ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013



Similar documents
Select Radiators Installation Guide

SunMor SM-V30 Solar Water Heater Installation Manual

Technical catalogue panel radiators POLAND 2014

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Watts Pure Water Systems

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Operators manual Basic water heater

Mikrotherm. Manual radiator valves. To be precise.

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Your safety and the safety of others are very important.

How To Build A Brugman Compact Radiator

STABITHERM INSTALLATION & SERVICE BOOKLET

AMX300 DirectConnect Mixing Valve Kits

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

REGULATORS 175/153 Series

SIMPLAIR PIPING TOOL

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Slide 1. Slide 2. Slide 3 288,817,200,000. Thank you for attending the session on Hot Water Re-Circulation.

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

NAVIEN AMERICA INC FITCH AVENUE

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Hydraulic Control Solutions

Valve systems Base plates, according to standard ISO Brochure

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

FILLING AND PURGING THE SYSTEM

Electric Flow Boiler

Thermostatic valve Type AVTA

Series 510 Submersible Level Transmitters

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

SunMaxx Solar Filling Station Operating Instructions

Electric & Gas Water Heaters

1. Geo Vertical 2. Geo Horizontal

Laddomat Charging unit

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Automatic Bypass Control AVDO

1. RANGE OF APPLICATION 3. SAFETY INSTRUCTIONS 4 4. DESIGN 4

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

AIR LINE VALVES AND GAUGES

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Iron Air Charge 2510-SXT Installation & Start-Up Guide

Data sheet Thermostatic sensors type RA 2000

Technical catalogue convectors POLAND 2012

SHOWERS SHOWERS

123 Industrial Loop Road Paynesville, MN Phone:

Powers Controls TH 192 S Single Temperature Room Thermostat

Isotemp Basic, Slim/B & Slim Square

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual.

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

1. Taboe Sani 2. Taboe 3. Taboe Freestanding

Draft Specification PEX tubing. Section Radiant-Heating Hydronic Piping. (Roth Radiant Heating Systems)

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS

Industrial infrared heater IR For premises with large volumes and high ceilings

Description of functions

How To Buy A Designo Grille

VOYAGER 570G. 744A Sprayer Control

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

T-4000 Series Room Thermostat Adjusting Instructions*

Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8

Fan Convector Technical Specifications January 2006 Rev A

HS-901(A) BASIC STEAM HEATING SYSTEMS

CATHODIC PROTECTION SYSTEM DESIGN

HOSE, TUBE, AND PIPE CLAMPS

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

Water Pump Replacement

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Ice Maker. User Manual HI6LMK. Haier America New York, NY Haier America Trading, LLC.

Installation and maintenance instructions

Installation Instructions - For the following HEATER model numbers: 200, 300, 400, 500 Series Hydronic Heaters

HERZ-Thermal Actuators

ASME Packaged Indirect Fired Water Heater

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

INFRARED RADIANT HEATERS. air heaters

Hose Clamps & Fittings

FLEXCON EXPANSION VESSELS. Flamco FLEXCON Flexcon. Expansion vessels FLEXCON FLEXCON M. Flamco FLEXCON V-B.

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

Troubleshoot resources for homeowner

15430 SAFETY SHOWERS AND EYEWASHES

FLUSHOMETER - TANK SYSTEM

Transport & Automotive CATALOGUE. March Customer Service Phone: Fax: sales@tubefit.com.au.

INSTANT HOT WATER RECIRCULATING SYSTEM

AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Radiant Comfort Warmth by Design

Transcription:

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 0 QUALITY 0 YEAR GUARANTEE Exclusively distributed by:

Table of contents Panel radiators General / Guarantee Technical data and radiator dimensions Connections Output Tables Correction Factor Table 7 Thermostatic Valve Adjustment 8 Radiator Fittings 8 Series Piping 9 Monoflow Tee Piping 0 Manifold Piping General The Biasi radiators are produced from high-quality material and components. EXCELLENT HEAT OUTPUT Modern radiators have remarkably low water content to ensure fast heat-up and high output. The low water content combined with large convector plates radiate heat in a highly efficient way. HEATING SYSTEM Biasi radiators are designed for use on closed heating systems, where the free access of oxygen is prevented. A compact, well planned and constructed system saves energy and components making up the system. Draining the system requires more fresh water, which result in rust on the inside of the steel surface. Due to this it is not advisable to empty the heating system for the summer. The water temperature should be between 0 to 0 F and the ph value between 7 and 9. MOUNTING Current directives and generally accepted practices must be followed when the radiator is mounted. It is not recommended to remove the plastic cover until all the construction work is completed. The wall must always be checked before the brackets are mounted to ensure it can support the weight and use of the radiator. The Ecostyle radiators are supplied with clamp bracket for easy mounting. APPLICATION ENVIRONMENT Biasi radiators are intended for heating dry rooms. In case they are mounted in bathrooms, the mounting must always be on dry walls and not directly under a shower or similar fixture. PRESSURE RATING The working pressure of Biasi radiators is 87 psi. It must not be exceeded when planning the heating system. In heating systems of tall buildings one also has to remember the dynamic, additional pressure given by the pump, beside the normal hydrostatic pressure. All Biasi radiators are pressure tested during production. Guarantee Each Biasi radiator is guaranteed for 0 years from the date of installation against defects caused by faulty materials or manufacture. The defective product is replaced by a similiar or technically corresponding radiator. The guarantee does not cover damages that are due to faulty storage and handling at delivery or installation, nor damages that are due to faulty use of the radiator, such as inside and outside rust, use or corrosive substances, too high pressure or damage due to freezing. The guarantee does not cover incidental damages caused by the Biasi product, costs for change of product, production loss of the customer, In case of a guarantee claim the buyer must contact the seller and present of evidence of purchase of the product, for example, tion number of the radiator. The defective product must always be sent back to Biasi for inspection within one month from the day of complaint, if not otherwise agreed upon. - YEAR QUALITY 0 GUARANTEE

PANEL RADIATORS ECOSTYLE Ecostyle Technical data Material Cold rolled steelplate EN 00 Surface treatment Alcalically degreased Phosphated ps: Dipped in primer (cathaphoretic) Coated with polyester-epoxy resin powder Baked (about 00 F) Standard color White, RAL 90. Working pressure The surface treatment process follows the standard DIN 900. 87psi Connections x /" C ISO 900 and ISO 00 Heights Lengths Types Packaging,, 0, and inch Vary by height ( - 7 inches) Double Panel Clamp brackets included in the package. Thermostatic valve insert, air vent and installed blind plugs included. Radiator Dimensions

PANEL RADIATORS ECOSTYLE Connections The integrated valve system is welded onto the radiator during the manufacturing process and is All Biasi Ecostyle radiators are equipped with a built in valve insert suitable for thermostatic sensor heads (purchased separately). BOTTOM CONNECTION Thanks to the built in valve system, connection at the bottom is possible. Bottom right hand connection is standard, but the radiators are reversible so left hand connection is possible. SAME END CONNECTION Top-bottom same end connection requires external supply and return valves. The bottom connections are to be plugged. OPPOSITE ENDS CONNECTION Top-bottom opposite ends connection requires external supply and return valves. The bottom connections are to be plugged. Note! The radiator must be connected as above. Faulty connections might cause a heat output decrease.

PANEL RADIATORS ECOSTYLE Ecostyle Radiator Output Chart Radiator Model Height (in) Length (in) Output (BTU) Output (BTU) Weight (lbs) Water Content Equivalent Baseboard @ 80 F (ft) @ 80 F @ 0 F (gal) B-. ECO,70,0 0.7.0 B-. ECO,,8 0.. B-. ECO,,0 9 0.7.0 B-.0 ECO 0,,79 7 0.90 7. B-.8 ECO 8,9,09.08 9.0 B-. ECO,97,0.7 0. B-. ECO,88,8 8..0 B-. ECO,7,0 0 0.8.8 B-. ECO,,97 0 0.7.7 B-. ECO,7, 0 0.9 7. B-.0 ECO 0,,77 9.9 9. B-.8 ECO 8,0,9 9.. B-. ECO 7,87,8 9.. B-. ECO 8,7, 78.90. B-.7 ECO 7 9,78,899 88. 7. B-0. ECO,0,78 0.8. B-0. ECO,9,7 7 0.87.9 B-0. ECO,, 0. 9. B-0.0 ECO 0 0,,9.. B-0.8 ECO 8 7,8,7 7.7.7 B-0. ECO 9,7, 8.0.0 B-0. ECO 0,, 98.0 8. B-. ECO,07,8 0 0.9. B-. ECO,,7.0 8.0 B-. ECO,09,9 0.0 0. B-.0 ECO 0 7,87,8 7.7. B-.8 8 ECO 8 9,0,00 89.09.00 B-. ECO 0,, 0. 8. B-. ECO,8 7,7 8.80. B-.7 ECO 7, 8,..0 B-. ECO,0, 0.9 7. B-. ECO,,8 8.. B-. ECO 8,80, 90.90.9 B-.0 ECO 0 0,0,09.8 8. B-.8 ECO 8,7 7,9.8. Outputs based on supply temperatures shown, 0º F T and 8º F Room Temperature

PANEL RADIATORS ECOSTYLE 7 Radiator Output Correction Factors Water Temperature Room Temperature ( F) Supply ( F) Return ( F) 0 8 7 7 00 8.8..0...9. 00 80...8..0.. 00 7..9...7..09 00 70.0...8...07 90 7.8..0...09.0 90 70...8..0.0.0 90..9...07.0 0.99 90 0.0...08.0.0 0.97 80.8..0.0.0 0.99 0.9 80 0...08.0.00 0.9 0.9 80..09.0.0 0.97 0.9 0.89 80 0.0.07.0 0.98 0.9 0.9 0.87 70.09.0.0 0.9 0.9 0.89 0.8 70 0.0.0 0.98 0.9 0.90 0.87 0.8 70.0 0.99 0.9 0.9 0.87 0.8 0.80 70 0.0 0.97 0.9 0.88 0.8 0.8 0.77 0 0.99 0.9 0.9 0.8 0.8 0.79 0.7 0 0 0.9 0.9 0.88 0.8 0.80 0.77 0.7 0 0.9 0.89 0.8 0.8 0.78 0.7 0.70 0 0 0.9 0.87 0.8 0.78 0.7 0.7 0.7 0 0.89 0.8 0.8 0.77 0.7 0.9 0. 0 0 0.8 0.8 0.78 0.7 0.70 0.7 0. 0 0.8 0.80 0.7 0.7 0.8 0. 0.0 0 0 0.8 0.77 0.7 0.8 0. 0. 0.7 0 0.79 0.7 0.7 0.7 0. 0.0 0. 0 0 0.7 0.7 0.8 0. 0.0 0.7 0. 0 0.7 0.70 0. 0. 0.8 0. 0.0 0 0 0.7 0.7 0. 0.8 0. 0. 0.7 0 0.9 0. 0. 0.7 0. 0.0 0. 0 0 0. 0. 0.8 0. 0. 0.7 0. 0 0 0. 0.0 0. 0. 0.8 0. 0.0 0 00 0. 0.7 0. 0.8 0. 0. 0. 0 0 0.9 0. 0. 0.7 0. 0.0 0. 0 00 0. 0. 0.9 0. 0. 0.7 0. 0 9 0. 0.0 0. 0. 0.8 0. 0.9 0 90 0. 0.7 0. 0.8 0. 0. 0.

8 PANEL RADIATORS ECOSTYLE Ecostyle Thermostatic Valve Adjustment Each Ecostyle radiator is supplied with a adjustable valve body. Each valve body is fi ed with a factory installed manual adjustment cover (Fig. ). By turning the cover clockwise water flow to the radiator is reduced. By turning the cover counter clockwise water flow to the radiator is increased. If the cover is removed completely (Fig. ), the valve will be in the full open posi on. Each valve is also equipped with a flow limiter adjustment. It will control how much water is allowed through the radiator at the full open cover posi on. It is adjusted by turning the black plas c segmen of the valve. The adjustment is labeled with the numbers through. being the least amount of flow and being the maximum amount of flow. The indicator mark on the brass sec on of the valve indicates the se ng of the valve. Fig. shows examples of three different se ngs. A termosta c head can also be mounted to the valve body to allow automa c adjustment of the valve according to room temperature. To fit the thermosta d head, simply remove the adjustment cover completely exposing the valve body. Place the collar of the thermosta c head over the valve body (Fig ). Thread the collar of the thermosta c head onto the valve body un l ght (Fig. ). Set the termosta c head according to the manufacturers instruc ons for desired room temperature. Flow Se ng: Maximum flow allowed through radiator Fig. Fig. Fig. Flow Se ng: Half flow allowed through radiator Flow Se ng: Minimum flow allowed through radiator Radiator Connection Fittings Fig. Fig. DIVERTER VALVES RV-0 STAIGHT DIVERTING VALVE RV-0 ANGLED DIVERTING VALVE NOTES: ADJUSTABLE BY-PASS FROM 0-0 % ISOLATION VALVES RV-000 STAIGHT ISOLATING VALVE RV-00 ANGLED ISOLATION VALVE THERMOSTATIC CONTROL RV-00000 THERMOSTATIC CONTROL HEAD TOWEL BAR VALVES RV-8 ANGLED THERMOSTATIC VALVE RV-9 STRAIGHT THERMOSTATIC VALVE 7 RV- ANGLED SHUT OFF RV- STRAIGHT SHUT OFF PIPE CONNECTIONS - (SOLD PER PAIR) RV-80A /8 PEX COMPRESSION FITTING RV-8 / PEX COMPRESSION FITTING RV-8 /8 PEX COMPRESSION FITTING RV-7 / COPPER COMPRESSION FITTING RV-NA0 / COPPER SWEAT FITTING RV-90 RADIATOR ADAPTER (MUST BE USED FOR DIRECT PIPE CONNECTION TO RADIATOR - NO DIVERTER OR ISOLATION VALVE) 7

VENT PANEL RADIATORS ECOSTYLE 9 Radiator Piping - Series NOTES: MAX OF RADIATORS ON ONE LOOP THERMOSTATIC HEADS CAN BE USED FOR INDIVIDUAL RADIATOR ADJUSTMENT Baseboard DIVERTER VALVES RV-0 STAIGHT DIVERTING VALVE RV-0 ANGLED DIVERTING VALVE NOTES: ADJUSTABLE BY-PASS FROM 0-0 % PIPE CONNECTIONS - (SOLD PER PAIR) RV-80A /8 PEX COMPRESSION FITTING RV-8 / PEX COMPRESSION FITTING RV-8 /8 PEX COMPRESSION FITTING RV-7 / COPPER COMPRESSION FITTING RV-NA0 / COPPER SWEAT FITTING

VENT 0 PANEL RADIATORS ECOSTYLE Ecostyle Radiator Piping - Monoflow Tee NOTES: MONOFLOW TEES SHOULD BE INSTALLED ON RETURN PIPE FROM RADIATOR SUPPLY AND RETURN TEES MUST BE AT LEAST INCHES APART THERMOSTATIC HEADS CAN BE USED FOR INDIVIDUAL RADIATOR ADJUSTMENT ISOLATION VALVES RV-000 STAIGHT ISOLATING VALVE RV-00 ANGLED ISOLATION VALVE THERMOSTATIC CONTROL RV-00000 THERMOSTATIC CONTROL HEAD PIPE CONNECTIONS - (SOLD PER PAIR) RV-80A /8 PEX COMPRESSION FITTING RV-8 / PEX COMPRESSION FITTING RV-8 /8 PEX COMPRESSION FITTING RV-7 / COPPER COMPRESSION FITTING RV-NA0 / COPPER SWEAT FITTING

VENT PANEL RADIATORS ECOSTYLE Radiator Piping - Manifold MANIFOLD PIPING NOTES: ISOLATION VALVES ARE NOT NECESSARY THERMOSTATIC CONTROL CAN BE USED FOR INDIVIDUAL RADIATOR ADJUSTMENT Towel Warmer 7 7 THERMOSTATIC CONTROL RV-00000 THERMOSTATIC CONTROL HEAD TOWEL BAR VALVES RV-8 ANGLED THERMOSTATIC VALVE RV-9 STRAIGHT THERMOSTATIC VALVE RV- ANGLED SHUT OFF RV- STRAIGHT SHUT OFF PIPE CONNECTIONS - (SOLD PER PAIR) RV-80A /8 PEX COMPRESSION FITTING RV-8 / PEX COMPRESSION FITTING RV-8 /8 PEX COMPRESSION FITTING RV-7 / COPPER COMPRESSION FITTING RV-NA0 / COPPER SWEAT FITTING RV-90 RADIATOR ADAPTER (MUST BE USED FOR DIRECT PIPE CONNECTION TO RADIATOR - NO DIVERTER OR ISOLATION VALVE)

QHT, Inc. www.qhtinc.com QHT, Inc. reserves the right to make changes to this manual without prior notice. 0/7/