MEDICAL SYSTEMS. Monnal T60. Touch and Breathe. www.airliquidemedicalsystems.com



Similar documents
The intelligent solution for the mobile ICU

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

DATA SHEET. Capnography option. November 2013 V2.2

Oxylog 3000 plus Emergency & Transport Ventilation

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home.

Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care

The Anesthesia Ventilator

Home Healthcare Respiratory Catalogue

Your personal anesthesia assistant DRÄGER PRIMUS

D A cost effective monitor that meets your clinical needs VISTA 120

Critical Care Therapy and Respiratory Care Section

BIPAP Synchrony TM AVAPS

Impact Uni-Vent 754 Portable Ventilator

Boaray 700 Anesthesia Machine

Puritan Bennett 980 Ventilator Patient Setup Quick Reference Guide

Movita Ceiling Supply Unit Medical Supply Units

Agila Ceiling Supply Unit Medical Supply Units

AutoFlow The Oxylog 3000 plus incorporates the benefits of pressure controlled ventilation into volume controlled ventilation

Dräger Globe-Trotter GT5400 Neonatal Transport

INTRODUCING RESMED S. Home NIV Solutions. S9 VPAP ST-A with ivaps S9 VPAP ST. Why choose average when you can choose intelligent?

MT Monitoring and IT Solutions for supporting patient safety and care INFINITY IN-HOSPITAL TRANSPORT SOLUTIONS

«The compact and mobile testing device for ventilators.»

Carina Pocket Guide Software version 3.n. The Carina Pocket Guide is not a replacement or substitute for the Instructions for Use.

Dräger PSS 3000 Self Contained Breathing Apparatus

The bridge to more efficient care PONTA SUPPLY BEAMS

2000 Respironics, Inc. All rights reserved.

Effective Treatment for Obstructive Sleep Apnoea

GE Healthcare. Avance Carestation. Innovating with you, shaping exceptional care

The Puritan Bennett 980 Ventilator

Puritan Bennett 840 Ventilator User s Pocket Guide. Puritan Bennett 840 Ventilator Pocket Guide

Table of contents. Exercise 1 Passive exhalation port 13. Exercise 2 Active exhalation valve 15

Common Ventilator Management Issues

Dräger PARAT Escape Hoods

How To Use An Irius Pid Detector

Sleep Therapy I Ventilation I Patient Interface. Sleep Therapy. Sleep therapy solutions for every patient

The centrepiece of a complete anaesthesia workstation

Oxygenation and Oxygen Therapy Michael Billow, D.O.

Dräger Babylog VN500 Neonatal Open Care

From AARC Protocol Committee; Subcommittee Adult Critical Care Version 1.0a (Sept., 2003), Subcommittee Chair, Susan P. Pilbeam

life energy System solutions for air rescue and air medical services The next generation

MECHINICAL VENTILATION S. Kache, MD

Ventilators/Transport*

Artificial Ventilation Theory into practice

A ANESTHESIA SYSTEMS. intuitive effortless precise

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

Home Ventilator Breath of Life Home Medical Equipment and Respiratory Services

Airway Pressure Release Ventilation

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

Moving beyond telemetry INFINITY M300

Offering more. Series

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

Auto Flow 20 Questions 20 Answers. Joseph Fitzgerald

Dräger Evita Infinity V500 ventilator ICU Ventilation and Respiratory Monitoring

Operator s Instruction Manual

Vista 120 Central Monitoring System

Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up

FLOW-i ANESTHESIA DELIVERY SYSTEM

D Non-Invasive Ventilation (NIV) with the Oxylog 2000 plus and Oxylog 3000 plus

Product Information Sheet UH36 Hi Pot Tester

How can I protect valuable assets from fire and ensure business continuity?

Monitoring and It solutions for supporting patient safety and care. InfInIty

Our Vector range is growing, so can your profit. Vector Vector 1850

Thyristor-controlled power supplies and battery chargers

Phoroptor VRx Digital Refraction System

Stellar 150 Invasive and noninvasive ventilator

BX Series Tonne Cushion Models Tonne Pneumatic Models

LEICA DNA digital levels Advantages that move you ahead. LEICA DNA digital levels

VELA. ventilator user guide. Critical care ventilation

The Anesthesia Ventilator

Nurses and Respiratory Therapists Working Together for Safe Alarm Systems Management

ELECTRIC FORKLIFT TRUCKS

Aliseo Anesthesia system

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display!

Nasal-Aire II Critical Care Single-use CPAP interface by InnoMed The comfortable, economical solution to non-invasive ventilation!

Battery Powered Digital Mass Flow Meters for Gases

Concept. Monitoring Unit. Patient Box. Defibrillator/Pacer Unit.

EyeMag Medical Loupes from ZEISS Seeing is believing NEW! LED illumination

Philips Respironics CEU Programs

Ventilator Application of the Passy-Muir Valve David A. Muir Course Outline Benefits Review of the Biased Closed Position No Leak Passy-Muir Valves

Cable-free by ATMOS LED technology ATMOS HL 21 LED. Totally free! The cable-free headlight. MedizinTechnik

Vivo 50/60 PC Software Help (english), version Introduction. 3. Dialogs. 7. Year data view. 8. Alarm view. 2. User interface. 9.

UNITOR VACUUM cleaners

RiMatrix S Make easy.

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Hospital Respiratory Care Catalogue

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

DRAFT V5 09/14/ Air ambulance services.

Management of electric vehicle fleet charging

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Datex Ohmeda. Centiva /5. Service Manual Software rev. 2.1n

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Leica DNA digital levels Advantages that move you ahead

Tel.X Ni-Cd battery. The compact solution for stationary applications

lifting stations motralec

Nederland België / Belgique

Impact Uni-Vent 750 Portable Ventilator

MINIMAT-EC-Servo Screwdriver Spindles

Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks

Transcription:

MEDICAL SYSTEMS Monnal T60 Touch and Breathe www.airliquidemedicalsystems.com

Close to the emergency Monnal T60 has been designed for mobile medical intervention in all intensive care environments, both inside and outside of a hospital setting. It puts into the hands of transport medical teams the highest standards of ventilation for critical patients, adults and children. Monnal T60 is the companion for medical care teams to increase their effectiveness even more: in land and air mobile units, helicopter, plane, long distance ambulance transport during intra-hospital transport in emergency and trauma rooms in post-operative recovery rooms and intensive care units. Monnal T60 easily adapts to all environments requiring mobile intensive care. Monnal T60 meets the demands of situations that are always unique and in difficult or extreme conditions. light and compact: 3,7 kg autonomous in air and electricity: 5 hours extendable with interchangeable batteries for continuity of operations and increased transportation options robust and resistant over time: protection of connections and integration of expiratory assembly integrated accessories: holder and protection systems for optimum configuration and movement of the patient: - wall-mounted charging station - carrying case - intra-hospital universal support - rolle stand Air transport air transport certification (standard EN 13718 and RTCA DO-160F) 20G resistance automatic compensation for atmospheric pressure changes adjustable screen brightness highly visible alarms mobility Ergonomic grip and carry handle

Close to medical teams Close to the patient Monnal T60 is the solution for fast and reliable access to care. It provides effective respiratory support in the shortest possible time. Very intuitive to use, the Monnal T60 allows medical teams to quickly familiarize themselves with the ventilator and focus on vital treatment of the patient. Accurate, complete and accessible monitoring in the first moments of patient care is crucial for planning, monitoring, and adapting care. With its comprehensive monitoring capabilities, Monnal T60 ensures safe ventilation throughout patient transport. grouped and localized connectivity for simple preparation of the ventilator case designed for the pre-connection of cables and patient circuit automatic emergency modes by simple adjustment of weight (IBW*) for a quick and safe start of the ventilation l a r g e c o l o r s c r e e n f a c i l i t a t i n g t h e readability of information in all conditions: adjustable brightness, high contrast display, 180-degree swivel screen unique monitoring zone to follow all patient information monitoring screen function with extended time curves large alarm lights that are easily identifiable in all environments and can be disabled if necessary Intuitive use speed vision Ventilation safety large touch screen unique way of intuitive use: select, adjust, confirm contextual menu monitoring of exhaled CO 2 (optional) to be assured of correct patient intubation and continuously monitor ventilation efficiency (mainstream technology) automatic monitoring of the Plateau Pressure for lung protection of the patient Grouped and localized connectivity Visible alarm lights * Ideal Body Weight: weight predicted by patient s height

Close to breathing Light and compact Large color touch screen Alarm zones that are highly visible and can be disabled Monnal T60 provides high quality care for the successful treatment of patients. Medical teams can effectively adapt the treatment to meet the needs of their patients: high performance of invasive and non-invasive ventilation, automatic transport ventilation; volume and pressure modes, CPAP and pressure support modes. Monnal T60 integrates the Monnal technology platform which facilitates a rapid transition from emergency to intensive care. sensitive triggers to ensure patient comfort and acceptance of the non-invasive ventilation automatic leak detection and compensation wide range of inspiratory oxygen fractions adjustable apnea ventilation Exhaled CO 2 monitoring Integrated and protected Monnal EVA expiratory valve Monnal T60 turbine: patented technology efficiency peak flow of 230 L/min for effective Optimal Breathing System respiratory support in NIV rapid pressurization to meet respiratory demand of the patient at best silent operation to minimize ambient noise (48 dba at 1 m) FiO 2 adjustment from 21 to 100% Large monitoring zone: ventilation safety 5 hours autonomy Full range of ventilation modes: IV and NIV Ergonomic control knob: quick use Automatic emergency modes

Contact Air Liquide Medical Systems Parc de Haute Technologie 6, rue Georges Besse 92182 Antony Cedex, France Tel.: +33 (0)1 40 96 66 00 Fax: +33 (0)1 40 96 67 00 Non-contractual document: product may change at any time / YN031991 V 2.1 09/2012 / Crédit photo : LeSquare / Getty - Eightcom.fr www.airliquide.com