Control and Distribution Boxes made of Stainless Steel Series 8150



Similar documents
Control Stations Made of Polyester Resin Series 8146

Terminal Boxes Series 8146

Series 8146/5-V37 and Series 8150/5-V37

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Linear Luminaire with LED Series EXLUX 6402/2

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Plug and Socket Devices CES 63 A Series 8579

Plug and Socket Devices SolConeX 16 A Series 8570

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

Flameproof Audible Signal 115 db (A) Series YA90

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Terminal Box. Specifications TNCN

Compact pressure switch Flameproof enclosure Ex d Model PCA

Operating Instructions

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Inductive sensor NI10-M18-Y1X-H1141

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

IECEx Certificate of Conformity

Explosion proof enclosures

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

9 Control Equipment. Control Button Series 8082

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

SEISMIC VELOCITY TRANSDUCER T1-40

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Technical Data. Dimensions

Solenoid Valve Island Type 3965

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Floodlight Range Installation Guide

2.12. page Products for Explosion hazardous Environment

Control- and feedback head for integrated mounting on Robolux valves Type 2036

7 Lighting Technology

Aluminium Standard. Technical Data. Included in delivery

STB Series Enclosures

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical data sheet TDS0070

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Operating Instructions

4/2-Way Pneumatic Solenoid Valve

A good connection. International approvals.

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Operating Instructions

ETC130 / 140 Inground Uplights - Gimbal LED. Presentation Overview

8146/5 Series Breaker Panelboards

Electric Rotary Actuator - On/Off or programmable control actuator

Plastic tube flowmeters Series PT/PS

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

din din-s 90Ah/plate 155Ah/plate 115Ah/plate 140Ah/plate

Series 3730 Type Electropneumatic Positioner

Guide to enclosures for potentially explosive atmospheres

CUSTOMS UNION. CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В Series RU No

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Inductive slot sensor

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

System 8. ü ( System 8

Worcester DS/DM Series UltraSwitch Switch box

Technical Data. Dimensions

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Threaded resistance thermometer Model TR10-C, with protection tube

Feed-through terminal block - SSK 110 KER-EX

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

ASSEMBLED SOCKET-COMBINATIONS

Analog signal converters CC-E I/I Current / current isolators

Electro-pneumatic control valves

Cross-beam scanning system to detect slim objects. 100 mm in

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Instructions for Safe Use

3/2-way pneumatic cartridge solenoid valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

TTF300 Field-mount temperature transmitter

3500/93 System Display

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building.

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Technical Specifications

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

Type testing

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Transcription:

www.stahl.de > Circumferential protection channel prevents water entry > Extended temperature range due to high-quality seal s > Optionally with hinges / cam locks or screw-on cover > Hinge versions with large opening angle 130 > Flange plates tightened from the outside enables simple installation > Standard sizes on stock > Special sizes on request 14111E00 Control devices and control units are assembled clearly in control stations. The enclosure is available in brush finished stainless steel 1.4404 and 1.4301. The roduct range includes a wide range of enclosure sizes with different heights. Since there are so many possible combinations of components, every control station is designed and manufactured to order. The number of devices installed depends on the size of the control station as well as on the space required for the built-in devices. ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x WebCode 8150B Control evices /1

Equipment Table for Control Boxes 8150, for built-in components with mounting grid 42 mm 09338E00 09339E00 09340E00 8082 Control devices with actuators d 38 mm 8010 Indicating lamp 8082/8010 Illuminated pushbuttons with mounting grid 42 mm such as: control devices 8082, indicating lamps 8010 and illuminated pushbuttons 8082/8010 size 4 Fig. 4.1 1.4301 176 116 91 1.4404 0116-091-2311 0116-091-3311 size 5 08922E00 A Fig. 5.1 Fig. 5.2 Fig. 5.3 Fig. 5.4 1.4301 176 176 91 1.4404 08292E00 08930E00 08931E00 08932E00 A A size 6 Fig. 6.1 Fig. 6.2 Fig. 6.3 Fig. 6.4 1.4301 236 176 91 1.4404 08935E00 08936E00 08937E00 08938E00 A A Fig. 7.1 Fig. 7.2 1.4301 08941E00 08942E00 Fig. 7.3 Fig. 7.4 1.4301 08943E00 A A 08944E00 /2 Control evices

size 8 with mounting grid 42 mm such as: control devices 8082, indicating lamps 8010 and illuminated pushbuttons 8082/8010 Fig. 8.1 Fig. 8.2 1.4301 360 360 91 1.4404 08948E00 08949E00 Fig. 9.1 1.4301 08954E00 Fig. 9.2 Fig. 9.3 1.4301 08952E00 A A 08953E00 Control evices /3

Equipment Table for Control Boxes 8150, for built-in components with mounting grid > 42 mm 09336E00 09337E00 09342E00 09341E00 01842E00 8082 Control devices with actuators d > 38 mm 8008 Control switches 8405 Ammeter with mounting grid > 42 mm such as: control switches 8008, ammeters 8405, control devices 8082 with actuators d > 38 mm size 4 Fig. 4.4 Fig. 4.5 Fig. 4.6 Fig. 4.7 1.4301 176 116 91 1.4404 0116-091-2311 0116-091-3311 08925E00 08926E00 08927E00 08928E00 A A size 5 Fig. 5.5 Fig. 5.6 1.4301 176 176 91 1.4404 08957E00 size 6 08958E00 Fig. 6.5 Fig. 6.6 1.4301 236 176 91 1.4404 08959E00 A A 08940E00 Fig. 7.5 1.4301 08945E00 Fig. 7.6 Fig. 7.7 1.4301 08946E00 A A 08947E00 /4 Control evices

size 8 with mounting grid > 42 mm such as: control switches 8008, ammeters 8405, control devices 8082 with actuators d > 38 mm Fig. 8.3 Fig. 8.4 1.4301 360 360 91 1.4404 08950E00 08951E00 Fig. 9.4 1.4301 08955E00 Fig. 9.5 1.4301 08956E00 Explosion Protection Global (IECEx) Gas and dust IECEx PTB 09.0049 Ex d e ia/ib [ia/ib] ma mb q IIA, IIB, IIC T6, T5, T4 Gb Ex tb IIIC IP66 T130 C, T95 C, T80 C b Europe (ATEX) Gas and dust PTB 09 ATEX 1109 E II 2 G Ex d e ia/ib [ia/ib] ma mb q IIA, IIB, IIC T6, T5, T4 Gb E II 2 Ex tb IIIC IP66 T130 C, T95 C, T80 C b Certifications and certificates Certificates IECEx, ATEX Technical ata Electrical data Rated operational voltage max. 1100 V AC / C depending on explosion protected components used Rated operational current max. 630 A depending on explosion protected components used Rated cross section 300 mm 2 depending on explosion protected components used Ambient conditions Ambient temperature - 60... + 85 C... depending on explosion protected components used Control evices /5

Technical ata Mechanical data egree of protection Material Sealing gasket Flanges Standard Option Cover fixing Standard Option Connection Terminals Tightening torque IP65 acc. to IEC/EN 60529 (others on request) 8150/5-...-...-...-2...: stainless steel 1.4301, brush finished 8150/5-...-...-...-3...: stainless steel 1.4404, brush finished Silicone, foamed In the standard version, the enclosures are supplied without flanges. epending on order requirements the enclosures can be installed on one or more sides with flanges; flange : stainless steel with captive M6 stainless steel combo head screws with cover hinges epending on order requirements at the built-in components or at the terminal blocks. The rated operational voltage, the rated operational current and the rated cross-section depend on the terminal type used and the explosion protected components. Permissible rated cross-section which can be used - max. 300 mm 2. The maximum number of terminals for the respective enclosure size is indicated in the EC Type Examination Certificate. according to specifications of the terminal block manufacturer imensional rawings (All in mm) - Subject to Alterations G H 9,5 7 25 Ø 7 C A B a2 F b2 c2 a1 E b1 c1 12648E00 Width Heigth epth Overall depth Fastening dimensions Type E F G H a1 a2 b1 b2 c1 c2 8150/1-0176-0116-091 176,5 116,5 91 106 136 76 212 152 228 168 8150/1-0176-0176-091 176,5 176,5 91 106 136 136 212 212 228 228 8150/1-0236-0176-091 236,5 176,5 91 106 196 136 272 212 288 228 8150/1-0360-0176-091 360 176,5 91 106 320 136 396 212 412 228 8150/1-0360-0360-091 360 360 91 106 320 320 396 396 412 412 8150/1-0727-0360-091 727 360 91 106 687 320 763 396 779 412 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /6 Control evices