Server Infinity Medical Image Server DICOM Server Conformance Statement Part Number: 900-420-002 Rev. 02 Document/Software Version: v1.3.0 Date: May 12, 2009 Copyright 2008-2009 Codonics, Inc. All Rights Reserved.

More information

MiPACS Storage Server Conformance Statement Version 1.02.0.000

MiPACS Storage Server Conformance Statement Version 1.02.0.000 MiPACS Storage Server Conformance Statement Version 1.02.0.000 December 2009 Version 1.00.4.001 Conformance Statement Document Information Issued by: Medicor Imaging 1927 S. Tryon St., Suite 200 Charlotte,

More information

Technical Publication. DICOM Conformance Statement. DICOM Proxy 2.0. Document Revision 3. October 20, 2010. 2010 Copyright Brainlab AG

Technical Publication. DICOM Conformance Statement. DICOM Proxy 2.0. Document Revision 3. October 20, 2010. 2010 Copyright Brainlab AG Technical Publication DICOM Conformance Statement Document Revision 3 October 20, 2010 2010 Copyright Brainlab AG 1 Conformance Statement Overview This is a conformance statement for the Brainlab software

More information

DOLPHIN DICOM IMAGING DICOM CONFORMANCE STATEMENT

DOLPHIN DICOM IMAGING DICOM CONFORMANCE STATEMENT DOLPHIN DICOM IMAGING DICOM CONFORMANCE STATEMENT NOTICE The software described in this document has been validated in accordance with the governing DICOM standard at the time of this document's release.

More information

CARESTREAM PACS Suite (Client, Server, and CD Direct) Version 11.0. DICOM Conformance Statement

CARESTREAM PACS Suite (Client, Server, and CD Direct) Version 11.0. DICOM Conformance Statement CARESTREAM PACS Suite (Client, Server, and CD Direct) Version 11.0 DICOM Conformance Statement Publication # 8G8913 22 April 2009 Table of Contents Table of Contents...2 1 Introduction...5 1.1 Abbreviations

More information

ONIS 2.0 DICOM CLIENT. DICOM 3 Conformance statement

ONIS 2.0 DICOM CLIENT. DICOM 3 Conformance statement ONIS 2.0 DICOM CLIENT DICOM 3 Conformance statement Table of Contents 0 Introduction...4 0.1 Scope...4 0.2 Standards...4 0.3 Intended Audience...4 0.4 Important Remarks...4 0.5 Definitions...4 1 Implementation

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement CARESTREAM Vue PACS v11.3.2.4 Lesion Management and Bookmark Applications Part # 6K4188 2012-07-02 PAGE 1 of 142 Table of Contents 1 INTRODUCTION... 4 1.1 ABBREVIATIONS AND

More information

ClearCanvas ImageServer DICOM Conformance Statement

ClearCanvas ImageServer DICOM Conformance Statement ClearCanvas ImageServer DICOM Conformance Statement Document Version: 2.2 Product Name(s): ClearCanvas ImageServer Release: 11.0 Date: January 12, 2014 ClearCanvas Inc. 1920 439 University Ave. Toronto,

More information

MammoView 1.5. DICOM Conformance Statement 1.0. medigration GmbH All rights reserved

MammoView 1.5. DICOM Conformance Statement 1.0. medigration GmbH All rights reserved All rights reserved medigration GmbH, Schuhstr. 30, 91052 Erlangen Tel: +49 (0) 9131/69087-40, Fax: +49 (0) 9131/69087-50 www.medigration.de Copyright. All rights reserved. Table of Contens 1 Introduction...

More information

DICOM Conformance Statement FORUM

DICOM Conformance Statement FORUM DICOM Conformance Statement FORUM Version 3.1 Carl Zeiss Meditec AG Goeschwitzerstraße 51-52 07745 Jena Germany www.meditec.zeiss.com Document: DICOM Conformance Statement_FORUM_3.1.doc Page 1 of 25 1

More information

g GE Medical Systems Advantage Cluster Storage / Archive System Release 1 v1.1.5.2 Conformance Statement Direction number: 2160628 Revision: 2

g GE Medical Systems Advantage Cluster Storage / Archive System Release 1 v1.1.5.2 Conformance Statement Direction number: 2160628 Revision: 2 g GE Medical Systems Advantage Cluster Storage / Archive System Release 1 v1.1.5.2 Conformance Direction number: 2160628 Revision: 2 Date: September 20, 1996 Revision History Revision Date Author Reason

More information

Dx MM DICOM 3.0 Conformance Statement

Dx MM DICOM 3.0 Conformance Statement Dx MM DICOM 3.0 Conformance Statement NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL Pascal Gilbert-Jeantet

More information

DICOM Conformance Statement

DICOM Conformance Statement This printed copy is not subject to any change control XXXXXXXXXXXXxxXXXXXXXXXXXXXXXXXXX MR 2013-03-14 Siemens AG 2013 All rights reserved Siemens AG Healthcare Sector, Henkestr. 127, D-91050 Erlangen,

More information

AGFA HEALTHCARE DICOM Conformance Statement

AGFA HEALTHCARE DICOM Conformance Statement Page 1 of 79 AGFA HEALTHCARE DICOM Conformance Statement IMPAX 6.5 Solution Document No. 001310 Revision: 1.1 When printed, this is NOT a controlled document. Page 2 of 79 Document Information Service-related

More information

DigitizingStation. DICOM V3.0 Conformance Statement

DigitizingStation. DICOM V3.0 Conformance Statement DigitizingStation DICOM V3.0 Conformance Statement Copyright 2004 by image diagnost GmbH Page 1 of 17 Image Diagnost International GmbH Reproduction of this document without prior written approval is prohibited.

More information

DICOM 3.0 Conformance Statement

DICOM 3.0 Conformance Statement Picture Archiving and Communication System DICOM 3.0 Conformance Statement CODE NO.1245 Manufacturer: 1 Sakura-machi, Hino-shi Tokyo 191-8511, Japan Important Notes Konica Minolta Medical & Graphic, Inc.

More information

DICOM Conformance Statement CBS Images and Worklist Version 2.01

DICOM Conformance Statement CBS Images and Worklist Version 2.01 DICOM Conformance Statement CBS Images and Worklist Version 2.01 Compulink Inc. 1100 Business Center Circle Thousand Oaks, CA 91320 Internal document number: 4226-000-000-001 rev 1 Creation Date: 20131101

More information

DICOM CONFORMANCE STATEMENT FOR ZIOSTATION 2.0

DICOM CONFORMANCE STATEMENT FOR ZIOSTATION 2.0 DICOM CONFORMANCE STATEMENT FOR ZIOSTATION 2.0 DICOM Conformance Statement, Ziostation 2.0 1 Copyright 2006-2011, Ziosoft, Inc. 0 DICOM CONFORMANCE STATEMENT OVERVIEW 4 0.1 APPLICATION DATA FLOW... 5 0.2

More information

Technical Publications

Technical Publications Technical Publications Direction DOC0708777 Revision 3 Centricity Enterprise Archive V4.0 DICOM CONFORMANCE STATEMENT Copyright 2011 by General Electric Company 1 CONFORMANCE STATEMENT OVERVIEW The Enterprise

More information

AquariusNET DICOM Conformance Statement. DICOM Conformance Statement. AquariusNET 4.4. Rev. 12.03.2015 B

AquariusNET DICOM Conformance Statement. DICOM Conformance Statement. AquariusNET 4.4. Rev. 12.03.2015 B DICOM Conformance AquariusNET 4.4 Rev. 12.03.2015 B 1 1 Conformance Overview The AquariusNET server is a 2D/ 3D enterprise thin client-server solution. This central 3D processing server streams real-time

More information

DICOM CONFORMANCE STATEMENT FOR ZIOCUBE 1.0

DICOM CONFORMANCE STATEMENT FOR ZIOCUBE 1.0 DICOM CONFORMANCE STATEMENT FOR ZIOCUBE 1.0 DICOM Conformance Statement, ZioCube 1.0 1 Ziosoft, Inc. 0 DICOM CONFORMANCE STATEMENT OVERVIEW 4 0.1 APPLICATION DATA FLOW...5 0.2 FUNCTIONAL DEFINITION OF

More information

DICOM Conformance Statement Merge Eye Care PACS v. 4.0

DICOM Conformance Statement Merge Eye Care PACS v. 4.0 DICOM Conformance Statement Merge Eye Care PACS v. 4.0 Merge Healthcare 900 Walnut Ridge Drive Hartland, WI 53029 USA 877.44.MERGE 2012 Merge Healthcare. The information contained herein is confidential

More information

DICOM Conformance Statement

DICOM Conformance Statement Inter Medical Medizintechnik GmbH Daimlerstr. 34-36 D-32312 Lübbecke Tel. (0 57 41) 23 59-0 Fax (0 57 41) 23 59-10 E-Mail Contact @Intmed.de www.intmed.de Doc. Rev. 1 GammaXP DICOM Conformance Statement

More information

Medflow Imaging DICOM Server

Medflow Imaging DICOM Server DICOM Server version 7.6.2 Revision 2.0 Copyright 2011 Medflow, Inc. Revision History Date June 14, 2011 August 30, 2011 Rev Description 7.6.1 First version. 7.6.2 Revised to reflect version 7.6.2 changes

More information

DICOM Conformance Statement For Diagnostic Review Workstation Software Version 5-x MAN-00546

DICOM Conformance Statement For Diagnostic Review Workstation Software Version 5-x MAN-00546 DICOM Conformance Statement For Diagnostic Review Workstation Software Version 5-x MAN-00546 SecurView DX DICOM Conformance Statement Part Number MAN-00546 Revision 001 For Software version 5-X Service

More information

Candelis, Inc. DICOM Conformance Statement. ImageGrid Storage Server

Candelis, Inc. DICOM Conformance Statement. ImageGrid Storage Server 18821 Bardeen Ave. Irvine, CA 92612 Phone: 800.800.8600 Fax: 949.752.7317 Candelis, Inc. DICOM Conformance Statement ImageGrid Storage Server 0 INTRODUCTION ImageGrid Storage Server is a complete hardware/software,

More information

GE PACS Conformance Statement for DICOM v3.0

GE PACS Conformance Statement for DICOM v3.0 g GE Medical Systems Technical Publications IIS P/N 4361668 Revision 01 GE PACS Conformance Statement for DICOM v3.0 Copyright 1998 By General Electric Company g GE Medical Systems GE Medical Systems,

More information

DICOM Conformance Statement. Version: 1.0

DICOM Conformance Statement. Version: 1.0 DICOM Conformance Statement Version: 1.0 Table of Contents 1 Preface...4 2 Overview...5 3 Introduction...5 3.1 Revision History...5 3.2 Audience...5 3.3 Remarks...6 3.4 Definitions, Terms and Abbreviations...6

More information

DICOM Conformance Statement. DICOMscope 3.5. Software developed by: M. Eichelberg 1, K. Kleber 2, J. Riesmeier 1, A. Schröter 2, A.

DICOM Conformance Statement. DICOMscope 3.5. Software developed by: M. Eichelberg 1, K. Kleber 2, J. Riesmeier 1, A. Schröter 2, A. DICOM Conformance Statement DICOMscope 3.5 Software developed by: M. Eichelberg 1, K. Kleber 2, J. Riesmeier 1, A. Schröter 2, A. Thiel 1 Organizational support: J. Holstein 2, H. Oosterwijk 3 1) Kuratorium

More information

Technical Publications

Technical Publications g GE Healthcare Technical Publications Direction 5357330-1EN (DOC1498472) Revision 3 Xeleris 3.0 and Xeleris 3.1 DICOM CONFORMANCE STATEMENT Copyright 2014 by General Electric Co. Do not duplicate g GE

More information

Varian System Server. DICOM Conformance Statement

Varian System Server. DICOM Conformance Statement Varian System Server DICOM Conformance Statement P/N VA8005D3CS July 2007 General Information Abstract This document provides information about the DICOM Conformance of the Varian System Server product

More information

Hologic Physician s Viewer 7.0 DICOM Conformance Statement

Hologic Physician s Viewer 7.0 DICOM Conformance Statement Hologic Physician s Viewer 7.0 DICOM Conformance Statement MAN-02386 REV 001 Page 1 of 32 1. Conformance Statement Overview This document is the DICOM Conformance Statement for Hologic Physician s Viewer,

More information

Technical Publications

Technical Publications g GE Healthcare Technical Publications Direction DOC1486636 Revision 2 Optima CT Dicom Conformance Statement for DICOM * Refer to section 1 for a list of products in the Optima CT families to which this

More information

DICOM Conformance Statement

DICOM Conformance Statement Date: 2010-10-7 DICOM Conformance Statement Stratus OCT Instrument and Review Software Version 7.0 Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin, CA 94568 USA www.meditec.zeiss.com Document: DICOM_Conformance_Statement_Stratus_7.0.doc

More information

DICOM Conformance Statement

DICOM Conformance Statement DICO Conformance Statement IDS5 11.4; IDS7, Sectra Healthcare Server, WISE, ImageServer/s, ImageServer/xd Version 12.2.3, June 2010 About this document Sectra Imtec AB, Sweden, 2010 Disclaimer Sectra Imtec

More information

DICOM CONFORMANCE STATEMENT STORAGE SCU, Q/R SCP, PRINT SCU & STORAGE COMMITMENT SCU FOR TOSHIBA SUPERCONDUCTING MRI SYSTEMS (MIIMR0001EAB)

DICOM CONFORMANCE STATEMENT STORAGE SCU, Q/R SCP, PRINT SCU & STORAGE COMMITMENT SCU FOR TOSHIBA SUPERCONDUCTING MRI SYSTEMS (MIIMR0001EAB) DICOM CONFORMANCE STATEMENT STORAGE SCU, Q/R SCP, PRINT SCU & STORAGE COMMITMENT SCU FOR TOSHIBA SUPERCONDUCTING MRI SYSTEMS FLEXART-series/VISART-series/ EXCELART-series/SECOND CONSOLE (MIIMR0001EAB)

More information

DICOM 3.0 CONFORMANCE STATEMENT

DICOM 3.0 CONFORMANCE STATEMENT DICOM 3.0 CONFORMANCE STATEMENT JETStream Workspace Version 1.0 9705-0067, Rev A October, 004 Copyright Statement Philips Medical Systems has taken care to ensure the accuracy of this document. However,

More information

DICOM Conformance Statement

DICOM Conformance Statement Date: 2014-12-18 DICOM Conformance Statement CIRRUS TM HD-OCT 5000 and 500 Instrument Version 7.5/8.0 Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin, CA 94568 USA www.meditec.zeiss.com Document: DICOM_Conformance_Statement_CIRRUS_7.5_8.0.Docx

More information

Technical Publications

Technical Publications GE Healthcare Technical Publications Direction 5720690-1EN Revision 1 AW Server 3.2 CONFORMANCE STATEMENT for DICOM do not duplicate Copyright 2015 By General Electric Co. THIS PAGE LEFT INTENTIONALLY

More information

Philips Medical Systems DICOM Conformance Statement

Philips Medical Systems DICOM Conformance Statement Philips Medical Systems DICOM Conformance Statement DSI Pro 1.0 Document Number 4522 164 07221 20 February 2001 Copyright Philips Medical Systems Nederland B.V. 2001 Page ii DICOM Conformance Statement

More information

SwissVision TR4000. DICOM Conformance Statement File Media Storage Services. Program Version 9.3 or later Document Revision 1.2.

SwissVision TR4000. DICOM Conformance Statement File Media Storage Services. Program Version 9.3 or later Document Revision 1.2. SwissVision TR4000 DICOM Conformance Statement File Media Storage Services Program Version 9.3 or later Document Revision 1.2 Date: 22-Mar-06 SHD_15_121_415_12_E Page I Document Revision History Version

More information

Xeleris 2.0 Conformance Statement for DICOM V3.0

Xeleris 2.0 Conformance Statement for DICOM V3.0 g GE Healthcare Technical Publications DIRECTION 5168972-100 Revision 2 Xeleris 2.0 Conformance Statement for DICOM V3.0 Document Structure Information: The DICOM Print Services for Xeleris are defined

More information

Technical Publications

Technical Publications g GE Healthcare Technical Publications Direction 1007228 Revision 0 Navigation Plus System Version 5.2 For DICOM Copyright 2004 by General Electric Co. Do not duplicate THIS PAGE LEFT INTENTIONALLY BLANK

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 119: Frame Level Retrieve SOP Classes

Digital Imaging and Communications in Medicine (DICOM) Supplement 119: Frame Level Retrieve SOP Classes Page i 5 Digital Imaging and Communications in Medicine (DICOM) Supplement 119: Frame Level Retrieve SOP Classes 10 15 20 Prepared by: Working Group 6 DICOM Standards Committee, Working Group 6 1300 N.

More information

Printlink5-ID_IV. DICOM 3.0 Conformance Statement PRINT MANAGEMENT SYSTEM CODE NO. 1118. Manufacturer:

Printlink5-ID_IV. DICOM 3.0 Conformance Statement PRINT MANAGEMENT SYSTEM CODE NO. 1118. Manufacturer: PRINT MANAGEMENT SYSTEM Printlink5-ID_IV DICOM 3.0 Conformance Statement CODE NO. 1118 Manufacturer: 2970 Ishikawa-machi, Hachioji-shi Tokyo 192-8505 Japan DICOM Conformance Statement Important Notes Konica

More information

DICOM Conformance Statement

DICOM Conformance Statement Philips Medical Systems DICOM Conformance Statement Integris Systems with High Speed DICOM Image Interface MCV 2974 MCV 3621 Cardiac DICOM XA MCV 3761 Vascular DICOM XA MCV 3031 DICOM RIS Interface and

More information

DICOM. Conformance Statement. Envisor Software Version C.0

DICOM. Conformance Statement. Envisor Software Version C.0 DICOM Conformance Statement Envisor Software Version C.0 COPYRIGHT KONINKLIJKE PHILIPS ELECTRONICS N.V. 2005. ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM

More information

Digital Imaging and Communications in Medicine (DICOM) Part 4: Service Class Specifications

Digital Imaging and Communications in Medicine (DICOM) Part 4: Service Class Specifications Digital Imaging and Communications in Medicine (DICOM) Part 4: Service Class Specifications Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn, Virginia 22209 USA Copyright

More information

AGFA MEDICAL IMAGING DICOM Conformance Statement

AGFA MEDICAL IMAGING DICOM Conformance Statement MED/HB/000405 Page 1 of 19 AGFA MEDICAL IMAGING DICOM Conformance Statement ADC PRID - Software Version 1.1.09 SCU Worklist Management Page 2 of 19 MED/HB/000405 18 September, 2001 Agfa Medical Imaging

More information

DICOM Conformance Statement

DICOM Conformance Statement Document Number: 67923 Revision: B Date: 2009-01-15 Author: Sonia Yu DICOM Conformance Statement Cirrus HD-OCT Instrument and Review Software Version 4.0 Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin,

More information

Technical Publications

Technical Publications g GE Healthcare Technical Publications Direction DOC0855383 Revision 2 Centricity TM RIS-i MedoraCom 4.2 Plus Copyright 2011 by General Electric Co. Do not duplicate REVISION HISTORY REV DATE REASON FOR

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement Page 1 of 14 1 Introduction... 3 2 Quick Summary... 4 3 Storing Studies... 6 3.1 Ideal Store scenario...6 3.2 Non-ideal scenarios...6 3.2.1 Accession number...7 3.2.2 No indication

More information

Table of Contents. Version History

Table of Contents. Version History Table of Contents 1. Introduction... 1 2. Implementation Model... 1 2.1 Application Data Flow Diagram... 1 2.2 Functional Definition of AE s... 2 2.3 Sequencing of Real World Activities... 2 3. AE Specifications...

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement IntelliSpace Breast R3.1 Multi-modality features powered by IntelliSpace Clinical Applications R9.1V7 Koninklijke Philips Electronics N.V. 2013 All rights are reserved. Issued

More information

GENIE Acquisition R3.1 Conformance Statement for DICOM v3.0

GENIE Acquisition R3.1 Conformance Statement for DICOM v3.0 Technical Publications Direction 2358711-100 Revision 0 GENIE Acquisition R3.1 Conformance Statement for DICOM v3.0 This document applies to the following systems: Millennium MPR/MPS, MG and MC Optima

More information

Understanding Digital Modalities: System Integration and Use

Understanding Digital Modalities: System Integration and Use Understanding Digital Modalities: System Integration and Use Donald J. Peck, PhD Henry Ford Health System Detroit, MI donaldp@rad.hfh.edu Dicom Digital Imaging and Communications in Medicine Part 3: Information

More information

How To Write A Dicom Dicoma Dicomm Test Article

How To Write A Dicom Dicoma Dicomm Test Article Technical Publications Direction 2183325 100 Revision 0, March 27, 1997 GENIE Processing & Review System, R1.7 DICOM 3.0 Conformance Statement Document Structure Information: The DICOM Print Services for

More information

HDI 4000 Ultrasound System

HDI 4000 Ultrasound System HDI 4000 Ultrasound System DICOM Conformance Statement Rev 1.0 Philips Medical Systems HDI 4000 DICOM Conformance Rev. 1.0 12/17/2001 Philips Medical Systems Table of Contents 0. Introduction...3 0.1 DICOM

More information

DICOM CONFORMANCE STATEMENT

DICOM CONFORMANCE STATEMENT Technical Publications Revision 3 Reporting Tool 2.7 DICOM CONFORMANCE STATEMENT Copyright 2005-2010 by General Electric Co. Do not duplicate Page 1 of 34 REVISION HISTORY Revision Date Reason for Change

More information

Centricity TM RISi DICOM Conformance Statement

Centricity TM RISi DICOM Conformance Statement Technical Publications Direction No 2118780 Release 3.12 and 4.2 - General Electric Company - All rights reserved. Table of Contents 1 Introduction 4 1.1 Overview 4 1.2 OVERALL DICOM CONFORMANCE STATEMENT

More information

DICOM CONFORMANCE STATEMENT

DICOM CONFORMANCE STATEMENT g GE Healthcare Technical Publications Direction 2067192-001 Revision 4 Universal Viewer* Web Client Version 5.0 SP5 * Trademark of General Electric Company Copyright 2014 by General Electric Co. Do not

More information

Supplement 113 Email Transport

Supplement 113 Email Transport Digital Imaging and Communications in Medicine (DICOM) Supplement 113 Email Transport Prepared by: DICOM Standards Committee, Working Group 1300 N. 17th Street Suite 175 Rosslyn, Virginia 09 USA VERSION:

More information

DICOM Conformance Statement

DICOM Conformance Statement Document Number: CG-S2F-MS-039 Revision: 1.0 Date: 2011-05-31 DICOM Conformance Statement FORUM LINK net Version 1.0 Carl Zeiss Meditec AG Göschwitzer Strasse 51-52 07745 Jena Germany www.meditec.zeiss.com

More information

DICOM Correction Proposal

DICOM Correction Proposal DICOM Correction Proposal STATUS Assigned Date of Last Update 20165/01/08 Person Assigned Submitter Name Harry Solomon Harry Solomon Submission Date 2015/09/21 Correction Number CP-1550 Log Summary: Refactor

More information

Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview

Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn, Virginia 22209 USA Copyright

More information

Centricity Enterprise Web 3.0 DICOM Conformance Memo DOC0094970

Centricity Enterprise Web 3.0 DICOM Conformance Memo DOC0094970 DOC0094970 CONTENTS 1 Introduction... 3 1.1 Scope and Purpose... 3 1.2 Intended Audience... 3 1.3 Scope and Field of Application... 3 1.4 References... 4 1.5 Definitions... 4 1.6 Symbols and Abbreviations...

More information

PARCA Certified PACS Interface Analyst (CPIA) Requirements

PARCA Certified PACS Interface Analyst (CPIA) Requirements PARCA Certified PACS Interface Analyst (CPIA) Requirements Copyright notice: Copyright 2005 PACS Administrators in Radiology Certification Association (PARCA). All rights reserved. All rights reserved.

More information

How To Connect Ifa Dicom To An Ophthalmology System

How To Connect Ifa Dicom To An Ophthalmology System High Level Health IT (HIT) Standards for Ophthalmologists worldwide DICOM : the comprehensive ifa Solutions (Digital Imaging and Communication in Medicine) 1 1 2 3 4 5 6 7 8 Overview Introduction and DICOM

More information

DICOM Conformance Statement. Veradius Unity

DICOM Conformance Statement. Veradius Unity DICOM Conformance Statement Veradius Unity Koninklijke Philips Electronics N.V. 2014 All rights are reserved. Document Number: ICAP-PF.0008674 Issued by: Philips Healthcare Philips Nederlands Best P.O.

More information

DICOM Digital Imaging and Communications in Medicine

DICOM Digital Imaging and Communications in Medicine DICOM Digital Imaging and Communications in Medicine INF5081 / Vårsemester 2007 Wolfgang Leister Reidar Øksnevad Pedro Cruz G. April 2007 PACS PACS = Picture Archive and Communication System Archive for

More information

What s New in DICOM. DICOM Workshop @ SPIE MEDICAL IMAGING February 2010. Bas Revet, Philips Healthcare (Chair WG 6)

What s New in DICOM. DICOM Workshop @ SPIE MEDICAL IMAGING February 2010. Bas Revet, Philips Healthcare (Chair WG 6) What s New in DICOM DICOM Workshop @ SPIE MEDICAL IMAGING February 2010 Bas Revet, Philips Healthcare (Chair WG 6) DICOM is the International Standard for Medical Imaging and related information: images,

More information

DICOM Conformance Statement. GDxPRO

DICOM Conformance Statement. GDxPRO Document Number: 2660021133317 Revision: D Date: 01/20/2010 Author: Vidya Kulkarni DICOM Conformance Statement GDxPRO GDxPRO Instrument Software Version 1.1 GDxPRO Review Software Version 1.0 Carl Zeiss

More information

DICOM: Definitions and Testing

DICOM: Definitions and Testing DICOM: Definitions and Testing Bruce Curran University of Michigan (AAPM Representative, DICOM WG-7 Walter R. Bosch Advanced Technology Consortium Washington University of St. Louis Acknowledgements Sam

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 23: Structured Reporting Storage SOP Classes

Digital Imaging and Communications in Medicine (DICOM) Supplement 23: Structured Reporting Storage SOP Classes Page 1 4 Digital Imaging and Communications in Medicine (DICOM) Supplement 23: Structured Reporting Storage SOP Classes 8 12 16 20 Status: Letter Ballot Text, 29 October, 1999 24 DICOM Standards Committee

More information

DICOM CONFORMANCE STATEMENT

DICOM CONFORMANCE STATEMENT Technical Publications Revision 2 Reporting Tool DICOM CONFORMANCE STATEMENT Copyright 2005-2009 by General Electric Co. Do not duplicate Page 1 of 31 REVISION HISTORY Revision Date Reason for Change A

More information

Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange

Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn,

More information

IHE Radiology Technical Framework Supplement. Web-based Image Capture (WIC) Draft for Public Comment

IHE Radiology Technical Framework Supplement. Web-based Image Capture (WIC) Draft for Public Comment Integrating the Healthcare Enterprise 5 IHE Radiology Technical Framework Supplement 10 Web-based Image Capture (WIC) 15 Draft for Public Comment 20 Date: February 19, 2015 Author: IHE Radiology Technical

More information

NETWORK MANAGEMENT FOR PICTURE ARCHIVING AND COMMUNICATION SYSTEMS

NETWORK MANAGEMENT FOR PICTURE ARCHIVING AND COMMUNICATION SYSTEMS NETWORK MANAGEMENT FOR PICTURE ARCHIVING AND COMMUNICATION SYSTEMS by Edlic Nga-Lik Yiu B.A.Sc., Simon Fraser University, 2000 Edwood Nga-Wood Yiu B.A.Sc., Simon Fraser University, 2000 PROJECT SUBMITTED

More information

Cenova Image Analytics Server DICOM Conformance Statement

Cenova Image Analytics Server DICOM Conformance Statement breast imaging solutions DICOM Standard Interface Cenova Image Analytics Server DICOM Conformance Statement Software Version 2.3 MAN-03715 rev 001 Cenova Image Analytics Server 2.3 DICOM Conformance Statement

More information

Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange

Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn,

More information

NEMA Standards Publication PS 3 Supplement 41. Digital Imaging and Communications in Medicine (DICOM) Digital Signatures

NEMA Standards Publication PS 3 Supplement 41. Digital Imaging and Communications in Medicine (DICOM) Digital Signatures NEMA Standards Publication PS 3 Supplement 1 Digital Imaging and Communications in Medicine (DICOM) Digital Signatures Status: Final Text Sep 001 Prepared by DICOM Standards Committee, Working Group 1

More information

DICOM Conformance Statement

DICOM Conformance Statement Revision: 1.0 Date: Sep, 15th 2015 DICOM Conformance Statement VISUCAM 224 and VISUCAM 524 Version 6.0 Carl Zeiss Meditec AG Goeschwitzer Strasse 51-52 07745 Jena Germany www.zeiss.com/med Document: DICOM_Conformance_Statement_VISUCAM_224_524_6.0.doc

More information

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT RADIATION DOSE REPORT FROM DICOM Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT Patient comes out... Patient goes in... Big Black Box Radiology

More information

Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview

Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn, Virginia 22209 USA Copyright

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 44: Clarification of network addressing

Digital Imaging and Communications in Medicine (DICOM) Supplement 44: Clarification of network addressing 1 2 3 4 5 Digital Imaging and Communications in Medicine (DICOM) 6 7 8 Supplement 44: Clarification of network addressing and the retirement of non-tcp/ip communication. 9 10 11 12 13 14 15 16 17 18 VERSION:

More information

ConnectPro for CT/i 4.0 Systems Conformance Statement for DICOM v3.0

ConnectPro for CT/i 4.0 Systems Conformance Statement for DICOM v3.0 Technical Publications Direction 2210573-100 Revision 0 ConnectPro for CT/i 4.0 Systems Conformance Statement for DICOM v3.0 Copyright 1998 by General Electric Company GE Medical Systems: Telex 3797371

More information

DICOM Conformance Statement Print Management Service Class FUJI NETWORK PRINT SERVER FN-PS551

DICOM Conformance Statement Print Management Service Class FUJI NETWORK PRINT SERVER FN-PS551 DICOM Conformance Statement Print Management Service Class FUJI NETWORK PRINT SERVER FN-PS55 October 006 5th Edition Copyright FUJIFILM Corporation, Japan 897N00094A (006-03-40) 006.0 Revision History

More information

Digital Imaging and Communications in Medicine (DICOM) Supplement 30: Waveform Interchange

Digital Imaging and Communications in Medicine (DICOM) Supplement 30: Waveform Interchange Digital Imaging and Communications in Medicine (DICOM) Supplement 30: Waveform Interchange DICOM Standards Committee, Working Group 1 - Cardiac and Vascular Information 1300 N. 17 th Street, Suite 1847

More information

DICOM Conformance Statement

DICOM Conformance Statement Carestream DryView 5700 Laser Imager DICOM Conformance Statement June 15, 2011 Document # 8J5397 PAGE 1 of 40 This publication is protected by Federal Copyright law, with all rights reserved. Note: Publication

More information

SIGNA PROFILE CONFORMANCE STATEMENT

SIGNA PROFILE CONFORMANCE STATEMENT Technical Publications Direction 2174981 Revision 1.0 SIGNA PROFILE CONFORMANCE STATEMENT for DICOM v3.0 (ID/Net v3.0) sm - Service Manual do not duplicate Copyright 1996 by General Electric Company blank

More information

DICOM Conformance Statement. CT Tomoscan M/EG/EG Compact Release 4.0. Document Number 4522 220 59691 30 March 2000

DICOM Conformance Statement. CT Tomoscan M/EG/EG Compact Release 4.0. Document Number 4522 220 59691 30 March 2000 Philips Medical Systems DICOM Conformance Statement CT Tomoscan M/EG/EG Compact Release 4.0 Document Number 4522 220 59691 30 March 2000 Copyright Philips Medical Systems Nederland B.V. 2000 Philips Medical

More information

OpenEMR: Achieving DICOM Interoperability using Mirth

OpenEMR: Achieving DICOM Interoperability using Mirth OpenEMR: Achieving DICOM Interoperability using Mirth A ViSolve, Inc. Technical Guide TABLE OF CONTENTS Table of Contents 1. Objective... 3 2. DICOM Images... 3 3. DICOM Image Viewers... 4 4. Sending and

More information

PS3.1. DICOM PS3.1 2016c - Introduction and Overview

PS3.1. DICOM PS3.1 2016c - Introduction and Overview PS3.1 DICOM PS3.1 2016c - Introduction and Overview Page 2 PS3.1: DICOM PS3.1 2016c - Introduction and Overview Copyright 2016 NEMA DICOM PS3.1 2016c - Introduction and Overview Page 3 Table of Contents

More information

DV5950 DICOM Conformance Statement. Product: DryView 5950 Laser Imaging System

DV5950 DICOM Conformance Statement. Product: DryView 5950 Laser Imaging System DV5950 DICOM Conformance Statement Product: DryView 5950 Laser Imaging System Document # 9J5331 Author: Shobha Murthy This publication is protected by Federal Copyright law, with all rights reserved. Note:

More information

Extracting, Storing And Viewing The Data From Dicom Files

Extracting, Storing And Viewing The Data From Dicom Files Extracting, Storing And Viewing The Data From Dicom Files L. Stanescu, D.D Burdescu, A. Ion, A. Caldare, E. Georgescu University of Kraiova, Romania Faculty of Control Computers and Electronics www.software.ucv.ro/en.

More information

Introduction CDR Dicom for Windows is designed as a fully functional DICOM (Digital Imaging Communications of Medicine) based client-server

Introduction CDR Dicom for Windows is designed as a fully functional DICOM (Digital Imaging Communications of Medicine) based client-server Introduction CDR Dicom for Windows is designed as a fully functional DICOM (Digital Imaging Communications of Medicine) based client-server application. The client application can, in theory, communicate

More information

Supports screening, diagnostic, and multimodality workflows

Supports screening, diagnostic, and multimodality workflows GE Healthcare Universal Viewer Breast Imaging Product Data Sheet Supports screening, diagnostic, and multimodality workflows Introduction Centricity PACS with Universal Viewer 1 puts clinical insight within

More information

MedDream SendToPACS USER S MANUAL (version 1.15)

MedDream SendToPACS USER S MANUAL (version 1.15) MedDream SendToPACS USER S MANUAL (version 1.15) 2014, Softneta UAB, Kaunas All rights reserved in the event of granting of patents or registration as a utility patent. All names of companies and products

More information