For heavier duty macerator/pumping applications



Similar documents
Please also see 10 golden rules for correct Saniflo installation on

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

1. Description. 2. List of Accessories included A B C F G H

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Conlift1, Conlift2, Conlift2 ph+

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

ECOCIAT. Domestic hot water heat recovery unit

DRAIN CLEANING MACHINES

MODEL INSTALLATION INSTRUCTIONS

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Drayton Digistat +2RF/+3RF

INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION. This guidance is endorsed by HHIC members.

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

The most advanced Undersink Sullage System with inbuilt controls and alarms.

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Portable Air Conditioner

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Introduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References

SF15K SF05KSS, SF10KSS

Session 2: Hot Water Supply

SunMaxx Solar Filling Station Operating Instructions

Oil and Coolant Circulating Heating System. Model - OCSM

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Operators manual Basic water heater

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Plumbing for retail food businesses

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Heating and Domestic Hot Water Systems for dwellings Achieving compliance with Part L 2008

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Your Pressure Sewerage System Guide

HEAVY DUTY STORAGE GAS

NAVIEN AMERICA INC FITCH AVENUE

6. Principles of effective plumbing systems

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

This section gives you some helpful information and tips on running your home and the equipment in it.

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Meaco 30L and Meaco 40L dehumidifier instruction manual

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

IMPORTANT SAFETY RULES TO FOLLOW

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

Residential Plumbing BCN 1058

Power consumption (kw)

ferroli Boiler Replacement Optimax HE- Modena HE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

LK Electric Boiler - 4,5

Itho Products for Hot and Boiling water. product-

LC/LCD ranges level controllers

What to Expect From the Examination. How to Study the Plumbing Codes

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

SIR INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES

Cooktop Low-Profile Ventilation Hoods

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Install a bathroom anywhere without any major construction

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

Steam System Best Practices Condensate System Piping

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Operations Manual Blast Chiller

Syphonic Roof Drainage

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

SELECTION, APPLICATION AND MAINTENANCE

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

LUCCI AIRFUSION QUEST II CEILING FAN

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

Dehumidifier D 850E. - Instruction manual version 02

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

Installation and maintenance instructions. Danfoss Vent

Thermostatic bar showers. Troubleshooting and maintenance

Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP

40 ltr Domestic Grease Trap GTO ltr Commercial Grease Trap GTO2. Rotational Moulders providing State of the Art Product Design and Developement.

Operating instructions

Element D Services Plumbing

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Cooling system components, removing and installing

CUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System

Transcription:

For heavier duty macerator/pumping applications A commercial pump for discharge of waste water from serveries, bars & canteens A heavy duty pump for discharge of hot waste water in commercial applications for pumping acidic condensate from condensing boilers High performance macerating pump discharging waste and water from multiple WC s and other appliances Macerates and pumps waste water from WC, urinals and other waste water producing items check out the website for details: www.saniflo.co.uk

INTRODUCTION The Professional Range takes Saniflo technology to a higher level and provides more opportunities for Pump Specialists. This brochure provides in-depth technical detail relating to the Professional Range of products. The Saniflo Professional Range extends the benefits of Saniflo technology from the domestic to the commercial sector which may now take advantage from the brand s quality, longevity and service support in situations where the addition of facilities is hampered by remote soil stacks or drainage. The Professional Range comprises six products that are tough enough to perform in some of the most demanding situations where it is necessary to deliver waste water over a distance of 100m or vertically to a height of 11m using small bore discharge pipework. Sanicom is the second pump in the Professional Range. It has a powerful oil and fan cooled motor encased in aluminium housing. It can pump water over a staggering 80m horizontally, 8m vertically or a lesser combination of both. It disposes of water circa 35 C but is capable of dealing with 90 C water for short periods dependent upon flow rate and discharge pipework configuration. Its high flow rate to pumping head is ideally suited to demanding commercial or industrial environments such as: waste water from large sinks; industrial glass washer/ dishwashers; sports or leisure centres where there is a combination of constantly busy showers, baths and sinks. Sanicubic is the most powerful pump in the Saniflo Professional Range. It has been designed for discharging waste from multiple WCs and other waste water producing appliances. The unit is capable of discharging waste through 50mm pipework up to 11m vertically or 100m horizontally or a lesser combination of vertical x horizontal. Sanicubic has inlet diameters of 110mm for WC waste and 40mm for waste water. The unit can handle waste water of up to 70 C for short periods and has dual motors for absolute reliability and power. There are two alarms, one unit mounted, and one remote. The remote alarm will sound whenever the main alarm sounds. The unit operates on a domestic power supply of 230/240V AC 50Hz.

Sanispeed is a pump which is intended for light commercial situations. It has a working temperature of 35 C and can operate at 75 C for short periods. Pumps up to 70m horizontally using 32mm or 40mm pipework. Its maximum discharge height is 7m with a flow rate at this height of 43 litres/ minute. It has proved extremely efficient in bar/ restaurant environments where there were previously no alternatives to traditional gravity drainage. Sanibest accepts waste and water from a WC, hand basin, shower and urinal. The unit features a high performance motor combined with a radical macerator action powerful enough to cope with the occasional sanitary item accidentally disposed of in the WC. It is the preferred unit for locations where members of the public, not necessarily familiar with macerator units, may unwittingly subject them to abuse. Sanicondens is an essential pump for the disposal of condensate from gas boilers, air conditioning units or dehumidifiers. The small but powerful unit pumps acidic condensate solutions up to 4.5m vertically at a mean temperature of 35 C, though it can cope with up to 80 C for limited periods. There are two models available: Sanicondens Plus and Sanicondens Best. Sanicondens Best incorporates a neutralising tray for the acidic concentrate from condensing boilers. Saniflo units are fully guaranteed for two years and backed by a nationwide service network. For Technical Advice and Spares call 020 8842 4040 Visit the website www.saniflo.co.uk for a full listing of Service Engineers. Service Engineer Linkline: 08457 650011 Please phone from a landline from the unit location in order to be automatically connected to your local Service Engineer 1

416 492 440 400 407.5 SANICUBIC High performance macerating pump discharging waste and water from multiple WCs and other appliances. 110mm WC inlet. 2 on top 40mm inlet 50mm outlet 110mm WC inlet. 1 each side Pumps up to 11m vertically through 50mm pipework Pumps to 100m horizontally or a lesser combination of vertical and horizontal Inlet diameter 110mm for WC waste, 40mm for waste water Handles waste water of up to 70ºC Dual motors for absolute reliability and power Two alarms one unit mounted, one remote Power supply: 230-240V AC 50Hz Domestic Supply SANICUBIC OPERATING PRINCIPLE SANICUBIC contains 2 separate pumps. Each of the pumps is fitted with a high-performance maceration system. The 2 pumps operate alternately. In the event of inflow overload, both motors run at the same time (or if one of the pumps is faulty, the other one takes over). The SANICUBIC tank is fitted with 2 dip tubes; one tube controls motor operation, and the other one controls the alarm system. - Long pickup tube (normal operation): as soon as the waste water level in the tank reaches the triggering point in the long tube, the pumping system starts up. - Short pickup tube (inflow overload operation): if the waste water level in the tank reaches the upper point, a contact is closed and the auxiliary pumping system is triggered. The contact also sets off an audible and visual alarm. The general alarm LED on the SANICUBIC control panel switches to red. The system sends a high-frequency overload signal to the remote alarm unit. The SANICUBIC is fitted with a remote alarm module that transmits a visible and audible alarm (HF link). Note: Isolating valves must be fitted with a Sanicubic installation. If isolating valves are not fitted this may make service/maintenance impossible and invalidate your warranty. These valves are available through your merchant. Waste and water drain by gravity into the Sanicubic and adequate falls must be provided DIMENSIONS AND OVERALL MEASUREMENTS 279 178 82.5 * * 557 73 Discharge pipe up: 11m along: 100m 85 15 490 76 2

SFA SFA SFA SFA TECHNICAL DATA Type..........................R300 Maximum discharge head..........11m Voltage........................220-240V Frequency......................50Hz Volume........................47 l Maximum power input.............3000w Maximum current input............13a Electrical classification............i Average water temp for optimum performance....................35 C Maximum temperature (intermittent)...70 C* Protection index.................ip67 Net weight (including accessories)...30kg *Hot water drain cycles from dishwashers or washing machines Waste from multiple WCs and other waste water producing appliances. (The combined inputs must not exceed 80% of those shown in the graph below). PERFORMANCE CURVE Height (M) 11 10 9 8 7 6 5 4 3 2 1 0 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 Flow Rate (litres/min) Example: Pump P1 is operating normally. It discharges 160 l/min at a pumping height of 5 m. If pump P1 shows any signs of weakness or if the waste water inflow is too great, pump P2 starts up. The output is then increased to about 275 l/min, until the situation returns to normal. IMPORTANT INSTALLATION SPECIFICATIONS FOR SANICUBIC 1. Attention: the space in which the SANICUBIC is to be installed must be large enough to leave at least 600 mm of working room around and above the unit to facilitate such maintenance work as may be required. There must be sufficient lighting and it must be sufficiently well ventilated and protected from freezing. 2. Isolation valves must be fitted on the 50mm discharge pipe work and on all inlet pipe work including WCs and other sources. This is required by the standard EN 12056 and to allow any possible maintenance work to be carried out without serious flooding. Note: If isolation valves are not fitted service/maintainance may be impossible and any associated costs will not be covered by the Saniflo warranty. 4 /110mm and 2 /50mm isolation valves can be purchased from your merchant when placing your order for Sanicubic. 3. The discharge pipe must be fitted so as to avoid all back flow from the drainage RATIO OF HEIGHT / LENGTH FOR DISCHARGE max 11m 10m 9m 8m 7m 6m 5m 4m 3m 2m 1m max 10 m max 20 m max 30 m max 40 m max 50 m max 60 m max 70 m max 80 m max 90 m max 100 m max 110 m OK SANICUBIC complies with standard EN 12050-1 (lift station for household waste containing faeces) and with the European directives covering construction products, electrical safety and electromagnetic compatibility This unit must be installed and used in compliance with European installation standard EN12056 and with local requirements. system. Back flow can be avoided by installing an anti-back flow riser reaching a high point above the maximum back flow level. Comment: In the absence of local information to the contrary, the maximum back flow level corresponds to street level (roadway, pavements, etc.). Continue the discharge pipework after the anti-backflow riser using a larger diameter pipe. 4. If the Sanicubic is installed in a space such as a pit for example, we would recommend the fitting of a bilge pump in case of flooding. 5. The Sanicubic must be vented with an outlet at roof level. The vent should be taken from one of the two 40mm connections located either side of the INSTALLING THE ANTI BACKFLOW LOOP The discharge pipe must be fitted so as to avoid all back flow from the drainage system. Back flow can be avoided by installing an anti-back flow riser reaching a high point above the maximum back flow level. 3

50mm discharge outlet. The Sanicubic will not be able to operate at all if this vent connection is not opened up! Do NOT fit air admittance valve on the top of the air vent pipe. The vent must be an open vent or the unit will not operate. 6. The lifting station must be fixed to the floor (see paragraph in Section 8-8 ). Alarm Operation SANICUBIC Société Française d Assainissement EN 12050-1 R300 220-240 V - 50 Hz 3000 W General Alarms High level alarm : If the water level in the unit is abnormally high: the buzzer is triggered and the red LED comes on; the other motor starts up 3 seconds later (see the illustration showing the control keyboard). Temporary alarm : If one of the 2 motors runs for more than 1 minute : the buzzer is triggered and the red alarm LED comes on; the other motor starts up 3 seconds later. Mains power supply alarm: In the event of a mains power failure (or if the unit is unplugged) : the buzzer is triggered and the red alarm LED comes on; the yellow mains power LED also flashes. Resetting General Alarms If the problem that has triggered one of the alarms referred to above ceases, the buzzer stops, but the red alarm LED stays on to memorize the fact that there has been an operational problem. The Reset alarm key on the keyboard is used to switch the buzzer off in all cases, but it only switches the red LED off if the problem that triggered the alarm has been dealt with. The alarm lights on the remote control box also stay on until the problem has been dealt with. This avoids the risk of the unit being left operational without attention being given to a potential cause for failure. The electronic system measures the current input (I a) to each motor and enables detection of 2 types of fault: - I a < I minimum threshold, which can be due to: a fault in the motor power supply (short-circuit), a capacitor fault, disconnected internal pipes (eg. through blockage) (turbine / macerator system). CONNECTING THE INLETS DN 40/50 SANICUBIC Lower inlets (dia.1) Upper inlets (dia.2) Cut off the end of the DN 50 inlet with a saw. Cut the sleeve (D) to suit the pipe diameter: DN 40 or DN 50 (dia.3). Fix the sleeve on the inlet and on the pipe, using the collars. - I a > I maximum threshold, because the macerator system is blocked. Both of these cases lead to the following results: the motor in fault status stops, the corresponding red LED comes on, the alarm is triggered and the second motor is started. If the power consumption of the second motor is also outside the limits: that motor also stops and the corresponding red LED comes on. The buzzer can be stopped by pressing the Reset alarm key, but the red motor LED stays on. When the override key for the corresponding motor is pressed the green LED comes on if the fault is no longer present. Until the override key for the motor is pressed the unit continues to operate on one motor. The override key is used to re-initialise the program. The unit then attempts to operate using both motors (alternately). GENERAL ALARMS UNIT ALARM motor 1 LED motor 1 override Ø 50 Ø 50 Ø 50mm Ø 100/110 Ø 40mm Ø 40mm CONNECTING THE DN 100/110 INLET Lower inlets (dia 1) Remove the plug from the side inlet. Fix the sleeve (F) in place using the collar (J). Fully insert the DN 100/110 tube in the other end of the sleeve and fix it in place using the other collar (J). Upper inlets (dia 2) Cut off the upper end of the DN 100 inlet with a saw. Fix the sleeve (F) in place using the collar (J). Fully insert the DN 100/110 tube in the other end of the sleeve and fix it in place using the other collar (J). Ø 100/110 Ø 100/110 4 general alarm LED motor 2 override mains LED reset general alarm REMOTE ALARM red motor 1 alarm LED Ø 50mm motor 2 LED red motor 2 alarm LED red general alarm LED yellow transmission alarm LED green mains alarm LED The remote alarm module is connected to the SANICUBIC via an HF link. It receives the various types of alarm information from the unit. USE 1 The SANICUBIC unit is designed to drain off household waste water. Any other use will invalidate the guarantee. Do not dispose of sanitary towels, condoms, hygiene articles, oils, solvents, acids, or any other potentially corrosive or explosive liquids etc, via the unit. 2 Warning! In the event of a power failure, stop draining any water from the equipment connected to the SANICUBIC unit. 3 Do not install or use the unit in a zone where there is a risk of explosion. MAINTENANCE A visual check of the lift station must be made once a month to make sure it is operating correctly, and the installation must be inspected regularly (once a year) by a qualified person. Meanwhile, if any technical problems are experienced, please call our after sales service.

SOLVING TROUBLE AT MILL High performance macerating pump discharging waste and water from multiple WC s and other appliances 110mm WC inlet. 2 on top up: 11m along: 100m ASanicubic unit has been installed in the basement of the cottage to pump waste and water to the mains, which is situated some distance away. Isolating valves are required but not included with Sanicubic 50mm outlet 40mm inlet Site manager Peter Bowler said The system seems to be working well pumping from the under croft up to a man hole at road level, this should save us 217 every ten days when the cottage is let, so thank you for your help! 110mm WC inlet. 1 each side The Arkwright Society preserves the historically important mills in Cromford site of the first successful water powered cotton spinning mill. The Arkwright society is a charity and to raise funds one of the cottages has been converted into a holiday let and exhibition. Prior to conversion the cottage which is sited on conservation land had a septic tank which was both expensive to empty and gave problems of leakage. As water purity is closely monitored the cottage needed to be connected to mains drainage and this could only be done with a Saniflo pumping system. 5

SANICOM Heavy duty pump for discharge of waste water for heavy commercial use up: 8m along: 80m Working temperature 35 C. Maximum temperature 90 C for short periods. 2 side entries (ø 40mm) Air vent / or connection to exterior Discharge pipework: ø 32mm/ ø 40mm Maximum Horizontal discharge (1:100) 80m Maximum Vertical Discharge Height 8m (or a lesser combination of both) Sanicom is a lifting pump for waste water used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance level, and is safe and reliable, provided all the rules for installation and maintenance in this notice are strictly followed. INSTALLATION FITTING The Sanicom can be fixed to the floor, preventing it from turning or moving. 1. Warning: The space in which the Sanicom is installed must be large enough to leave at least 600mm around the unit for easy maintenance. This space must be well lit, ventilated, and must never be immersed in water and must be protected from frost. 2. Isolation valves should be fitted to the inlet pipework and discharge pipework to isolate the unit in case of the need for service. I H G G H DIMENSIONS AND OVERALL MEASUREMENTS 330mm 420mm 490mm 230mm ø 60 HOW IT WORKS The Sanicom contains 1 pump. The tank is equipped with a sensor tube which controls the automatic activation of the motor when waste enters the unit. As soon as the waste enters the tank, the pump starts. PERFORMANCE CURVE Vertical Height - Metres 12 11 10 9 8 7 6 5 4 3 2 1 0 50 60 70 80 90 100 110 120 130 140 Flow Rate - litre/min 6

HEIGHT AND LENGTH OF THE DISCHARGE PIPE Max 8m max 10m 7m max 20m 6m max 30m 5m max 40m 4m max 50m 3m max 60m 2m max 70m 1m max 80m CONNECTION TO SIDE INLETS Use the flexible inlet connector (A) for side inlet connections. Using a metalwork saw, saw off the desired inlet point, remove any burrs and then fix the flexible inlet connector with the hose clip (D). We recommend the installation of a grease trap for applications with a high grease inflow. Connection to the inlet can be made using a 40mm or 50mm pipe. To make a 50mm connection, cut off the end of sleeve (A) beforehand. Application Type Maximum vertical pumping height Voltage Frequency Maximum power consumption Maximum current consumption Electrical class Protection index Commercial sink, washing machine, dishwasher or shower* or bath* FF03-P95 CONNECTION TO SOIL AND VENT PIPE OR DRAIN 8m 220 240 V 50 Hz 750 W 3.3 A I IP44 Max temp with intermittent functioning 80 Net weight 10 kg * In the case of bath or shower tray, make sure the waste traps are raised 15cm above floor level. CAUTION: 1. All applications other than those described in this notice are prohibited. 2. Do not exceed an incoming flow rate greater than 80% of the flow rate stated on the design curve in any of the apparatus. 40mm 32mm C CONNECTION TO SANITARY WARE To connect a bathtub (or shower), make sure the waste trap height is raised by at least 15cm above floor level. Connection must be made using 40mm or 50mm diameter pipework, with minimum slope of. 2.5% A D 2.5% 150mm min The disposal of waste from the Sanicom can discharged through a 32mm diameter copper or plastic pipes (or PVC, ABS, etc.). This discharge pipe must be designed so as to prevent back-flow from the sewers. See diagram above. Horizontal discharge pipework should maintain a fall (1cm/M) to the soil and vent pipe. If a vertical rise is required, this must be installed at the start of the run, before the horizontal section. The horizontal section should then have a minimum fall to the final drain point. Take care that the discharge valve flap faces the direction of flow. If the end of the discharge pipework is much lower than the unit, install a riser pipe about 80mm long from the highest point of the discharge run and fit an air admittance pipe on top (capable of withstanding at least 15psi pressure.) to break the syphon. The discharge should be connected to a 100mm discharge stack via a strap boss connector. 7

The Professional Range comprises six products specially designed for heavier duty applications. Sanicubic will discharge waste and water from multiple WCs and other waste water producing appliances Discharge pipe Hotels, restaurants, cafés, guesthouses, pubs, clubs, and bars, factories, offices, shops, laundries and nursing homes. Just a few of the demanding environments in which the Professional Range will solve plumbing problems. ELECTRICAL CONNECTION The electrical installation should be carried out by a qualified person and conform to BS 7671 1992 requirements for electrical installation. These products require a 220/240V single phase 50 Hz supply (UK specification) and should be connected to an unswitched fused wiring connector protected by a 5 amp fuse (Sanicubic 13 amp fuse), or a 30 ma circuit breaker set at 5 amp, (13 amp for Sanicubic). The unit should be sited at least 60cm away from any shower tray. GUARANTEE Saniflo units are fully guaranteed for two years and backed by a nationwide service network. 8

SANISPEED Commercial pump Working temperature 35 C maximum temperature, 75 C for short periods. Maximum Horizontal discharge ( 1:100) 70m Maximum Vertical Discharge Height: 7m (or a lesser combination of both) 2 side entries (ø 40mm) 2 cover entries (ø 40mm) Discharge pipework: ø 32mm / ø 40mm Air vent Motor power rating 450 Watts Shaft: stainless steel Impeller: single disk ø 81mm European Standard EN 12050-2 up: 7m along: 70m DESCRIPTION This unit is a pump that will clear the waste from a shower and washbasin, bath, washing machine, glass washer and a sink in a light commercial situation. PERFORMANCE CURVE DIMENSIONS AND OVERALL MEASUREMENTS Vertical Height - metres 8 7 6 5 4 3 2 1 0 20 40 60 80 100 120 Flow Rate L/min T f 3 ø 40 373 mm 314 mm 92.5 mm 185 mm 36 mm 256 mm 277 mm The discharge pipe size for Sanispeed must be 32mm. 309 mm 139.4 mm 9

INSTALLATION HEIGHT AND LENGTH OF THE DISCHARGE PIPE H H Max 7m 6m max 10m max 20m I I 5m 4m 3m max 30m max 40m max 50m 2m max 60m 1m max 70m CONNECTION TO LID INLETS G A G The unit should be accessible for possible maintenance. It is supplied with floor fixing lugs to prevent it from moving during use. If pumping vertically, always put the vertical before the horizontal at the start of the piperun. CONNECTION TO SIDE INLETS C To connect to a lid inlet, cut off the sealed cap with a hacksaw and connect using the rubber connector (A) provided. Tighter with the metal hose clips (G). G A G C DISCHARGE CONNECTION Use the rubber connector (A) for connection of pipes to the side inlets. Secure with the metal hose clips (G). Cap off unused inlets with the end caps (C) provided, after greasing the joints. CONNECTION OF BATHROOM APPLIANCES 3% To connect a shower/bath, ensure that the trap exit is 15cm above floor level. Although not obligatory, a lid connection may be used to run an external air vent. 10 3% 15 cm Note: The discharge pipework should be 32mm copper or rigid solvent weld plastic. Observe the pumping parameters of the unit (vertical and horizontal combination, step 4). All horizontal pipe runs must have a minimum fall of 1:100 (10mm per metre) all the way to the drain. Technical advice for discharge to lower floor If the discharge pipework runs to a level considerably lower than the unit, the resultant siphoning effect can suck out the water seal in the unit. Fitting an air admittance valve capable of withstanding 10psi pressure (BBA approved) at the high point of the pipe run will overcome this problem. Orient the opening end of the non-return valve in the direction of the discharge. Secure with the metal hose clip (F).

IN CASE OF SERVICING Norms The unit conforms with EN 12050-2 waste water lifting plant. SANISPEED Société Française d Assainissement EN 12050-2 FF02-V45 220-240 V - 50 Hz - 400 W - IP44 2A - 6,4 KG 3% 3% For possible service requirements, provide a drain off at the low point of the installation. Care and use The Sanispeed is designed to handle the waste evacuation from a bath, kitchen sink, dishwasher and washing machine - in a light commercial situation. Its powerful pump will deal with every day normal usage. Warning: Do not dispose of solvents, paints (do not wash paint brushes in sink), caustic, acid or other chemicals into these products. Depending on usage, the unit may need to be cleaned from time to time. Heavy usage can result in a build up of fat and grease. The unit will pump away water as hot as 75 C for a short time (i.e. to clear the hottest waste water from a washing machine). However, do not pour boiling water directly into the unit. When pumping very hot water for a prolonged period of time, the unit will automatically cut out to protect the motor (thermal cut-out). When this happens the unit will shut down long enough to cool down (approx.1 hour) and automatically resume normal operation when ready. SPEEDY ANSWER TO A DUTY-FREE PROBLEM Passenger growth has risen dramatically at East Midlands Airport over the past couple of years. 1.2m passengers used the airport in the first 3 months of 2008, a rise of 15.2% compared with the same period in 2007. Four new routes have been introduced to Goa, the Isle of Man, Palma and Warsaw. To keep up to speed with the escalating popularity the airport has undergone a major 1m refurbishment. The busy duty free shop required a new compact staff kitchen and sink in a position that, according to project supervisor, Bryn O Connor, was nowhere near any mains drains! He explained: To have used a traditional plumbing approach would have meant cutting a 20m long duct in the concrete slab to carry the waste pipe to the mains drainage. Not only would this have involved a massive cost but would have caused considerable downtime in a very busy, live passenger terminal. But as most of the terminal s internal drainage runs through the ceiling void it was decided that a Saniflo Sanispeed would be the best, most cost effective solution. Bryn said: It was possible to take the 32mm small-bore pipework up a wall and into the ceiling void. There we were able to pick up the existing waste pipe run that feeds the first floor kitchen area. This proved to be the quickest, most cost effective answer to providing an essential requirement. SANISPEED: A commercial pump for discharge of waste water from kitchen and utility rooms 11

SANIBEST Macerator Pump up: 6m along: 100m Maximum Horizontal discharge (1:100)100m Maximum Vertical Discharge Height: 6m (or a lesser combination of both) Working temperature 35 C. 2 side entries (ø 40mm) 1 cover entry (ø 40mm) Air vent Discharge pipework: ø 22/32mm Pressure chamber: membrane Starting mechanism: microswitch European Standard EN 12050-3 DIMENSIONS AND OVERALL MEASUREMENTS 175 mm 327,5 mm 530 mm 500 mm 180 mm 513 mm 275 mm DESCRIPTION Sanibest is a high performance pump/macerator for normal WC waste, toilet paper and waste water in accordance with the relevant regulations. Sanibest is suitable for heavy usage situations and will handle water for short periods at 90 C. This pump/macerator has been designed to pump away the waste from a WC and the sanitary appliances shown above. Sanibest is a robust machine which is capable of handling the occasional sanitary article accidentally flushed down the WC. Installed and used correctly, Sanibest will give consistent and reliable service. PERFORMANCE CURVE 10 9 8 7 6 EN 12050-3 5 4 3 2 1 0 0 10 20 30 40 50 60 70 80 90 100 110 120 Flow Rate - litre/min 12

HEIGHT AND LENGTH OF THE DISCHARGE PIPE CONNECTION TO A WC 6m max 20m 1 5m max 35m 4m 3m 2m max 50m max 60m max 70m A 1m max 80m 2 INSTALLATION G G 3 H H WARNING: The unit must be connected to a WC pan with a horizontal outlet spigot conforming to EN33 or EN37 norms. The unit should be installed so that it is accessible for possible maintenance. The unit can be fixed to the floor to prevent it from moving or turning. CONNECTION OF THE OTHER SANITARY APPLIANCES Pull flexible sleeve over the pan spigot (fig 1) Position the jubilee clip over the edge of the flexible sleeve (fig 2), and tighten with a screwdriver (fig 3). 1 2 D C E 3 Closed To connect to the side entries of the case, use the rubber connector (C). Secure with plastic clips (D) and (E). Plug the unused inlet with blanking plug (F) after greasing the joint. Warning: Ensure when connecting a shower to the Sanibest that the underside of the shower tray is raised by at least 15cm from the floor. 13

CONNECTION OF THE DISCHARGE PIPEWORK B 3 ø 22 ø 28 ø 32 2 Ø 32 Ø 28 Ø 20 Ø 32 Ø 28 Ø 32 I 4 5 Vertical before horizontal 6 1 1 Insert the elbow (B) into the lid until the lugs engage and turn it clockwise to the direction required. 2 Attach the rubber discharge elbow to the outlet pipe and secure with steel hose clip (I). Ensure the flap opens in the same direction as the discharge elbow. 3 Connect the other end to 22mm (3/4 ) copper or rigid UPVC pipe. 4 Horizontal pipe runs must have a minimum fall of 1:100 (10mm per metre) to the soil stack. 5 If a vertical lift is required, it must be made before the horizontal run at the start of the piperun. 6 We would recommend that a drain-off point is installed to allow the discharge pipework to be drained down before any service work. 7 If the discharge pipework runs to a level considerably lower than the unit, the 7 Air Admittance Valve 8 resultant siphoning effect can suck out the water seal in the unit. Fitting an air admittance valve capable of withstanding 10psi pressure (BBA approved) at the high point of the pipe run will overcome this problem. 8 Ensure all external pipework is adequately lagged to avoid the possibility of freezing. 9 The discharge pipework must be connected to the soil stack using an appropriate strap on boss. 9 22mm 28mm 32mm 40mm 100/110mm N.B. Any elbow on the discharge pipe of the unit will create friction loss (roughly 50cm per elbow to be deducted from the vertical pumping specification). Always use smooth bends (or 2 x 45 degree bends together) and not 90 degree elbows. Note. The discharge pipework should be copper or rigid solvent weld plastic (22mm or 32mm). VENTING EXAMPLE OF SANIBEST INSTALLATION ø 28/32/40 max 6m ø 22/28/32 3% DN 40 3% Sanibest is fitted with an active carbon filter, and requires no external venting. NORMS Sanibest conforms to EN 12050-3. Lifting plant for wastewater containing faecal matter for limited applications. SANIBEST Société Française d Assainissement EN 12050-3/02 LA05-B81 220-240 V - 50 Hz - 750 W - IP44 14

TECHNICAL DATA Application Maximum Vertical Pumping Maximum current consumption Normal Power Rating Electric Class Type Degree of protection Net Weight Voltage Frequency 1 WC + shower + bidet + washbasin 6m 3,5 A 760 W I LA05-B81 IP44 9,5 kg 220-240 V 50 Hz Usage A WC fitted with a Sanibest pump/macerator does not require any special maintenance. The Sanibest will operate automatically as soon as the required level of water enters the case. Warning: The water authorities strongly discourage the disposal of sanitary items such as condoms, tampons and sanitary pads via a WC. However, should such items be flushed down a WC attached to Sanibest, the unit is able to accept these items without blocking. Damage will occur to the Sanibest if hard objects (eg metal, wood etc) are flushed via the WC, or aggressive chemicals such as acids, caustics, solvents etc. BEST SOLUTION FOR SHOW GROUND High performance macerating pump discharging waste and water from multiple WC s and other appliances The Royal Agricultural Society of England s show ground at Stoneleigh, Warkwickshire, attracts visitors all the year round, but at Royal Show time in early July it is particularly busy when over 100,000 people from the farming industry attend the four-day event. Additional demand is placed on the facilities during this time and extra toilets are required for disabled members to ensure the influx of visitors is catered for. To meet this need plumbing and heating services engineer Michael Blake knocked together two of the existing toilets to provide a unisex toilet for disabled visitors. up: 7m along: 70m SANIBEST: A typical installation credit: The Royal Agricultural Society Michael Blake says: For various reasons, in this particular situation it was more economical and cost effective to install a Saniflo small-bore system and run the pipework just a few metres to an existing 4in waste pipe. The Sanibest unit meant we could overcome the plumbing difficulties and ensure the show ground had the facilities it required. 15

SANICONDENS BEST & PLUS Specifically designed for disposing of acidic condensate. Incorporates neutralising tray pumping height up to 4.5m maximum flow rate 342 litres / hour flow rate at 4 metres 156 litres / hour PH mini 2.5 electrical power supply 220-240 V / 50 Hz motor power rating 60 W maximum power consumption 0.38 A protection index IP20 acoustic level < 45 dba admissible waste water temperature 35 C maximum admissible waste water temperature 80 C weight 1,9 kg measurements l x d x h Sanicondens Plus: 277 x 160 x 146 mm Sanicondens Best: 279 x 160 x 254 mm volume 2.1 litres accessories supplied: non-return valve, wall fixing kit, 2 inlet adaptors, connection for an alarm, 2 metres electric cable, 6 metres drainage pipe DESCRIPTION Quiet and light, it is designed to operate with water at a mean temperature of 35 C and occasionally with water up to 80 C and a minimum ph of 2.5. Evacuation 5 4 height (m) Condensing boiler Electrical socket 3 2 1 Alarm SANICONDENS PLUS Condensate pump As per Sanicondens Best for situations where a neutralising tray is not required 0 0 2 4 6 output (l/min.) 16

THE DOMESTIC RANGE Add extra facilities from loft to basement and most places in between SANIPLUS A macerator pump that enables you to install a bathroom or en-suite with ease. SANIVITE A domestic pump for discharge of waste water from kitchen and utility rooms. SANIFLO The original macerator pump for an extra WC almost anywhere. SANITOP A macerator pump that enables you to install a WC and wash basin; ideal for cloakrooms. SANISLIM A macerator pump specifically designed for use with slimline sanitaryware. SANIPRO A macerator pump that enables you to install a WC and shower. SANICOMPACT A unique cisternless ceramic WC with a built in macerator pump. SANIPACK A macerator pump specifically designed for use with built-in bathroom units. SANISHOWER A pump for shower and wash basin. check out the website for details: www.saniflo.co.uk Saniflo Ltd. Howard House, The Runway, South Ruislip, Middx. HA4 6SE Tel: 020 8842 0033 Fax: 020 8842 1671 e-mail: sales@saniflo.co.uk 17

Go to: saniflo.co.uk/saniflo_install.aspx to view the Training Modules on the Website check out the website for details: www.saniflo.co.uk 8013 Designed by Consortium, email: info@consortcom.co.uk Saniflo Ltd. Howard House, The Runway, South Ruislip, Middx. HA4 6SE Tel: 020 8842 0033 Fax: 020 8842 1671 e-mail: sales@saniflo.co.uk Copyright 2008 Saniflo Ltd. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, computerised or otherwise without prior arrangement with and permission of Saniflo Ltd. NB: Our pumping systems are designed for the disposal of normal organic waste product, water or paper. They are not intended to replace kitchen waste or sanitary waste disposal units. As our policy is one of continuous product improvement we reserve the right to alter product specification and price without notice. All information in this publication is given in good faith. No responsibility can be accepted for any errors, omissions or incorrect assumptions. Illustrations are diagrammatic and should be regarded only as indicative of technical requirements. All vertical pumping distances are measured from base of unit. profrange/03/09