OIL & GAS PRODUCTION AUDITING



Similar documents
Fiscal Measurement Natural Gas

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

PIPELINE FUNDAMENTALS. texaspipelines.com

TECHNIQUES FOR NATURAL GAS SAMPLING A DISCUSSION OF FIELD METHODS FOR OBTAINING SPOT SAMPLES. Randall Messman SW Regional Sales Manager

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

Flow Measurement Options for Pipeline and Open Channel Flow

Using meters to measure steam flow

Gas Line Sizing. Z Maximum gas demand shall be determined by adding all of the equipment Btu ratings from appliances connected on the system.

Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

Air Eliminators and Combination Air Eliminators Strainers

VACUUM REFRIGERATION SYSTEMS

Electronic Flow Switches

Oil and Gas Custody Transfer

OUR CONVERSATION TODAY

UPM Figure 1 MPFM installed on well pad

Compressed Gas Cylinder Program

Chokes. Types Reasons Basics of Operations Application

Daniel Venturi Tubes and Flow Nozzles Brochure

BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

(Adopted July 7, 1989)(Amended December 7, 1990) (Amended May 13, 1994) FUGITIVE EMISSIONS OF VOLATILE ORGANIC COMPOUNDS

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS

Steam System Best Practices Condensate System Piping

Arkansas Natural Gas Severance Marketing Costs

Gas Detection for Refining. HA University

FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS. Sami Halilah Dynamic Flow Computers Houston, Texas

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

REGULATORS 175/153 Series

Fundamental Principles of Rotary Displacement Meters

C. starting positive displacement pumps with the discharge valve closed.

Frequently Asked Questions Generators

Gas Custody Transfer Calibration

Custody Transfer Measurement. with the V-Cone Flowmeter

Optimize Pipeline Hydraulics with Multiphase Flow Modeling

Rusty Walker, Corporate Trainer Hill PHOENIX

Heating Water by Direct Steam Injection

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Oil and Gas Terms. Anticline: An arch of stratified rock layers that may form a trap for hydrocarbons.

Determining Lost and Unaccounted For Gas Loss. Duane A. Harris VP Sales and Support Flow-Cal, Inc Bay Area Boulevard, Suite 200 Houston, TX.

An Introduction to Natural Gas

74 Chapter CO 2 Cleaning

Thermal Dispersion Mass Flow

1805 Series Relief Valves

WORKBOOK ON OIL AND GAS ACCOUNTING - Part 2. Prepared by Professor Gary Schugart University of Houston

Chapter 200 Light Sweet Crude Oil Futures

DESIGN OF FLUID SYSTEMS STEAM UTILIZATION

Selection and Use of Water Meters for Irrigation Water Measurement 1

Model 1210C Battery Powered Pump Shown. Description

UNDERSTANDING REFRIGERANT TABLES

Optimization of Natural Gas Processing Plants Including Business Aspects

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation

Nitrogen Blanketing for Methanol Storage and Transportation

Overview of Baseboard Heating

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

CALDON LEFM 380Ci Gas Ultrasonic Flow Meter. Integrating experience, proven technology and innovation

CHAPTER IV SPECIAL REGULATIONS - GAS UTILITIES ONLY. Records. Each gas utility shall maintain and keep the following records:

Daniel Orifice Fittings Brochure. Senior Orifice Fitting, Simplex Orifice Plate Holder, Junior Orifice Fitting, Orifice Flange Union, Meter Tubes

Directive 042: Measurement, Accounting, and Reporting Plan (MARP) Requirement for Thermal Bitumen Schemes

How does solar air conditioning work?

The Pipelines Regulations, 2000

Element D Services Plumbing

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

COLORADO APCD IR Camera Survey Program Guidance/Protocol (rev. 11/8/11)

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level D

SAFETY AND HEALTH PROGRAM

What Constitutes Environmental Due Diligence?

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

Pump Formulas Imperial and SI Units

Chapter 5 - Aircraft Welding

CSA Group Safety Standards for Oil and Gas Pipeline Systems: A Life-Cycle Approach

Chromatograph Maintenance and Troubleshooting Class # 5050

Valve Solutions for Liquid Tank Storage Increase uptime and safety with high-quality valves and valve services for accurate, zero-leakage product

In-Line Electronic Flow Switches

STANDARD SPECIFICATIONS SECTION SEWER MAIN AND LATERAL CONNECTION SEALING BY CHEMICAL GROUT

The Engineering Science of Oil Pipelines

AABC Specifications for Testing and Balancing HVAC Systems

Implementing New Technology at TransCanada Meter Stations -- Better, Faster, Cheaper

DEF Q&A. A. SCR is a technology that uses a urea based diesel exhaust fluid (DEF) and a

ASimple Guide to Oil Refining

THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT page 1 THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT INTRODUCTION COEFFICIENT OF DISCHARGE

Technical Losses in Natural Gas Transportation, Distribution, and Storage. Paul Metro Pennsylvania Public Utility Commission

IBP 2778_10 HIGH EFFICIENCY ON CO2 REMOVAL IN NATURAL GAS WITH UCARSOL SOLVENTS Thiago V. Alonso 1. Abstract. 1. Introduction

Water Treatment & Purification Chemicals

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class # 2010

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

Grounding and Bonding Against Static Electricity. Jon Koppari, CSP, MS Occupational Safety and Health Instructor OSHA Training Institute

Basic Hydraulics and Pneumatics

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Natural Gas Information Contents

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Flashing and Cavitation

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

Centrifugal Fans and Pumps are sized to meet the maximum

Transcription:

OIL & GAS PRODUCTION AUDITING Wayne C. Dussel Offshore Measurement Supervisor El Paso Production GOM Basic Measurement Audit Steps I. Select location (s) to be reviewed. II. Review contracts, commingling agreements, process handling agreements, tariffs, and so on to determine audit rights, measurement equipment standards and maintenance requirements, and allocation procedures. III. Perform an onsite visit to inspect measurement equipment in use, IV. operating procedures, and maintenance procedures. Review historical maintenance records to determine if the equipment was being maintained per contract, standard, etc. V. Determine data accuracy by: comparing pipeline volumes with check meter volumes, gas and liquid quality (i.e., Btu, GPM, Shrinkage, Flash Gas, and Gravity), shakeout procedures for oil, field balancing procedures, and so on. VI. Review Allocations to determine if they were performed according to contract/agreement. Before you can review oil and gas measurement practices, you must understand both the business/quality objectives and services/responsibilities of measurement Measurement Business/Quality Objectives Provide accurate and timely measurement data for the determination of revenues, generation of cash flows, and protection of company assets without future litigation in the most cost effective manner. Ensure equipment is appropriate and properly functioning in order to provide accurate measurement. Gather and provide accurate and timely product volumes to customers/users. Gather and provide accurate and timely product component data to customers/users.

Communicate all operational and flow changes that affect accounting and the proper recording of product revenues. Comply with company, contractual, and governmental requirements. Physically protect the product while in company s custody. Provide information to Engineering for decisions and design of equipment. Verify and recommend sizes and types of measurement equipment for Engineering. Review contracts and commingling permits. Measurement Services/Responsibilities Ensure that appropriate meters are calibrated/witnessed. Ensure that meter stations and equipment are maintained. Ensure the handling, filing, and distributing of measurement associated paperwork. Assist in requests concerning measurement issues by government, pipelines, customers, accounting, and third parties. Assist Production Accounting concerning measurement issues. Provide preventive maintenance scheduling and reporting for measurement equipment. Ensure that custody transfer volumes and Btus are tracked, investigated, and resolved. Track measurement equipment breakdowns/repairs to initiate predictive maintenance. Perform data tracking and analysis on measurement equipment (e.g., meter factors, flow rates, S&Ws, and gravities). Ensure that gas and oil samples are taken for analysis and data enter appropriate databases. Handle measurement specifications and installations of new measurement devices. Assist in all upgrades, changes, and modifications of measurement equipment. Provide information and recommendations on new measurement equipment and technologies. Provide development and implementation of new or additional data tracking and analysis applications for all measurement related issues. Provide training to measurement and non-measurement personnel. Provide procurement, stocking, and shipment to field of standardized measurement equipment, spare parts, and accessories. Assist in well test issues. Provide allocation factor tracking and analysis. Ensure that proper revenues are received for volumes measured.

Although this may seem to be a long list, we can break the audit down in 3 main questions: - Is the equipment sized correctly to gather accurate data? - Is the equipment properly maintained to assure you and others of accurate readings? - Is the data used to properly allocate the product and ultimately cut the check? GAS CONTRACTS Most gas contracts are similar in content and most contains provisions related to gas measurement. Measurement Section A review of the measurement section gives you a detail of measurement specifications relating to the type of equipment, the standards under which the gas is measured, the frequency and type of test to be made, acceptable tolerances of measurement and procedures for measurement corrections and audit provisions. Equipment The contract should state the type of meter to be used for measurement, any manufacturer s recommendations, and AGA/API or other specifications. Standards Specific standards under which gas is measured are generally not detailed in the contract; however, reference is generally made to AGA/API or other publications indication computations of volume shall be made in accordance with the basic factors defined in these publications. Frequency and Type of Tests Frequency of test may be designated as monthly, quarterly, semi-annual, annual, or not at all. Monthly tests are desirable, especially if there are large volumes and the compostion of the gas stream fluctuates. The type of test may include calibration and inspection of measurement equipment and calculation of Btus, specific gravity, and gallons of natural gas per though feet (GPM). Btu A Btu is the amount of heat necessary to increase the temperature of one pound of water one degree Fahrenheit. A gas stream may contain numerous hydrocarbon compounds; however, usually field gas streams contain about 14 compounds. The Btu per cubic foot of these hydrocarbon compounds range from 1,009 for methane to 5,502 for decane; therefore, the quantity of each compound in the gas determines the Btu of the total gas stream. Since most produced gas streams are over 90% methane, actual Btu values will fall in the lower range of these two extremes.

The Btu content of gas also determines the dollar value of the gas. The Federal Energy Regulatory Commission established a policy to adjust the price of natural gas that contains a Btu other than 1,000. The zero adjustment base of 1,000 Btus was established because a Btu of 1,000 is almost equal to the Btu of pure methane; therefore, the price for gas with a Btu greater or lesser than 1,000 will be adjusted accordingly. The most common method of determining Btus is by chromatographic analysis. The chromatograph senses the electrical resistance of the different hydrocarbon compounds in the gas stream and records the result. Specific Gravity The specific gravity of a gas is the weight of a cubic foot of gas compared to the weight of a cubic foot of dry air under the same pressure and temperature conditions. The specific gravity of air is 1.0000. The hydrocarbon compounds mentioned above also have specific gravity that varies for methane to decane, from.5539 to 3.2596, respectively. Considering the gravity of each compound in the gas stream and that most gas is over 90% methane, field gravities will be in the lower range of these two extremes. The specific gravity factor is one of the primary values used in determine a gas volume. GPM The GPM is the gallons of natural gas liquids per one thousand cubic feet of gas. These tests are made when the gas is contracted for processing in a plant. The GPM may be determined by charcoal absorption and standard compression tests that physically remove the liquid for measurement or by chromatographic analysis. A comparative schedule should be made of the above data to determine that: - Actual tested dates are consistent with the contractual frequency. - Applicable measurement errors found in calibration and inspections are reflected in volume adjustments. - Equipment changes are reported to the proper departments. - Btu, specific gravity, and GPM values are reasonable. Tolerance and Measurement Corrections Historically, differences between the sales meter and the check meter or calibration of +-2% were acceptable; however, because of more accurate equipment, some contracts are now written with a +-1% tolerance. In the event the equipment is found to be inaccurate to the extent these tolerances are exceeded and check meters are not present to determine the correct volumes, the volumes may be calculated based on delivery conditions when the measurement equipment was registering accurately.

Quality of Gas This section will familiarize you with the tolerances of impurities permitted in the gas stream (e.g., water, hydrogen sulfide, carbon dioxide, and nitrogen). All impurities except water may be determine by chromatograph analysis. Water content is determined with water vapor analyzers or dew point tests. If these tolerances are exceeded the purchaser/transporter usually has the right to refuse the gas or deduct form the base price of the gas any costs incurred to upgrade the quality to acceptable standards. Gathering System Most contracts specify that the purchaser must provide, maintain, and test the measurement equipment. The producer also has the right to install check measurement equipment. Equipment Sizing Review production rates to see if the equipment sizes are adequate to record accurate data. Make an onsite visit and review the placement of the equipment to determine if they are in accordance with API/AGA and manufacturer standards. Look for liquid traps, length of straight piping upstream and downstream of metering points, GAS MEASUREMENT There are three common areas in gas measurement where errors may occur: - The meter run where the vast majority of the errors cause the seller to deliver gas free to the buyer/transporter because the gas is not being measured. - The recording instrument where errors can go both ways. - Terms of the contract. These errors are legally binding and are only changed by consent of both parties. ORIFICE METER RUN The application of the orifice meter to the measurement of flowing fluids is based on the physical principle that the pressure loss of a fluid flowing through a restriction in the line is propo9rtional to the square of the velocity of the fluid. The means of restricting the flow necessary for volumetric calculations is the orifice plate. Gas flowing through a meter run and orifice plate causes the loss of

pressure (differential) which is used in calculating the gas flow rate. In addition to the differential pressure, the static (line) pressure must be measured. Measurement Errors Anything that happens to the orifice plate ID will result in enlarging the hole, causing gas to pass unmeasured. Nicks, cuts, scratches, erosion, corrosion, bening, and so on will cause an increase in the plate ID, reducing the differential across the plant, and reducing the volume of measured gas. Examples - If something caused the ID of a 2 plate in a 4 meter run to increase by 1/8 inch, the producer would give away 14% of the gas. - A notch of.05 will results in a loss of.6% of the gas. - A plate bent toward the gas flow 1/8 will result in a loss of 2.8%. - A coating of grease 1/16 on both faces results in a 15.8% loss. - A coating of grease 1/8 results in a 17.9% loss. - A coating of grease 1/4 results in a 24.4% loss. - If the orifice plate carrier is raised about 3/8 from bottom, 8.2% of gas is lost. - A slight dulling of the edge gives away.5%. - If the orifice edge is beveled just.01, 2% is lost. - If the beveled orifice plate is put in backwards, it will result in a 20% lost. - One clean cut through the plate-sealing unit next to the tap holes gives away 6.1% of the gas. - If a 4 meter run had deposits of only.2, the loss is 1%. - If the deposits were.874 thick, the loss is 6.4%. - Liquid 1 deep in the bottom of the meter run tube results in the loss of 11.3% gas. - Grease and dirt deposits in the meter tube gives away 11.1% of the gas. OIL SALES BY LACT Lease Automatic Custody Transfer (LACT) equipment is frequently used at tank batteries or commingling facilities to sell the crude oil production where there is an oil gathering pipeline system, and the production rate is large enough to warrant this type of equipment. LACT units serve four major functions: 1. The unit transfers the custody of the crude oil production to either the purchaser or the transporter. 2. The unit measures the volume of oil transferred. 3. The unit samples the crude being transferred. 4. The unit monitors the quality of the crude being transferred and halts delivery if the crude fails to meet the required S&W specifications.

LACT Oil Measurement 1. A KNOWLEDGABLE company representative should be present at the proving of the LACT unit. 2. The KNOWLEDGABLE company representative should request the prover operator to display the calibration data for the prover. 3. The sample container contents should be thoroughly mixed to eliminate stratification of the oil. However, do not mix the sample for long periods. The pump is doing work on the sample that increased the temperature of the samples. As the temperature increase, so does the vapor pressure. Generally, a pressure of 5 psig (+-20 psia) is held on the sample container to prevent the loss of the light hydrocarbons form the oil. If these light molecules are flashed from the oil, the API gravity decreases and the S&W increases. 4. Insulate, cover, or protect the container from the sun and heat. In the direct sunlight of summer, the temperature in the container may easily reach the vapor pressure of the oil and cause flashing of the light molecules. 5. After processing the sample for API gravity and S&W, pump the sample into the sales line or to the storage tanks. Clean the samples container. Use solvents and clean clothes. Not cleaning the container will allow a buildup of heavy hydrocarbon molecules, and entrapped S&W. This will result in a lower API gravity and higher S&W for the oil in the container. Oil Provings 1. Flowing pressure during the year was within the range of the LACT. 2. Meter factors for malfunction (.25%). 3. 5 0f 6 (2 of 3) runs within.0005 of each other. 4. Witnessed by a qualified representative. 5. Proving equipment itself calibrated. 6. Shakeouts a. Solvents used is checked for contaminates. b. Sample pod is mixed for approximately 5 minutes. c. Sample container filled from the bottom up d. Sample heated to 140 degrees (+-5 degrees). e. Sample spun at the correct RPMs f. S&W content recorded at actual (no minimums). g. Sample pod cleaned periodically for fields having high paraffin and sediment build-ups. h. Thermohydromater is check periodically for accuracy.