IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System



Similar documents
RP-6 IR-PRO RP-6. Operation & Installation Guide v1.0

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

External USB 2.0 DVD-RW Drive

DCT-16 USB HD Audio Converter

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

Notice. Reverse engineering and disassembly are prohibited.

Multi-Touch Ring Encoder Software Development Kit User s Guide

Dual DVI USB KVM Switch

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

USB PC Adapter V4 Configuration

VS-0202 VS User Manual

Composite/S-Video to VGA Video Converter

Point of view HDMI Smart TV dongle Mini RF Keyboard

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

MANUAL PC1000R

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AP IR Remote Control Installation & Operation Manual

8-Port HDMI Switch USER MANUAL VS0801H

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

Gauge Drawing Tool Slider Drawing Tool Toggle Button Drawing Tool One-Way List Drawing Tool... 8

BlueGate. Your easy to use reference for getting the most out of your product USER GUIDE. Enjoy FREE REGISTRATION

USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p

USB Port Extender Kit

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

HDMI Switch USER MANUAL VS481A

USB Shutter Control Adapter User Manual Model DSUSB-IR1

INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.

Universal Push2TV HD Adapter PTVU1000 Installation Guide

I STAR COMPUTER CO., LTD

VPL-DX15 VPL-DX11 VPL-DX10. Powerful Tabletop Projectors

Remote Control Repeater

Second Display Installation Guide Point-of-Sale Hardware System

Model: HD11-ARC. Installation Guide

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

DVB-T 730. User s Manual

2.5 HDD Enclosure Kit

Kinivo 301BN HDMI Switch

USB 2.0 Peripheral Switch USER MANUAL US221A / US421A

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

1.0. User s Guide & Manual USB 2.0 FLASH DRIVE

USB Focus Motor Controller User Manual Model FCUSB

Yamaha 01V96 Version2 Upgrade Guide

Chord Limited. Mojo Dac Headphone Amplifier OPERATING INSTRUCTIONS

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

This document is intended to make you familiar with the ServersCheck Monitoring Appliance

DC Electronic Loads 8500 series

4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER

Overview. Proven Image Quality and Easy to Use Without a Frame Grabber. Your benefits include:

Compressor Supreme Force Feedback User Manual

ATA TO IDE INTERFACE PC CARD DRIVES

Instruction Guide. 4 Port Laptop-Sized USB 2.0 Mini Hub ST4200MINI. The Professionals Source For Hard-to-Find Computer Parts

Temperature Datalogger Users Manual

ECD 2 High Performance Balanced DAC. 24 Bit /192kHz. Owner's Manual

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

2 Port KVM Switch. If anything is damaged or missing, contact your dealer.

If an occupancy of room is zero, i.e. room is empty then light source will be switched off automatically

4 Bay External Hard Drive Array RAID Tower esata USB 3.0 Enclosure. StarTech ID: SAT3540U3ER

COLOR TFT LCD MONITOR. User Manual

This document is intended to make you familiar with the ServersCheck Monitoring Appliance

Convenient Accessibility

BC Pro UPS System Standby UPS System

GEFOrcE 3D VisiON Tips & Tricks

UniOP epad33 and epad33t

TFT LCD COLOR MONITOR OPERATION MANUAL

Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

User Guide FFFA

Model #: SMART2200CRMXL

Serial ATA Hard Drive Docking Station

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

RPLIDAR. Low Cost 360 degree 2D Laser Scanner (LIDAR) System Development Kit User Manual Rev.1

USER MANUAL V5.0 ST100

Targus Wireless RF Mouse USER S GUIDE. Making Your Mobile Life Easier.

MP3/WMA Player + Digital Voice Recorder + USB Flash Drive

USER S MANUAL USB FILE TRANSFER CABLE

We reserve the right to make technical changes.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Current Monitoring Kit QUICK START GUIDE

USB 3.0 to VGA External Multi Monitor Graphics Adapter with 3-Port USB Hub VGA and USB 3.0 Mini Dock 1920x1200 / 1080p

Composite/S-Video to HDMI Video Converter with Audio

5-Port HDMI Switch MANUAL (DS-45300)

2 Port Professional USB KVM Switch Kit with Cables 4 Port Professional USB KVM Switch

DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender

If anything is damaged or missing, contact your dealer.

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

If anything is damaged or missing, contact your dealer.

Mini Amp Gizmo. User s Manual. RJM Music Technology, Inc.

Y-Not. User s Manual. RJM Music Technology, Inc.

GV- RK1352 Card Reader

Current Monitoring Kit

ST122VGAU. Instruction Manual. VGA Video Switch. 2-Port Automatic VGA Video Switch

DUKANE Intelligent Assembly Solutions

reflecta Super 8 Scanner

USB FLASH DRIVE. User s Manual 1. INTRODUCTION FEATURES SPECIFICATIONS PACKAGE CONTENTS SYSTEM REQUIREMENTS...

2 Bay USB 3.0 RAID 3.5in HDD Enclosure

Midland BT Updater BTUpdater Program Program file (x86) ), Midland

Serial ATA Hard Drive Enclosure

Transcription:

IR-PRO Operation Guide IR-PRO Professional Infrared Code Capture System

Introduction The IR-PRO is an infrared code capture system that is specifically designed for system integration professionals. Unlike the capture hardware available in universal learning remote controls, the IR-PRO incorporates a much more robust and sophisticated circuit design. This, combined with RTI s proprietary software algorithms, allows the IR-PRO to reliable capture almost any infrared code regardless of code format, frequency, output strength, battery condition, alignment position, location of infrared emitter, etc. Because RTI s remote control products are sold only through professional installers/programmers, and never directly to consumers, it is our philosophy to not incorporate programming capability directly into our products. Instead, we are committed to providing our dealers with the hardware and software tools that allow them to create re-usable programming databases in the most efficient and reliable way possible. Before using the IR-PRO, please read and follow all of the instructions in this guide. 1

Product Contents Contents of the IR-PRO dealer kit include the following items:! One (1) IR-PRO infrared code capture unit.! One (1) standard USB cable (for the IR-PRO).! One (1) mini USB cable (for other RTI products).! One (1) hard plastic carrying case.! One (1) operation manual. Software System Requirements The IR-PRO is designed to work together with RTI s Infrared Library Manager software. The minimum system requirements needed to run the Infrared Library Manager software are as follows: 2! Windows 98SE, Windows ME, Windows 2000, Windows XP or later version.! A free USB port.! At least 20 Megabytes of free disk storage.! Screen resolution of 800x600 with 256 colors.! A mouse is required.

Features and Benefits The IR-PRO incorporates many features that make it the best tool available for capturing and collecting infrared codes from almost any Audio/Video product:! Advanced infrared detection circuit ensures accurate code capture under almost any condition.! Compatible with virtually all brands of A/V equipment and remote controls.! EMI noise suppression for glitch-free acquisition.! USB port for programming. The IR-PRO acts as a standard Human Interface Device, so no special drivers need to be installed on your PC (Windows 2000 and higher).! No external power supply required. Power is derived directly from the USB port.! Feedback LEDs confirm operation.! Compact, rugged design. The IR-PRO is designed to be transported from one job site to the next without incurring damage.! Available only to professional system integrators.! Two year parts and labor warranty. 3

Operation In most cases the operation of the IR-PRO is simple and straightforward. Follow these steps to capture remote control infrared codes and store them in the Infrared Library Manager software: 1. Open the Infrared Library Manager program on your PC. If you do not have the software installed, a copy can be downloaded from RTI s website at: http://www.rticorp.com/downloads 2. Open the command library that you want to add the new remote control codes to (e.g. User.cml). 3. Select an existing remote control from the open command library, or create a new one using the Edit mode. 4. Connect the IR-PRO to your PC using the included standard USB cable. 5. Place the IR-PRO on a flat surface next to your PC. 6. Place the remote control to be captured directly in front of the IR-PRO. The front of the remote should be 3 to 6 inches from the IR capture window. 4

7. Enter the Capture mode within the Infrared Library Manager program. 8. Select the Align function. The color of the Mode LED on the IR-PRO should become orange. 9. Press any button on the remote control and verify that the Signal LED on the IR-PRO flashes red. This step also allows the frequency of the remote control s infrared carrier to be measured. Important Note: Step 9 must be repeated every time before a new remote is captured or whenever you enter the Capture mode. 10. Select the Learn function. The color of the Mode LED on the IR-PRO should become green. 11. Press and hold the button on the remote control that matches the function which is highlighted in the library s function list. Release the button when the Mode LED on the IR-PRO flashes red. 12. Repeat step 11 until all desired functions are captured into the library. 5

Front Panel Reference SIGNAL MODE SIGNAL LED IR CAPTURE WINDOW MODE LED Signal LED Red = IR Signal Present Mode LED Red = Power / Capture Complete Green = Learn Mode Orange = Align Mode 6

Specifications Power Requirements: IR Carrier Frequency Range: Operating Temperature: Operating Humidity: Dimensions: Weight: Powered directly from USB port Up to 460 khz +32 F to +122 F (+0 C to +50 C) 5% to 95% non-condensing 4.5 in. x 2.8 in. x 1.3 in. (114mm x 71mm x 33mm) 6.0 oz. (170 grams) All specifications are subject to change. 7

8

It's Under Control Remote Technologies Incorporated 18681 Lake Drive East Chanhassen, MN 55317 Tel: 952-253-3100 Fax: 952-523-3131 www.rticorp.com 2004 Remote Technologies Inc. All rights reserved. Printed in USA.