TRILOGI 5.3 PLC Ladder Diagram Programmer and Simulator. A tutorial prepared for IE 575 by Dr. T.C. Chang. Use On-Line Help



Similar documents
Programming A PLC. Standard Instructions

Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements

Programmable Logic Controllers

Introduction to LogixPro - Lab

How to read this guide

2011, The McGraw-Hill Companies, Inc. Chapter 5

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

C-more Remote Access with Apple ipad or iphone Tutorial

SIEMENS. Operating Web Server. Opening program and changing message text properties

Remote Access. Table Of Contents. Rev: 3.30, 8/03

Access the UTHSCSA Palo Alto Networks (PAN) VPN using Global Protect VPN client and Two Factor Authentication (2FA)

Using triggers and actions

Siemens AG LOGO! App V1.0.0 LOGO! Edition 03/2013. Manual. Answers for industry.

User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720

BECKHOFF. Application Notes. BC9000: Getting Started Guide. For additional documentation, please visit.

For paid computer support call

Beckhoff TwinCAT. Configuring the TwinCAT I/O System

OSPI SFTP User Guide

How to Use vsphere to Connect to and Manage an ESXi Hypervisor Installation

Chapter 3 Create an EasyBuilder Project... 2

Accessing vlabs using the VMware Horizon View Client for OSX

11. FLOWCHART BASED DESIGN

QAS Small Business for Salesforce CRM

Stage One - Applying For an Assent Remote Access Login

Coyote SP - Installation Notes

Xilinx ISE. <Release Version: 10.1i> Tutorial. Department of Electrical and Computer Engineering State University of New York New Paltz

STEP 7 MICRO/WIN TUTORIAL. Step-1: How to open Step 7 Micro/WIN

Phone: Fax: Box: 230

ZEN-SOFT01-V3. Cat.No.W386-E1-03

Quick Instructions Installing on a VPS (Virtual Private Server)

DVQ-2, DMR8RT, DMR16RT QUICK-START GUIDE

Remote Viewer Recording Backup

The data between TC Monitor and remote devices is exchanged using HTTP protocol. Monitored devices operate either as server or client mode.

Technical Note. Monitoring Ethernet Traffic with Tolomatic ACS & Managed Switch. Contents

To download and install directly to your phone

VoIP Intercom and Elastix Server

Send Video Recordings from the DVR to a FTP Server on your PC

Access the TCNJ Palo Alto Networks VPN using the GlobalProtect VPN client

How to create a dialup connection to an S8X00 Media Server

Gmail Or other POP3

The goal is to program the PLC and HMI to count with the following behaviors:

SNMP Manager User s Manual

domovea remote access tebis

ezsystem elab16m Project 1F: Alarm System (Full Project description)

Macs are not directly compatible with Noetix.

How do I Install and Configure MS Remote Desktop for the Haas Terminal Server on my Mac?

MiraCosta College now offers two ways to access your student virtual desktop.

S-SupremaConfigurationGuide-DOC 7/23/2014. Suprema Biometrics Configuration Guide ACS OnSite Aparato

Packet Tracer 3 Lab VLSM 2 Solution

Using Remote Web Workplace Version 1.01

To download and install directly to your phone

User s Guide for version 5 Page

Connecting to Remote Desktop Windows Users

Using the Push Notifications Extension Part 1: Certificates and Setup

The FlexiSchools Online Order Management System Installation Guide

The FlexiSchools Online Order Management System Installation Guide

How to configure Linksys SPA for VOIP Connections

How to use SURA in three simple steps:

SMS Database System Quick Start. [Version 1.0.3]

Optimum Business SIP Trunk Set-up Guide

Broadband Phone Gateway BPG510 Technical Users Guide

Digital Marquee Series

Home Station ADSL. You may also use the following address (regardless of whether you have changed the primary address or not):

Configuring the Siemens TC35 modems for use with the MI2292

How do I Install and Configure MS Remote Desktop for the Haas Terminal Server on my Mac?

How To Use The Powerpoint 3.5 On A Computer With A Powerpoint 2.5 (Powerpoint) On A Pc Or Macbook 2.2 (Powerstation) On An Iphone Or Ipad (Powerplane)

Application Note. Example of user log on Magelis HMI with XB5S5B2L2 biometric switch. Advanced Technical Support - Brazil. Version: 1.

RTI Integration Release Notes

Terminal Four. Content Management System. Moderator Access

Qsync Install Qsync utility Login the NAS The address is :8080 bfsteelinc.info:8080

ScanWin Installation and Windows 7-64 bit operating system

Using the JNIOR with the GDC Digital Cinema Server. Last Updated November 30, 2012

C-more Remote Access, Data Log, FTP File Transfer, and Tutorial

Microsoft Expression Web

The FlexiSchools Online Order Management System Installation Guide

TelNet Digital Fax. Reference Guide..

SIEMENS S

Configuration and Access of FTP Server

Sync Tool for Clarion NX700/NX509/NP509 Series

QuickPanel Control DeviceNet Master Communications Card (IC754DVNM01) Quick Start Guide. Thursday September 20, 2007

EZ RMC Remote HMI App Application Guide for ios

First Time Off-Campus Remote Desktop Connection ipad Edition

KM Metering Inc. EKM Dash User Manual. EKM Metering Inc. (831)

MAGIC TH6. System Configuration SW Version 2.000

The corresponding control ladder program is shown at below: The content of element comment will be built is shown below

PROGRAMMABLE LOGIC CONTROLLERS Unit code: A/601/1625 QCF level: 4 Credit value: 15

TREND series H.264 DVR Central Management System Quick User Guide

Phone Inventory 1.0 (1000) Installation and Administration Guide

Software installation and configuration IEC-line series

FTP Server Application Guide REV:

Comodo LoginPro Software Version 1.5

Modicon M340 Firmware

Introduction to the MISD Web FTP Client

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

Network Setup Guide. 1 Glossary. 2 Operation. 1.1 Static IP. 1.2 Point-to-Point Protocol over Ethernet (PPPoE)

Apps for Android. Apps for iphone & ipad INS584-3

4.3 Multiview Setup. Configure this section on remote PC Install Multiview

account multiple solutions

Remote monitoring of Crouzet Millenium 3 Using Netbiter EasyConnect EC220 & Netbiter Argos

Transcription:

TRILOGI 5.3 PLC Ladder Diagram Programmer and Simulator A tutorial prepared for IE 575 by Dr. T.C. Chang 1 Use On-Line Help Use on-line help for program editing and TBasic function definitions. 2

Open File Open from local drive (file on your disk). 3 Select the desired file 4

File Open 5 Simulate the Program 6

Simulation Use left button to select an input (push button). Right button to toggle an input. 7 Simulation Click View to show variables. 8

Start Server Need server to connect to a PLC. Set the correct COM port. In networked PLCs use Change PLCID to set PLC ID number. The PLC ID will be saved in the EEPROM of the PLC. 9 Configure Users Click Configure Users. You must be an administrator to enter a new user. This is not for IE 575 students. 10

Enter New User Click Add New Userto add new user. 11 Download program to PLC select PLC 12

Enter Username, Password and Select PLC ID IE 575 students use ie575 and camclass as username and password. 13 Program Transfer to PLC 14

Program Transfer Click Yes on several questions and the program will be transferred. Yes on Reset PLC. 15 On-Line Monitoring 16

On-Line Monitoring Window You may not click on the input to change it. Only input at the PLC will be shown. 17 Disconnect from Server In order to link your TRiLOGI window to a different PLC, you must disconnect it from the current PLC. 18

Connect to Server In the previous example, the server was running on the local PC. You may connect to a server running on a remote PC (anywhere), as long as you have the username and password for the PLC and the IP 19 address of the PC. New Server Change the server IP address. 20

User New Server After the new server has been connected, treat it the same as the local server. No extra example will be given here. 21 Input New Program 22

Enter I/O Table You must define I/O table before you may insert new circuit (rung). 23 I/O Table Click the label name for Input # 1 to enter Switch1. Press enter to enter the name. Click the > button to advance to Output, Relay, Timer, etc. 24

Insert Circuit 25 Insert a Contact Click contact, right click to select Normally Closed contact. Now choose the Input. 26

OR and Contact Insertion point is shown in a green box. After the OR contact is selected, choose a relay from the I/O table. Use the > or the pull down menu to select Relay. 27 Choose a Relay Contact Click on Switch1 to move the insertion point to the right hand side of Switch1. Then click the right arrow to move the insertion point after both contacts. 28

New Insertion Point If the insertion point is not moved here the logic will be (Switch1 * Switch2 )+R1. When the insertion point is moved outside (solid yellow box) the logic becomes (Switch1+R1)*Switch2 29 Insert a Normally Closed Contact Right click contact and select the input. 30

Add an Output Click on the output and select the correct one. 31 Delete the Output and Change to Relay While Out is highlighted, click DEL twice quickly. 32

Replace with Relay Click the output and choose relay from the I/O table. Press Enter to go to next rung. 33 Add New Rung Use the procedure discussed before to enter a new circuit (rung). 34

Insert a Contact Click on Switch2 to choose the insertion point. Right click contact to insert Switch3. 35 Competed Ladder Diagram 36

Add OR Condition Following example is used to show how to edit the ladder diagram. The resultant program may not be correct. Add new element OR (Switch2 *Switch3 ). Click on Switch2, then, click element 5. Element 5 change to close on the right hand side. Select the close point. 37 Close the OR Logic Click the contact to close, then, click element 5. 38

New Element Complete An AND condition is added. 39 Insert Custom Function Double click here to add a new rung. 40

Add a Special Bit 0.1s Pulse Every 0.1 second, the contact will close then open. 41 Select Custom Function The output of the rung is a custom function. 42

Select Delta Custom Function 1 Edit custom function using the edit menu or right click Function_1. 43 Edit Custom Function Type the Tbasic program. May edit other custom function. When editing is done, close the editor. 44

Simulate the Program This program will run two stepper motors continuously. Since the function is called every 0.1 second. 45 Replace the Clock with R1 Right click on Clk:0.1s and enter R1 in the Edit Label Name box. 46

Simulate the Modified Program 47