Technical data sheet TDS0070



Similar documents
Compact pressure switch Flameproof enclosure Ex d Model PCA

Operating Instructions

Terminal Boxes Series 8146

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

2.12. page Products for Explosion hazardous Environment

Explosion proof enclosures

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Safety instructions VEGADIS DIS81.CEIA/V****

Operating Instructions

Givare NC-SRS 280 och 880

Linear Luminaire with LED Series EXLUX 6402/2

Series 8146/5-V37 and Series 8150/5-V37

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Inductive sensor NI10-M18-Y1X-H1141

A good connection. International approvals.

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Solenoid Valve Island Type 3965

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Floodlight Range Installation Guide

SEISMIC VELOCITY TRANSDUCER T1-40

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Technical Data. Dimensions

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Plastic tube flowmeters Series PT/PS

Terminal Box. Specifications TNCN

Technical Data. Dimensions

ATL Fuel Level Sender Probes

Plug and Socket Devices CES 63 A Series 8579

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Control and Distribution Boxes made of Stainless Steel Series 8150

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Pressure transmitter For general industrial applications Model A-10

Instructions for Safe Use

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters


UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Rosemount 751 Field Signal Indicator

David O Brien, CMP Products (David.OBrien@cmp-products.com)

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

LED...A Q Series Sealed High-Intensity

Single sub-base valve

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Plug and Socket Devices SolConeX 16 A Series 8570

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

How To Read A Pipe From A Sensor

Rosemount 752 FOUNDATION fieldbus Remote Indicator

SELECTION, APPLICATION & MAINTENANCE

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Operating Instructions

FGM 160 ATEX EC type examination certificate

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Threaded resistance thermometer Model TR10-C, with protection tube

Connection technology from ifm.

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Flameproof Audible Signal 115 db (A) Series YA90

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

2 & 5-Wire Overfill Sensors

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Differential-Hall-Effect based Sensors Series A5S

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Differential-Hall-Effect based Sensors Series A5S Overview

ALARMLINE ANALOGUE Linear Heat Detection System

Application Note AN1

Cable Plug acc. to DIN EN , Form A

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Product Brochure. Certified Mining Motors

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Scraper Passage Indicator. Electrical Indicator. Features

INSTALLATION AND OPERATING INSTRUCTIONS LEVEL SENSOR

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Toroidal Conductivity Sensor

CMP PRODUCTS CMP. Terminating Cables is our Business. Onshore Offshore Marine Mining Surface Underground

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Electronic Pressure Switch EDS 300

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

ATEX Zone 2 and 22 Installation Drawings and Instructions

TEIP11 I/P signal converter for standard signals. Measurement made easy

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Duct Humidity Transmitter

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Wolflite Safety Handlamp H-251E

Amphenol Cable Glands and Cord Grips Amphenol

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Transcription:

Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier infrared sensors Stainless steel housing with tamperproof protection For use with separately certified, industry standard junction boxes or OEM gas detector enclosures. Compact Size Various mounting threads available M20, ½ NPT, ¾ NPT Housing can be opened to gain access to the plug-in sensor. Gas sampling adaptor accessory available for easy calibration. Rainguard accessory with gas sampling feature also available to protect the sensor in wet environments or areas subjected to hosing. TDS 0070 Issue 1.9 29/12/12 Change Note:430 Page 1 of 6

Specification Type Housing Material Body Dimensions Weight (approx) Operating Temp Storage Temp Humidity Range Sensor Supply Voltage Electrical Output Gas Type Sensor Type Measuring Range Response Time Exd Certified Flameproof sensor housing. Stainless Steel grade 303, (Grade 316 available at additional cost) 40 mm Diameter x 60 mm Long (excluding a thread length of up to 20mm) 280 grams -20ºC to +60ºC See note 1 below. -20ºC to +60ºC See note 1 below. 0 to 95% R.H. Non-condensing 3.0 5.0 V dc, 75-85mA operating current. Either voltage output or pellistor replacement Bridge output, specify when ordering. Hydrocarbon or carbon dioxide Premier infrared Dependent upon sensor type specified when ordering T90 = <30sec. Note that the response time will be increased when the optional PTFE filter is fitted. Response time is dependent upon gas type and concentration. Certificate numbers Standards Hazardous Area Certification SIRA 10ATEX1358X IECEx SIR 10.0184X EN 60079-0 :2009 IEC 60079-0 :2007 Ed 5 EN 60079-1 :2007 IEC 60079-1 :2007 Ed 6 Ambient Temperature -20 to +60 O C (T4) (See note 1) Certificate numbers Zones 1 & 2 SIRA 10ATEX1358X IECEx SIR 10.0184X Connection details Wire function Wire colour POSITIVE sensors: Blue + ve Supply NEGATIVE sensors: Yellow POSITIVE sensors: Yellow - ve Supply NEGATIVE sensors: Blue Output White RX pin Brown, (See note 2) TX pin Orange, (See note 2) Notes: 1 The temperature ranges stated here refer to the GSH4 Exd sensor housing only. Refer to the relevant sensor data sheet for the sensor specifications. 2 When the data communications facility is not required, the ends of the brown and orange wires should be insulated and secured to prevent electrical contact with any other wires or metalwork. TDS 0070 Issue 1.9 29/12/12 Change Note:430 Page 2 of 6

Instructions for fitting a sensor inside the housing 1) Loosen the grub screw using a 2mm A/F hexagon key. Ensure that the screw is sufficiently removed to prevent it from contacting the internal threads of the sensor housing. 2) Unscrew the cover by turning it anti-clockwise. 3) Insert the sensor into the sockets on the circuit board, ensuring that it is fully pressed into position. 4) The assembly contains a black plastic spacer that fits over the sensor to reduce dead space and to provide a good seal to the inside of the cover of the housing. Gently fit the plastic spacer over the sensor, ensuring that it comes into close contact with the top of the sensor. Note that the spacer contains an internal O-ring, some resistance will therefore be felt as the spacer is fitted over the sensor. Also included is a foam washer beneath which is a PTFE filter to prevent the ingress of water or dust. Whilst offering environmental protection, this filter will increase the gas response time. If preferred, the filter can be removed, after temporarily removing the foam washer. 5) Carefully replace the cover by screwing it clockwise until the gap between the cover and flange of the housing is closed. Note that there will be some resistance as the gap closes because of the compression of the foam washer and the internal O-ring that provides a seal. 6) Re-tighten the grub screw, avoiding excessive force. TDS 0070 Issue 1.9 29/12/12 Change Note:430 Page 3 of 6

Certificate related information These instructions are specific to hazardous area installations. The following instructions apply to Gas Sensors covered by certificate numbers Sira 10ATEX1358X and IECEx SIR 10.0184X. The ATEX/IECEx certification marking are as follows: Ex d IIC T4 Gb (T amb = -20 C to 60 C) And for ATEX certified equipment only: 1180 II 2 G (reference European ATEX Directive 94/9/EC, Annex II, 1.0.6.) 1 The XXX contained within the type number GSH4 XXX is used to define the specific detector element contained within the sensor. 2 The GSH4 XXX Series Gas Sensor incorporates integral cabling, which requires suitable protection and termination, and consequently it must not be used as a stand-alone item in a hazardous area without further protection. THE FOLLOWING SPECIAL CONDITIONS FOR SAFE USE APPLY: - a) It is the user s responsibility to ensure that earth continuity is maintained via the mounting arrangement. b) The integral conductors must be suitably mechanically protected and terminated in a suitable terminal or junction facility. c) The integral conductors shall be suitably clamped within 100 mm of the point at which they exit the body of the Gas Sensor Type GSH4 XXX. d) The insulation of the integral conductors shall not be subjected to a temperature greater than 105 C. 3 The sensor is only certified for use in ambient temperatures in the range -20 C to +60 C and must not be used outside this range. 4 The maximum power rating is 1.1W, with an operating voltage range of 0 to 30V. 5 Assembling and dismantling: - The sensor is supplied fully assembled. No dismantling is required during normal service. The sensor must not be removed from its mounting when in use in a potentially explosive atmosphere. 6 Maintenance: - The user should ensure that the sensor opening is kept free from blockages such as a build up of dust or dirt that would otherwise restrict gas flow. 7 Servicing: - Power must be removed from the sensor and it must be established that there is no potentially explosive gas atmosphere present before servicing can commence. The only user serviceable part is the detector element contained within the sensor. A grub screw that must be loosened using a 2mm A/F hexagon key retains the sensor cover. When replacing the cover, the threads must be fully engaged and the grub screw must be re-tightened. 8 Emergency repairs: - The sensor is not an item to which emergency repairs can be made. 9 Adjustment: - There are no adjustment facilities on the GSH4 XXX Series Gas Sensor 10 The GSH4 XXX Gas Sensor has not been assessed as a safety-related device (EHSR 1.5). 11 The end user/installer shall be aware that the certification of the GSH4 XXX Gas Sensor relies upon the following materials used in its construction, which are suitable for most common applications: TDS 0070 Issue 1.9 29/12/12 Change Note:430 Page 4 of 6

Outer housing: stainless steel Sintered filter: stainless steel Encapsulant: epoxy resin In accordance with the note in EN 60079-0, the end user/installer shall inform the manufacturer of any adverse conditions that the GSH4 XXX Gas Sensor may encounter. This is to ensure that the GSH4 XXX Gas Sensor is not subject to conditions that may cause degradation of these materials. 12 The GSH4 XXX Gas Sensor carries the following certification marking: DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE IS PRESENT DYNAMENT LTD. GAS SENSOR TYPE GSH4 DERBYSHIRE IECEx SIR 10.0184X DE55 2DS UK Ex d IIC T4 Gb-20ºc +60ºC 1.1 WATT MAX SERIAL No. XXXX 30V MAX. II 2 G 1180 YYYY THREAD FORM ZZZZ SIRA 10ATEX1358X Notes: Additional information not ratified by SIRA may also appear on the gas sensor. YYYY denotes the year of manufacture ZZZZ denotes the thread form TDS 0070 Issue 1.9 29/12/12 Change Note:430 Page 5 of 6

Accessories GSH4 fitted with optional Rainguard Type GSH4 - GUARD featuring a gas-sampling tube for gas checks. GSH4 fitted with optional Calibration Adaptor Type GSH4 CAL-ADTR Dynament Limited Premier House The Village South Normanton Derbyshire DE55 2DS UK. Tel: 44 (0)1773 864580 Fax: 44 (0)1773 864599 email: sales@dynament.com www.dynament.com TDS 0070 Issue 1.9 29/12/12 Change Note:430 Page 6 of 6