Weight Measurement Technology



Similar documents
The Do s and Don ts of Pressure Transducers

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

THE STRAIN GAGE PRESSURE TRANSDUCER

Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement

An Overview of Calibration Methods and Procedures for Process and Inventory Weigh Systems

Procon Engineering. Technical Document PELR TERMS and DEFINITIONS

Environmental Monitoring with Sensors: Hands-on Exercise

LCWM Glossary. Mettler Toledo LCWM Glossary

Type of Force 1 Axial (tension / compression) Shear. 3 Bending 4 Torsion 5 Images 6 Symbol (+ -)

Applying the Wheatstone Bridge Circuit

9. Force Measurement with a Strain gage Bridge

Statics of Structural Supports

Activity 2.3b Engineering Problem Solving Answer Key

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

MCE380: Measurements and Instrumentation Lab. Chapter 9: Force, Torque and Strain Measurements

Load Cell Accuracy in Relation to the Conditions of Use

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

Subminiature Load Cell Model 8417

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Chapter 3 Pre-Installation, Foundations and Piers

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

International Journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

Optimum proportions for the design of suspension bridge

In-situ Load Testing to Evaluate New Repair Techniques

EFFECTS ON NUMBER OF CABLES FOR MODAL ANALYSIS OF CABLE-STAYED BRIDGES

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

Stress Strain Relationships

Solid Mechanics. Stress. What you ll learn: Motivation

6 RETROFITTING POST & PIER HOUSES

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

Check out our website for this handbook and more helpful information on load cells and weigh modules

INTRODUCTION TO BEAMS

STRESS AND DEFORMATION ANALYSIS OF LINEAR ELASTIC BARS IN TENSION

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

How to measure absolute pressure using piezoresistive sensing elements

Typical Aluminum GFM Mass Flow Meter

Introduction to Solid Modeling Using SolidWorks 2012 SolidWorks Simulation Tutorial Page 1

Joist. Reinforcement. Draft 12/7/02

METU DEPARTMENT OF METALLURGICAL AND MATERIALS ENGINEERING

Ideal Cable. Linear Spring - 1. Cables, Springs and Pulleys

Overhang Bracket Loading. Deck Issues: Design Perspective

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

Reinforced Concrete Design

2.0 External and Internal Forces act on structures

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

bi directional loading). Prototype ten story

Technical Notes 3B - Brick Masonry Section Properties May 1993

ASSESSMENT AND PROPOSED STRUCTURAL REPAIR STRATEGIES FOR BRIDGE PIERS IN TAIWAN DAMAGED BY THE JI-JI EARTHQUAKE ABSTRACT

Materials. Estimating Steel. Players. Materials. Shop Drawings. Detailing Process. Standard shapes. Fabricated members, Built-up sections

Structural Failures Cost Lives and Time

Experiment 5. Strain Gage Measurements

Current Status of Seismic Retrofitting Technology

The Collapse of Building 7 by Arthur Scheuerman December 8, 06

CT-02 CABLE TRAY SYSTEMS

Introduction to Mechanical Behavior of Biological Materials

Tutorial for Assignment #2 Gantry Crane Analysis By ANSYS (Mechanical APDL) V.13.0

Structural Integrity Analysis

MATERIALS AND MECHANICS OF BENDING

Inventory Control. Inventory Control Tank & Silo Weighing

PRESS FOUNDATIONS AND MACHINE LEVELING

C ole s quality Open Frame Instrument Rotary Switch provides low

Load Cell Troubleshooting

Vibrations of a Free-Free Beam

CH. 2 LOADS ON BUILDINGS

AS COMPETITION PAPER 2008

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES AND APPLICATIONS NQF LEVEL 3 OUTCOME 1 - LOADING SYSTEMS TUTORIAL 3 LOADED COMPONENTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

Field Application Note

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Lessons 6 and 7 Foam Bridge Experiment- Forces and Stresses Lab

Stilling Well Recommendations

Safe & Sound Bridge Terminology

Mark Cramer Inspection Services, Inc.

REPAIR AND STRENGTHENING OF HISTORICAL CONCRETE BRIDGE OVER VENTA RIVER IN LATVIA

جامعة البلقاء التطبيقية

Troubleshooting accelerometer installations

STRENGTH of MATERIALS. P.A.Hilton Ltd. Two Year Warranty UNIVERSAL MATERIAL TESTER HARDNESS TESTERS DEFLECTION/FATIGUE IMPACT TESTERS POLARISCOPE

Torque Sensor Technical Information

GMC 2013: Piping Misalignment and Vibration Related Fatigue Failures

Picture 1 Lead Color Code Lead Function V-Link Function V-Link Pin Table 2 Picture 2 Node Commander software

Practical Application of Industrial Fiber Optic Sensing Systems

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

Course in. Nonlinear FEM

Tower Cross Arm Numerical Analysis

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Signal Conditioning Wheatstone Resistive Bridge Sensors

Field Damage Inspection and Static Load Test Analysis of Jiamusi Highway Prestressed Concrete Bridge in China

Steel joists and joist girders are

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

A Practical Guide to Free Energy Devices

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following.

[TECHNICAL REPORT I:]

Solar Panel Installations

Transcription:

Kistler-Morse (KM) introduced bolt-on weight measuring systems three decades ago. These devices featured Walter Kistler s invention, the Microcell. Over the years, many improvements were made to the Microcell and additional products including high stress strain sensors, load cells, and the two-axis L-Cell evolved from the original design. KM weight measurement transducers fall into two categories: Bolt-on Sensors are attached to the existing vessel supports (metal columns, beams, or silo skirts). Bolt-on transducers are ideal for retrofit applications, as they can be installed without taking the vessel out of service. However, they are not as accurate as direct support load cells due to limited control over material and method of construction of the support structure. Direct support Transducers are built into a structural element, which is installed as part of the vessel s structural support system. KM produces both tension and compression direct support load cells. Direct support transducers provide the highest accuracy, but require the vessel to be taken out of service for installation. While KM bolt-on and direct support products differ in shape, capacity, and application, most KM products share the common platform of silicon semiconductor strain gages incorporated into half of a Wheatstone bridge circuit. Definition of Terms Stress Any action on a body that results in deformation. Usually measured in pounds per square inch or Pascal s. Thermal stress Two dimensional strain caused by thermal heating (expansion) or cooling (contraction). Strain Deformation of a body or structure as a result of an applied force. Bending strain (moment strain) The relationship between the force and the amount of bending that results from it. Torsional strain Strain produced by twisting. Shearing strain The angular distortion of an object under stress. Compression Stress by forces pushing together. Tension Stress by forces causing extension (pulling). Strain gage A device that converts mechanical deflection to an electrical signal. Poisson s ratio The ratio of transverse strain to longitudinal strain the ratio for carbon steel is 0.3. Shear The component of a horizontal beam that is being measured Live load The design capacity of a vessel Working load Normal operating capacity of a vessel. Dead load The empty weight of a vessel. Before proceeding, a few definitions are needed to insure a proper understanding of the information. - 1 -

Millivolt 0.0001 volts: the unit of measure of output from sensors. PSI Pounds per square inch: Unit of measurement of stress used in the application of strain gage sensors. Wheatstone Bridge Signal Processor R c +EXC Red Transducer R a Wheatstone bridge An electrical circuit used to detect small resistance changes in strain gages. White Signal lines The lines that return the signal from the load cell to the signal conditioner. In half bridge systems, there is only one signal line. R d -EXC Black Note: Rc and Rd are fixed resistors R b Output Signal Sense lines In full bridge systems, these lines sense the excitation voltage at the load cell and return it to the power supply. The power supply then attempts to regulate the voltage to maintain a stable and accurate excitation voltage level at the load cell Theory KM Strain Gages KM uses silicon semiconductor strain gages as the strain sensing elements. The gages are solid-state resistors made from a single-crystal silicon boule, a linear elastic material. The boule resembles a cylindrical rod, and the rod is sliced and diced to form rectangular gage bars. The raw gages are acid-etched to the required resistance and aluminum wires are welded to the gages. These wires connect the gages to the circuit. The Wheatstone bridge is an electrical resistance bridge circuit used to measure differential resistance. KM s implementation of the Wheatstone bridge consists of two silicon strain gages forming one-half of the bridge circuit at the transducer, and two precision-matched resistors forming the other half of the bridge at the signal processor. This design resolves and measures small resistance changes that occur when the strain gages respond to a load. The two gages that make up the sensor half of the Wheatstone bridge are glass-fused to the transducer frame bending beam, providing a very stable and rugged bond. Imagine a piece of foam rubber with a weight on it. The weight compresses the foam in the longitudinal direction, and at the same time causes the foam to expand a small amount in the transverse direction. This same type of behavior occurs in all materials, including steel. A vessel support structure will experience these types of changes and they are in direct proportion to the material weight changes in the vessel. When a transducer is bolted to a vessel support (bolt-on) or is part of a direct support (load cell), it translates the support strain changes into bending of the - 2 -

transducer beam on which the silicon strain gages are attached. This causes the strain gages to flex in tension or compression on opposite sides of the bending beam. The gages resistances change as the sum of this flexing and create a signal change proportional to the resistance change. This signal change is used to monitor the change in material weight in the vessel. Factors that Affect Performance An independent, isolated vessel with no connection to any other vessel or adjacent structure provides the most accurate results for a weight measurement system. Examples of this type of application are floor scales and truck scales. Connections to other vessels or structures affect accuracy because the transducers interpret strain changes caused by the connecting structures as being caused by changes in the material weight. Some typical causes of error related to connecting structures and, where applicable, methods for reducing the errors follow: softening the connection with a flexible coupling or lengthening the free pipe run (increasing the length from the nearest pipe support to the connection to the vessel). The cross sectional area of the pipe, the pipe spring rate, and its unsupported length determine the influence that the piping will have. Assuming a Schedule 40 Pipe, a good rule of thumb is to have 3-5 feet of unsupported horizontal run for each inch of cross sectional area of the pipe. Elbows and couplings should be included in this measurement. Vertical piping is considered to have no spring rate. Therefore, for any weight system to be accurate, vertical piping must be offset with horizontal run flexible coupling. No Horizontal Run Flex Coupling Horizontal run length is ok for cross sectional area of pipe Catwalk between vessel and another adjacent structure - Reduce errors by allowing float between connections with a slip-joint coupling and double-nutting. Hidden load bearing members, such as discharge chutes, supported by floor - Reduce errors by breaking the hard connection with a flexible coupling. Vessel goes through roof of a surrounding structure - Reduce errors by installing a flexible seal between the vessel and the roof. Tripper conveyors or deck plating welded to structure as flooring or roofing - Eliminate errors by cutting the connection to the vessel and supporting from another structure. Rigid piping connection between vessel and another adjacent structure - Reduce errors by No Horizontal Run Horizontal run too short for cross sectional area of pipe Flex - 3 -

A well-built structure provides the most accurate results for a weight measurement system. Some typical causes of error related to the structure and where applicable, methods for reducing the errors follow: Side load causes tension on legs on this side, which could be interpreted as decreased material weight Side Load Side load causes compression on legs on this side, which could be interpreted as increased material weight Poor Foundation - A level concrete or steel foundation is essential to good system performance. If required, grout or add shims to ensure an even distribution of load on the support points. Flexible Structure - The vessel and support structure must have adequate rigidity to prevent excessive deformations, which affect strain levels read by the transducers. Uneven Loading - A vessel s weight is not evenly distributed to all legs if the structure is not level or the material center of gravity is offcenter. This can cause errors if all the legs are not instrumented. To eliminate this error, KM instruments every leg, averaging the load carried by each leg to obtain an accurate weight measurement. Side Loading - In addition to vertical loading from the structure and material weight, vessels are subject to side loads from wind, equipment vibration, etc. Side loads cause additional tension/compression forces and strains in the legs. Overall, these add up to zero; i.e., they cancel out. However, if all legs are not instrumented, the system incorrectly interprets strain caused by side loads as caused by weight change. To eliminate this error, KM recommends instrumenting every leg with weight transducers, thereby canceling the side loading effects. Tension and compression equal but opposite; cancel each other if all legs instrumented with strain gages. The following additional factors affect the weight measurement system performance: Shock loads can damage transducers - In areas where fork lifts, trucks, etc. are used, install protective barriers or stops to prevent vehicles from hitting the vessel supports. Excessive electrical noise or heat - Avoid locations with excessive electrical noise or heat when determining the application feasibility, selecting the type of weight transducer, bolt-on or direct support, and routing interconnecting cables. The signal cables between the transducers and electronics should not be run in the same conduit with high voltage control and power wiring. Strain gages measure compression, tension, thermal, bending and torsion forces at the same time. The gage cannot differentiate pure compression or tension forces. The design of the load cell or bolt on transducer takes into consideration these total forces and attempts to minimize their effect but, because bolt on devices are attached to the support structure, they will measure all of these types of forces. This must be taken into consideration when quoting accuracy - 4 -

Notes - 5 -