Plug and Socket Devices SolConeX 16 A Series 8570



Similar documents
Plug and Socket Devices CES 63 A Series 8579

Series 8146/5-V37 and Series 8150/5-V37

Terminal Boxes Series 8146

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Linear Luminaire with LED Series EXLUX 6402/2

Flameproof Audible Signal 115 db (A) Series YA90

A good connection. International approvals.

Control Stations Made of Polyester Resin Series 8146

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Control and Distribution Boxes made of Stainless Steel Series 8150

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

7 Lighting Technology

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Solenoid Valve Island Type 3965

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Floodlight Range Installation Guide

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

9 Control Equipment. Control Button Series 8082

Cable Plug acc. to DIN EN , Form A

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

8146/5 Series Breaker Panelboards

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

5SV Residual Current Protective Devices

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

2.12. page Products for Explosion hazardous Environment

Inductive sensor NI10-M18-Y1X-H1141

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Terminal Box. Specifications TNCN

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

400 Series Buccaneer BUCCANEER POWER. bulgin

Product and functional description

Instructions for Safe Use

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

type V46, solenoid or pneumatic operated

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Compact pressure switch Flameproof enclosure Ex d Model PCA

Technical data sheet TDS0070

Manual Motor Starter MS 116 up to 16 A Technical Data

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

HARTING Ethernet Cabling 8-poles Overview

Operating Instructions

Threaded resistance thermometer Model TR10-C, with protection tube

Bimetallic Overload Relay Specifications

Operating Instructions

Power Supplies 3. SDN-P DIN Rail Series

Type: DILM32 10(24V50HZ) Article No.:

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Type: DILM50(230V50HZ,240V60HZ) Article No.:

7000 Series Buccaneer

Inductive slot sensor

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Electric Rotary Actuator - On/Off or programmable control actuator

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

49 Series - Relay interface modules A. Features

Type: DILM9 10(24VDC) Article No.:

Safety instructions VEGADIS DIS81.CEIA/V****

Safety technique. Emergency stop module BO 5988 safemaster

Connection technology from ifm.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Software and Display instruments

Air damper actuators

R.C.C.B. s two-pole LEXIC

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Safety detection solutions

Electronic overload relay EF19 and EF45

HERZ-Thermal Actuators

Digital input modules


HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

1756 ControlLogix Chassis Specifications

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Technical Information RIA14

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Transcription:

www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle with clear position indication able to be padlocked in 0- and I-position > With motor switching capacity AC-3 acc. to IEC 60947-3 > Self-cleaning contacts for superior reliability > IP66 in any application position 12127E00 The SolConeX plug and socket devices are 16 A versions. An important safety criterion is the reliable load disconnect switch with the large, highly visible handle. Plugging in and unplugging is done easily and safely in 0 position. The plugs and sockets comply with IEC/EN 60309-1/-2/-4 (CEE), IEC/EN 60079-0, IEC/EN 60079-1 and IEC/EN 60079-7. The ability to plug the Ex-plug in non-ex-sockets is guaranteed, while operation of the Ex-socket using a non-ex-plug is reliably prevented. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 For use in x x x x For use in x x For use in x x x WebCode 8570A Installation Equipment /1

Selection Table Version No. of poles Voltage Colour Frequency h Metal Order number Weight code adapter [V] Hz kg SolConeX 16 A 10327E00 >50 green >300-500 *) 2 8570/11-302 1.120 50... 110 light grey DC 3 8570/11-303 1.120 100... 130 yellow 50 and 60 4 8570/11-304 1.120 200... 250 blue 50 and 60 6 8570/11-306 1.120 277 light grey 60 5 8570/11-305 1.120 380... 415 red 50 and 60 9 8570/11-309 1.120 480... 500 black 50 and 60 7 8570/11-307 1.120 >50 green >300-500 *) 2 8570/11-402 1.350 >50 green 100-300 *) 10 8570/11-410 1.350 100... 130 yellow 50 and 60 4 8570/11-404 1.350 200... 250 blue 50 and 60 9 8570/11-409 1.350 380... 415 red 50 and 60 6 8570/11-406 1.350 380... 380 red 50 3 8570/11-403 1.350 440... 460 red 60 11 8570/11-411 1.350 480... 500 black 50 and 60 7 8570/11-407 1.350 600... 690 black 50 and 60 5 8570/11-405 1.350 57 / 100... 75 / 130 yellow 50 and 60 4 8570/11-504 1.450 120 / 208... 144 / 250 blue 50 and 60 9 8570/11-509 1.450 200 / 346... 240 / 415 red 50 and 60 6 8570/11-506 1.450 220 / 380 red 50 3 8570/11-503 1.450 250 / 440... 265 / 460 red 60 11 8570/11-511 1.450 277 / 480... 288 / 500 black 50 and 60 7 8570/11-507 1.450 347 / 600... 400 / 690 black 50 and 60 5 8570/11-505 1.450 Variants with metal earth plate for two metal cable entries and stopping plugs 100... 130 yellow 50 and 60 4 M20 x 1.5 8570/11-304-S019 1.120 100... 130 yellow 50 and 60 4 M25 x 1.5 8570/11-304-S011 1.120 200... 250 blue 50 and 60 6 M20 x 1.5 8570/11-306-S019 1.120 200... 250 blue 50 and 60 6 M25 x 1.5 8570/11-306-S011 1.120 200... 250 blue 50 and 60 9 M20 x 1.5 8570/11-409-S020 1.350 380... 415 red 50 and 60 6 M20 x 1.5 8570/11-406-S020 1.120 380... 415 red 50 and 60 6 M25 x 1.5 8570/11-406-S012 1.120 480... 500 black 50 and 60 7 M20 x 1.5 8570/11-407-S020 1.350 600... 690 black 50 and 60 5 M20 x 1.5 8570/11-405-S020 1.350 200 / 346... 240 / 415 red 50 and 60 6 M20 x 1.5 8570/11-506-S020 1.120 Variants with auxiliary contact (NO) and cable entry with stopping plug 200... 250 blue 50 and 60 6 8570/11-306-S001 1.120 380... 415 red 50 and 60 6 8570/11-406-S001 1.350 480... 500 black 50 and 60 7 8570/11-407-S001 1.350 600... 690 black 50 and 60 5 8570/11-405-S001 1.350 200 / 346... 240 / 415 red 50 and 60 6 8570/11-506-S001 1.600 * All number of poles: All nominal operating voltages and/or frequencies not covered by other arrangements have the position of the earth contact sleeve 1 h. /2 Installation Equipment

Selection Table Version No. of poles Voltage Colour Frequency h Metal Order number Weight code adapter [V] Hz kg SolConeX 16 A plug 10329E00 09195E00 09191E00 09196E00 >50 green >300-500 *) 2 8570/12-302 0.310 50... 110 light grey DC 3 8570/12-303 0.310 100... 130 yellow 50 and 60 4 8570/12-304 0.420 380... 415 red 50 and 60 9 8570/12-309 0.310 200... 250 blue 50 and 60 6 8570/12-306 0.420 277 light grey 60 5 8570/12-305 0.310 480... 500 black 50 and 60 7 8570/12-307 0.310 >50 green 100-300 *) 10 8570/12-410 0.380 >50 green 300-500 2 8570/12-402 0.380 100... 130 yellow 50 and 60 4 8570/12-404 0.380 200... 250 blue 50 and 60 9 8570/12-409 0.380 380... 380 red 50 3 8570/12-403 0.380 380... 415 red 50 and 60 6 8570/12-406 0.380 440... 460 red 60 11 8570/12-411 0.380 480... 500 black 50 and 60 7 8570/12-407 0.380 600... 690 black 50 and 60 5 8570/12-405 0.380 220 / 380 red 50 3 8570/12-503 0.450 120 / 208... 144 / 250 blue 50 and 60 9 8570/12-509 0.430 200 / 346... 240 / 415 red 50 and 60 6 8570/12-506 0.430 57 / 100... 75 / 130 yellow 50 and 60 4 8570/12-504 0.450 250 / 440... 265 / 460 red 60 11 8570/12-511 0.430 277 / 480... 288 / 500 black 50 and 60 7 8570/12-507 0.430 347 / 600... 400 / 690 black 50 and 60 5 8570/12-505 0.430 * All number of poles: All nominal operating voltages and/or frequencies not covered by other arrangements have the position of the earth contact sleeve 1 h. Explosion Protection Global (IECEx) Gas and dust IECEx PTB 05.0023 Ex d e IIC T6 Gb (Ta = -30... +55 C) with intriniscally safe auxiliary contacts: Ex d e [ia Ga] IIC T6 Gb (Ta = -30... +55 C) Ex td A21 IP66 T80 C Db (Ta = -30... +55 C) Europe (ATEX) Gas and dust PTB 03 ATEX 1227 E II 2 G Ex d e IIC T6 Gb (Ta = -30... +55 C) with intrinsically safe auxiliary contacts: E II 2 G Ex d e [ia Ga] IIC T6 Gb (Ta = -30... +55 C) E II 2 D Ex td A21 IP66 T80 C Db (Ta = -30... +55 C) Certifications and certificates Certificates IECEx, ATEX, Brazil (INMETRO), China (China-Ex), India (PESO), Canada (CSA), Kazakhstan (TR), Korea (KCs), Russia (TR), Serbia (SRPS), Taiwan (ITRI), Ukraine (TR), USA (FM), Belarus (TR) Ship approval G, RS Installation Equipment /3

Technical Data Electrical data Version Socket 8570/11, Plug 8570/12 Rated operational voltage Main contacts max. 690 V AC / max. 110 V DC Auxiliary contacts max. 500 V AC / max. 110 V DC Rated operational current Main contacts 16 A Auxiliary contacts max. 6 A Switching capacity Main contacts: AC-3: 690 V, 16 A 4 kw 7.5 kw 11 kw DC-1: 220 V / 230 V / 240 V 380 V / 400 V / 415 V / 500 V 600 V / 690 V 110 V, 16 A Auxiliary contacts: AC-15: 500 V, max. 1250 VA AC-15: 230 V, max. 1380 VA AC-12: 500 V, max. 3000 VA DC-13: 110 V, 110 W Short-circuit protection max. 16 A gg Interlocked switch max. 4 pole switch 2 optional auxiliary contacts (ON - delayed, OFF - advanced) Ambient conditions Version Socket 8570/11, Plug 8570/12 Ambient temperature see explosion protection data -50 C on request (internal lubrication using silicone grease) Mechanical data Version Socket 8570/11 Degree of protection IP66 acc. to IEC/EN 60529 Enclosure material Polyamide, glass fibre reinforced, fire and saltwater resistant Switching handle can be locked in 0 and I positions Version Plug 8570/12 Degree of protection IP66 acc. to IEC/EN 60529 Mounting / Installation Version Socket 8570/11 Connection terminal 2 x 1.5... 6 mm 2 solid 2 x 1.5... 4 mm 2 finely-stranded Cable entries Cable gland 1 x M25 x 1.5 (positioning on the top or at the side, according to the order) Stopping plug 1 x M25 x 1.5 Version Plug 8570/12 Terminals 1 x 1.5... 4 mm 2 finely stranded Cable entries 8... 20 mm cable diameter Arrangement of Earth Contact Sockets Example: Clock hour position, Front view of socket Example: Clock hour position Marking of connections Front view of socket 09195E00 09195E00 230 V = 6 h 2 P + 3 P + 3 P + N + 02395E00 /4 Installation Equipment

Accessories and Spare Parts Designation Figure Description Art. no. Weight Auxiliary contact (retrofittable) Protective cap 10341E00 1 NO 150682 0.125 1 NC 150680 0.125 1 NO, gold contact 150686 0.125 1 NC, gold contact 150684 0.125 3 pole 150496 0.043 not for extra-low voltage version kg 4 pole 150510 0.049 05365E00 5 pole 150520 0.056 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Type A B 8570/12-3.. 43.5 76 16 A, 2 P + 8570/12-4.. 49 89 16 A, 3 P + 8570/12-5.. 16 A, 3 P + N + 56.5 92 8570/11-... SolConeX 16 A 3 pole 10338E00 10333E00 10337E00 8570/11-... SolConex 16 A 4 pole / 5 pole 8570/12-... SolConeX 16 A plug We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Installation Equipment /5