Portable Hardness Tester

Similar documents
Unmatched Metal Hardness Testing

Portable Hardness Testing Leeb Rockwell UCI

LEEB HARDNESS TESTER TH130/132/134

Using Equotip Hardness Test Blocks Abstract 1. Introduction 2. Verification of Leeb hardness testers according to standards

Mobile Hardness Testing

TR Series Surface Roughness Tester for workshop and laboratory

ULTRASONIC THICKNESS GAUGE TT100/110/120/130

Test equipment for temperature and its reduction

Hand-held thermometer Model CTH7000

How To Test A Rockwell Type Hardness Tester

MANUAL TR-110 TR-110

CYMAQ Marking System AS200 + DS7050 N-14

ACL 395 Resistivity Meter

Portable digital microprocessor thermometers with interchangeable probes

VICKERS HARDNESS TESTER. HBS HBW Kc

Electromagnetic Flow Meter

Sense it! Connect it! Bus it! Solve it! EncoderS

TENSIONMETER ** code 183_LNRSTW **

Ultrasonic Load Monitoring

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Ron 3025 Crane Scale with 1"/25mm Display

MEASURING MACHINES. Pratt & Whitney METROLOGY LABORATORY. Measurement Systems, Inc.

Highly efficient flue gas analyzer

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

Multifunction HVAC and IAQ Meter

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

TARIFF CODE and updates standard

Mini USB and USB 2.0-IP67 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Handheld portable appliance testers

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

E420 SHAFT ALIGNMENT. Entry level measurement and alignment system for rotating machines BUILT-IN WIRELESS UNITS LARGE COLOUR DISPLAY QUICK START

Series 8146/5-V37 and Series 8150/5-V37

Product Information Sheet UH28CS-12kV Hi Pot Tester

TurbiDirect TurbiCheck TurbiCheck WL

Impact testing ACTIVITY BRIEF

SJ-201P/M PORTABLE SURFACE ROUGHNESS TESTER

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

DC Electronic Loads 8500 series

Ultrasonic Reference Blocks

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Grooved gaskets. Types of gaskets

HAND TOOLS FOR PLASTIC STRAPPING

Density/Specific Gravity/ Concentration Meter DMA 500

4-Channel Thermometer / Datalogger

Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

VERZUS 750CCD Universal Hardness Tester

U-Max Chamfering endmill SPMT-WL 0.17 ( ) -WH 0.35 ( ) R Long edge cutter ( ) R AAH 0.12 (

MENG 302L Lab 1: Hardness Testing

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Multi-Function Ground

TechCut 4 Precision Low Speed Saw

Operating Instructions. Coating Thickness Gauges MINITEST 1001 MINITEST 2000

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

MInIMAT-ec. flexible data recording highly accurate

TELESCOPE Motorized Lighting Suspension

Paint Test Equipment. Holitech DC Holiday Tester Data Sheet

Instruction Manual. T3111 T3111L T3111P T3111Ex

Measurement data monitoring system

Measuring electric and magnetic fields

Multi-Range Programmable DC Power Supplies 9115 Series

Penetration. Test Methods

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Pin & Vee Block Test Machine

Toroidal Conductivity Sensor

Terminal Boxes Series 8146

Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

SERIE NEMESIS 9000 TM

MINIMAT-EC-Servo Screwdriver Spindles

SOURIAU s discrete wire sealing

SCS Directory Accreditation number: SCS 0115

Encoder WDGI 58H.

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

Digital inductive conductivity transmitter

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

How To Use A Detector 2

PreciTrack3D GmbH. PRECI 3D TRACK PRECI 3D GUN PRECI 3D SCAN PRECI 3D ROBOGUN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRODUCTS

Rotary actuators Rotary wing drives Series RAK. Brochure

Advanced Systems Tester 900AST

ACL 800 MEGOHMMETER OPERATION MANUAL

Material test chamber with mechanical convection

40.3. Control Relays and Timers

Tyco PremiAir Pneumatic Actuators

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

Microwave Meter. Instruction Manual

Ground Resistance Clamp On Tester

HR-200/300/400/500 Series

Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers

Heating oven with mechanical convection

Everything you need for protection scheme testing

Description of mechanical properties

Wahl C50 Calibrator FEATURES

Precision Lightmeters Made in Germany

Transcription:

Portable Hardness Tester Large, easy to read display with backlight Highly accurate ± 4 HL Automatic correction for impact direction Converts to all common hardness scales (,,,, HS, R m ) Light weight and easy to use Fast testing for a wide range of applications Large memory with on-screen review of data Download to PC or print directly via USB, Ethernet, or RS-232 User profiles for fast change of all settings Rugged sealed membrane keypad Internal rechargeable batteries or standard C cells Custom conversions for uncommon alloys Standardized according to ASTM A956 and DIN 50156 Equotip 3, a high quality Swiss product

Application Range Good for all metals Ideal for production level testing Best suited for on-site testing of heavy, big or already installed parts Handy for difficult to access or confined test locations Automatic compensation for impact direction Excellent for material selection and acceptance tests Easy to use and accurate on curved test surfaces (R > 10 mm) Primary Industries Metal production & processing Automotive & transportation Machinery & power plants Petro-chemical, refineries Aerospace & shipyard Metal constructions Testing services & laboratories The Equotip Measuring Principle Equotip uses a proven, dynamic testing principle. An impact body with a hard metal test tip is propelled by spring force against the surface of the test piece. Surface deformation takes place when the impact body hits the test surface, which will result in loss of kinetic energy. This energy loss is detected by a comparison of velocities v i and v r when the impact body is at a precise distance from the surface for both the impact and rebound phase of the test, respectively. Velocity measurements are achieved through a permanent magnet in the impact body that generates an induction voltage in the coil of the impact device. The signal voltage is proportional to the velocity of the impact body. Signal processing provides the hardness reading for display and storage. ~v i ~v r Impact phase HL = B * 1000 = * 1000 A v i Time Rebound phase v r Performing the Hardness Test Easy to use simple operating elements allow for accurate measurements even by occasional users. 1. Load 2. Place 3. Measure 4. Display Simply load the impact Then place and hold the Trigger the impact by pressing Showing all information device by sliding the loading impact device on the surface the trigger button. The on a large clear display. tube forward. of the test piece at the hardness value will be desired test point. instantaneously displayed. Modern electronics with power saving features provide for long operating life. The large LCD display always shows how the Equotip is configured to test. Variable function keys allow for quick change of common test parameters, and the on screen hint line shows the other active control keys. The context sensitive help files give the operator quick access to the operating instructions with the press of a single button. No subjective measuring errors are possible, giving highly repeatable results. Internal self diagnostics with error messages assure reliable test results. Readings can be stored automatically in the internal memory or sent directly to a printer. PC evaluation software allows for data analysis.

Advanced Equotip 3 Impact Devices Equotip 3 impact devices D, G, C, E, S consisting of: Equotip 3 impact device, impact body, support rings, cleaning brush, cable (4-pole) Equotip 3 impact devices DL consisting of: Equotip 3 impact device, impact body, support rings, cleaning brush, cable (4-pole), perspex sleeve Equotip 3 impact devices DC consisting of: Equotip 3 impact device, impact body, support rings, cleaning brush, cable (4-pole), loading stick Type Part number Application area Impact energy Indenter C 353 00 500 Reduced impact energy. For surface-hardened components, coatings, thin or impact-sensitive parts (small indentation). D 353 00 100 Most widely used probe. For the majority of testing applications. DC 353 00 110 Short impact device. For applications in restricted spaces, e.g. in bores, cylinders or for measurements in assembled machines. DL 353 00 120 Slim measuring nose. For measurement under extreme space limitations or on the floor of grooves. E 353 00 400 Diamond indenter. For measurements in extreme hardness ranges (above 50 / 650 ). Tool steels with high carbide content. G 353 00 300 Increased impact energy. Solid components, e.g. heavy-duty casts and forged parts. S 353 00 200 Ceramic indenter. For measurements in extreme hardness ranges (above 50 / 650 ). Tool steels with a high carbide content. 3 Nmm Tungsten carbide 11 Nmm Tungsten carbide 11 Nmm Tungsten carbide 11 Nmm Tungsten carbide 2.8 mm 11 Nmm Polycrystalline diamond 90 Nmm Tungsten carbide 5 mm 11 Nmm Ceramics

Equotip 3 Measuring Range Fields of application D/DC DL S E G C 1 Steel and cast steel Vickers Brinell Shore Rm N/mm² HRA HS σ1 σ2 σ3 81-955 81-654 38-100 20-68 30-99 275-2194 616-1480 449-847 80-950 81-646 37-100 21-68 31-97 275-2297 614-1485 449-849 101-964 101-640 22-70 61-88 28-104 340-2194 615-1480 450-846 84-1211 83-686 20-72 61-88 29-103 283-2195 616-1479 448-849 90-646 48-100 305-2194 618-1478 450-847 81-1012 81-694 20-70 30-102 275-2194 615-1479 450-846 2 Cold work tool steel Vickers C 80-900 21-67 80-905 21-67 104-924 22-68 82-1009 23-70 98-942 20-67 3 Stainless steel Vickers Brinell 85-802 85-655 46-102 20-62 119-934 105-656 70-104 21-64 88-668 87-661 49-102 20-64 4 Cast iron lamellar graphite GG Brinell Vickers 90-664 90-698 21-59 92-326 5 Cast iron, nodular graphite GGG Brinell Vickers 95-686 96-724 21-60 127-364 19-37 6 Cast aluminium alloys Brinell Vickers 19-164 22-193 24-85 20-187 21-191 20-184 22-196 23-176 22-198 19-168 24-86 21-167 23-85 7 Copper/zinc-alloys (brass) Brinell 40-173 14-95 8 CuAI/CuSn-alloys (bronze) Brinell 60-290 9 Wrought copper alloys, low alloyed Brinell 45-315 Test Piece Requirements Impact devices D, DC, DL, E, S C G Preparation of the surface Roughness class ISO Max. roughness depth R t Centre line average CLA, AA, R a N7 10 µm / 400µinch 2 µm / 80 µinch N5 2.5 µm / 100µinch 0.4 µm / 16 µinch N9 30 µm / 1200 µinch 7 µm / 275 µinch Min. weight of samples of compact shape on solid support coupled on plate 5 kg / 11lbs 2 kg / 4.5 lbs 0.05 kg / 0.2 lbs 1.5 kg / 3.3 lbs 0.5 kg / 1.1 lbs 0.02 kg / 0.045 lbs 15 kg / 33 lbs 5 kg / 11 lbs 0.5 kg / 1.1 lbs Min. thickness of sample uncoupled coupled surface layer thickness 25 mm / 0.98 inch / 0.12 inch 0.8 mm / 0.03 inch 15 mm / 0.59 inch 1 mm / 0.04 inch 0.2 mm / 0.008 inch 70 mm / 2.73 inch 10 mm / 0.4 inch Impact devices D, DC, DL, E, S C G Indentation size on test surface with 300, 30 diameter 0.54 mm / 0.021 inch depth 24 µm / 960 µinch with 600, 55 diameter depth 0.45 mm /0.017 inch 17 µm / 680 µinch with 800, 63 diameter 0.35 mm / 0.013 depth 10 µm / 400 µinch 0.38 mm /0.015 inch 12 µm / 480 µinch 0.32 mm / 0.012 inch 8 µm / 2560 µinch 0.30 mm / 0.011 inch 7 µm / 280 µinch 1.0 / 0.04 inch 53 µm / 2120 µinch 0.9 mm / 0.035 41 µm / 1640 µinch

Equotip Test Blocks Proceq is world-leading with its wide range of different Leeb metal hardness test blocks and the only producer of Leeb instruments who addresses all relevant standards (e.g. DIN 50156, ASTM 956-06) completely. Test blocks are an essential component of any hardness testing equipment. Blocks of various hardness levels are available as required by national measurement standards. The customers should choose the blocks based on the hardness level which is used for their particular application. This guarantees that the instrument s functionality can be verified on-site within the correct hardness range. Equotip test blocks are delivered calibrated with the impact device that the customer uses to check his metal parts, e.g. in HLD, HLDL, HLE. This means that the calibrations are precise and are not based on conversions. Calibration certificates are issued by Proceq (factory calibration) or an accredited institute (national traceability), as per customer request. Technical Information DIMENSIONS: 170 x 200 x 45 mm (6.7 x 7.9 x 1.8 inches) Weight: 780 g plus approx. 120 g battery pack Unit material: shock resistant ABS plastic Unit display: large, QVGA LCD with adjustable contrast and backlight Resolution: 1 HL; 1 ; 1 ; 0.1 ; 0.1 ; 0.1 HS; 1 N/mm² R m Internal data storage: ~ 100'000 measured values Battery type: rechargeable Li-Ion or 3 standard size C cells Operating temperature: 0 to +50 C (32 to 122 F) Storage temperature: -10 to +60 C (14 to 140 F) Humidity: 90 % max. Input-sockets impact devices: 20-pole Communication: Ethernet, USB & RS -232. Bi-directional with PC PC application program: Equolink 3 ACCURACY: ± 4 HL Standards and Guidelines applied ASTM A956 (2006) ASTM E140 (2013) ASME CRTD-91 (2009) DIN 50156 (2007) DGZfP Guideline MC 1 (2008) VDI / VDE Guideline 2616 Paper 1 (2002) Nordtest Technical Reports 99.12, 99.13, 99.36 GB/T 17394 (1998) JB/T 9378 (2001)

Ordering Information 353 10 100 Equotip 3 Hardness Tester, unit D, includes Equotip 3 indicating device, AC adapter, Equotip 3 impact device D with cable, test block D, USB-cable, Equotip CD, cleaning brush, coupling paste, carrying case, support ring D6 and D6a, operating instructions, quick reference guide, calibration certificate 353 10 300 Equotip 3 Hardness Tester, unit G, includes Equotip 3 indicating device, AC adapter, Equotip 3 impact device G with cable, test block G, support ring G6 and G6a, carrying case, USB-cable, Equotip CD, cleaning brush, operating instructions, quick reference guide, calibration certificate For other combinations, use Equotip 3 basic unit with impact device and test block. 353 10 050 Equotip 3 Hardness Tester, basic unit, includes Equotip 3 indicating device, AC adapter, carrying case, USB-cable, Equotip CD, operating instructions and quick reference guide. The customer needs to buy the appropriate impact device and test block in addition to the Equotip 3 basic unit 353 10 100 unit D 353 10 300 unit G 353 10 050 basic unit Accessories 353 00 091 Equotip 3 Automation Package 353 00 070 Protective carry pocket for Equotip 3 indicating device 380 00 079 Carrying strap adjustable, with padding (use together with 380 00 070) 353 00 080 Equotip 3 impact device cable 1.5 m 4-pole 353 00 086 Equotip 3 impact device extension cable 5 m 4-pole 353 00 083 Impact device cable existing Equotip 2 impact device to new Equotip 3 display device 353 00 084 Impact device cable new Equotip 3 impact device to existing Equotip 2 display device 351 90 018 USB cable, 1.8m 350 00 082 Equotip 3 RS-232 adapter cable for connection to printer 353 00 029 Rechargeable Equotip 3 battery 353 03 000 Set of support rings (12 pcs.) 350 01 015 Coupling paste Subject to change without notice. All information contained in this documentation is presented in good faith and believed to be correct. Proceq SA makes no warranties and excludes all liability as to the completeness and/or accuracy of the information. For the use and application of any product manufactured and/or sold by Proceq SA explicit reference is made to the particular applicable operating instructions. Head Office Proceq SA Ringstrasse 2 CH-8603 Schwerzenbach Switzerland Phone: +41 (0)43 355 38 00 Fax: +41 (0)43 355 38 12 info@proceq.com www.proceq.com 810 35 301E ver 06 2013 Proceq SA, Switzerland. All rights reserved.