Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

Similar documents
HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Telephone- and leased line modem for industrial applications TD-36

Preset Counter signo 721

Quick Connect. quick - simple - efficient.

Analog signal converters CC-E I/I Current / current isolators

is then retained absolutely without interruption.

Rack mounted telephone- and leased line modem for industrial applications

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

TX OPEN RS232/485 module

Digital input modules

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Duct Humidity Transmitter

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Contents. Document information

TMS TANK MANAGEMENT SYSTEM

Redundancy Module QUINT-DIODE/40

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Modular I/O System Analog and Digital Interface Modules

G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to make technical changes at any time without notice.

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

MINI MCR-SL-R-UI(-SP)

PHOENIX CONTACT Features

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Three-phase monitoring relay CM-PFE

User Manual Weather station V 0.2

WEB log. Device connection plans

PCS0100en Persy Control Services B.V. Netherlands

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

WEB log. Device connection plans

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Rosemount 333 HART Tri-Loop

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

IO-RM3 3-Stage Relay Module

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

T0118 T2118 T3118. Instruction Manual

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Multifunction devices

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

GREISINGER electronic GmbH

DMX2PWM 9 Channel Dimmer Setup Manual

Adjustment functions for both span and shift have been incorporated

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Operating Manual UWAPS-TINY Series

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Series 7500 Torque Sensor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Power Supplies 3. SDN-P DIN Rail Series

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

1 Technical Description Lokal-200PC

49 Series - Relay interface modules A. Features

Drayton Digistat +2RF/+3RF

MILE Encoder for EC 90 flat

SYSTEM DESCRIPTION Termination Boards

Hand-held thermometer Model CTH7000

Original instructions Tina 3A/Aps Adaptor unit

48 SERIES Relay interface modules 10 A

Current Monitoring Kit

Electronic Pressure Switch EDS 300

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

EIB/KNX IP Interface with Power over Ethernet (PoE)

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

How To Power A Schen

Product and functional description

Installation guide H A. HSI hardwired system interface

connecdim Gateway G1 Ethernet TCP/IP to DALI

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Rosemount 333 HART Tri-Loop

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Description. Dimensions. Features. precision works better

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Tina 2A/B Adaptor unit

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

RS - SPM. Serial parallel translator module

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Combi switchbox with integrated 3/2 way pilot valve

CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor

Transcription:

Order Number: 8160.UANA Status: V6; 1425.03.2010 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1

TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 ANACON UMB ANALOGUE/DIGITAL CONVERTER... 6 CONFIGURATION... 10 INSTALLATION AND COMMISSIONING... 11 SENSOR CHANNEL LIST... 13 TECHNICAL DATA... 16 MAINTENANCE AND CARE... 20 DISPOSAL... 20 MANUFACTURER... 20 EC CERTIFICATE OF CONFORMITY... 21 Version history: Version Date Compiled by Comments V1 15.09.2006 EES/SH First edition V2 11.01.2007 EES Sensor connection scheme for wind sensor changed; additional channels for wind speed in knots supplemented V3 27.03.2007 EES EC Certificate of Conformity and channels for abs. air pressure / humidity supplemented; grounded DIN rail V4 09.10.2007 EES Channel list for precipitation and pulses changed V5 13.07.2009 EES Channel list for 2nd Temperature channel added V6 25.03.2010 FS New Housing 2 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Please read before use Before using the equipment, please read the operating manual carefully and follow the instructions in every detail. Safety instructions Installation and commissioning must only be carried out by suitably qualified specialist personnel. Never take measurements on or touch live electrical parts. Only mount the module on the DIN rail when the power is switched off. Protect the device from direct sunlight The equipment requires an adjustment period of several minutes on being moved to a location with different climate conditions. Pay attention to the technical data and storage and operating conditions. Designated use The equipment must only be operated within the range of the specified technical data. The equipment must only be used under the conditions and for the purposes for which it was designed. The safety and operation of the equipment can no longer be guaranteed if it is modified or adapted. Guarantee The guarantee period is 24 months from the date of delivery. The guarantee is forfeited if the designated use is violated. G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 3

Symbols used Important indication concerning possible hazards to the user Important indication for the correct functioning of the device 4 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Description The UMB Analogue/Digital Converter (ANACON) is an intelligent analogue/digital converter with electrical isolation, suitable for integration into UMB networks. The devices are easily installed on standard EN mounting rails and networked together by means of mounting rail bus connectors. The 24V feed for the power supply takes place via the bus connector. Windows software is available for the configuration of the ANACON via RS232 port and an additional ISOCON (8160.UISO). Features 2 analogue inputs with 24 bit resolution and signal conditioning for resistance, PT100/PT1000, voltage, current, frequency and pulses as well as pre-defined settings for a large number of Lufft environmental sensors. A half-duplex RS485 interface for networking the converters together. Easy mounting on standard EN mounting rails Easy networking of up to 32 subscribers via mounting rail bus connectors 24V DC power supply suitable for switchgear cabinets ESD protection for all interfaces Configuration via Windows software provided Functions displayed via LED s Low space requirement; width approx. 23mm/module Low energy consumption / dissipation G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 5

ANACON UMB Analogue/Digital Converter Summary Power supply & RS485 bus interface Input Channel A Input Channel B Status LED s 6 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Analogue Inputs Channel A and Channel B Channel B PIN Name 1 Power, Sensor Power Supply 2 ANA_+, Sense High Input Channel A 3 ANA_I, Force Low Input 4 ANA_-, Force High Input ANACON-UMB Connection G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 7

Mounting Rail Bus Connector Earth 24V Power Supply, Feed Earth 24V Power Supply, Feed +24V Power Supply, Feed B1, Internal Bus A1, Internal Bus NOTE: The assembly must take place on a grounded DIN rail! 8 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Status LED s There are 2 LED s on the front side of the device in order to display the correct configuration and functioning of the ANACON. Their meanings are as follows: Red LED: Green LED: - If this LED lights up permanently after switch-on there is a configuration fault. - If this LED lights up during operation an unforeseen fault has occurred; the device must be reset. - This LED flashes briefly (20ms) every 10 seconds to display the function of the device. - This LED lights up for a longer period (>500ms) during measurement. G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 9

Configuration The ANACON modules are all supplied from the factory with ID 1. If several modules are installed in a UMB network, it must be ensured that all modules on the network have a different ID. The following steps should be taken in order to configure the device: 1. Clip a mounting rail bus connector onto the Din rail and connect the 24V supply with the aid of the connector provided. Please ensure that the polarity and pin assignment are correct on connection. Incorrect connection can cause the destruction of the ANACON module! 2. Next mount the ANACON module which you wish to configure. 3. For the connection to the RS232 port of your PC a additional ISOCON (8160.UISO) is necessary. Clip the ISOCON also on the mounting rail and connect the module to your PC via the RS232 interface. 4. Set the desired ID and channel configuration using the UMB-Config-Tool software. You can enter the configured ID in the inscription field on the front side of the module. 5. The ANACON is now ready for operation and can be detached from the DIN rail. Please repeat steps 2 to 5 for all additional ANACON modules. 10 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Installation and Commissioning 1. First configure all the modules using the UMB-Config-Tool configuration software in accordance with your requirements (see Configuration chapter). 2. Clip the required number of mounting rail bus connectors onto the DIN rail and then connect all the ANACON modules. 3. Connect the sensors to channels A and B of the ANACON module. Please note that a fixed assignment is specified for channels A and B for the combined sensors for temperature and relative humidity as well as the wind speed and wind direction sensors. A summary of the sensor connection scheme is provided in the table below. 4. Now connect the 24V power supply to the mounting rail bus connectors. 5. Connect your host system to any desired ISOCON RS232 interface. The equipment is now ready for operation. ATTENTION: Only mount or remove modules from the DIN rail when the power is switched off The assembly must take place on a grounded DIN rail! Connecting the ANACON modules to the DIN rail G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 11

8160.UANA Channel A Channel B Input Pin1 Pin2 Pin3 Pin4 Pin1 Pin2 Pin3 Pin4 Resistance (3 wire), PT100/PT1000 Voltage V+ V- V+ V- Current self powered I- I+ I- I+ Current ANACON powered I+ I- I+ I- Frequency F- F+ F- F+ Impulse/ Digital Input D- D+ D- D+ Lufft Sensors 8160.TF (T) red red white red red white 8160.TFF (T/H) brown orange black red yellow 8355.03 (Baro) red orange red orange 8368.01 (WS/WD) orange black black brown brown black 8352.USH4M/US6M blue brown blue orange 8353.02/4/5 brown orange brown orange Table: Sensor connection scheme 12 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Sensor Channel List Channel assignment equipment class 6 universal measurement transmitters UMB Channel Measurement Range Act Min Max Avg Special Input Variable Min Max Unit Temperature 100 120 140 160 A temperature -200.0 450.0 C 105 125 145 165 A temperature -328.0 842.0 F 101 121 141 161 B temperature -200.0 450.0 C 106 126 146 166 B temperature -328.0 842.0 F 110 130 150 170 dewpoint -200.0 450.0 C 111 131 151 171 dewpoint -328.0 842.0 F Humidity 201 221 241 261 B relative humidity 0,0 100,0 % 206 226 246 266 B absolute humidity g/m² 211 231 251 271 B mixing ratio g/kg Pressure 300 320 340 360 A air pressure 0 1200 hpa 305 325 345 365 A abs. air pressure 0 1200 hpa 301 321 341 361 B air pressure 0 1200 hpa 306 326 346 366 B abs. air pressure 0 1200 hpa G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 13

Wind Vect. avg 400 420 440 460 480 A Wind Speed 0 100.0 m/s 405 425 445 465 485 A Wind Speed 0 360.0 km/h 410 430 450 470 490 A Wind Speed 0 223.7 mph 415 435 455 475 495 A Wind Speed 0 194,4 kts 501 521 541 561 581 B Wind Direction 0 359.9 Precipitation 600 A precipitation absol. mm 601 B precipitation absol. mm 620 A precipitation diff. mm 621 B precipitation diff. mm 640 A precip. intens. mm/h 641 B precip. intens. mm/h Digital input 700 720 740 760 A Digital Input 0 1 701 721 741 761 B Digital Input 0 1 Voltage 10000 10020 10040 10060 A Voltage 0 1000 mv 10001 10021 10041 10061 B Voltage 0 1000 mv Current 10100 10120 10140 10160 A Current 0 24 ma 10101 10121 10141 10161 B Current 0 24 ma 14 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Resistance 10200 10220 10240 10260 A Resistance 0 2000 Ohm 10201 10221 10241 10261 B Resistance 0 2000 Ohm Frequency 10300 10320 10340 10360 A Frequency 10 10000 Hz 10301 10321 10341 10361 B Frequency 10 10000 Hz Pulses 10500 A impulse absol. 0 65520 pulse 10501 B impulse absol. 0 65520 pulse 10520 A impulse diff. 0 65520 pulse 10521 B impulse diff. 0 65520 pulse G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 15

Technical Data Power supply Power supply 24VDC +/- 10% Power consumption < 50mA at 24V; excluding sensor Connection Phoenix bus connector, gold, 5 pole Function display Green LED, flashes every 10 seconds RS485 interface internal bus Standard RS485 2 wire, half-duplex Transmission type Protocol-transparent, 8 data bits, 1 stop bit, no parity Tri-State 2 bit after stop bit edge Transmission rate 19200 baud Connection Phoenix bus connector, gold, 5 pole, maximum 8A 24V output max. 2 A (note the maximum current of the internal bus) 16 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Measurement Variables Variable Measurement Range Resolution Accuracy (25 C) Voltage 0... 100mV 0.02% of EV +/- 0.1% of m.v. +/- 2 digits Voltage 0... 1000 mv 0.02% of EV +/- 0.1% of m.v. +/- 2 digits Current *1) 0... 20 ma (max: 0.02% of EV +/- 0.1% of m.v. +/- 2 digits 24mA) Current *2) 4 20mA (max: 0.02% of EV +/- 0.1% of m.v. +/- 2 digits 24mA) Resistance 0... 200 Ohm 0.02% of EV +/- 0.1% of m.v. +/- 2 digits Resistance 0... 2000 Ohm 0.02% of EV +/- 0.1% of m.v. +/- 2 digits Temperature with PT100 Temperature with PT1000-200... 500 C 0.02 C for (-50 C<t<150 C) otherwise 0.1 C -200... 500 C 0.02 C for (-50 C<t<150 C) otherwise 0.1 C +/- 0.1 C for (-50 C<t<150 C) otherwise +/- 0.5 C +/- 0.1 C for (-50 C<t<150 C) otherwise +/- 0.5 C Frequency *3) 0... 1000 Hz 0.02% of EV +/- 0.1% of m.v. +/- 2 digits Frequency *3) 0... 10 khz 0.02% of EV +/- 0.1% of m.v. +/- 2 digits Pulses *4) 0... 65520 1 pulse Digital input *5) 0 / 1 1. Shunt resistance 51 Ohms 2. Shunt resistance 51 Ohms, voltage on Pin 1 in ANACON powered mode approx. 12V 3. Pulse duty ratio 50%, internal resistance approx. 500 Ohms, Uhigh>6V, Ulow<3V 4. Pulse length > 100µs, pulse spacing > 100µs, internal resistance approx. 500 Ohms, Uhigh>6V, Ulow<3V 5. Internal resistance approx. 500 Ohms, Uhigh>6V, Ulow<3V G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 17

LUFFT Sensors Sensor Temperature Sensor 8160.TF Temperature/Humidity Sensor 8160.TFF Barometric Air Pressure Sensor 8355.03 Wind Speed and Wind Direction 8368.01 Wind Speed and Wind Direction 8352.USH4M/US6M Rain Gauge with 1mm; 0.2mm; 0.1mm resolution Measurement Variable Measurement Range Physical Variable Physical Measurement Range Temperature PT100-50... 100 C Resistance 60.34 138.5 Ohms Temperature PT1000-30... 70 C Resistance 882.2 1270.8 Ohms Humidity 0... 100 % Frequency RH Air Pressure 0... 1200 hpa Current 4... 20 ma Wind Speed 0.9... 50 m/s Voltage 0-1000 mv Wind Direction 0... 358 Resistance 0 1000 Ohms Wind Speed 0... 60 m/s Current 4-20 ma Wind Direction 0... 359 Current 4-20 ma Precipitation Pulses 0...65620 18 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

Storage conditions Permissible ambient temp. -40... 70 C Permissible rel. humidity 0... 95% RH (non-condensing) Operating conditions Permissible operating temp. -30... 60 C Permissible rel. humidity 0... 95% RH (non-condensing) Housing Material PA-V0, green Width x Height x Depth 22.5 x 99 x 118.6 mm Protection class IP20 Weight approx. 120 g Connections COMBICON plug-in connectors 0.2 2.5 mm² (AWG 24 12) G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 19

Maintenance and Care The product is designed in such a way as to require no maintenance. It does not contain any parts (e.g. batteries) requiring maintenance or exchange. Disposal The device must be disposed of in accordance with European Directives 2002/96/EC and 2003/108/EC (waste electrical and electronic equipment). Waste equipment must not be disposed of as household waste! For environmentally sound recycling and the disposal of your waste equipment please contact a certified electronic waste disposal company. Manufacturer For matters of guarantee or repair please contact: G. Lufft Mess- und Regeltechnik GmbH Gutenbergstraße 20 D-70736 Fellbach Postfach 4252 D-70719 Fellbach Germany Tel: +49(0)711-51822-0 Fax: +49(0)711-51822-41 E-mail: info@lufft.de 20 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

EC Certificate of Conformity Product: Type: Analogue/Digital Converter ANACON UMB (Part No.: 8160.UANA) We herewith certify that the above mentioned equipment complies in design and construction with the Directives of the European Union and specifically the EMC Directive in accordance with 89/336/EC and the Low Voltage Directive in accordance with 73/23/EC. The above mentioned equipment specifically conforms to the following EMC Standards: EN 61000-6-2:2005 Part 6-2: Generic Standards - Immunity for industrial environment EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 ESD RF Field Burst Surge Conducted RF Magnetic Field 50Hz EN 61000-6-3:2001 Part 6-3: Generic standards - Emission standard for residental, commercial and lightindustrial enviroments EN 55022:1998 +A1:2000 +A2:2003 Conducted Interferences pren 50147-3:2000 Radiated Emission Fellbach, 27.03.2007 Axel Schmitz-Hübsch G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 21