UNRIVALED EMERGENCY SOLUTIONS FOR LEDs CLASS 2 OUTPUT COMPLIANCE WITH AUTO-SENSE FORWARD VOLTAGE



Similar documents
EMERGENCY SOLUTIONS for FLUORESCENT and LED RETROFIT LAMPS

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

LED Lighting. Emergency LED Products. The Philips Bodine BSL Driver Family ELI-S-20 Emergency Lighting Micro Inverter ELI-S-100 Dimming Inverter

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

12V Dimmable Driver EL-TMDRVR

LED Sign Module. LED Super Tiny Strip. LED Accessories. LED Power Supply

High Bay Occupancy Sensor Selection Guide

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Evolve LED Area Light

LED Tubular Lamp / Kit Guide

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

Cove lighting and tight space RGB LED luminaire

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Installation and Operation Guide for PD4000 Series Power Control Center

RGB Light Panel Applications. RGB LED Light Panel FEATURES & BENEFITS SPECIFICATION SHEET

QuickSpecs. HP 480/277 Volt Solutions. Overview

Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work

Evolve LED Area Light

Installation and Operation Guide for PD4100 Series Power Control Centers

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs

16551 EMERGENCY LIGHTING SYSTEMS. C. Refer to Cornell Design & Construction Standard for Emergency Power Systems.

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Lumination LED Luminaires

Remote Control Repeater

Application Note: Emergency Battery Backup System (EBBS) Solutions for the XIM Platform

1247 Norwood Avenue, Itasca, IL (800)

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

GE Lighting. Evolve LED Wall Pack. N Series (EWNA) imagination at work

id led 4" square housing FL44

PAINT BOOTH LIGHTING

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Single Phase Soft Starter

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

CHM-27 COB Arrays White LED

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Recessed. EvoKit LED Retrofit Kits Gen 3

TC-9102 Series Surface Mount Temperature Controllers

OUTPUT CABLE CONNECTIONS:

TITAN TITAN THE HIGH BAY SERIES

MEDMASTER EXTERNAL POWER SUPPLY

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

Model #: SMART2200CRMXL

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Emergency lighting units EM powerled

Operation and Installation Manual

PEDAL POWER 2 PLUS. User s Manual

NMPK2-3LED 12V LED Puck Light Kit Source: 4.2W LEDs each Puck Light

Operating Instructions

VSO MAX HP High Flow Proportional Valve

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

T R A V E R S E 56 BEACON Products

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

EDGE Park / R Mounting R recessed

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Features. High Brightness LED Light source

Global Water Instrumentation, Inc.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

LED-INTA-0024V-41-F-O

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Highbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications

EMERGENCY EGRESS LIGHTING POWER SUPPLY PART NO COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

FLEX by 3M Light Module System

Apeiron LTE+ / E12E Power Box LED Downlight System with Automatic Battery Backup. Installation Guide

PUSH BUTTON START INSTALLATION MANUAL

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

User Guide. HDMI Active Cable Extender. DVI-7370c

PERF10 Rubidium Atomic Clock

Model: (Four Port) (Six Port) HDMI Selector Switches

WHOLESALE DIRECT INC WEST 65TH STREET

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System

For Models #6-5001, #6-7501, # & #10-12K1

IEI 232e Standalone TM Keypad Installation/ Programming Manual

id led square housing FL44

PEDAL POWER. User s Manual

PART 1 - INTRODUCTION...

C2D LowBay: All the power, none of the bulk. C2D Advantage

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

User Manual HomeGrid 3000 Solar Generator

Installation and Operation Guide PD4600 Series Converter Replacement

H45 LED - Direct and indirect pendant

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Transcription:

IOTA ILB-CP SERIES IOTA s ILB-CP Series Emergency Drivers bring dependable emergency lighting solutions for today s LED fixture designs. The IOTA ILB-CP Series operates in conjunction with the AC LED driver and array to provide code-required emergency illumination for both factory and field-install applications, delivering the added value of safety and compliance to a world of LED applications... POWERFUL SOLUTIONS FOR LED DESIGNS... The IOTA ILB-CP Series combines 10-60 volt Class 2 output with IOTA s unrivaled Constant Power design, providing constant emergency illumination with no degradation of light output for the full 90-minute runtime. The innovative characteristics of the ILB-CP Series allows for both UL Classified field and factory installation. 2

3

IOTA ILB-CP SERIES UNRIVALED EMERGENCY SOLUTIONS FOR LEDs CONSTANT POWER PERFORMANCE The Constant Power design of the IOTA ILB-CP Series delivers constant wattage to the LED array during emergency operation, maintaining illumination at a consistent level, with no degradation of emergency output for the full 90-minute runtime. This unique and innovative design eliminates concerns of insufficient foot candles along the path of egress at the end of the required 90-minute duration which can be caused by the gradual depletion of the system battery and also by loss in normal operating performance over the lifespan of the LED array. SLIM PROFILE DESIGNS The ILB-SL-CP12 Slim Profile LED Emergency Driver IOTA s ILB-SL-CP Series combines the advantages of constant power performance with the integral capabilities of a slim profile housing. The narrow design of the ILB-SL-CP Series allows for installation within LED strip fixtures and other luminaire types with limited compartment space. IOTA s innovative slim profile ILB-SL-CP12 LED emergency driver was recognized at the Lightfair Innovation Awards as well as selected for the 2014 IES Progress Report. CLASS 2 OUTPUT COMPLIANCE WITH AUTO-SENSE FORWARD VOLTAGE The IOTA ILB-CP Series features UL1310, Class 2 compliant output of 10-60 volts. The ILB-CP operates the LED array safely by automatically adjusting the forward voltage to accommodate any voltage fluctuations caused by temperature, age, or manufacturer component variances within the LED system. 10-60V OUTPUT RESPONSIBLE DESIGN IOTA ILB-CP products are designed and manufactured in compliance with adopted RoHS standards to minimize environmental impact of our electronic equipment through its complete life-cycle - from the initial production process to end-of-life recycling. The responsible design of the ILB-CP Series restricts the presence of specified chemicals and substances by utilizing quality-driven and verified components that support both our commitment to the environment and life safety product performance. 4 IOTA ENGINEERING 1-800-866-4682

THE FIRST LED EMERGENCY DRIVER UL CLASSIFIED FOR FIELD INSTALLATION The unrivaled performance capabilities of the IOTA ILB-CP Series LED Emergency Drivers allow for consistent and predictable operation with Class 2 LED systems, and has made the ILB-CP Series the first LED emergency drivers to be UL Certified for field installation projects. With 5-watt, 7-watt, 10-watt, and 12-watt constant power output, auto-sense 10-60 forward voltage, and a variety of mounting configurations, the ILB-CP Series brings reliable emergency lighting solutions to a wide range of new and retrofit applications. THE ILB-CP SPECIFIER S TOOLKIT Visit www.iotaengineering.com/cptools to access our on-line resources that can assist in selecting and specifying the ILB-CP product that meets your application requirements. Our ILB-CP Performance Calculator will easily provide the operating current and lumen output for your LED luminaire system, and our on-line sample specifications provide simple Copy and Paste specs for use with your project documentation. ILB-CP Series Compatibility and Suitability of Use While accessing the ILB-CP Toolkit, be sure to reference the Compatibility and Suitability of Use Guidelines when specifying IOTA ILB-CP LED emergency drivers for field installation. Need further assistance? You can always give our Customer Service team a call at 1-800-866-4682. FAX (520) 741-2837 www.iotaengineering.com 5

ILB-CP SERIES IOTA ILB-CP LED emergency driver models provide solutions for 5, 7, 10, and 12 watt applications. Each unit is available in six different mounting configurations to accommodate your luminaire design... ILB-CP05 5 WATT OUTPUT CONSTANT POWER OUTPUT Provides constant wattage to the LED array, preventing degradation of emergency illumination for the required runtime. 10-60V OUTPUT ADDITIONAL FEATURES UL CLASSIFIED FOR FIELD INSTALLATION UL 924 Listed, UL Classified to FTBV for field installation in accordance with project, as-installed code requirements. UNIVERSAL VOLTAGE INPUT Two wire input accepts voltages from 120 to 277 VAC, 50/60Hz. AUTO-SENSE CLASS 2 COMPLIANT OUTPUT 10-60VDC output is UL1310 Certified Output Class 2 compliant and automatically senses the LED array forward voltage requirements. Adjustments to the forward voltage are real-time to accommodate fluctuations caused by temperature, age, or component manufacturer variances. DAMP LOCATION, IC RATED, AND ENCLOSED AND GASKETED FIXTURES Suitable for Plenum, Damp Location, Recessed Type IC, and Enclosed and Gasketed Fixtures. MOUNTING CONFIGURATIONS A full selection of mounting styles are available for accommodating LED fixture designs. Refer to page 11 for detailed mounting descriptions. ROHS COMPLIANT Responsibly designed and manufactured for minimal environmental impact. Includes single-piece TBTS test switch and charge indicator accessory Long-life high temperature recyclable Ni-Cad battery Galvanized steel housing For use with switched or unswitched fixtures Meets or exceeds all IBC, NEC, and Life Safety Code emergency lighting requirements 2.7 Watts (max) 0.5A (@10VDC) - 0.08A (@60VDC) 5 Watts (-A, -R) (-B, -TM) (-J, -RJ) 3.0 lbs. 2.5 lbs. 2.75 lbs. Dimensions 9.5 x 2.4 x 1.5 (mounting center 9.0 ) ILB-CP05 5-Year Warranty 6 IOTA ENGINEERING 1-800-866-4682

7 WATT OUTPUT 10 WATT OUTPUT CONSTANT POWER EMERGENCY DRIVERS ILB-CP07 ILB-CP10 ILB-CP12 12 WATT OUTPUT 3.5 Watts (max) 0.7A (@10VDC) - 0.12A (@60VDC) 7 Watts (-A, -R) (-B, -TM) (-J, -RJ) 3.0 lbs. 2.5 lbs. 2.75 lbs. Dimensions 13.0 x 2.2 x 1.25 (mounting center 12.6 ) 3.7 Watts (max) 1.0A (@10VDC) - 0.16A (@60VDC) 10 Watts (-A, -R) (-B, -TM) (-J, -RJ) 4.0 lbs. 3.5 lbs. 3.75 lbs. Dimensions* 13.3 x 2.375 x 1.5 (mounting center 12.75 ) *ILB-CP10-B: 13.0 x 2.2 x 1.25 (mounting center 12.8 ) 5.0 Watts (max) 1.2A (@10VDC) - 0.2A (@60VDC) 12 Watts (-A, -R) (-B, -TM) (-J, -RJ) 4.0 lbs. 3.5 lbs. 3.75 lbs. Dimensions* 13.3 x 2.375 x 1.5 (mounting center 12.75 ) *ILB-CP12-B: 13.0 x 2.2 x 1.25 (mounting center 12.8 ) ILB-CP07, -CP10-B, -CP12-B ILB-CP10-A, ILB-CP12-A MOUNTING CENTER 12.6 MOUNTING CENTER 12.6 FAX (520) 741-2837 www.iotaengineering.com 7

ILB-SL-CP SLIM LINE SERIES IOTA Slim Line ILB-SL-CP Series provides constant power performance in a narrow profile housing for installation in LED luminaire designs with restrictive compartment space. ILB-SL-CP05 5 WATT OUTPUT CONSTANT POWER OUTPUT Provides constant wattage to the LED array, preventing degradation of emergency illumination for the required runtime. 8 10-60V OUTPUT ADDITIONAL FEATURES SLIM PROFILE DESIGN Narrow profile housing for integral installation within narrow and restrictive LED luminaire applications. Includes single-piece TBTS test switch and charge indicator accessory Long-life high temperature recyclable Ni-Cad battery Galvanized steel housing For use with switched or unswitched fixtures Meets or exceeds all IBC, NEC, and Life Safety Code emergency lighting requirements 5-Year Warranty UL CLASSIFIED FOR FIELD INSTALLATION UL 924 Listed, UL Classified to FTBV for field installation in accordance with project, as-installed code requirements. UNIVERSAL VOLTAGE INPUT Two wire input accepts voltages from 120 to 277 VAC, 50/60Hz. AUTO-SENSE CLASS 2 COMPLIANT OUTPUT 10-60VDC output is UL1310 Certified Output Class 2 compliant and automatically senses the LED array forward voltage requirements. Adjustments to the forward voltage are real-time to accommodate fluctuations caused by temperature, age, or component manufacturer variances. DAMP LOCATION, IC RATED, AND ENCLOSED AND GASKETED FIXTURES Suitable for Plenum, Damp Location, Recessed Type IC, and Enclosed and Gasketed Fixtures. ROHS COMPLIANT Responsibly designed and manufactured for minimal environmental impact. LENGTH 16.5 MOUNTING CENTER 16.07 2.7 Watts (max) 0.5A (@10VDC) - 0.08A (@60VDC) 5 Watts 2.4 lbs. Dimensions 16.5 x 1.54 x 1.2 (mounting center 16.07 ) ILB-SL-CP05 LENGTH 16.5 MOUNTING CENTER 16.07 IOTA ENGINEERING 1-800-866-4682 WIDTH 1.54 HEIGHT 1.2 WIDTH 1.54 HEIG

SLIM PROFILE CONSTANT POWER EMERGENCY DRIVERS ILB-SL-CP07 ILB-SL-CP10 ILB-SL-CP12 7 WATT OUTPUT 10 WATT OUTPUT 12 WATT OUTPUT 3.5 Watts (max) 0.7A (@10VDC) - 0.12A (@60VDC) 7 Watts 3.0 lbs. Dimensions 22.44 x 1.2 x 1.2 (mounting center 22.0 ) 3.7 Watts (max) 1.0A (@10VDC) - 0.16A (@60VDC) 10 Watts 3.5 lbs. Dimensions 24.17 x 1.2 x 1.2 (mounting center 23.78 ) 5.0 Watts (max) 1.2A (@10VDC) - 0.2A (@60VDC) 12 Watts 3.5 lbs. Dimensions 24.17 x 1.2 x 1.2 (mounting center 23.78 ) ILB-SL-CP07, -CP10, -CP12 LENGTH: ILB-SL-CP07 22.44 LENGTH: ILB-SL-CP10, ILB-SL-CP07 -CP12 24.17 22.44 ILB-SL-CP10, -CP12 24.17 HEIGHT 1.2 HEIGHT 1.2 MOUNTING CENTER: MOUNTING CENTER: ILB-SL-CP07 22.0 ILB-SL-CP07 ILB-SL-CP10, 22.0 -CP12 23.78 ILB-SL-CP10, -CP12 23.78 WIDTH WIDTH 1.2 1.2 FAX (520) 741-2837 www.iotaengineering.com 9

SPECIALTY LED EMERGENCY BATTERY PACKS IOTA offers specialized constant current LED emergency battery packs with increased wattage output, external battery configurations, and coldweather capability... -20 Cold-Weather battery packs are designed specifically for use in cold-weather applications such as outdoor egress or other freezing environments. HEATING BLANKET The specialized heating blanket protects the battery from extreme temperatures that can render the battery inoperable. When the temperature drops, the heating blanket is activated and maintains the battery temperature within acceptable parameters. TEMPERATURE CONTROL CIRCUITRY The temperature control circuitry activates the heating blanket at low temperatures and also prevents the charging circuit from attempting to charge the battery until the battery temperature has reached acceptable levels. COMPONENT RECOGNIZED UL Component Recognized for factory installation in the U.S. and Canada. DAMP LOCATION LISTED Suitable for use in damp location applications. ILB-3020 BATTERY OPTIONS Two ILB-3020 battery configurations available to accommodate varying fixture requirements. ROHS COMPLIANT Responsibly designed and manufactured for minimal environmental impact. COLD WEATHER OPTION (-CW) ILB-3020 and -CW 24 WATT OUTPUT (Dual) 120/277 VAC, 60Hz ILB-3020: 5.5 Watts ILB-3020-CW 5.5 Watts (86 Watts w/ heating element on) Output Voltage 27-30 VDC 750 ma (constant) Output Power Up to 24W max ILB-3020: 0 to 50 C ILB-3020-CW: -20 to 50 C 4.0 lbs. UL Conditions of Acceptability Must be factory wired. temperature must not exceed 50 C. Housing Dimensions 9.5 x 1.0 x 2.0 (mounting center 9.0 ) ILB-3020 BATTERY 8- (x2) ILB-1826 and -CW 20 WATT OUTPUT (Dual) 120/277 VAC, 60Hz ILB-1826: 5.5 Watts ILB-1826-CW 5.5 Watts (86 Watts w/ heating element on) Output Voltage 18-26 VDC 750 ma (constant) Output Power Up to 20W max ILB-1826: 0 to 50 C ILB-1826-CW: -20 to 50 C 4.0 lbs. UL Conditions of Acceptability Must be factory CAN wired. DIMENSIONS temperature must not exceed 50 C. Housing Dimensions LENGTH 9.5" 9.5 x 1.0 x 2.0 (mounting center 9.0 ) MOUNTING CENTER 9.0" ILB-1826 BATTERY 7- (x2) BATTERY CONFIGURATION WIDTH 2.0" HEIGHT 1.0" COMPONENT HOUSING 1.7".5" 16- (x1) 2.5" 6.0" 2.375" 10 For cold-weather battery packs, add approximately 1/8 to the battery width and height to accommodate the heating blanket. IOTA ENGINEERING 1-800-866-4682

IOTA ILB-CP Emergency Drivers are available in a variety of wattage and mounting configurations to accommodate various performance requirements and fixture types. When specifying the ILB-CP unit for your project, add the desired wattage and mounting suffix to the ILB-CP model number. (Mounting configurations not required for Slim Profile ILB-SL-CP units). ILB-CP - ILB-CP ORDERING GUIDE 05 07 10 5W Power 7W Power 10W Power A B Dual Flex Provides dual flex for wiring to both the fixture or driver compartment and test accessories. Integral Non-Flex Allows for integral installation within the driver compartment. May also be mounted atop the fixture when used with a TMK cover accessory. B Configuration A Configuration ILB-SL-CP 12 05 12W Power 5W Power J R Single Flex Junction Box Mount Mounts to the junction box and provides flexible conduit for remote mounting of the test accessories. Dual Flex w/ Reflector-Mount TBTS Provides dual flex for wiring to the fixture. The TBTS test accessory hardware installs directly within the reflector. (Recommended for OEM installation only.) FLEXIBLE CONDUIT TO TEST ACCESSORIES (36 ) R Configuration J Configuration WIRING TO FIXTURE 07 10 7W Power 10W Power R-J Single Flex w/ Reflector-Mount TBTS Mounts to the junction box. The TBTS test accessory hardware installs directly within the reflector. (Recommended for OEM installation only.) R-J Configuration 12 12W Power TM Top-Mount Non-Flex Top-mounting option for running wires directly into the driver compartment. Test accessories are then installed within the fixture. TM Configuration WIRING ILB-CP DIAGRAM ( A CONFIGURATION) UNIT CONNECTOR TBTS WHITE/BLACK WHITE/BLACK FLEX B RED OR RED/BLK(+) WHT/RED ILB-CP SERIES FLEX A RED/WHITE (+) BLUE/WHITE (-) BLACK/ORG (120-277V) WHITE RED (+) BLUE (-) WHITE/BLACK WHITE/BLACK LED ARRAY UNSWITCHED COMMON 1 THE PROPER VOLTAGE LEAD IS SELECTED AND THE UNUSED LEAD IS CAPPED. ILB-3020 AND ILB-1826 DIAGRAM COMMON SELECT PROPER LOAD REQUIREMENT. SINGLE WIRE FROM STD DRV ONLY (BLUE) 20W LED BLACK AC DRIVER SWITCHED OR UNSWITCHED LINE COMMON BATTERY PACKS #2 3 RED (+) BLACK (-) RED (+) RED WHITE (-) RED RED ILB-3020 BLUE ILB-1826 RED/WHT 20W LED 20W LED 20W LED 20W LED* 1 BLACK (120V) ORANGE (277V) UNIT CONNECTOR AC DRIVER #1 WHT/RED RED OR RED BLK (+) 1 CHARGE INDICATOR OR TBTS WHITE DRIVER (-) DRIVER (+) WHITE BLK/ORG 277V (ORG) 120V (BLK) SWITCHED OR UNSWITCHED LINE 3 2 TEST SWITCH 1 COMMON The ILB-CP Series is provided with a single-piece TBTS test accessory which serves as both a test switch and a lit indication that the battery is being charged. The ILB-3020 and ILB-1826 feature connectors for wiring to the driver and battery packs and hardwiring to the input connections. Numbers on the diagram indicate the following: 1. Test Accessories - For TBTS units, the TBTS also functions as the test switch, therefore no test switch is present on the common. 2. Dual Voltage Input - The ILB connects to either a 120V or 277V input lead. The unused lead is capped. 3. Cold Weather Pack - The additional wiring is utilized for operation of the battery heating element on the ILB-3020-CW. 4. Pack Options - The ILB-3020 battery is available as either (1) 16-cell or (2) 8-cell battery packs. FAX (520) 741-2837 *EMERGENCY OPERATION www.iotaengineering.com 11

IOTA Engineering is dedicated to providing products that meet the standards our customers demand as well as the superior service they deserve. All IOTA products receive 100% quality inspection before shipment to ensure proper and satisfactory operation. IOTA warranties all emergency drivers in the continental United States and Canada from defects in materials or workmanship under normal use for five years from date of retail purchase and will repair or replace any IOTA product found to be defective in materials or workmanship free of charge. For additional information on IOTA s LED emergency drivers and other emergency lighting solutions, visit us at www.iotaengineering.com. Our website features the latest up-to-date information for comparing models, specifying products, or assisting with installation. Our on-line Technical Library puts you one click away from dozens of IOTA Specification Sheets and Installation Manuals, in addition to helpful specification tools such as the ILB-CP Performance Calculator. Also, check out our IOTA Media Room to stay current on the latest news in product offerings and design enhancements for your emergency lighting options. Need some additional assistance? You can easily contact your Customer Service Team via e-mail by visiting our IOTA Contacts page. Bookmark IOTA at www.iotaengineering.com! DISTRIBUTED BY: P.O. BOX 11846 TUCSON, AZ 85734 1361 E. WIEDING ROAD TUCSON, AZ 85706 1-800-866-4682 FAX (520) 741-2837 www.iotaengineering.com REV 072815 IOTA Engineering, L.L.C. 2015. All Rights Reserved.