Digital Holography using a Laser Pointer and Consumer Digital Camera Report date: June 22 nd, 2004



Similar documents
Understanding astigmatism Spring 2003

Rodenstock Photo Optics

Automatic and Objective Measurement of Residual Stress and Cord in Glass

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

Filters for Digital Photography

PDF Created with deskpdf PDF Writer - Trial ::

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Solution Derivations for Capa #14

Lecture 12: Cameras and Geometry. CAP 5415 Fall 2010

Physics 441/2: Transmission Electron Microscope

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

Motion Activated Camera User Manual

White paper. In the best of light The challenges of minimum illumination

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

The Basics of Scanning Electron Microscopy

Digital Image Requirements for New Online US Visa Application

Beginners Guide to Digital Camera Settings

The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic

9/16 Optics 1 /11 GEOMETRIC OPTICS

Alignement of a ring cavity laser

Color holographic 3D display unit with aperture field division

How does my eye compare to the telescope?

Scanners and How to Use Them

Infrared Viewers. Manual

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Endoscope Optics. Chapter Introduction

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

Introduction to 3D Imaging

Interference. Physics 102 Workshop #3. General Instructions

TVL - The True Measurement of Video Quality

Telescope Types by Keith Beadman

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

What is a DSLR and what is a compact camera? And newer versions of DSLR are now mirrorless

EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS

EF24-105mm f/4l IS USM

Digital Camera Glossary

Light and its effects

EF-S18-55mm f/ IS II COPY ENG. Instruction

Lens Profile Generator

LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003.

Rodenstock Photo Optics

EVIDENCE PHOTOGRAPHY TEST SPECIFICATIONS MODULE 1: CAMERA SYSTEMS & LIGHT THEORY (37)

MACRO PHOTO LENS. MP-E 65mm f/ ENG. Instruction

Overview Image Acquisition of Microscopic Slides via Web Camera

How an electronic shutter works in a CMOS camera. First, let s review how shutters work in film cameras.

Using the Olympus C4000 REV. 04/2006

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

4. CAMERA ADJUSTMENTS

Digital Photography. Digital Cameras and Digital Photography. Your camera. Topics Your Camera Exposure Shutter speed and f-stop Image Size Editing

OmniBSI TM Technology Backgrounder. Embargoed News: June 22, OmniVision Technologies, Inc.

Defog Image Processing

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Digital Image Basics. Introduction. Pixels and Bitmaps. Written by Jonathan Sachs Copyright Digital Light & Color

WHICH HD ENDOSCOPIC CAMERA?

D/N VARI-FOCAL IR CAMERA

WHITE PAPER. Are More Pixels Better? Resolution Does it Really Matter?

Shutter Speed in Digital Photography

EF-S18-135mm f/ IS

Digital Video-Editing Programs

Handheld USB Digital Endoscope/Microscope

Theremino System Theremino Spectrometer Technology

Contents OVERVIEW WORKFLOW PROBLEM. SOLUTION. FEATURE. BENEFIT 4 5 EASY STEPS TO CALIBRATE YOUR LENSES 5

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

Chapter 17: Light and Image Formation

Imaging techniques with refractive beam shaping optics

Synthetic Sensing: Proximity / Distance Sensors

THE IMPOSSIBLE DOSE HOW CAN SOMETHING SIMPLE BE SO COMPLEX? Lars Hode

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

Untangling the megapixel lens myth! Which is the best lens to buy? And how to make that decision!

Digital Photography Composition. Kent Messamore 9/8/2013

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

300K Pixels Digital Camera

Application Report: Running µshape TM on a VF-20 Interferometer

MRC High Resolution. MR-compatible digital HD video camera. User manual

Beyond Built-in: Why a Better Webcam Matters

EF70-300mm f/4-5.6 IS USM

ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution

BASIC EXPOSURE APERTURES, SHUTTER SPEEDS AND PHOTO TERMINOLOGY

Care and Use of the Compound Microscope

Users Manual Model # English

Measuring the Point Spread Function of a Fluorescence Microscope

Spectroscopy Using the Tracker Video Analysis Program

A Proposal for OpenEXR Color Management

THE COMPOUND MICROSCOPE

Adobe Lens Profile Creator User Guide. Version 1.0 Wednesday, April 14, 2010 Adobe Systems Inc

Master Anamorphic T1.9/35 mm

Links. Blog. Great Images for Papers and Presentations 5/24/2011. Overview. Find help for entire process Quick link Theses and Dissertations

Understanding Depth Of Field, Aperture, and Shutter Speed Supplement to Mastering the Nikon D7000

Fast Track to Wireless Speedlights

Planetary Imaging Workshop Larry Owens

Optical laser beam scanner lens relay system

White Paper. "See" what is important

Experiment 3 Lenses and Images

18-270mm F/ Di II VC PZD for Canon, Nikon (Model B008) mm F/ Di II PZD for Sony (Model B008)

STAAR Science Tutorial 30 TEK 8.8C: Electromagnetic Waves

Transcription:

Digital Holography using a Laser Pointer and Consumer Digital Camera Report date: June 22 nd, 2004 by David Garber, M.E. undergraduate, Johns Hopkins University, dgarber1@jhu.edu Available online at http://pegasus.me.jhu.edu/~lefd/shc/lpholo/lphindex.htm Acknowledgements Faculty sponsor: Prof. Joseph Katz, katz@titan.me.jhu.edu Project idea and direction: Dr. Edwin Malkiel, malkiel@titan.me.jhu.edu Digital holography reconstruction: Jian Sheng, jiansh@titan.me.jhu.edu Abstract The point of this project was to examine the feasibility of low-cost holography. Can viable holograms be recorded using an ordinary diode laser pointer and a consumer digital camera? How much does it cost? What are the major difficulties? I set up an in-line holographic system and recorded both still images and movies using a $600 Fujifilm Finepix S602Z digital camera and a $10 laser pointer by Lazerpro. Reconstruction of the stills shows clearly that successful holograms can be created with a low-cost optical setup. The movies did not reconstruct, due to compression and very low image resolution.

Garber 2 Theoretical Background What is a hologram? The Merriam-Webster dictionary defines a hologram as, a three-dimensional image reproduced from a pattern of interference produced by a split coherent beam of radiation (as a laser). Holograms can produce a three-dimensional image, but it is more helpful for our purposes to think of a hologram as a photograph that can be refocused at any depth. So while a photograph taken of two people standing far apart would have one in focus and one blurry, a hologram taken of the same scene could be reconstructed to bring either person into focus. The advantage of holography lies mainly in small-scale applications. When you take a photograph of a room, many things are in focus (like your roommate, his desk, and the wall behind them). The depth of objects in focus is called the 'depth of field'. So in a large-scale photo the depth of field might be several meters. The depth of field is related to the smallest resolution of the image, and when the resolution becomes much smaller, the depth of field becomes even more dramatically small. So on the microscopic level the depth of field might be on the order of microns! This is where holography is at a huge advantage, because the image can be refocused at any depth ('any' depth is not truly accurate; the depth of field that can be focused is around 100 times greater). How do you record a hologram? {The basic components of a holographic system are the laser, lenses and camera.} The most common method of holography is called "in-line" holography, logically because all of the components are in a line. The image you get is actually the shadow of whatever lies in your field of view, so you cannot see the color of an object using this method.

Garber 3 The laser light provides all of the illumination, and other lights will detract from the quality of the hologram, so all of the images in this paper were taken in a mostly-dark room. The laser light must first be expanded and then collimated (i.e. parallel, the beam is not expanding or focusing) **. When the light passes through the test section, some of it hits objects and deflects, but some passes straight through. Other objects, such as dust on the lenses, will also deflect light. The combination of the direct light (this is called the Reference beam) and the deflected light hitting the recording medium creates an 'interference pattern', if the beams are coherent. The light that hit an object must travel further than the light that just went in a straight line. If this distance is greater than the coherence length of the laser, the two signals will be out of phase and the interference pattern will not appear. Coherence should almost never be a problem with in-line holography because the difference between the distance traveled by the signal and reference beams is very small (< 1cm). This is why a laser pointer is sufficient to produce in-line holograms. Other types of holography, such as off-axis recording, separate the reference beam from the signal beam before the light passes through the test section. If the paths traveled by the two beams are dramatically different, coherence can be a problem. Another reason why in-line holography is possible with a laser-pointer is the power required. Since you are only casting a shadow, the light does not have to be very bright. Other methods of holography (off-axis, back-scattering) record the light reflected from objects. This requires much more illumination! ** Holograms can also be created using an expanding laser beam, but the magnification will vary with depth and this must be compensated for in the reconstruction program. DigiHoloWin does not compensate for this effect so you must use a collimated beam, or write your own reconstruction program! See next section, How do you reconstruct a hologram?

Garber 4 The spacing of the interference pattern is the information used to reconstruct the hologram. The result is a photograph that can be refocused at different depths, rather than being in focus at only one position. The laser light needs to cover the entire imaging area, which is why it is expanded at the start. This is also why a camera lens is not needed; you don't want to focus the light from infinity to a point, instead you want it to cover the entire recording medium. How do you reconstruct a hologram? {Reconstructing a hologram means to bring it into focus at a specific depth.} I have been careful to say recording medium thus far, meaning either film or, for a digital camera, a CCD chip. Holograms can be recorded on special semi-transparent holographic film, however the film is expensive, difficult to develop (and often dangerous because of the chemicals used!), and requires a holographic system matching the one used to record in order to reconstruct. Digital holograms are saved as a file directly and reconstructed using a computer program. They are simpler to record and reconstruct, and astronomically cheaper, however resolution is much lower than with holographic film. You could also create holograms using a normal film camera and then a scanner to create a digital file, however from this point on I will assume a digital camera is being used. Digital reconstruction is accomplished using Fourier transforms. For more information on this, contact Jian Sheng. He wrote the program that was used to reconstruct all of the holograms in this project. It reconstructs one image at a time by calculating the appropriate filter for a given depth, wavelength of light, and resolution (microns/pixel). This filter is convolved over the entire

Garber 5 image, generating one point per filter position, to create the reconstructed image. It currently only operates on grayscale images, so color images must first be converted using a program like Videomach 2. You can download 'DigiHoloWin' (which includes the program as well as a Windows interface) at http://pegasus.me.jhu.edu/~lefd/shc/lpholo/digiholowin.zip Eventually we will have a help file to explain the data field entries; in the meantime you can contact us for more information. Note that this program is the property of Jian Sheng- all rights reserved. Please contact us if you plan to use it. Experimental Setup Components: optical rail, mounts, power supply, laser pointer, neutral density filters, lenses, test section, camera The beam source is a $10 laser pointer by "Lazerpro". The batteries ran out on the first day so after that it was connected to a variable power supply set at 4.5v. Wavelength = 650 +/- 10nm, Power Output < 5mW, Power Consumption = 0.3mW The beam is first dimmed using Neutral Density (ND) filters, because initially it was over-saturating the camera. I usually used an OD (Optical Density) value of around 3.5 to get a

Garber 6 bright image. This is a surprisingly high value, but using less would oversaturate the image in some places. The beam is then expanded using a concave lens. This makes it look like the light is expanding from a point source located at the focal distance of this lens (closer to the laser, see diagram). The collimating lens is placed at its own focal distance away from the point source. So the distance between the lenses is the focal length of the collimating lens minus the focal length of the expanding lens. Part of the beam was weak, so I used an aperture to block some of the dim area. The test section was a small plastic bottle with flat sides. To figure out where to place it, I moved a test pattern slowly towards the camera until it came into focus (this is the zero point for reconstruction). Theoretically it could be placed anywhere between the collimating lens and the camera, but moving it as close as possible to the camera reduces losses. Ideally I would have taken the lens off of the camera and just had the light impact the CCD chip directly; however since that was not possible with the Fujifilm Finepix, I added another lens directly in front to counter-act the effect of the camera lens. It was impossible to know the exact location of the chip or the lens in the camera, so this was an approximation. The lens system has an identical effect to moving the CCD chip to the 'zero point' mentioned above and adding a magnification factor (without a lens system, the zero point would be the CCD chip itself and the magnification factor would be 1). To determine the resolution (microns/pixel) and magnification I took images of a target section- see Calibration.

Garber 7

Garber 8 Calibration For reconstruction, the resolution of the images (microns/pixel) must be known. It is easily determined by shooting a test section, for both movie and still capture mode: Frame from mjpeg (movie) taken at 640x480 Tiff image (still) taken at 2832x2128 As you can see, the field of view is the same in both images, so the smaller resolution image still uses the whole CCD chip and just drops pixels (meaning the pixel spacing is much larger!). The large circles on the test pattern have a 0.5mm diameter and 1mm spacing. The small circles on the test pattern have a 0.25mm diameter and 0.5mm spacing. By simply drawing a line on each image and counting the pixels: The resolution of the tiff image is 3.6 microns/pixel. Recorded in grayscale. The resolution of the mjpeg image is 16 microns/pixel. Recorded in color. Resolution is not the only factor in the quality of the hologram. The compression routine used to store an image in memory will reduce quality, and the filter used to create a color image effectively outputs only one pixel for every four on the CCD chip! The tiff format used by the Fujifilm Finepix is uncompressed 3, but all other formats are compressed. A 128Mb memory card can hold only five of the large tiff files, however.

Garber 9 I also determined the magnification of the optical setup based on the physical spacing of pixels on the chip, although this has no impact on the experiments. The CCD chip for the Fujifilm Finepix S602Z is listed as '1/1.7'. This number refers to the diagonal of the chip, but is based on an extremely outdated convention 4. I approximated the diagonal of the 1/1.7" chip by taking the diagonal of the 1" chip (which is 16mm) and dividing that by 1.7 to get 9.4mm. If you have noticed, the name of the chip ("One inch") does not correspond to any direct measurement. The width/height ratio of the chip is 4/3, so applying the Pythagorean Theorem gives a chip size of 7.5 x 5.6 mm. The chip contains approximately 3.1 million pixels 5, which corresponds to a pixel spacing of 3.7 microns/pixel. The Fujifilm SuperCCD chip has hexagonal pixels 6, so the rows are all oriented at 45 degrees (see diagram). The camera interpolates to create a larger 6 megapixel image. This image is like having a chip with 2.7 microns/pixel spacing (only not as good!). (see endnote 5) The high quality tiff images I took of the test section had a resolution of 3.6 microns/pixel, so the magnification of this optical setup was 2.7/3.6 = 0.75

Garber 10 Data We now have the necessary information to reconstruct holograms we will record. See Theoretical Background, How do you reconstruct a hologram? for a description of the reconstruction technique. Test specimens were obtained from the Chesapeake Bay, at Fort Howard park on Sparrows Point. Still Images The tiff image below was recorded at a resolution of 3.6 microns/pixel (see Calibration) Original size is 2832x2128, Grayscale. In the lower left corner is a Daphnia, also known as a water flea. I reconstructed the image in depth from 0-15mm in increments of 250 microns. See Appendix A for specific camera settings and program data entries.

See all 60 reconstructed images at http://pegasus.me.jhu.edu/~lefd/shc/lpholo/stills.htm Garber 11

Garber 12 Movies Below is a frame from an mjpeg movie recorded at 30fps and resolution 16 microns/px. Original size is 640x480, Color. The movies could only be taken in color and saved in an mjpeg avi format; I converted them to grayscale in Videomach 2 after downloading an mjpeg DirectX codec 7 (already included on Windows XP). I reconstructed the Daphnia in the lower right of the image in depth from 0-15mm in increments of 250 microns, however none show the creature in focus. See Appendix B for specific program data entries. Download a sample movie at http://pegasus.me.jhu.edu/~lefd/shc/lpholo/fuzzymovie.avi This is the original (not reconstructed) file except already converted to grayscale. Even though it does not focus, it does show the behavior of the Daphnia.

Garber 13

Garber 14 Results and Conclusions The point of this project was to examine the feasibility of low-cost holography. Can you record viable holograms? How much does it cost? What are the major difficulties? The reconstructed still images in the Data section of this paper show the success of this experiment. The daphnia does clearly come into focus, and although I have seen much nicer images generated by the high-level systems in our lab, this is not bad. In the close-up image set as well as the full frame (available online), you can see other objects coming into focus, notably several small particles near to the Daphnia in our field of view, located at 3mm and 9mm depths. I was most interested in recording movies of the plankton, however the resolution of movies recorded with this camera was just not good enough. If the lenses were moved in order to magnify the target significantly, it may be possible to get better results. Not being able to remove the camera lens was a major hindrance, because it required another lens to counteract it, made calculating the magnification a tricky proposition, and prevented me from being able to see for certain whether the laser light was collimated, expanding or focusing when it hit the CCD. The laser pointer itself is the cheapest part of this system- only $10! It has a coherence length sufficient to produce a distinct interference pattern (unlike LEDs), which is what we need for holography. The manufacturer of this specific laser pointer is Lazerpro. Lenses similar to the expanding and focusing lenses used in this system can be obtained for around $50. The large collimating lens I used is a different matter- it costs hundreds of dollars. This is not a fatal problem however, because a smaller diameter lens can be used and the field of view will just be smaller. An optical rail and mounts to hold the optical elements could cost another $100 or less.

Garber 15 I used the Fujifilm Finepix S602 because it was available. It sells for around $600 online. It has some very nice features (the SP mode lets you record black and white still images, which reduces compression and saves the trouble of converting them from RGB later). A removablelens digital camera would be ideal, as I mentioned above. A higher resolution movie mode is also very desirable. Assuming you already have a digital camera or can borrow one, you can build a laser pointer holography system for $300. This is the major advantage to digital holography- no expensive film and no strange (and sometimes carcinogenic) developing procedures. In the future, low cost submersible holographic systems could be deployed routinely by biologists to monitor plankton in their natural environment. The only hindrance is currently the camera, and high resolution digital cameras are becoming cheaper everyday. Soon even cellphone cameras might be used for holography!

Garber 16 References 1. The three-dimensional flow field generated by a feeding calanoid copepod measured using digital holography, The Journal of Experimental Biology, 2003 Edwin Malkiel, Jian Sheng, Joseph Katz, and J. Rudi Strickler http://jeb.biologists.org/cgi/content/abstract/206/20/3657 2. Videomach by Gromada http://www.gromada.com/videomach.html 3. Fujifilm Finepix, Tiff format http://www.finepix.de/en/3_300_1017754714.html 4. Digital Photography Review, Sensor Sizes http://www.dpreview.com/news/0210/02100402sensorsizes.asp 5. Fujifilm, Finepix S602Z manual http://www.fujifilm.com/jsp/fuji/epartners/bin/re2-webfps602z2p_1_1_1.pdf 6. Fujifilm, 3rd generation Super CCD chip specifications http://www.fujifilm.com/jsp/fuji/epartners/bin/3rdgensuperccd_2.pdf 7. Windows Media Player, FAQ http://www.nwlink.com/%7ezachd/pss/pss.html - mjpeg

Garber 17 Appendix A. The still images were captured with the Fujifilm Finepix S602Z fully zoomed in and set to SP mode, Black and White, Manual Focus, max resolution (2832x2128 Tiff format). DigiHoloWin reconstruction program: Here the input image file is named Dsc_001.tif

Garber 18 B. The movies were captured with the Fujifilm Finepix S602Z fully zoomed in and set to movie mode, VGA output, only available file size 640x480 avi. Focus is set just before recording. I converted the movie to a list of grayscale tiff files in Videomach 2 before running this program (required). DigiHoloWin reconstruction program: Here the input image file is named A_000.tif