Variable Displacement Pump AA10VSO

Variable Displacement Pump A10VSO for open circuits

Axial Piston Variable Pump A10VSO

Axial Piston Variable Pump KVA

Variable Displacement Pump A7VO

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE / for open circuits

Series TMM Axial Piston Motor. Technical Information

Axial Piston Variable Pump A10VSO

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Axial Piston Fixed Displacement Motor A2FM

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Fixed Displacement Pump A2FO

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Series PVP Variable Volume Piston Pumps

Axial Piston Variable Motor A6VM

Fixed displacement vane pumps

Internal gear pump PGF Series 2X and 3X

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

PUMP AND MOTOR DIVISION

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Radial piston pumps type R and RG

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Vickers. Piston Pumps

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Rexroth Hydraulic Pump A10VO Series User Manual

Rickmeier Solutions. Gear pumps for superior Lubrication

PLQE. The base of the economy gearboxes with square output flange. Economy Line. Formerly PLE

Unit 24: Applications of Pneumatics and Hydraulics

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

PVH131/141 Variable Displacement Piston Pump - 11 Design

Pressure reducing valve, direct operated, Type ZDR 6 D

Unit 24: Applications of Pneumatics and Hydraulics

Chapter 5: Flow Valves

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Transfer Gear Pumps KF

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

DATA PD SV13.., SV14.. Levelling Valves. Product. Function. Technical Features. Range Overview

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Flow divider (flow distributor), type TQ

MINEX -S. Magnetic coupling. You will find continuously updated data in our online catalogue at

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

High Pressure Gear Motors KM 1

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

220 Series Piston Pump Typical Applications Features and Benefits


3/2- and 2/2-way cartridge valve type BVE

HMC Series Dual Displacement Staffa Motor

Table of Contents. M Series Variable Displacement Piston Pumps

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK March 2004


Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Pressure and flow control system

Dual Path Mobile Pump

HYDRAULIC MOTORS HYDRAULIC SYSTEMS DIVISION. Outstanding Hydraulic Products, Service and Expertise, Worldwide

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

DuraForce HPV Variable Pumps for Closed Loop Operation

Axial piston variable pump (A)A4VSO

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Highly flexible couplings

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

Open center control block in monoblock design MO-40

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Hydraulic multidisc Brake H420

Machine Design II Prof. K.Gopinath & Prof. M.M.Mayuram. Module 2 - GEARS. Lecture 17 DESIGN OF GEARBOX

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

KDG3V-5/7/8, 10 Series

Hydraulic Control Solutions

Vickers PVM Piston Pumps

PVM Piston Pumps Service Manual

HYDRAULIC MOTORS Concentric AB

GoTo Europe Focused Delivery Program. Product overview industrial and mobile hydraulics

Check Valves Valve locator

Pressure Relief Valves SPV, SPVF

Line rupture protection valves type LB

Vickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment

Electro-hydraulic pressure switches type DG

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Rules for Classification and Construction Additional Rules and Guidelines

MANTA Piston Distributor for Oil and Fluid Grease

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

"A" Series Variable Displacement Piston Pumps Single Pump, "OBE" Type Electro-Hydraulic Proportional Pressure & Flow Control Type

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER

Directional seated valves type VP 1

Hydraulic cylinders Tie rod design. Type CD70 / CG70. Contents. Features. RE Edition: Replaces: 08.08

Transcription:

A10VO Nominal size 18 see RD 92712 A10VO Nominal size 28...140 see RD 92711 The variable displacement axial piston pump A10VO in swashplate design was designed for hydrostatic drives in open circuits. The pump is suitable for use in both stationary and mobile applications. Volumetric flow is proportional to the drive speed and the displacement. y adjusting the position of the swashplate it is possible to vary the flow steplessly. AE and IO mounting flange Compact construction High power-weight ratio ow noise level ower press loss hort control times Pressure and flow control

Variable displacement pump A10VO, eries 52 Type Code A10V O 10 / 52 P N00 Fluid Mineral oil (no desig.) Axial piston unit Variable, swashplate design nominal pressure 250 bar, peak pressure 315 bar A10V Mode of operation Pump, open circuit O ize Displacement V g max (cm 3 ) 10 Control devices Pressure control Pressure-remote control Pressure- and flow control DR DRG DFR1 eries Direction of rotation ooking at driveshaft eals NR (Nitrile rubber to DIN IO 1629) 52 clockwise counter-clockwise R P haft end AE DIN Cylindrical with feather key 19-1(AE A-) Cylindrical with feather key DIN 6885 plined shaft 19-4 (AE A-, 3/4") plined shaft 16-4 (AE A, 5/8") K P U Mounting flange AE 2-bolt IO 2-bolt C A ervice ports AE DIN Pressure port Inlet port UNF-thread rear 64 Pressure port metric thread rear 14 Inlet port Through drive without through drive N00 = prefered program (with short delivery times) = available = not available

Variable displacement pump A10VO, eries 52 Hydraulic fluid Prior to project design, please see our catalogue sheets RE 902 (mineral oils) and RE 90221 (environmentally compatible fluids) for detailed information on the selection of hydraulic fluids and application conditions. When operating with environmentally compatible fluids certain limitations may apply. Please consult us. Operating viscosity range For optimum efficiency and service life, we recommend that the operating viscosity (at operating temperature) be selected in the range ν opt = optimum operating viscosity 16...36 mm 2 /s referred to tank temperature (open circuit). imits of viscosity range The following values are valid for extreme operating conditions: ν min = 10 mm 2 /s for short periods at max. leakage oil temperature of 90 C. ν max = 1000 mm 2 /s for short periods upon cold start. Temperature range (see selection diagram) t min = 25 C t max = +90 C Notes on the selection of the hydraulic fluid For correct selection of the fluid it is assumed that the operating temperature in the tank is known (open circuits), in relation to the ambient temperature. The hydraulic fluid should be selected so that, within the operating temperature range, the operating viscosity lies within the optimum range ν opt, (see shaded section of selection diagram). We recommend that the higher viscosity grade is selected in each case. Example: At an ambient temperature of C the operating temperature in the tank will be 60 C. In the optimum operating viscosity range (ν opt ; shaded section) this corresponds to viscosity grade VG 46 or VG 68; VG 68 should be selected. Important: The leakage oil temperature is influenced by pressure and speed and is always higher than the tank temperature. At no point in the system, however, may the temperature be higher than 90 C. If it is not possible to comply with the above conditions because of extreme operating parameters or a high ambient temperature, please consult us. election diagramm Viskosität Viscosity ν (mm ν (mm 2 /s) 2 /s) 1000 600 400 0 100 80 60 40 15-0 40 60 80 100 1000 VG 22 VG 68 VG 46 VG 32 VG 100 36 16 ν opt 10 10 25 10 10 30 50 70 90 Temperature t ( C) t ( o C) t min = 25 C t max = + 90 C Druckflüssigkeitstemperaturbereich Fluid temperature range Filtration In order to guarantee reliable function, the operating fluid must be maintained to a cleanliness grade of minimum 9 to NA 1638 or 18/15 to IO/DI 4406

Variable displacement pump A10VO, eries 52 Technical Data Operating pressure range - Inlet side Absolute pressure at port (inlet port) p abs min 0,8 bar p abs max 30 bar Operating pressure range - Outlet side pressure at port Nominal pressure p N 250 bar Peak pressure p max 315 bar (Pressure data to DIN 24312) Direction of flow to. Case drain pressure Maximum permissible pressure of leakage fluid (at port, 1 ): maximum 0.5 bar higher than the inlet pressure at port, but not higher than 2 bar absolute. Determination of inlet pressure p abs at the inlet port, resp. the reduction in displacement for increasing speed. peed n/n max 1,2 1,1 1,0 0,9 1,6 1,4 1,2 1,0 0,9 0,8 0,7 0,8 0,9 1,0 Displacement V g /V g max Inlet pressure p abs [bar] Table of values (theoretical values, without considering η mh and η v ; values rounded) ize 10 Displacement V g max cm 3 10,5 Max. speed 1 ) at V g max n o max rpm 3600 Max. perm. speed (speed limit) at increase in input pressure p abs or V g <V g max n o max zul rpm 4300 Max. volumetric flow at n o max q v max /min 37 at n E = 1450 min 1 /min 15 Max. power ( p = 250 bar) at n o max P o max kw 16 at n E = 1450 min 1 kw 6,5 Max. torque ( p = 250 bar) at V g max T max Nm 42 Moment of intertia about drive axis J kgm 2 0,0006 Fill capacity 0,2 Approx. weight (without oil fill) m kg 8 Permissible loading on drive shaft: max. perm. axial force F ax max N 400 max. perm. radial force F q max N 250 1 ) The values shown are valid provided there is an absolute pressure of 1 bar at suction inlet. y increasing the inlet pressure or reduction of the diplacement, the speed can be raised up to the maximum speed limit (see diagram). Calculation of size Volumetric flow V g n η v q v = 1000 [/min] Drive torque T = 1,59 V g p [Nm] 100 η mh Drive power 2π T n P = T n = q v p = [kw] 60000 9549 600 η t Direction of F q force± Fax /2 /2 V g = geometr. displacement [cm 3 ] per revolution p = pressure differential [bar] n = speed [rpm] η v = volumetric efficiency η mh = mech.-hydr. efficiency η t = overall efficiency (η t = η v η mh )

Variable displacement pump A10VO, eries 52 Installation Notes Installation position is optional. The pump housing must be filled with fluid during commissioning and remain full when operating. In order to achieve the lowest noise value, all connections (suction, pressure, case drain ports) must be linked by flexible couplings to tank. Avoid placing a check valve in the case drain line. This may, however, be permissible in individual cases, after consultation with us. 1. Vertical installation (shaft end upwards) The following installation conditions must be taken into account: 1.1. Installation inside a tank efore installation fill pump housing, keeping it in a horizontal position. a) If the minimum fluid level is equal to or above the pump mounting surface leave ports "", " 1 " and "" open (see Fig.1). b) If the minimum fluid level is below the pump mounting surface pipe port " 1 ", and possibly "" according to Fig. 2. Close port "" with respect to conditions in 1.2.1. 1 Fluid Fig. 1 1.2. Installation outside a tank efore installing the pump, fill the pump with housing in the horizontal position. For mounting above a tank see fig. 2. imiting conditions: 1.2.1. Minimum pump inlet pressure p in min = 0.8 bar both static and dynamic conditions. Note: Avoid mounting above a tank wherever possible in order to achieve a low noise level. The permissible suction height h is based on the overall pressure loss, but may not be greater than h max = 800 mm (immersion depth h d min = 0 mm). 2. Horizontal installation The pump must be installed, so that "" or " 1 " is at the top. 2.1. Installation inside a tank a) If the minimum fluid level is equal to or above the top of the pump, ports "", " 1 " and "" should remain open (see fig. 3). b) If the minimum fluid level is below the top of the pump, pipe ports "", " 1 " and possibly "" as fig. 4. The conditions correspond to item 1.2.1. 1 1 Fluid Fluid p In min 2.2. Installation outside a tank Fill the pump housing before commissioning. Pipe ports "" and the higher port "" or " 1 ". a) When mounting above the tank, see fig. 4. Conditions correspond to 1.2.1. p In min h max Fig. 3 1 Fig. 4 Fluid h h t min max Fig. 2 b) Mounting below the tank Pipe ports "" and "" according to fig.5. Fluid p In min Overall pressure loss p total = p 1 + p 2 + p 3 (1 p in. min ) = 0.2 bar p 1 : Pressure loss in pipe due to accelerating column of fluid ρ l dv p 1 = 10 5 (bar) dt ρ = density (kg/m 3 ) l = pipe lenght (m) dv/dt = change in rate of fluid velocity (m/s 2 ) p 2 : Pressure loss due to static head p 2 = h ρ g 10 5 (bar) h = head (m) ρ = density (kg/m 3 ) g = gravity. = 9.81 m/s 2 p 3 : ine losses (elbows etc.) 1 Fig. 5

86-0,1 53,5 56 ø11 Variable displacement pump A10VO, eries 52 Prior to finalizing your design, please request certified installation drawing. All rights reserved subject to revision. Dimensions size 10 Version A10VO 10 DR /52 R- KC64N00 U 40 107 haft end "K" Flange Flansch 82-2 82-2 AE J744 Okt 83 11 73 56 ø82,55 h8 ø19,05-0,02 2,5 28,6 Y 21,1 +0,05 4,76 +0,025 9 45 o 9/16-18UNF-2 33 1 8 6,4 41 24 9/16-18UNF-2 148 164 106,4 134 shown is clockwise rotation shown is counter-clockwise rotation 107 107 1 1/16-12UNF-2 tief deep 28,6 28,6 1 1/16-12UNF-2 tief deep 1 1/16-12UNF-2 deep tief 28,6 28,6 1 1/16-12UNF-2 tief deep haft end "" 19-4 (AE A-) 16/32DP; 11 T haft end "U" 16-4 (AE A) 16/32DP;9T ø 3/4" 1/4- UNC-2 14 22 30 38 Ports Pressure port 1 1/16-12UNF-2 Inlet port 1 1/16-12UNF-2 / 1 Case drain 9/16-18UNF-2

- 0,1 53,5 56 ø11 102 Variable displacement pump A10VO, eries 52 Prior to finalizing your design, please request certified installation drawing. All rights reserved subject to revision. Dimensions size 10 Version A10VO 10 DRG /52 R- PKC64N00 DFR1 U haft end "K" 40 105 Flansch Flange 82-2 AE J744 Okt 83 11 73 56 ø82,55 h8 ø19,05-0,02 2,5 28,6 33 8 24 1 9/16-18UNF-2 Y 21,1 +0,05 4,76 +0,025 9 106,4 134 45 o 9/16-18UNF-2 6,4 41 148 179 shown is clockwise rotation 105 shown is counter-clockwise rotation 105 105 11 1/16-12UNF-2 deep tief 28,6 28,6 1 1/16-12UNF-2 deep tief 1 1/16-12UNF-2 deep tief 28,6 28,6 1 1/16-12UNF-2 deep tief haft end "" 19-4 (AE A-) 16/32DP; 11 T haft end "U" 16-4 (AE A) 16/32DP;9T ø 3/4" 1/4- UNC-2 14 22 30 38 Ports Pressure port 1 1/16-12UNF-2 Inlet port 1 1/16-12UNF-2 / 1 Case drain 9/16-18UNF-2 Pilot port 7/16-UNF-2

53,5 58,5 ø11 86 Variable displacement pump A10VO, eries 52 Prior to finalizing your design, please request certified installation drawing. All rights reserved subject to revision. Dimensions size 10 Version A10VO 10 DR /52 R- PA14N00 40 107 IO IO 3019/2 3019/2 2 och-flansch 2-bolt-flange 11 73 56 ø80 h8 ø18 j6 2 25 Y,5-0,1 6 h9 9 45 o M16x1,5 28 1 8 7 36 24 M16x1,5 148 164 109 134 shown is clockwise rotation shown is counter-clockwise rotation 107 107 deep tief 28,6 28,6 deep tief tief deep 28,6 28,6 deep tief Ports Pressure port Inlet port / 1 Case drain M16x1,5

Variable displacement pump A10VO, eries 52 Prior to finalizing your design, please request certified installation drawing. All rights reserved subject to revision. Dimensions size 10 Version A10VO 10 DRG /52 R- PA14N00 DFR 73 132 M14x1,5 40 105 M16x1,5 IO IO 3019/2 3019/2 2 och-flansch 2-bolt-flange 11 117 56 44,9 o ø80h8 ø18 j6 2 25 28 1 109,7 Y,5-0,1 6h9 9 45 o ø11 53,5 58,5 8 7 36 24 M16x1,5 148 179 134 109 shown is clockwise rotation shown is counter-clockwise rotation deep tief 28,6 28,6 tief deep deep tief 28,6 28,6 deep tief Ports Pressure port Inlet port / 1 Case drain M16x1,5 Pilot port M14x1,5

Variable displacement pump A10VO, eries 52 DR Pressure control The pressure control serves to maintain a constant pressure in the hydraulic system, within the control range of the pump. The pump therefore supplies only the amount of hydraulic fluid required by the actuators. Pressure may be steplessly set at the pilot valve. Dimensions see page 6 and 8. tatic characteristic (at n 1 = 1500 rpm; t oil = 50 C) Hysteresis and pressure increase p max 4 bar q v max Flow q v etting range q v min 250 Operating pressure p (bar)

Variable displacement pump A10VO, eries 52 DRG Operating pressure Function and design as for DR. A pressure relief valve may be externally piped to port for remote control purposes. It is not, however, included with the DRG control. The differential pressure at the pilot valve is set as standard to bar and this results in a pilot flow of 1.5 /min. If another setting is required (in the range 10 22 bar), please state this in clear text. Not included in supply We recommend that one of the following is used as the separate pressure relief valve: DDH 6 (hydraulic) to RE 25402, DETR-O 437 with 0.8 mm dia. nozzle in P (electrical) to RE 29166. The length of piping must not exceed 2 m. tatic characteristic (at n 1 = 1500 rpm; t oil = 50 C) Hysteresis and pressure increase p max 4 bar Flow q v etting range 250 Operating pressure p [bar] Dimensions see page 7 and 9.

Variable displacement pump A10VO, eries 52 DFR1 Pressure/flow control n addition to the pressure control function, the pump flow may be varied by means of a differential pressure at the actuator (e.g. an orifice, not included in supply). The pump flow is equal to the actual required flow by the actuator. The DFR1-valve has no connection between and tank. Dimensions see page 7 and 9. Not included in supply tatic characteristic (at n 1 = 1500 rpm; t oil = 50 C) Q max q v max q v Flow q v etting range Q q min v min Operating pressure p (bar) 250 1