Chilled Water Fan Coil Unit Model:HFCF02~HFCF irflow Range:200~2400m /h HFCF HFXF VFCF
Features and Benefits The Best Choice for Comfort- The Best Results - Quiet Comfort Low noise permanent split capacitor motor. Metal fan wheel both statically and dynamically balanced. Threaded connection, match up duct collars and keyholes for hangers shorten installation time. Quick delivery helps meet tight installation schedules. - Latest Perfection Cleaner, quieter and more effi cient fi n design. The Best System - Design for comfort applications at home, offi ce and shop. HFCF is easily installed in a false ceiling or closet, HFCF is the ideal solution for new or replacement applications. The Best Fit - ine sizes to meet capacity requirements - One unit provides total comfort requirements: both cooling and heating - Low height of just 20mm on all sizes means no diffi culty in fi tting tight ceiling applications Filter (Option) Fan Flexibility - Easy to change water hand connections on the fi eld. Reliability Trane s history of innovation and technology leadership led to quality products making Trane a leader in the air conditioning markets worldwide. Trane s commitment to customer s needs for quality, effi ciency and reliability is evident from the largest chiller to smallest fan coil.trane s commitment to customer s needs for quality, effi ciency and reliability is evident from the largest chiller to smallest fan coil. Motor Plenum (Option) Coil head support Junction box Electric heater (Option) Drain pan Drain pan purge ir vent Coil Coil head support HFCF ccessories LCD Thermostat (except for DCBL) Z5/520 (for Trane ICS) Zone Sensor (for Trane ICS) TDG/Control Options Water Control Valve 2
HFCF Model omenclatures H F 2 C F 4 0 5 L 7 8 9 5 7 8 Digit : Digit 2: Digit : Digit 4: Digit 5, : Digit 7: Digit 8: Digit 9: Digit : Digit : Digit : H = Horizontal F = Fan Coil Unit type C = Concealed F = Design Sequence Size / ominal irfl ow 02 = 200 CFM 0 = 00 CFM 04 = 400 CFM 05 = 500 CFM 0 = 00 CFM 08 = 800 CFM = 00 CFM = 00 CFM = 00 CFM Connection Side L = Left Connection R = Right Connection Coil Rows 2 = 2 Rows Cooling = Rows Cooling 4 = 4 Rows Cooling = 2 Rows Cooling, Row Heating B = Rows Cooling, Row Heating Electric Heater (Size) = one = 0.5 kw Heater (02) B =.0 kw Heater (0) C =.4 kw Heater (04) D =. kw Heater (05) E =.8 kw Heater (0) F = 2.8 kw Heater (08) G =.2 kw Heater () H =. kw Heater () J = 4. kw Heater () Motor Type = ormal H = High Static = DCBL ormal (w/ LCD Thermostat) B = DCBL High Static (w/ LCD Thermostat) C = Hermetic Motor ormal Type D = Hermetic Motor High Static Type Voltage/Hz/Phase = 220/50/ 2 = 220~240/0/ = 5/0/ Factory Mounted Control / Valve Package = one = 2-pipe, with 2-way Valve B = 2-pipe, with -way Valve C = 4-pipe, with 2-way Valves D = 2-pipe, with 2-way Valve & LCD Thermostat E = 2-pipe, with 2-way Valve & LCD Thermostat (Confi gured with VWV System only) F = 2-pipe, with -way Valve & LCD Thermostat Digit : Digit : Digit 5: G = 4-pipe, with 2-way Valves & LCD Thermostat H = 2-pipe, with 2-way Valve & Z5 w/ Zone Sensor J = 2-pipe, with -way Valve & Z5 w/ Zone Sensor K = 4-pipe, with 2-way Valves & Z5 w/ Zone Sensor L = 2-pipe, with 2-way Valve & Z520 w/ Zone Sensor M = 2-pipe, with -way Valve & Z520 w/ Zone Sensor P = 4-pipe, with 2-way Valves & Z520 w/ Zone Sensor Q = 2-pipe, with 2-way Floating Valve & Z520 w/ Zone Sensor R = 2-pipe, with -way Floating Valve & Z520 w/ Zone Sensor S = 4-pipe, with 2-way Floating Valves & Z520 w/ Zone Sensor Terminal Box = Standard Wiring w/ Terminal Box B = Electric Heater Wiring w/ Terminal Box C = DCBL Wiring w/ Terminal Box D = Z Wiring w/ Terminal Box E = VWV w/ Terminal Box Return Plenum / Filter = one = with Rear Plenum Only B = with Rear Plenum/ mm ylon Filter C = with Rear Plenum/ 20mm luminum Filter D = with Bottom Return Plenum Only E = with Bottom Return Plenum/ mm ylon Filter F = with Bottom Return Plenum/ 20mm luminum Filter Drain Pan = STD. Galvanized Steel w/ 7mm PE Insulation B = STD. Galvanized Steel w/ 7mm PE Insulation & Extended 200mm C = STD. Galvanized Steel w/ 7mm PE Insulation & Extended mm D = Stainless Steel w/ 7mm PE Insulation E = Stainless Steel w/ 7mm PE Insulation & Extended 200mm F = Stainless Steel w/ 7mm PE Insulation & Extended mm G = STD. Galvanized Steel w/ mm on-fl ammable Close Cell Insulation H = STD. Galvanized Steel w/ mm on-fl ammable Close Cell Insulation & Extended 200mm J = STD. Galvanized Steel w/ mm on-fl ammable Close Cell Insulation & Extended mm K = Stainless Steel w/ mm on-fl ammable Close Cell Insulation Digit : Digit 7: Digit 8: L = Stainless Steel w/ mm on-fl ammable Close Cell Insulation & Extended 200mm M = Stainless Steel w/ mm on-fl ammable Close Cell Insulation & Extended mm = STD. Galvanized Steel w/ mm on-fl ammable Close Cell Insulation P = STD. Galvanized Steel w/ mm on-fl ammable Close Cell Insulation & Extended 200mm Q = STD. Galvanized Steel w/ mm on-fl ammable Close Cell Insulation & Extended mm R = Stainless Steel w/ mm on-fl ammable Close Cell Insulation S = Stainless Steel w/ mm on-fl ammable Close Cell Insulation & Extended 200mm T = Stainless Steel w/ mm on-fl ammable Close Cell Insulation & Extended mm U = STD. Galvanized Steel w/ 25mm on-fl ammable Close Cell Insulation V = STD. Galvanized Steel w/ 25mm on-fl ammable Close Cell Insulation & Extended 200mm W = STD. Galvanized Steel w/ 25mm on-fl ammable Close Cell Insulation & Extended mm X = Stainless Steel w/ 25mm on-fl ammable Close Cell Insulation Y = Stainless Steel w/ 25mm on-fl ammable Close Cell Insulation & Extended 200mm Z = Stainless Steel w/ 25mm on-fl ammable Close Cell Insulation & Extended mm Trane Digital Grille(TDG) = one = with Remote Controller Only B = with TDG LCD Thermostat Only C = with TDG LCD Thermostat & Remote Controller D = with Remote Controller & UV Light E = with TDG LCD Thermostat & UV Light F = with TDG LCD Thermostat, Remote Controller & UV Light Future Use = one Region = PR B = MIR C = LR
HFXF Model omenclatures H F 2 X F 4 0 5 L 7 8 9 B 5 7 8 Digit : H = Horizontal Digit 2: F = Fan Coil Unit type Digit : X = Exposed Digit 4: F = Design Sequence Digit 5, : Size / ominal irfl ow 02 = 200 CFM 0 = 00 CFM 04 = 400 CFM 05 = 500 CFM 0 = 00 CFM 08 = 800 CFM = 00 CFM = 00 CFM = 00 CFM Digit 7: Connection Side L = Left Connection R = Right Connection Digit 8: Coil Rows 2 = 2 Rows Cooling = Rows Cooling 4 = 4 Rows Cooling Digit 9: Electric Heater (Size) = one = 0.5 kw Heater (02) B =.0 kw Heater (0) C =.4 kw Heater (04) D =. kw Heater (05) E =.8 kw Heater (0) F = 2.8 kw Heater (08) G =.2 kw Heater () H =. kw Heater () J = 4. kw Heater () Digit : Motor Type = ormal C = Hermetic Motor ormal Type Digit : Voltage/Hz/Phase = 220/50/ 2 = 220~240/0/ = 5/0/ Digit : Factory Mounted Control / Valve Package = one Digit : Terminal Box = Standard Wiring w/ Terminal Box B = Electric Heater Wiring w/ Terminal Box Digit : Return Plenum / Filter = Standard with Return Plenum without fi lter B = Standard with Return Plenum/ mm ylon Filter C = Standard with Return Plenum/ 20mm luminum fi lter Digit 5: Drain Pan = STD. Galvanized Steel w/ 7mm PE Insulation D = Stainless Steel w/ 7mm PE Insulation G = STD. Galvanized Steel w/ mm on-fl ammable Close Cell Insulation K = Stainless Steel w/ mm on-fl ammable Close Cell Insulation Digit : Trane Digital Grille(TDG) = one Digit 7: Future Use = one Digit 8: Region = PR B = MIR C = LR 4
VFCF Model omenclatures V F 2 C F 4 0 5 L 7 8 9 B 5 7 8 Digit : Digit 2: Digit : Digit 4: Digit 5, : Digit 7: Digit 8: Digit 9: Digit : V = Vertical F = Fan Coil Unit type C = Concealed F = Design Sequence Size / ominal irfl ow 02 = 200 CFM 0 = 00 CFM 04 = 400 CFM 05 = 500 CFM 0 = 00 CFM 08 = 800 CFM = 00 CFM = 00 CFM = 00 CFM Connection Side L = Left Connection R = Right Connection Coil Rows = Rows Cooling Electric Heater (Size) = one = 0.5 kw Heater (02) B =.0 kw Heater (0) C =.4 kw Heater (04) D =. kw Heater (05) E =.8 kw Heater (0) F = 2.8 kw Heater (08) G =.2 kw Heater () H =. kw Heater () J = 4. kw Heater () Motor Type = ormal Digit : Digit : Digit : Digit : Digit 5: Digit : Digit 7: Digit 8: H = High Static C = Hermetic Motor ormal Type D = Hermetic Motor High Static Type Voltage/Hz/Phase = 220/50/ 2 = 220~240/0/ = 5/0/ Factory Mounted Control / ValvePackage = one Terminal Box = Standard Wiring w/ Terminal Box B = Electric Heater Wiring w/ Terminal Box Return Plenum / Filter B = with mm ylon Filter Drain Pan = STD. Galvanized Steel w/ 7mm PE Insulation D = Stainless Steel w/ 7mm PE Insulation G = STD. Galvanized Steel w/ mm on-fl ammable Close Cell Insulation K = Stainless Steel w/ mm on-fl ammable Close Cell Insulation Trane Digital Grille(TDG) = one Future Use = one Region = PR B = MIR C = LR 5
Performance Data Cooling Capacity (Example) Cooling Capacity : kw EWT : 7 Cooling Rows : SH: Sensible Cooling Capacity, kw ET : 27 / 50% LWT : Motor Frequency: 50Hz/ 0Hz WPD: Water Pressure Drop, kpa ESP : /50 Pa(ormal / Hi-Static) ESP : /50 Pa(ormal / Hi-Static) TH : Total Cooling Capacity, kw WFR: Water Flow Rate, L/S Model 02 0 04 05 0 08 Speed ominal irflow DCBL ominal Cooling Heating irflow Cap. Cap. Power DCBL Power 220V/50Hz 220V/50Hz oise DCBL oise Water flow WPD Cooling Cap. Heating Cap. Power DCBL Power 220V/50Hz 220V/50Hz oise DCBL oise m/h m/h kw kw w w db() db() l/s l/s kw kw w w db() db() l/s l/s Super Hight - 80 2.45.57-7.2-5 2.40.50-8. - 40 High 40 40 2..27 2.2 5 4 2.04.7 44.2 4 9 Medium 20 20. 2. 8 9.2 27 25 0.8.59 2.57 4 25.4 8 5 Low 90 90.2 2.0 5 8.4 2 2.8 2.00 29 5 28 2 Super Low - 0..7-8.4-2..72 -. - 25 Super Hight - 580 4.02 5.5-8.2-2.98 5.48-42. - 4 High 5 5.4 5.0 29 5.2 2. 5.9 5 9.2 42 40 Medium 80 80 2.7.90 20.2 2 2 0.72 2.58 4.04 9 29.4 5 Low 20 20.98 2.95 7 9.4 2 20.99.07 7 2 24 Super Low - 20.9 2.58-9.4-20.89 2.5 -. - 2 Super Hight - 780 4.9 7.09-7.2-7 4.77.88-55. - 44 High 80 80 4..27 4 5.5 7.59 5.5 4 50 45 4 Medium 490 490.0 4.95 2 8.4 29 27 0.209 9 2.87 4.7 48 28 8 5 Low 40 40 2.5.7 27.9 2 2 2.22.2 40 7 27 25 Super Low - 2.4.9 -.8-20 2..29 -.5-24 Super Hight - 970. 8.72-49. - 4 5.92 8.4-2.5-45 High 850 850 5.0 7.78 7 4. 42 40 4.94 7.5 85 59 4 44 Medium 70 70 4..54 0 25.2 7 4 0.25 27 4.20.4 8 7.5 40 7 Low 40 40.9 4.7 25 5.. 4.59 2 22 29 Super Low - 90.07 4.8 -.4-0 2.98 4.0 -.5-28 Super Hight - 70 7.0.8-5.7-4.85 9.87-8 - 45 High 20 20 5.99 9.02 77 0 4 42 5.4 8.85 92 47 44 Medium 7 7 4.79 7. 59 27 0.299 8 4.5.98 70 4 42 8 Low 480 480. 5. 48 7.5 2 24.9 5.04 57 22 4 Super Low - 90.8 4.28 -.2-24.09 4.5 -.5-0 Super Hight - 520 8..89-78.7-45 8.9.4 -.8-48 High 0 0 7..85 7 75.8 45 44 7.28.94 5 2.8 50 47 Medium 20 20. 9.95 0 48.8 9 0.8 22..09 4 7.2 45 4 Low 7 7 4.9 7.59 85 0.4 2 29 4.7 7.4 5 47. 8 5 Super Low - 580.89. - 2. - 28.8.02-2. - 4 Super Hight - 9.8.9-94.2-44. 5.8-9.8-50 High 700 700 9.9 5.04 2 82.8 47 44 9.7 5.9 7 7.8 5 49 Medium 0 0 7.7.48 5.5 8 5 0.459 28 7.87. 84.7 44 4 Low 850 850 5.79 9. 87 2.2 27 24 5.9 9.42 8 49.8 4 2 Super Low - 70 5.5 7.7-22.5-24 5.24 7. - 2.4 - Super Hight - 220.7 8.9 -.8-48.5 8.55-84.2-52 High 2040 2040.75 7.52 7 0.9 50 48.2 8.02 2.2 54 5 Medium 70 70 9.4 5.4 0 84.8 44 4 0.59 8 9.88 5.8 7 8.5 50 4 Low 50 50 7.42.74 52. 5 2 7.75.08 72. 4 8 Super Low - 780 5.97 8.9-2. - 5.85 8.22 -.8-7 Super Hight - 250. 2.22-5.8-50.92 20.58-222 - 55 High 280 280.4 9.89 95 50 52 50.27 20.52 28 202 5 54 Medium 790 790.8 7.0 70 97 4 4 0.25 49.8 7.85 257.4 49 4 Low 0 0 8.94.7 8 8.4 9 8.84.5 27 8.9 8 Super Low - 780.7 8.49-2.2-5 5.98 8.24-40 - 5 Water flow WPD 0. 0. 0.8 5 0.25 2 0.28 7 0.7 2 0.47 0.55 8 0.2 49 Spec./ Options HFCF Rows ESP 02 0 04 05 0 08 Input Power For 20V/ 0Hz W ormal static 28 45 59 82 7 242 2 5V/ 0Hz W ormal static 28 4 52 0 78 99 28 29 20V/ 0Hz W High static 55 77 97 79 242 28 25 5V/ 0Hz W High static 54 87 9 7 75 5 29 7 *Heater Capacity Type (kw) Hot water Row kw 2+ Pa. 2.4..82 4.49 5.49.7 7.84 9.7 EWT= 0 ; LWT=50 ; ET=2 kw 2+ Pa. 2.4..9 4. 5.54.7 7.85 8.98 kw 2+ 50Pa.2 2.5.09.8 4.24 5.4.7 7.9 9.0 kw 2+ 50Pa.45 2.44.07. 4. 5.48.75 7.9 9.20 kw + Pa.92..7 4. 5.54.74 8.8 9.80.4 kw + Pa.59 2.7.04.8 4.27 5.40.5 7. 8.7 kw + 50Pa.87.04.75 4.70 5.8.5 8. 9.97.7 kw + 50Pa.4 2.8 2.99.57 4.0 5.5.58 7.50 8.98 *Electric Sheathed Element PTC electric heater W 0.5.0.4..8 2.8.2. 4. *Plenum / Filters Return air plenum with fi lters PP ylon or aluminum
Dimensional Data and Weight HFCF Standard Unit HFCF Bottom Return Plenum and Filter Centrifugal Fan Motor Four Hanger Holes See View Hanger Holes(number.) See View Junction Box Return Plenum Centrifugal Fan Motor Filters D 88 2 Drain connection /4" MPT Control Box 2 4 B C 29 2 ir Outlet 5 7 24 487 44 92 20 4 B C 29 2 Header of drain water (/4 MPT) Outlet 5 Outlet 522 499 24 7 22 Rear return intake 98 20 24 Coil Drain Pan Water Outlet /4"FPT 270 Water Inlet /4" FPT Coil Drain Pan Outlet water Collar /4-inch female pipe thread(fpt) 270 Inlet water Collar /4-inch female pipe thread(fpt) HFCF Rear Return Plenum and Filter Return Plenum Six Hanger Holes See View Centrifugal Fan Motor Filter D View 522 499 2 88 8 Junction Box Drain connection /4" MPT 4 B C 29 24 22 Rear Return Plenum Box 2 ir Outlet 5 7 98 20 24 Coil Drain Pan 270 Water Outlet /4"FPT Water Inlet /4" FPT ote:.dimension in mm. 2.bove shown with right hard coil connection.wiring connection is located at the same side as coil and drain connections. 4.Wiring and junction box will be supplied by Trane. Dimension (mm) Motor Qty. Fan Qty. et Weight (kg) wihout Plenum Box and Filter et Weight (kg) wihout Plenum Box and Filter Unit Model ormal Static High Static ormal Static High Static B C D 2 Row Row 4 Row 2 Row Row 4 Row 2 Row Row 4 Row 2 Row Row 4 Row HFCF02 458 485 48 547 5 5 7 7 8 HFCF0 9 720 88 782 2 8 20 7 9 2 20 22 24 2 24 25 HFCF04 79 820 98 882 2 7 9 2 8 20 22 2 2 25 22 25 2 HFCF05 9 940 02 2 9 2 2 20 22 24 24 2 28 24 28 28 HFCF0 9 990 5 52 2 20 22 24 2 2 25 25 27 29 25 29 29 HFCF08 4 70 2 28 0 2 29 4 8 5 8 9 HFCF 9 520 8 582 2 4 0 2 5 8 7 40 4 9 4 45 HFCF 90 85 752 2 4 5 8 4 9 42 4 4 49 44 49 50 HFCF 79 820 98 882 2 4 7 40 4 8 4 44 45 48 5 4 5 52 7
Dimensional Data and Weight HFXF 55 C 9 VIEW 88 8 2 (545) 5 B 7 Hanger Holes(number. ) see View Control Box 545 55 4 2 2 20 255 9 7 255 55 Outlet Outlet water Collar /4-inch female pipe thread Inlet water Collar /4-inch female pipe thread ote:.dimension in mm. 2.bove shown with right hard coil connection.wiring connection is located at the same side as coil and drain connections. 4.Wiring and junction box will be supplied by Trane. Dimension (mm) Motor Qty. Fan Qty. et Weight (kg) Unit Model 2 Row Row 4 Row B C kg kg kg HFXF02 87 485 547 25 25 27 HFXF0 720 782 2 5 HFXF04 02 820 882 2 2 4 HFXF05 2 940 02 2 8 40 HFXF0 72 990 52 2 8 40 42 HFXF08 52 70 2 49 5 5 HFXF 902 520 582 2 4 5 5 59 HFXF 2072 90 752 2 4 4 7 HFXF 2202 820 882 2 4 9 8
Dimensional Data and Weight VFCF Coil 87 22 45 L Outlet 94 0 7 Drain Pan 20 Outlet water Collar /4-inch female pipe thread(fpt) 8 Inlet water Collar /4-inch female pipe thread(fpt) 247 Drain Hose Centrifugal Fan Motor Inlet djusting screw Control Box ote:.dimension in mm. 2.bove shown with right hard coil connection.wiring connection is located at the same side as coil and drain connections. 4.Wiring and junction box will be supplied by Trane. Dimension (mm) Motor Qty. Fan Qty. et Weight (kg) Unit Model Row L kg VFCF02 87 485 7 VFCF0 720 2 2 VFCF04 02 820 2 25 VFCF05 2 940 2 28 VFCF0 72 990 2 29 VFCF08 52 70 2 7 VFCF 902 520 2 4 42 VFCF 2072 90 2 4 47 VFCF 2202 820 2 4 5 9
Sound Pressure Data/ Wiring Diagram/ Coil Connection Sound Pressure Data Piping Connection Motor Type ormal Hi-Static Unit Octave Band (db) & Center Frequency (Hz) Octave Band (db) & Center Frequency (Hz) Speed Model 5 250 500 00 2000 4000 8000 5 250 500 00 2000 4000 8000 02 0 04 05 0 08 High 20 5 25 27 29 7 9 24 28 7 7 25 Med 20 9 2 2 9 9 9 22 2 4 2 Low 9 5 9 2 9 9 5 7 2 24 22 9 High 2 28 28 24 24 28 5 8 7 27 Med 8 9 8 9 22 29 29 7 9 Low 4 5 22 2 8 9 High 7 25 2 8 9 5 2 8 4 9 28 5 Med 7 8 25 25 2 9 7 2 25 2 4 9 Low 7 5 9 9 8 2 24 7 9 High 8 9 4 5 7 7 25 29 9 42 4 9 Med 20 7 27 0 8 2 29 4 2 Low 29 24 28 2 27 24 2 20 27 28 22 9 High 7 9 2 9 8 27 7 4 9 4 42 20 Med 9 22 28 29 2 5 9 2 2 0 5 8 7 2 Low 7 22 22 9 9 2 0 2 High 9 2 2 7 9 4 8 2 4 45 4 8 25 Med 2 20 28 2 4 2 7 27 7 4 4 8 Low 9 8 25 27 28 25 2 25 2 4 2 22 High 8 22 9 42 42 9 7 2 4 47 4 8 2 Med 9 7 25 2 4 9 2 0 7 40 8 29 Low 8 5 24 2 9 9 22 29 0 2 High 9 2 7 42 45 45 5 2 9 4 47 50 49 4 28 Med 5 25 2 8 9 7 2 7 2 7 44 4 45 5 2 Low 9 24 0 2 5 24 29 5 7 5 2 High 28 4 45 47 47 8 25 22 8 4 49 52 5 44 Med 5 25 40 42 40 29 2 2 7 42 45 44 4 2 Low 22 27 4 0 8 20 2 27 4 0 9 20 88 24 7 48 5 48,4 0,0 284,0 5,0 2,0 48,0 2,, 4 Row 5 2 49 74,0,0 48,0 487 Cold water out Hot water out 2,9 5,07,0 88, 20,9 otes:bove performance determined with both ormal static motor and Hi-static motor operating at 0 Pa ESP (no ducting, ceiling enclosed or other sound attenuating materials used). 74 0 284 Hot water in Cold water in Wiring Diagram 2+ Row C C MOTOR MOTOR WHITE RED BLUE BLCK (eutral) Model 08,,, only (Hi) (Med) (Low) WHITE (eutral) RED (Hi) 2 BLUE (Me) BLCK (Low) 4 220V 50Hz P 20V 0Hz P 5V 0Hz P L L Hi Thermostat Med Low 20 88 7 24 48 5 5 2 49 487 Cold water out Hot water out uto Reset st Electric Heater uto Reset 2nd Electric Heater Fuse Fuse BLCK RED BLCK RED OPTIO 5 L 220V 50Hz P 20V 0Hz P 5V 0Hz P 74 0 284 Hot water in Cold water in otes:.model speed control Yellow and Red Wires = High Speed Yellow and Blue Wires = Medium Speed Yellow and Black Wires = Low Speed 2.Contactor or relay shall be installed by others for an electric heater option + Row
Product Specification General Fabricated with a rigid galvanized steel casing. The HFXF outside cabinet is with powder coating. The DIDW centrifugal fans have balanced, galvanized steel, and forward curved blades. The fan board and the top of coil casing were insulated with high-density nonfl ammable foam. The coil casing shall be provided with collars,with screw holes for supply air duct and plenum box connections. Fan & Motor Motors are of permanent split capacitor type for maximum effi ciency and minimum noise with permanently lubricated, sealed ball bearings. Fan motor shall be capable of providing at least fan speeds( LOW-MEDIUM-HIGH) and built-in with thermal cut-out to prevent overloading at any speed and duty of the fans. The motor capacitor is totally enclosed in a metal shield, and attached to the motor. The motor lead-out wires are enclosed in a fl exible metal conduit to provide protection against damage, and factory wired to a terminal block inside a factory installed junction box. n optional item of hermetic fan motor shall be identical performance as typical under rated of IP2 or equivalent. Optional DC motor is available for customer choice (except HFXF and VFCF). The motor shall be with CE and GB safety certifi ed. Coil The coil shall have 2, or 4 rows confi guration with seamless copper tubes mechanically bonded into blue aluminum fi ns and collars. The coil shall be designed with bottom accessible for ease of switching coil hands/ water connections at jobsite. Water inlet /outlet connections shall be with /4-inch female pipe thread (GBT900-2000). Header assembly shall be one-piece brass casting which accepts steel pipe directly. Coils are /8 inch OD copper tubes mechanically bonded into aluminum blue fi ns. The coil standard provide blue fi n. The blue coating is a vinyl-epoxy-based coating. manual air vent shall be fi tted with a drain tube to the drain pan to avoid any water drips when venting. water plug is located at the bottom of the coil header. Coil assembly shall be tested over 25kg/ cm2 (0 psi), no obvious leakage under working pressure at kg/cm2 (20 psi). water drain pan purge is located at the bottom of the coil header Interchangeable coil hand connections for HFCF(2//4 row) only. Drain Pan The drain pan shall be thermally insulated galvanized steel, pretreated with epoxy resin coating at an inner surface. For maximum security from leaks, drain pan shall be one-piece stamping with no seam or joint. The standard insulation material is 27kg/ m density PE foam. nd the thickness is 7mm. //25mm thickness non-fl ammable close cell insulation is available for option. The drain pan shall have galvanized steel male with /4-inch connection. The drain pan shall be removable and have a slight fall towards the drain connection. Fan Coil Options Heater Either hot water heating or positive temperature coeffi cient (PTC) electric heater is available as for heating option. One row heating coil for HFCF(2+ / +). Plenum & Filter The fi lter shall be selected with permanent, dry type, washable nylon or fl ameproof aluminum foil(except VFCF). Optional bottom return air plenum or rear return air plenum for HFCF. Stainless Steel Drain Pan The material shall have graded SUS 04 or equivalent. Factory-mounted Control valve Package for HFCF Factory mounted 2-way or -way control valve with fi tting to the coil, it shall be tested against the maximum working pressure of coil. Factory mounted and functional test done for Trane ICS fan coil controller. ll cables are wired to a terminal block inside a factory installed junction box. Trane Build Management System The Tracer Summit system is designed for monitoring and control air conditioning system, lighting and other controllable devices for building. Such Building Control Unit (BCU) manages all Unit Control Modules (UCM) for different zones management. Each UCM performs scan on couples of HFCF equips Z controller in specifi c zone and regularly report to the central system. DC Fan Motor for HFCF Energy saving/ high effi ciency, low electro magnetic noise. More accurate temperature control(±0.5 deg. C) and low running noise at auto mode Variable airfl ow (lowest at 0%) by brushless DC fan motor, achieve of comfortable room temperature. Fan motor comes with specifi c controller and backlight LCD thermostat, key card with standalone confi guration.
The Trane Fan Coil.....Invented by Trane...Perfected by Trane. Since 885, Trane has been at the technological forefront of air conditioning. The company's pioneering spirit, commitment to research and pursuit of quality have made it a world leader in the manufacture of water chillers. Over 70 years ago Trane produced the fi rst fan coil unit and in so doing created a product which is now built worldwide. The universal acceptance of this product has prompted Trane to focus the same engineering experience to the fan coil as given to the refrigeration products. www.trane.com Literature Order umber Date Supersedes UT-PRC0-E May 2009 June 2008 For more information, contact your local Trane offi ce or e-mail us at comfort@trane.com Trane has a policy of continuous product and data improvement and reserves the right to change design specifi cations without notice.