Central Station Interface with Fire Alarm and the Relevant Codes & Standards



Similar documents
FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)

White Paper. Why Cellular as a Single Transmission Path meets the Requirements of NFPA 72. The Gradual Demise of POTS

Common Questions & Answers

Alarm Systems Using Wireless or Other Transmission Technology as a Single Path of Communication. Purpose. References. Description of Code Reference

SECURITY SYSTEM MANUAL

Internet/Intranet Alarm Communications. Maximize security and convenience with Internet/Intranet alarm communications

January 1, RE: TG-7FS Sole Path Cellular Alarm Communicator. To whom it may concern:

What Should I Expect From My Alarm Monitoring Station?

The Evolution of Requirements for Supervising Station Alarm Systems

Fire Alarm System Monitoring - CAN/ULC-S561-03

Teldat Security IP & Wireless GSM/GPRS Alarm Communicators

CONTRACT MONITORING SERVICES NEW DEALER INFORMATION AND PROCEDURES

Fire Prevention Coffee Break Training. November 2015

Austin Independent School District Police Department Policy and Procedure Manual

AlarmNet Network Overview

Creating a New Alarm.com Account

CAN/ULC-S Installation and Services for Fire Signal Receiving Centres and Systems- Ottawa 2013

CHAPTER 96: ALARM SYSTEMS

DEPARTMENT OF EMERGENCY AND MILITARY AFFAIRS East McDowell Road, #M5800 Phoenix, Arizona Telephone: Fax:

Videofied Video Verification A Guide for Central Monitoring Stations

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Voice Over IP Digital Phone Concerns with Security and Fire Alarm Communications Systems

Digital Solutions. The Future of Alarm Communications

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Module 4, Lesson 12 Fire Alarm Systems

Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by

The Jefferson County Board of Supervisors does ordain as follows:

Fire Alarm System Monitoring, a Primer for the Property Owner David Duggan, 2005

New UL 864 & NFPA th Edition Fire Alarm Control Panel (FACP) AND. Cellular Communication Regulation Advancements

GSM Voice Auto Dialer & SMS Sender JC-999

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

COMPLETE SETUP AND PROGRAMMING MANUAL FOR XT600i GPRS PANEL

From Tyco Security Products. Commercial Fire Monitoring Solutions. Dsc -- The Most Trusted Name In Fire Monitoring

ARTICLE 735. Emergency Alarm System

DSX-Soft I/O Integration Software

HERNANDO COUNTY FIRE ALARM GUIDELINES

IP Alarm System Resiliency on Disaster Recovery and ISP changes. A better alternative to DNS-based solutions

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

Crow Limited Warranty. Print Version 017

BASIC FIRE ALARM TRAINING

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Phone Company or Phony Company? Part 2 by Dean K. Wilson, P.E.

Vesta Visual Verification Alarm System - MJ Series. Keeping Home in Sight on Your Smartphone

SECURITY & MONITORING QUICK GUIDE

Security Alarm Systems

ERS-2400B. PERS-2400B Personal Emergency Reporting System

OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group

ANNEX B COMMUNICATIONS

Understanding Fire Alarm Requirements & Inspections. Presented By Bill Conroy Technical Sales For Briscoe Protective Systems Inc

Honeywell Total Connect 2.0 Remote Services. FAQs. LYNX Touch, LYNX Plus. VISTA Products. Service. Remote Monitoring and Control. Automation Services

THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS

TITLE 9-1 BURGLAR AND HOLDUP ALARM USERS REGISTRATION; FALSE ALARM

Security module CG2 User manual

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

Section TELEPHONE AUTOMATIC DIALER SYSTEM

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

Guarded community solutions Easy Series for villa and apartment projects

SafeMobile, Inc E. Algonquin Road, Rolling Meadows, IL Tel: (847) Fax: (847)

FIRE ALARM APPLICATION

VERIZON COMMENTS REGARDING STAFF S LATEST DRAFT RULES FOR MULTILINE TELEPHONE SYSTEM ( MLTS ) 911 CALLS

Chapter 67 ALARM SYSTEMS

Questions and answers (FAQ) Reliance Protectron Go! Control security system

Simon XTi Installation Guide

Loop Start or Ground Start?

FIRE ALARM SYSTEM RECORD OF COMPLETION

For business, corporate and public sector security. Protected premises, protected network

ARCO Global Tracking Systems, Inc. VEHICLE TRACKING AND THEFT RECOVERY. Worldwide Services

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

Michael Catalano 24 Nassau Avenue, Islip NY Phone (631) Chief Fire Marshal Fax (631)

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

FIRE ALARM SYSTEM RECORD OF COMPLETION

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

AlarmNet Commercial Fire. We ve Got You Covered

Before the FEDERAL COMMUNICATIONS COMMISSION Washington, DC 20554

APP USER MANUAL. Trackunit Virtual Hardware. Status / Tracking / Map

Contact ID Event Definition Codes

EXHIBIT A SCOPE OF WORK

LCD5500Z / PKP-LCD v3.x Installation Instructions

Security Systems Intrusion Alarm

VST-1815Z IP V-Alarm System VST-1852Z IP/GPRS V-Alarm System

Data Center Infrastructure & Managed Services Outline

ADT Select User Manual. 131 ADT ACN

Security Access Control System Operations Manual

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

INSPECTION AND TESTING OF FIRE ALARM SYSTEMS

IntesisBox. Making Building Automation go further. OPC Servers

Alarm User Awareness Class. National Burglar & Fire Alarm Association

ORDINANCE REGARDING ALARMS IN THE TOWN OF PLAINVILLE

White Paper: Librestream Security Overview

GUIDE GETTING STARTED IMPORTANT SUPPORT RESOURCES

Transcription:

Central Station Interface with Fire Alarm and the Relevant Codes & Standards By: Kim Caron Director of Business Development

Communication Paths History Panel Testing Requirements ULC Listed Station requirements ULC S561 Station Requirements Cellular Phone Apps

POTS: Plain old telephone line GSM: cellular IP: Internet Protocol

Panel connection from the fire alarm panel Contact ID and SIA are standard transmission protocol Mediums : POTS, IP and GSM Dual path required

History POTS have been used for monitoring with the majority monitored fire alarm systems across Canada. Dual path POTS. Was designed to have a back up should one line fail. GSM - Cellular Network Advancement of technology allows signal transmission via cellular network. Most manufactures use the Rogers Network. Coverage throughout Canada is increasing. Can be weak in areas. VERY Important to ensure a strong signal strength at time of installation to eliminate future problems.

IP Internet Protocol Needs to be used in combination with another medium. Not reliable to be used as only communication path. Internet connection not always stable and does drop from time to time, depending on the carrier. Back up power supply required to assist during power fails.

ULC accepts any of the following combinations: POTS (dual path, grandfathered) POTS / IP POTS / GSM IP / GSM GSM Supervised (polled every 90 seconds by station received and 180 seconds by Fire Panel) Above may vary depending on panel manufacture

Codes Fire Alarm, Fire Trouble, Supervisory, AC Fail, Low Battery Alarm transmission codes are programmed in the Fire Panel by the installing company. Panel sends the codes directly to the dialer which transmits to the Central Station. Exception one communicator has 4 codes preprogrammed. At time of Installation the installing company MUST test all programmed codes and provide descriptions to the central station.

Each panel manufacture does things a little different and the installing company should be trained by the manufacture prior to installing.

Process may vary slightly from station to station. Installer calls station prior to install Gives account number, along with pertain information such as panel type, medium, and time line to have account in Test. Installer needs to ensure the test all codes that will be set to the station on each path of communication. Once completed all signals need to be verified with the station and full descriptions are required for all code.

Communication to the station is very important. We are very good at the service we provide However we are not mind readers Never assume we know what each supervisory or trouble indicates. Nothing worse than telling a customer or Dealer a trouble reported without an explanation to back it up.

Ensure the Cellular communicator is showing a Strong signal strength Ensure the zone tripped is sending the correct code identifier Ensure IP supplier offers a good service. Otherwise it can cause customer and installing company frustration on high volume signal transmissions from communication and AC failures.

All ULC Fire listed Central Stations are inspected annually. At a high level ULC listed stations are required to have the following: Complete redundancy Signal Receivers Servers Operator Terminals Mantrap 2 hour rated Fire protection Outdoor/indoor cameras Voice recordings Disaster Recovery Data storage Complete Power back up UPS / Generator

Canadian Building code has adhere to ULC S561 Stations must: Fire Alarms: must complete fire dispatch within 30 seconds of station receiving the signal. Notify customer within 5 minutes of receiving a Trouble signal Fire Alarms are required to be reset within 8 hours. Fire Trouble/ Supervisor signals must be restored within 12 hours from receipt of signal. If a restore is not received from station another notification will be made. If no reset received by station another notification needs to occur. Important for dealer to train on site staff on how to reset panel.

Since 97% of the worlds population has a cellular phone Of that 97%...98% of these people never have their phone more than two feet away from them at all times. Naturally is made sense to create an app to assist the dealer.

When entering Data into the Account Search, the system will search Account Number field Address Field Account Name Field So, if you put in main for example, it would produce all your accounts in a list, that have main in the name, like Main District Office, and it would produce all accounts on Main Street as well. Then you can easily scroll and pick the one you want to work with.

Questions? Thank you. Kim Caron Director Business Development Armstrong s National Alarm Monitoring 1-866-201-0551 kim@armcom.ca www.armcom.ca