Technical Data. Dimensions



Similar documents
Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Inductive sensor NI10-M18-Y1X-H1141

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Series 8146/5-V37 and Series 8150/5-V37

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Solenoid Valve Island Type 3965

Compact pressure switch Flameproof enclosure Ex d Model PCA

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Plug and Socket Devices CES 63 A Series 8579

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Plug and Socket Devices SolConeX 16 A Series 8570

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

SEISMIC VELOCITY TRANSDUCER T1-40

Safety instructions VEGADIS DIS81.CEIA/V****

2.12. page Products for Explosion hazardous Environment

Terminal Boxes Series 8146

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

Instructions for Safe Use

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Differential-Hall-Effect based Sensors Series A5S Overview

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Explosion proof enclosures

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Technical Information RIA14

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Terminal Box. Specifications TNCN

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Inductive sensors. Compact, fast, reliable. Edition 2013

Control and Distribution Boxes made of Stainless Steel Series 8150

Linear Luminaire with LED Series EXLUX 6402/2

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Flow switches Series AD/VH

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

A good connection. International approvals.

Flameproof Audible Signal 115 db (A) Series YA90

Plastic tube flowmeters Series PT/PS

Capacitive Prox E2K-X

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

MINI MCR-SL-R-UI(-SP)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

CAPACITIVE LEVEL METERS CLM 36

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Technical data sheet TDS0070

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Cable Plug acc. to DIN EN , Form A

type V46, solenoid or pneumatic operated

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Software and Display instruments

Relative pressure transmitter type 520

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

3/2-way Solenoid Valve, direct-acting, NC or NO

Differential-Hall-Effect based Sensors Series A5S

Worcester DS/DM Series UltraSwitch Switch box

Electric Rotary Actuator - On/Off or programmable control actuator

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Magnetic proximity switches

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Safety instructions VEGAPULS PSWL61. KX***H***

Conductive Level Switch FK 2 Technical Data:

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Safety technique. Emergency stop module BO 5988 safemaster

Cross-beam scanning system to detect slim objects. 100 mm in

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Liquid Level Limit Switch liquiphant T FTL 20

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Digital input modules

Transcription:

0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation flush Output polarity NAMUR Assured operating distance s a 0... 4.05 mm Reduction factor r Al 0.21 Reduction factor r Cu 0.18 Reduction factor r 304 0.63 Nominal ratings Nominal voltage U o 8.2 V (R i approx. 1 kω) Operating voltage U B 5... 25 V Switching frequency f 0... 500 Hz Hysteresis H 3 % Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Functional safety related parameters MTTF d 14110 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature -25... 100 C (-13... 212 F) Mechanical specifications Connection type cable PVC, 2 m Core cross-section 0.75 mm 2 Housing material Stainless steel 1.4305 / AISI 303 Sensing face PBT Degree of protection IP67 Cable Bending radius > 10 x cable diameter information Use in the hazardous area see instruction manuals Category 1G; 2G; 1D Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates FM approval Control drawing 116-0165 UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval CCC approval / marking not required for products rated 36 V Dimensions M18x1 4 40 24 1

Electrical Connection BN L+ BU L- 2

Equipment protection level Ga Device category 1G for use in hazardous areas with gas, vapour and mist II 1G Ex ia IIC T6 T1 Ga The Ex-related marking can also be printed on the Ambient temperature and in this instruction manual. The has to be observed. The special conditions must be adhered to! ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. If the Exrelated marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed. s on the metal housing components must be avoided. Dangerous electrostatic charges on the metal housing components can be avoided by incorporating these components in the equipotential bonding. 3

Equipment protection level Gb Device category 2G for use in hazardous areas with gas, vapour and mist II 1G Ex ia IIC T6 T1 Ga The Ex-related marking can also be printed on the Maximum permissible ambient temperature T amb and in this instruction manual. The has to be observed. The special conditions must be adhered to! ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. 4

Equipment protection level Da Device category 1D for use in hazardous areas with combustible dust II 1D Ex ia IIIC T135 C Da The Ex-related marking can also be printed on the Maximum permissible ambient temperature T amb and in this instruction manual. The has to be observed. ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. against the effects of impact by installing an additional enclosure. The information regarding the minimum ambient temperature for the sensor as provided in the datasheet must also be observed. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Do not attach the nameplate provided in areas where electrostatic charge can build up. 5