Installation manual ValkPitched - Insert

Similar documents
Installation manual ValkPitched - Clamp

Installation manual Pitched Roof Clamp System

Installation manual Solar Tracker

Solar mounting systems for flat roofs

Tracking and fixed solar mounting systems

HORIZONTAL INSTALLATION

PITCHED ROOF STRUCTURES

AA Solar and Sun Power Plus

Solar Mounting System

PV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY

00MK-MA0190-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Universal Light system with locking brackets, for sloped roof

UBBINK SOLAR IN-ROOF SYSTEM

RAIL FREE SOLAR ROOF MOUNT

ASSEMBLY INSTRUCTIONS Residential Roof solutions

39HQ Airovision Air Handling Units

ES-A Series Photovoltaic Panels

Assembly Instructions for the InteliTrack 3000 Rail Tracking System

Solar Mounting Catalogue

Washer, Electrical Equipment Bond WEEB


PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

How To Mount An Ecosa Series Solar Panel

INSTRUCTIONS: LocknCharge Laptop Carts

Washer, Electrical Equipment Bond. WEEB Patent Pending INSTALLATION INSTRUCTIONS. For Kinetic Solar K-Rack only

MGB Chrome Bumper Conversion

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

EZ-Steer Assisted Steering System

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Expanding a 40-Type Cabinet

Installation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab

BUILD A CARPORT. 2 - Planning the carport. 3 - Designing the carport

Installation Guide. -- Standing Seam 8 Corrugated Metal Roof Mounting System

RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN

Cable Drum Installation

Installation instruction do88 Intercooler for Volvo S40 / V50 / C30

Flat roof assembly system from Solarworld Design and installation

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Machine devices, jig devices

S OUNTING INSTRUCTION M M o u n t i n g k i t 2 &

INSTALLATION INSTRUCTIONS COMPETITION SERIES COILOVER SUSPENSION SYSTEM 03+ Scion xb

Phoenix Solar AG. Phoenix TectoSun 3 Installation instructions

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

EZ-48-3AB Weather Station Mounting Tripod and Mast

Installation Guide 2010 BMW S1000RR Full Exhaust System

Kiosk Group, Inc. ASSEMBLY INSTRUCTIONS FOR THE STANDALONE. EXQUISITE ipad KIOSK. For ipad Version Tablets.

Mounting Tripod Kit Installation Manual

Installation Instructions For Slider Casement Air Conditioners

Technical data sheet PVC Bi-fold doors

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

KEEP FOR FUTURE REFERENCE MRTALP VERTICAL LIFT BAR READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT

Post Mount Light Installation*

4BT A/C Bracket Directions

Step by Step instructions How to screw in wood and plastic

Owner s Manual Gantry Cranes

POD Visor Instructions

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

These Installation Instructions are valid for antennas in the following version:

Thanks for choosing Toroidal. This file is developed to assist you in assembling and aligning Toroidal Dish.

assembly instructions

OBTAINED FROM PHOTOVOLTAIC SYSTEMS SUPPORTED BY METALSISTEM STEEL STRUCTURES

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

Installation Instructions

TopSky DLG Installation Manual

Installation Instructions

Bathroom Installation Guide

WHAT S DIFFERENT. about TimberTech CableRail? Covered under warranty by ONE trusted manufacturer. Saves TIME and EFFORT

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

Freightliner AirLiner Suspension 32.05

QUANTIFYING SOLAR ENERGY

Operating Instructions Drill rig DRU160

VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy

Machine Screws, Dowel Pins and Hardware

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

WHAT S DIFFERENT ABOUT OUR CABLERAIL?

12U Adjustable 4 Post Open Frame Server Rack

Installation instruction CASAFLEX - Connecting piece DN 100

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250 Single Wheel 4WD Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

LockerLock Schließgehäuse LockerLock lock case Boîtier de fermeture LockerLock Scatola di ciusura LockerLock Caja de cierre LockerLock

Structural Holding System

Guidelines for Earthquake Bracing of Residential Water Heaters

TECHNICAL INFORMATION

SunnyMec 3000 The innovative bi-axial PV tracker Data Sheet

BUILD A TABLETOP LOOM

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Plumbing. The convenient, compact and clever solutions to your wrench and hand tool needs

Technical handbook Panel Anchoring System

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection

UNIVERSAL MOUNTING SET (UMS) FOR ARTOLINK FSO EQUIPMENT

TREX SELECT RAILING. Installation Instructions BUY TREX PARTS G * I ** H *

SINTEF Building and Infrastructure. Contents

AluGrid product sheet

K17.11 DOOR BOLTS K17 DOORS

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Front axle components, overview

Installation Instructions: (Part # SB76880) XRC Armor Front Fender Kit

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Façade panels for interior cladding on a wooden supporting structure

Transcription:

Van der Valk Solar Systems TRCKING ND FIXED SOLR MOUNTING SYSTEMS Installation manual ValkPitched - Insert Version 10

EN General user instructions Solar mounting systems Congratulations on buying a Van der Valk Solar Systems mounting system and on helping the environment by deciding to install solar panels. This document must be seen in addition to the installation manual and installation instructions. * The general user instructions describe general installation and safety instructions. * The installation manual shows you how to install the solar mounting system. * The installation instruction gives you specific measures of the engineered mounting system as a result of the 1-2-3 PV Planner. The instructions provided in these user instructions must be observed at all times. Read these instructions carefully and keep them in a safe place for future reference. lso follow the instructions stated in the manuals and instructions for the other system components that are a part of the overall PV system. ll current structural, safety and building regulations must be observed. Van der Valk Solar Systems B.V. will never be liable for any direct and/or indirect intangible or consequential loss ensuing from or connected to the failure to observe the instructions provided in these user instructions. Safety instructions for roofs Solar mounting systems installed on roofs will be exposed to wind and snow. The building in question will be subject to a greater load as a result of the PV system. design calculation must be used to establish whether or not the building in question will be able to withstand the extra load. Where necessary, modifications need to be made. The standards applied (if applicable for specific solar mounting system) EN 1990 Basis of structural design EN 1991-1-3 ctions on structures / Snow loads EN 1991-1-4 ctions on structures / Wind actions EN 1993-1-1 Design of steel structures / General rules for buildings EN 1993-1-3 Design of steel structures / Supplementary rules for cold formed members EN 1997 Geotechnical design EN 1998-1 Design of structures / General rules, seismic actions and rules for buildings EN 1999-1-1 Design of aluminium structures NEN 7250 Solar systems - Integration in roofs and facades - Building aspects (pending) BS EN 1991-1-4 British Standard pplication To calculate the needed strength, ballast and foundation of the solar mounting system, according the Eurocodes, the specific location details have to be determined, e.g. wind zone, snow zone and height of the building. These need to be entered in the 1-2-3 PV Planner. Foundations and strength of field systems are calculated with SolarTop. Type of solar panel The Van der Valk Solar Systems mounting systems are universal mounting systems for solar panels. lmost any solar panel with of without an aluminium frame, possibly with mounting holes, can be mounted. Types of roof Type of roof covering: bitumen, EPDM, PVC, concrete and other roof coverings. For ballast calculations the exact roof covering must be known. Before installing the solar mounting system, make sure that you carefully sweep the roof area. The ballast calculation for flat roofs only applies for roofs with a slight pitch of up to 5. bove t his roof pitch, the system needs to be attached to the roof securely. Ballast Flat roof systems can be attached to the roof or need to be supported by ballast, to make sure that the system is unable to move, lift or tip over. The components supplied do not fully include the ballast required, which will be a number of tiles with a certain measurement and weight. The number of tiles required per position, per type of solar panel, per roof area and per building height is calculated via the 1-2-3 PV Planner and can be seen in the installation instructions and foundation adivse. The number of tiles specified per position will be vital to ensure that the mounting system can be used safely. Position Restrictions also apply for the position of the system on a roof. The solar panels must be installed at a certain distance from the edge of the roof. Follow the scheme in the installation manual calculated by the 1-2-3 PV Planner. Guarantee The guarantee provided is subject to the guarantee conditions stated in the general terms and conditions stipulated by Van der Valk Solar Systems BV. Our terms and conditions can be found on our website: www.valksolarsystems.nl. The ValkBox 3 mounting system is a product that has been produced by: Van der Valk Solar Systems B.V., Registered with the chamber of commerce for Haaglanden under number 27355116. Internet: www.valksolarsystems.nl Issue date : March 2014 Version: General user instructions v1 EN

Van der Valk Solar Systems TRCKING ND FIXED SOLR MOUNTING SYSTEMS Please Note This manual is not project specific. This manual is not legally binding. No right may be derived from this installation manual. Use this manual in combination with the 1-2-3 PV Planner. Check Datasheet Cable management for cable suggestions. Table of contents General user instructions Page - Necessary tools Page 01 Mounting the Hangerbolts Page 02 Mounting the Smartline roofhooks Page 03 Mounting the Standard roofhooks Page 04 Mounting the Slimline roofhooks Page 05 Coupling the Side+ profile Page 06 Mounting the Insert Clamps Page 07 Mounting the Insert Clamps (Overview) Page 08 Mounting the Insert Clamps (Overview) Page 09 Mounting the Side+ profile Page 10 Mounting the Insert profile Page 11 Coupling the Insert profile Page 12 Mounting the End piece Page 13 Mounting the Solar panels Page 14 Mounting the Cable Clamps Page 15

Necessary Tools For ValkPitched - Insert Wrench 7,9,13,15 and 18 Socket 7,9 and 13 Torx bit T30 Cordless drill (for socket 7,9,13 and Torx bit T30) 01

M10 74.79.15 (M10x200) Mounting the hangerbolts Detail 74.79.17 (M10x250) Detail M12 74.79.20 (M12x250) 74.79.22 (M12x350) See page 3 Drill hole for Hangerbolts. M10 : Hole size 10 mm in corrugated sheet M12 : Hole size 12 mm in corrugated sheet Pre drill in wood. M10 : Hole size 7.0 mm M12 : Hole size 8.4 mm See page 4 See page 5 Distance between Hangerbolts. See Installation instructions of the 1-2-3 PV Planner. 02

Mounting the Smartline roofhooks 74.78.28 (horizontal profile) 74.78.29 (vertical profile) Detail L (L [mm]) 75.40.---- 77.38.40 Detail 73.90.03 7Nm See page 2 See page 4 Keep at least 3 mm clearance See page 5 Distance between Roofhooks. See Installation instructions of the 1-2-3 PV Planner. 03

74.78.42 (horizontal profile) 74.78.43 (vertical profile) 74.78.08 (horizontal profile) 74.78.09 (vertical profile) Mounting the Standard Roofhooks Detail Detail See page 2 See page 3 7Nm See page 5 Distance between Roofhooks. See Installation instructions 1-2-3 PV Planner. 04

Fixed 72.95.30 (horizontal) 72.95.31 (vertical) Mounting the Slimline roofhooks Detail djustable 72.95.40 (horizontal) 72.95.41 (vertical) Detail See page 2 See page 3 See page 4 Distance between Hanghooks. See Installation instructions of the 1-2-3 PV Planner. 05

Mounting the Side+ coupling Detail L (L [mm]) 70.16.----- 72.48.65 B The groove of the bolt corresponds with the orientation of the bolt head. Detail B 06

Mounting the clamps 72.40.51 2 1 07

72.40.51 Mounting the clamps large Option 1 Upper profile Clamping side down Insert assembly help 38 small Clamping side up Upper profile Clamping side down Clamping side up small Panel size - 119 Panel size - 87 Panel size - 131 large Option 2 Panel size - 163 Lower profile Clamping side up Lower profile Clamping side up Note: See page 9 when only using middle profiles. 08

72.40.51 Mounting the clamps When only using middle profiles Option 3 Clamping side down Insert assembly help 38 Clamping side up Clamping side up Clamping side down Panel size - 87 Panel size - 87 Panel size - 130 Option 4 Panel size - 130 Clamping side up Clamping side up 09

Min. 1mm Mounting Side+ profile 72.11.00 1 Detail Detail B The groove of the bolt corresponds with the orientation of the bolt head. 2 C Detail C Top view 3 When the bolt is tightened, the hangerbolt is forced into the aluminium profile. t least 1 mm thread above the clamp. M12 M10 10

Lower profile Upper profile L Upper profile (panel height in mm) (L [mm]) 70.01.---.----- large Mounting insert profile Detail L (panel height in mm) (L [mm]) 70.03.---.----- small 1 2 3 Lower profile L (panel height in mm) (L [mm]) 70.05.---.----- 11

Coupling insert profile 72.48.10 Detail 3 12Nm 2 1 12

Mounting end piece 72.48.20 option 1 12Nm option 2 12Nm 13

Mounting panels 1 2 14

73.20.01 Max. cable diameter 9 mm Mounting cable clamp Mounting cable clamp on panel. 73.20.03 Max. cable diameter 9 mm 73.20.05 Max. cable diameter 9 mm Mounting cable clamp on insert profile. Mounting cable clamp on Side+ profile. 15

Van der Valk Solar Systems Van der Valk Solar Systems is a specialist company that is fully focused on developing and producing mounting systems for use with solar panels. To this end we work in close collaboration with Van der Valk Systemen, our sister company. Van der Valk Systemen has been a well-known name in the field of moving systems and stationary components for the greenhouse horticultural sector and industry throughout the world since 1963. Van der Valk Systemen s high quality products have been individually developed from a scientific approach and produced with mathematical precision. They are made to be low-maintenance and to stand out thanks to their durability, reliability, functionality and ease of assembly. Both Van der Valk Systemen and Van der Valk Solar Systems only introduce innovative products to the market. Our shared business complex consists of 20,000 m 2 of offices and production facilities, in which modern machinery and the latest technologies facilitate development, manufacturing and testing that is fast, flexible and precise. Developer and producer of solar mounting systems for: Open Fields Pitched Roofs Flat Roofs Greenhouses Water Features