Vacuum. How It Relates to Refrigeration And Air Conditioning Service



Similar documents
Rusty Walker, Corporate Trainer Hill PHOENIX

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigeration Basics 101. By: Eric Nelson

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Automobile Air Conditioning Primer

System Diagnosis. Proper vehicle diagnosis requires a plan before you start

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Triple Point Experiment

Compressed air systems. How to plan, install and operate. Best Practices for Maintenance Management

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Compressors Buying Guide

MAC-120HE-01 Air-Cooled Chiller

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

ON-VEHICLE INSPECTION

How To Understand Evaporator

High Performance Vacuum Pump Model 15401/15601/15603/15605 Operating Manual... 2

DESIGN STANDARDS SECTION

HOW HVAC WORKS. How HVAC. Works PAGE 1

SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION)

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

10ACC WARNING WARNING. Service Literature 10ACC SERIES UNITS

Gas Line Sizing. Z Maximum gas demand shall be determined by adding all of the equipment Btu ratings from appliances connected on the system.

How To Clean Water From An Ammonia Refrigeration System

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Vacuum chucking. MDAE Woodturning Center Course Number

Steam System Best Practices Condensate System Piping

HVAC Super Pro FAQ. Can HVAC SUPER PRO be used on both hard and soft copper and aluminum tubing?

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Contents and Nomenclature

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Recharge Procedure for Telemark TVP-2000 and TVP-3500

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

Model 1210C Battery Powered Pump Shown. Description

HVAC-02, Air Conditioning Troubleshooting and Repair

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

Section IV VACUUM PUMPS. Vacuum Pumps: Basic Operation

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

This chapter is devided into two sections:

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

Dehumidification Frequently Asked Questions

Glossary of Heating, Ventilation and Air Conditioning Terms

CENTRAL HEAT PUMP AND AIR CONDITIONER INSTALLATION

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

THE HUMIDITY/MOISTURE HANDBOOK

Recommended Compressor Installation Practices

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois Information compiled by Frank Prah, CMS

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Refrigerant Changeover Guidelines R-502 to R-402A/R-408A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

COMPRESSOR REPLACEMENT PROCEDURE

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

In recent years, formicary corrosion has wreaked havoc on. Micro-channel

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

MAINTENANCE INSTRUCTIONS FOR THE CLEAN-FLO CONTINUOUS LAMINAR FLOW INVERSION / OXYGENATION SYSTEM

INSTALLATION INSTRUCTIONS

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

A/C refrigerant system, overview

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

How to Choose the Right Air Compressor

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Many Products...One Source

Model 2128 AIR COMPRESSOR PUMP Operating Instructions

ThermoStar Refrigeration Air Dryers

Training Manual SUPER SEAL. Simplifying AC/R Repair. Inside Your Guide PROFESSIONAL FORMULA. Page

Heavy-Duty Air Conditioning And Heater Service

YELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

Test Code: 8297 / Version 1

COMPRESSOR REPLACEMENT PROCEDURE

A brief explanation on how air conditioning works and what terms mean

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Fluid Power Formula. These Formula Cover All Fluid Power Applications In This Manual

UNDERSTANDING REFRIGERANT TABLES

Physical Chemistry Laboratory I CHEM 445 Experiment 6 Vapor Pressure of a Pure Liquid (Revised, 01/09/06)

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC

EXPERIMENT 15: Ideal Gas Law: Molecular Weight of a Vapor

SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.

REFRIGERATION & AIR CONDITIONING GUIDE

Lawn Sprinkler Systems Reserve Irrigation Inc. O & M. Version Roseland Drive Macedonia, Ohio

Measurement Solutions for Refrigeration Technology.

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

US VACUUM CP SERIES MANUAL. Oil Lubricated, Rotary Vane Vacuum Pumps INSTALLATION OPERATION. Models CPS-5B & CPS-8B WARNING

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

This will also provide you with the knowledge to insure long life for your Investment

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

Compressed Air Filters

Description of a Basic Vacuum System

Flushing and Cleaning the A/C System

Transcription:

Vacuum How It Relates to Refrigeration And Air Conditioning Service

Moisture In A Refrigeration System Visible Moisture Water Droplets Uncommon, but it can occur Invisible Moisture Water Vapor Found in all gasses Found in all solids

Visible Moisture Problems Freeze Ups Ice crystal formation at the point of expansion Cap Tube blocked TXV Flow Rator The problems will be intermittent When the system warms up the problem stops

Air in the piping Invisible Moisture Wet Refrigerant Leaks Under a Vacuum Condition Copper and Brass Components System Components exposed to atmosphere during assembly

Invisible Moisture Causes Corrosion Moisture Reacts With The Metals Metal H2O corrosion

Moisture & Refrigerant Moisture Refrigerant ACID

Moisture & Refrigerant CFC & HCFC & HFC Hydrolyze to form Hydrochloric Acid Hydrofluoric Acid Acid Formation Is Accelerated By Heat Copper and Brass Will Be Attacked Plates Hot Surfaces Bearings Seize

Copper Plating

Moisture & Refrigerant & Oil Metal Refrigerant Acid Oil Sludge

How Do You Get The Water Out? We Boil It We Can t Raise The System Temperature To 212 We Lower the System Pressure To A Point That Water Boils At Ambient Temperatures

Pressure VS. Boiling Point Physics 101 As Pressure Decreased - The Boiling Point Decreases To Decrease The Pressure We Can Raise The System To A Higher Altitude There Is Less Atmosphere Above Us On Mt. Evans Less Weight Of Air = Lower Air Pressure

Pressure VS. Boiling Point Sea Level Pressure = 14.7 PSI. Boiling Point = 212 F. Pike s Peak (14000 + Elevation) Pressure = 8.32 PSI. Boiling Point = 184 F. Still Not Low Enough

Pressure VS. Boiling Point To Boil Water @ 80 F. The Pressure Has To be Lowered To 28.92 Inches Of Mercury To Boil Water @ 45F The Pressure Has To Be Lowered To 29.62 Inches Of Mercury Vacuum or 7620 Microns

What The Heck Is A Micron? 1 Inch = 25400 Microns.039 Inch = 1000 Microns = 1 Millimeter 1 Micron = 1/1,000,000 meter To Small To Measure With A Gauge.

How Is Vacuum Measured? 25400 microns between each mark

How Is Vacuum Measured? Compound Gauge Impossible Vacuum Gauge Resolution Is Not Suitable Reading Changes with Altitude (pressure) U Tube Manometer Resolution To 1 MM of Mercury (1000 Microns)

How Is Vacuum Measured? Thermistor Micron Gauge Measures The Last Inch Of Vacuum Regardless of Atmospheric Pressure High Resolution Readings To 1 Micron

How Is Vacuum Measured?

Thermistor Micron Gauge Measures The Thermal Conductivity Of The Gas Remaining in the Refrigeration System Has A Source Of Heat Has A Heat Receptor The Thermistor

Thermistor Micron Gauge Hose to System Heat Source Thermistor The more gas left---- The higher the Temperature on Thermistor

Thermistor Micron Gauge Hose to System Heat Source Thermistor Less Gas..Less Heat Received.Lower Reading

Vacuum Pumps Air Compressor Type Moves Large Volume Of Air At Low Pressures (Can t Achieve Deep Vacuum) At Best 28 of Mercury No water Boiled

Vacuum Pumps Piston Compressor Type At Best 29 (at Sea Level) That Won t Boil Water Under 80F Rotary Compressor Type 29.63 (at Sea Level) Water Boils @ 45F Unsuitable For Systems Larger Than Household Refrigerators

High Vacuum Rotary Vane Pumps Single Stage Smaller Light Weight 1000 Microns Robinair down to 200 Microns

Single Stage

High Vacuum Rotary Vane Pumps Two Stage Vacuum Pumps Most Common For Service Larger CFM Capacity Slightly Heavier Than Single Stage Of Same Capacity Can Achieve Deeper Vacuum Than Single Stage Because Second Stage Takes Over At The Level 1st Stage Stops

High Vacuum Rotary Vane Pumps Two Stage (cont..) Can Pull To One Micron Robinair Guaranty 20 Microns

Two Stage Vacuum Pumps

Two Stage Vacuum Pumps ISO Valve 1st stage 2nd Stage

Rotor & Vanes Off Set Construction Vanes Come Out At Low RPM To wipe The Interior Of Pump 1st Stage Are Ceramic Vanes 2nd Stage Are Aluminum

Gas Ballast Valve Mixes Dry Air With High Humidity Air Reduces Moisture That Is Condensed Into The Oil Makes Oil Last Longer

Gas Ballast Valve Open Valve At Beginning Evacuation When A level Of 1000 Microns Is Achieved, Close Valve

Speed Of Evacuation Size Of System Complexity Of Piping System Components Oil Separators Accumulators Valves Ambient Temperature Size Of Pump How You are Hooked Up To the System High & Low Side Size Of Hoses Access Fitting?

Speed Of Evacuation Use Largest Hoses You Can Add Heat To Areas Of Restriction Get the Access Fittings Out Of Way Measure Vacuum At The System Isolate The System And Equalize To Get A True Reading

Access Core Removal Tool

How Much Pump? Vacuum Pumps Are Rated In Cubic Feet Per Minute Of Free Air Through the Pump As A Rule Of thumb 1 CFM Per 7 Tons Of System I.E. A 6 CFM Rated Pump Will Be Good For 42 Tons Of System Capacity Multiple Pumps OK

Make Your Pump Last 25 Years Keep Your Pump Warm Cold Starts Are Hard On The Pump Don t Start Or Stop Pump In A Vacuum Vane Pocket Fill With Oil If The Pump Is Shut Down In A Vacuum

Make Your Pump Last 25 Years Always Expose Pump To Atmosphere On Shut Down Change The Oil Every Time