... Electronic Softstarter...



Similar documents
Torque control MSF Softstarter

3753 en /b VE/B - VE/RG Va V riable speed drives

Bulletin 150 SMC Flex Smart Motor Controller Specifications

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Phone: Fax: Web: info@clrwtr.com

Easy to connect - Easy to configure Easy to install

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

MOTOR CONTROL IS OUR NATURE

BIG SAVINGS FOR A LOT MORE APPLICATIONS

Permissible ambient temperature Operation Storage, transport

Softstarters Type PSR

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

32VFD Variable Frequency Drives for Centrifugal Chillers


MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Electric Rotary Actuator - On/Off or programmable control actuator

Smart relays Zelio Logic Step into an intuitive world!

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

1 Application Description Objective Goals... 3

Softstarters. Type PST/PSTB Fieldbus communication CANopen for PST sw CU SFC132070M0201 February SFC132070M0201 1

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

ACS800. Firmware Manual ACS800 Standard Control Program 7.x

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Panorama. Softstarters The complete range

NXL Series Inverters. HVAC Inverters made simple

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

SERIAL INTERFACE. Series SSW-03 and 04

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

WIND TURBINE TECHNOLOGY

Programmable Logic Controller PLC

Number 1 in efficiency

Rack mounted telephone- and leased line modem for industrial applications

Telephone- and leased line modem for industrial applications TD-36

Products and solutions for lifting systems

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Programming Logic controllers

M2M The measure of efficiency

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

Frequency Converter Fv

SJ200 Series Inverter Quick Reference Guide

Voltage Regulator SPAU 341 C. Product Guide

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

SYSTEM 4C. C R H Electronics Design

Vibration Monitoring System Adash 3600

GPD 506/P5 Start-up Procedure and Checklist

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

ACS800. Firmware Manual ACS800 Standard Control Program 7.x

AIS750 Series Alarm Annunciator

WIND Power Technology: IMD Integrated Motor Drive

ABB drives. Automation solutions Drives, PLC, motion, motors and safety

EDI Distributor Control Interface Wiring and Setup Instructions

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Safety technique. Emergency stop module BO 5988 safemaster

T Substation Maintenance and Commissioning Test Equipment

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

DEPARTMENT OF COMPUTER SCIENCE & ENGINEERING Question Bank Subject Name: EC Microprocessor & Microcontroller Year/Sem : II/IV

PRODUCT LIST Facility DDC Access WebXL DDC

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

LIFT CONTROL SYSTEMS CATALOGUE 2007

Three-phase monitoring relay CM-PFE

Supplement to the Operating Instructions for SIMOREG DC-MASTER Series 6RA70. for Software Release 3.2. Version 13 Order no.

User Manual. AS-Interface Programmer

POINTS POSITION INDICATOR PPI4

Barcode Reader Series BCL 31, BCL 32, BCL 34

Using installed Fieldbus Wiring to carry Ethernet Communications

with Electronic Assistant

SECTION VARIABLE FREQUENCY DRIVES

EXPERTS IN WATER COOLING SINCE aquastream ULTIMATE SUPER SILENT PUMP TECHNOLOGY. The ultimate pump system.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

SYSTEM 45. C R H Electronics Design

2.24. Pump Controller 704. Data Sheet

PLC Based Liquid Filling and Mixing

GE Industrial Solutions ASTAT BP. User Manual

ABB general machinery drives. User s manual ACS355 drives

Install the DeviceNet Module using the following procedure:

Siemens AG 2009 MICROMASTER. The universal frequency inverter for drive technology. Brochure April 2008 MICROMASTER.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Multi-Range Programmable DC Power Supplies 9115 Series

How to design an insulin pump

Industrial Automation Training Academy. PLC, HMI & Drives Training Programs Duration: 6 Months (180 ~ 240 Hours)

40.3. Control Relays and Timers

Drives 101. Functions of an Adjustable Frequency Drive (AFD) This lesson covers the basic functions of an Adjustable Frequency Drives (AFD).

Multifunction devices

Achieving the impossible

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

A project to optimise quality and energy efficiency must include metering

Transcription:

. CT-START Electronic Softstarter. 6 A. to 900. A.........

CT START CT-START is a multi-function electronic system with a microcontroller and thyristors, designed for use with all 3-phase squirrel cage induction motors. Unlike the traditional systems (, star-delta, resistors, etc), it limits the starting current and ensures very smooth and steady acceleration. CT-START includes protection and control system functions which means that installations are kept simple and costs are reduced. 5 year return to base warranty current limitation During this phase, all traditional starter systems cause I D /I N I D /I N a current peak, which can vary between 6 and 9 7 7 times the rated current. CT-START, by simple adjustments, can limit the current precisely during the start-up phase, whilst maintaining all the thermal characteristics of the motor. 6 5 4 3 6 5 4 3 CT-START CURRENT CURVE CURRENT CURVE smooth starting Starting a motor generates surges, vibrations, imbalances, C D /C N Resistive torque C D /C N Resistive torque slackening, pressure surges, and mechanical stress..5.5 CT-START's electronic design means that it can be used for precise adjustment of the starting and repeated torque. It ensures smooth acceleration, thus limiting the forces to which the installations are subjected..5 0.5.5 0.5 CT-START TORQUE CURVE TORQUE CURVE integral protection Starting, protecting and automating systems require the L L L3 L L L3 installation of a large number of components, which means that the control boxes are both complex and big. KM 3 5 3 5 3 5 CT-START has several supplementary functions which can limit the purchases of additional equipment, thus resulting in a reduction in the cost of materials, labour and operation. An increase in motor control reliability is obtained by simplifying the installation. KM KM3 KM 4 6 4 6 4 6 U V W 3 5 Rth 4 6 U V W CT-START U V W

power ratings CTS 3 6-0 - 6 - - 30-44 A. KW (400 V) kw Compact dimensions Modular design marked CTS 33 37-60 - 86-45 - - 50-365 - 530-700 - 900 A 8.5 KW (400 V) 500 kw example of referencing CT-Start CTS 33 4 37: model 33 voltage 0-500 V, current rating 37 A Version 4 Version 6 0 V 500 V 690 V Wide homogeneous range -. to 500 kw (400 V). - up to 900 kw, 690 V. Multi-voltage units CTS 3 and 33 can be used over a wide voltage range: logical organisational diagram of the starter L L L3 MAINS SUPPLY THYRISTOR POWER MODULE U V W MOTOR 30 400 N/L INDEPENDENT ELECTRONIC POWER SUPPLY MAINS SYNCH. CURRENT FEEDBACK THYRISTOR CONTROL PARAMETER ENTRY AND DISPLAY MODULES RS 485 SERIAL LINK EXTENSIONS OPTIONS PROGRAMMABLE RELAYS 6 BIT MICROCONTROLLER RUN RESET TERMINAL RAM THERMAL CALCULATIONS EPROM OPERATING PROGRAM EEPROM PARAMETER BACKUP digital techlogy Control electronics independent of the power rating Protection against interference: Increased immunity of the microcontroller - IEC 80 and IEC 80-4 level 4. Updatable operating program under EPROM Permanent parameter backup under EEPROM

CDC - START PAR RUN MODE MEM. STOP RESET C U R R E N F A U L T - C U F A U L T - P O W E R : 9 7 % P N P W R. F A C T O R : 0. 8 7 C U R R E N T : 5 0 A O P E R A T I N G : 3 5 5 9 H ES START I/O MODULE logic inputs - management of external faults, - or multi-parameter entry: starting several motors, -speed motors, -load or on-load starting. logic outputs - can provide 4 alarm relays analogue input PTC input (6 probes) analogue outputs - can provide feedback relating to the current or the power drawn by the motor. RV START SPEED FEEDBACK CONTROL MODULE The RV-START module, when used with the CT-START CTS, controls the speed feedback in order to ensure smooth repetitive starts, whatever the load of the machine being driven. Applications: installations where the starting load varies considerably (conveyors, bucket elevators, mixers, ball mills, etc.) The RV-START module also has a logic input which allows for the double entry of CT-START parameters when it is being used with a -speed motor. 3 types of speed feedback, - D.c. or a.c. tacho, - 3-wire proximity sensor, - 4-0 ma signal. options CTS 33 CDC START TERMINAL The CDC START terminal has 8 keys, LED and 3-character LCD, and is designed for starters in the CTS 33 range. When used with the base model, it: is used for programming, diagstics and displaying the parameters, provides clear displays concerning the operation of the motor, accesses additional functions: - saving a set of parameters, - limiting the number of starts, - locking the settings using a personal code, - additional, more precise settings, - entering option parameters, etc. FR START D.C. INJECTION MODULE Braking before starting, Braking on deceleration, Keeping the motor free from condensation, Drying the motor. OTHER OPTIONS Quick-blow fuses, optional on ratings 50 A, and standard on ratings 365 A. IP 0 kit on ratings 50 A. IP 53 version. Starter enclosure. Connection kit. Autotransformer.

Made by Control Techniques Communications CT-START type CTS 4 37 Serial number 000000000000 PARAMETER SETTING SET UP STARTING OPTIONS Speed feedback option I/O extension option Braking option Communication option PROTECTIONS DECELERATION RELAY SETTING PC START COM - START SETTING ON LINE CDC - START CTS 33 NETWORK INPUT NETWORK OUTPUT PC START Software for programming via a P.C. - saving parameters, - adjustment assistance, etc. COM START MODBUS interface for installing CT-START on a network. RS 485 port programmable electrical characteristics : - transmission speed, - parity, etc.