CommScope Fiber Optic Cable Products > Loose Tube > Central Tube > Fiber Drop > Hybrids > Tight Buffered FIBER OPTIC CABLE PRODUCTS
CommScope Fiber Optic Cable Fiber Optic Cable Overview... F3 Fiber Optic Catalog Numbering Key... F7 Cabled Fiber Specifications Singlemode Fiber... F8 Multimode Fiber Specifications... F11 Loose Tube Cable Designs Dry Stranded Loose Tube Armored... F13 Dry Stranded Loose Tube All-Dielectric... F14 Dry Double Jacketed/Single Armored Stranded Loose Tube... F15 Arid-Core Stranded Loose Tube Armored... F16 Arid-Core Stranded Loose Tube All-Dielectric... F17 Arid-Core Double Jacketed/Single Armored Stranded Loose Tube... F18 Arid-Core Mini Stranded Loose Tube Armored... F19 Arid-Core Mini Stranded Loose Tube Non-Armored... F20 LSZH Arid-Core Mini Stranded Loose Tube Armored... F21 LSZH Arid-Core Mini Stranded Loose Tube Non-Armored... F22 High Density Stranded Loose Tube... F23 ADSS Short Span Stranded Loose Tube... F24 Self-Supporting Figure-8 Dry Stranded Loose Tube Armored (0.250in)... F25 Self-Supporting Figure-8 Dry Stranded Loose Tube Non-Armored (0.250in)... F26 Self-Supporting Figure-8 Arid-Core Dry Stranded Loose Tube Armored (0.250in)... F27 Self-Supporting Figure-8 Arid-Core Dry Stranded Loose Tube Non-Armored (0.250in)... F28 Self-Supporting Figure-8 Dry Stranded Loose Tube Armored (0.188in)... F29 Self-Supporting Figure-8 Dry Stranded Loose Tube Non-Armored (0.188in)... F30 Self-Supporting Figure-8 Dry Stranded Loose Tube Armored (0.109in)... F31 Self-Supporting Figure-8 Dry Stranded Loose Tube Non-Armored (0.109in)... F32 Riser-Rated, Indoor/Outdoor Dry Stranded Loose Tube All-Dielectric... F33 Plenum-Rated, Indoor/Outdoor Dry Stranded Loose Tube All-Dielectric... F34 Riser-Rated, Indoor/Outdoor Dry Stranded Loose Tube with Interlocking Armor... F35 Plenum-Rated, Indoor/Outdoor Dry Stranded Loose Tube with Interlocking Armor... F36 Central Tube Cable Designs Central Tube Armored... F37 Central Tube All-Dielectric... F37 Riser-Rated, Indoor/Outdoor Central Tube All-Dielectric... F38 Fiber Drop Cable Designs Drop Armored... F39 Drop All-Dielectric... F40 Messengered Drop (0.109in)... F41 Messengered Drop (0.083in)... F42 Figure-8 Mini-Drop (Solid Messenger)... F43 Flat Drop... F44 Toneable Flat Drop... F45 LSZH, Indoor/Outdoor Central Tube All-Dielectric... F46 ConQuest Fiber Optic Products... F47 Hybrid Cable Designs Fiber/Coax Designs... F51 Fiber/Twisted Pair Designs... F53 Fiber/Tone Wire Designs... F55 Tight Buffered Cable Designs Riser-Rated, Indoor/Outdoor LSZH Distribution... F58 Riser-Rated, Indoor/Outdoor LSZH Cordage... F59 Riser-Rated, Indoor Distribution... F60 Riser-Rated, Indoor Cordage... F61 Plenum Rated, Indoor Distribution... F62 Plenum-Rated, Indoor Cordage... F63 Packaging and Shipping Information... F64 33 F2
CommScope Proven Quality and Performance The Cable Industry s Fiber Supplier TM Better fiber equals better fiber optic cable. CommScope provides key optical and geometrical features in its standard singlemode fiber for fusion splice compatibility with other fiber manufacturers and legacy fiber. LightScope ZWP singlemode optical fiber cable continues a CommScope tradition of being a leader in manufacturing innovative and performanceenhanced products for the cable industry. LightScope ZWP optical fiber cable makes available 30% more usable transmission spectrum, which can be used for return path, enhanced video services such as video on demand (VOD) or Dedicated Wavelength Services for business or other demanding applications. CommScope has developed key families of fiber optic cables specifically to be used throughout the HFC communication hierarchy as well as an offering of fiber optic components including connectors and other passive devices that are commonly required in broadband infrastructure. Outside Plant Cables for Standard and Rugged Environments For direct buried, underground conduit and aerial installations, CommScope offers several designs, which include a variety of loose tube cables. Design options include Drop Armored, a smaller, lighter weight Central Tube cable construction; Central Tube, Flat Drop, and Stranded Loose Tube cables. Craft friendly product solutions are a foremost requirement in today s fast paced world. CommScope engineers are committed to offering evolutionary improvements and easy-to-handle constructions in our fiber product offering. For example, our Dry Loose Tube family of gel-free stranded loose tube cables uses all-dry water blocking technology and reduced diameter buffer tubes. The design is completely gel-free, yet provides full water blocking protection for outside plant applications. Any of these cables may be factory-installed in a variety of CommScope s ConQuest premium high density polyethylene TM conduit including Toneable Conduit a patented location and damage prevention solution. Indoor/Outdoor Cables for Strength and Safety - Including Low-Smoke Zero-Halogen (LSZH) Types CommScope s design for these cables offer construction and jacketing suitable for outside usage yet comply with UL and CSA riser (OFNR) or plenum (OFNP) flame standards. This design allows you to run cable through the building entrance without having to terminate and splice different cables together which results in significant savings in time and labor. Cable types include dielectric central tube designs, dielectric stranded loose tube cables and Triathlon, a specially designed low-smoke/zero halogen distribution and cordage cable construction. Premise Cables for Safety and Performance CommScope s premises cables are designed to handle the unique stresses of indoor applications. Design options include riser and plenum-rated distribution and cordage cables. 32 F3
Test Reports - A Higher Standard for Higher Speeds Every reel of CommScope fiber optic cable is subjected to stringent testing throughout the entire manufacturing process. Our state-of-the-art process controls and testing systems ensure that every meter of CommScope cable consistently meets or exceeds our high standards. To prove that our fiber optic cables exceed industry standards, we go to the extra step of attaching an individual cable test report to each reel. In addition to the paper copy of the test reports, we also offer WebTrak, a web program that puts cabling factory results on-line for all of our fiber optic cables. It is our understanding that sometimes this critical test information is misplaced or never makes it to the end-user. With WebTrak, it is easy to find that important paperwork; CommScope s web interface puts factory testing reports for individual cables on-line for 24 hour immediate access. The patented and trademarked WebTrak program resides on our commscope.com website for quick access from any computer. For access to the electronic test reports, all the installers need is the 11 digit serial number printed on the cable jacket and a footage or meter marker for reference. Installers can then enter this number on the WebTrak portion of the CommScope website and pull up the cable s factory test results from anywhere in the world at any time of the day or night. Provides documentation of CommScope fiber optic cable performance, allowing a convenient way to track a reel of cable and verify performance. Provides an alternative to managing paper reports. With WebTrak, you can get all the information you need on-line. Provides quick verifications to ensure the product meets or exceeds performance requirements, should there be a performance issue in the field. Provides easy 24/7 access via the internet. WebTrak is just one more example of how CommScope listens to our customers and delivers. You get proof-positive that the cable you purchase will perform to the level you require. Remember, a network is only as good as the cable that connects it. Specify the cables that make networks work fiber optic cables from CommScope. Request a FREE Broadband Applications & Construction Library CommScope s Broadband Applications & Construction Library includes a 5-piece set of valuable reference manuals plus a DVD containing essential training videos on topics such as connectorization, expansion loop formation and fiber optic splicing. These tools teach you how to protect the integrity of your broadband plant while lowering operating/installation costs. From construction and installation practices, to performance and testing of cable CommScope Construction Manuals are simply a must-have for anyone upgrading or maintaining broadband networks. Download a PDF version at our website: http://www.commscope.com or request a set by phone at 1-800-982-1708. CommScope s TM Broadband Resource Center This repository of experience, knowledge, services and tools is provided to CommScope customers to assist installers, technicians, engineers, designers and managers of broadband service providers. Tools in various media and formats include: SpanMaster software for cable sag and tension calculations; center conductor sizing guides; attenuation slide rules; and call center spec assistance and review. Call us at 1-866-333-3BRC (3272) or e-mail brc@commscope.com for answers to product questions or issues related to any CommScope broadband product. 33 F4
CommScope Outside Plant Cables Robust Dielectric and Armored Constructions All CommScope Outside Plant (OSP) cables are designed and manufactured to provide outstanding mechanical and optical performance. This cable family includes a loose tube construction to provide multiple levels of protection for the fiber strands. We manufacture all loose tube cables with appropriate Excess Fiber Length (EFL) to ensure, that when properly installed, the fiber strands will remain strain-free, which is essential to good optical performance and longevity. Our heavyduty products are engineered to withstand the rigors of environmental extremes. There are many cable choices when considering applications that require environmental protection and provide for network diversity. CommScope cable surpasses requirements in the aerial, underground and conduit applications. We offer self-support cable for aerial environments and cable-in-conduit or armored cables for extra protection in burial applications. CommScope manufactures cables that are lightweight, flexible and especially suited for aerial cable installations. Our loose tube cables are available in armored and alldielectric versions. OSP Fiber Optic Cable Design Options Include: Drop - a small, lightweight Central Tube cable designed for use when space is at a minimum; features a robust PBT buffer tube and is available in fiber counts up to 12 Central Tube - armored and dielectric construction for point-to-point installations in counts up to 96 arranged in easy-to-handle color-coded subunits of 12 fiber each Stranded Loose Tube - for direct buried, underground conduit and aerial installations; design variations range from all-dielectric to armored constructions with up to 576 fibers Dry Loose Tube Craft friendly product solutions are a foremost requirement in today s fast paced world. CommScope engineers are committed to offering evolutionary improvements and easyto-handle constructions in our fiber product offering. The latest example is our new Dry Loose Tube cable design. This family of gel-free stranded loose tube cables uses all-dry water blocking technology and reduced diameter buffer tubes. The design is completely gel-free, yet provides full water blocking protection for outside plant applications and meets all of the requirements for outside plant cable. Arid-Core Moisture Barrier CommScope defeats moisture with a unique multi-level approach. In addition to tough outer jacketing, we employ Arid-Core, a super-absorbent polymer technology. Arid-Core is applied between the jacket and the buffer tubes in stranded loose tube cables, and coats the central tubes of drop armored and central tube cables. When moisture meets Arid-Core, the polymer swells to prevent moisture migration - it acts as a mechanical block to prevent further water penetration. CommScope OSP fiber optic cables are designed to meet or exceed the requirements of Telcordia, EIA/TIA, REA/RUS, IEC and RUS industry standards. Drop Cables CommScope s Drop family of cables offer craft friendly access product solutions for Fiber to the Premise (FTTP) applications designed for use as systems develop commercial services and expand networks to non-traditional customers. The design of drop cables compliments the needs often found for the last mile of your fiber network. Drop cables offer a compact, flexible and cost-efficient configuration that provides low-loss performance when twelve fibers or less are needed. Drop cables are commonly used to branch from the main cable route to outlying distribution points or the premise. All drop cables can be pre-installed in conduit. 32 F5
CommScope Cable Constructions Stranded Loose Tube Available in All-Dielectric and Armored designs with up to 576 fibers For Direct Buried, Underground Conduit, and Aerial installations Available in ADSS and Figure-8 constructions Hybrid configurations that include coax or copper conductors are available Mini-Diameter Stranded Loose Tube Smaller, lightweight cable design utilizing 2.0mm buffer tubes Available with up to 144 fibers in Armored, All- Dielectric and LSZH designs Improved ease of handling and better utilization of duct space Indoor/Outdoor Stranded Loose Tube Riser, Plenum, and Low Smoke Zero Halogen (LSZH) constructions Eliminates the need for a splice point when entering a building Tough enough for the OSP environment and flame rated for indoor use Drop Cost effective, low fiber count cables for outside plant applications Wide variety of flexible, versatile, and craft-friendly products available For Direct Buried, Underground Conduit, and Aerial Drop applications Small, lightweight cable designs developed for ease of installation Hybrid Cables Flexibility and options for future growth in a single cost-effective cable run Easier material management Capable of voice transmission, cable location, and site powering Messenger Figure-8 Multiple messenger size options for increased versatility in designs with up to 60 fibers Allows easy, one-step installation resulting in cost savings Armored and Non-Armored versions with.250 messenger available with up to 288 fibers Central Tube Available in All-Dielectric and Armored designs with up to 96 fibers Effective solution for point-to-point installations Robust constructions offer excellent fiber protection Single buffer tube saves time and reduces termination costs Premise Cables Complete line of Riser and Plenum rated cables for indoor use Engineered to provide excellent mechanical and optical performance FiberGuard Aluminum Interlocking Armor available 33 F6
Fiber Optic Catalog Numbering Key Steps to Building the Catalog Number for the Cable You Need! CommScope Catalog Number Position 1 2 3 4 5 6 7 8 9 10 11 12 CABLE STYLE (Position 1) D...Dry O...Outdoor (Arid Core Standard) S...Self-Supporting (ADSS) M...Messenger P...Plenum R...Riser Z...Zero Halogen FIBER COUNT* (Positions 2, 3, & 4) Total Fiber Count (in increments of two) *Substitute for XXX variable in catalog number. CONSTRUCTION (Positions 5 & 6) Loose Tube Cables LA...Stranded Loose Tube Armored LN...Stranded Loose Tube Non-Armored L2...Stranded Loose Tube Double Jacketed, Single Armored LZ...Indoor/Outdoor Stranded Loose Tube, Aluminum Interlocking Armor DA...Drop Armored DN...Drop Non-Armored DF...Flat Drop MN...Mini-Drop Non-Armored CA...Central Tube Armored CN...Central Tube Non-Armored, All-Dielectric Tight Buffered Cables DS...Distribution SP...Simplex IC...Interconnect ZC...Zipcord CABLE MARKING (Position 9) F...Jacket Sequentially Marked in Feet (standard) M...Jacket Sequentially Marked in Meters X...Custom Print Required CABLE CONSTRUCTION SPECIFICS (Position 10) For outdoor and indoor/outdoor loose tube cables, this value indicates the fiber content per subunit: 01-12...Fiber Count Per Subunit For indoor distribution cables, this value indicates additional information pertaining to the cable construction: SU...Single Unit Construction MU...Multi-Unit Construction For cordage cables, this value indicates the outside diameter: 16...1.6mm Jacket Outer Diameter 25...2.5mm Jacket Outer Diameter 29...2.9mm Jacket Outer Diameter COLOR FIELD (Positions 11 & 12) For outdoor cables, this field designates the tracer/stripe requirements: NS...No Stripe (Std) WH...White BL...Blue YL...Yellow OR...Orange VI...Violet GR...Green For indoor/outdoor cables, this field designates the jacket color: BK...Black For indoor cables, this field designates jacket color: OR... Orange -62.5 µm multimode and composite cables YL...Yellow - singlemode cables AQ...Aqua - 50 µm multimode LazrSPEED cables FIBER TYPE (Positions 7 & 8) Singlemode 8W...LightScope ZWP Dispersion-Unshifted, Matched-Clad, Singlemode Fiber 8F...Bend Insensitive Singlemode Fiber 8T...LightScope NZD TM Shifted, Singlemode Fiber Multimode 6F...62.5µm, FDDI Grade, Multimode Fiber 5M...LazrSPEED CM...Composite (Singlemode & Multimode) Hybrids HY...Fiber/Copper *XY variable in catalog number Note: Non-standard jacket colors are available. (minimum order required) Please contact your Customer Service Representative for additional information. ZZ variable in catalog number NOTES When Positions 7 & 8 are CM (composite cables), positions 14-23 are required. Positions 14 & 15... Singlemode fiber type Positions 16-18... Singlemode fiber count (aaa variable in the catalog number) Positions 19 & 20... Multimode fiber type Positions 21-23... Multimode fiber count (bbb variable in the catalog number) Please note that positions 13 and above are often used to differentiate similar cable constructions. Please see the individual product pages for additional part number details. F7
Type 8W Singlemode Fiber Specifications Available in All CommScope Cable Types Zero Water Peak: Dispersion-Unshifted, Standards Compliance: ITU-T G.652.D Physical Characteristics Cladding Diameter 125 ± 0.7 µm Core/Clad Offset < 0.5 µm Coating Diameter (uncolored) 245 ± 10 µm Coating Diameter (colored) 254 ± 7 µm Coating/Cladding Concentricity Error, maximum 12 µm Clad Non-Circularity < 1% Mechanical Characteristics Proof Test 100 kpsi (.69 Gpa) Coating Strip Force 0.3-2.0 lbf (1.3-8.9 N) Fiber Curl > 4 m Dynamic Fatigue Parameter > 20 nd Macrobend 100 turns @ 50 mm mandrel 1310/1550 nm 0.05 db maximum Macrobend 100 turns @ 60 mm mandrel 1625nm 0.05 db maximum Macrobend 1 turn @ 32 mm mandrel 1550 nm 0.05 db maximum Optical Characteristics, Wavelength Specific Attenuation, Loose Tube Cable 1310 nm 0.34 db/km 1385 nm 0.31 db/km 1550 nm 0.22 db/km Attenuation, Tight Buffer Cable 1310 nm 0.50 db/km 1385 nm 0.50 db/km 1550 nm 0.50 db/km Mode Field Diameter 1310 nm 9.2 + 0.3 µm 1385 nm 9.6 + 0.6 µm 1550 nm 10.4 + 0.5 µm Group Refractive Index 1310 nm 1.467 1385 nm 1.468 1550 nm 1.468 Dispersion 1310 nm 3.2 ps/(nm-km) from 1285 to 1330 nm 1550 nm 18 ps/(nm-km) Optical Characteristics, General Point Defects, maximum Cutoff Wavelength Zero Dispersion Wavelength Zero Dispersion Slope Polarization Mode Dispersion Link Design Value 0.10 db < 1260 nm 1302-1322 nm 0.090 ps/(km-nm-nm) < 0.06 ps/sqrt(km) Environmental Characteristics Temperature Dependence -60 C to +85 C Temperature Humidity Cycling -10 C to +85 C up to 95% RH Water Immersion, 23 + 2 C Heat Aging, 85 + 2 C < 0.05 db < 0.05 db < 0.05 db < 0.05 db F8
Bend Insensitive Type 8F Singlemode Fiber Specifications Available in All CommScope Cable Types Dispersion-Unshifted, Standards Compliance: ITU-T G.657.A Physical Characteristics Cladding Diameter 125 ± 0.7 µm Core/Clad Offset < 0.5 µm Coating Diameter (uncolored) 245 ± 10 µm Coating Diameter (colored) 254 ± 7 µm Coating/Cladding Concentricity Error, maximum 12 µm Clad Non-Circularity < 1% Mechanical Characteristics Proof Test 100 kpsi (.69 Gpa) Coating Strip Force 0.3-2.0 lbf (1.3-8.9 N) Fiber Curl > 4 m Dynamic Fatigue Parameter > 18 nd Macrobend 100 turns @ 50 mm diameter (maximum) 1550 nm 0.01 db 1625 nm 0.05 db Macrobend 10 turns @ 30 mm diameter (maximum) 1550 nm 0.2 db 1625 nm 0.5 db Macrobend 1 turn @ 30 mm diameter (maximum) 1550 nm 0.02.dB Macrobend 1 turn @ 20 mm diameter (maximum) 1550 nm 0.2 db Optical Characteristics, Wavelength Specific Attenuation, Loose Tube Cable 1310 nm 0.36 db/km 1385 0.33 db/km 1550 nm 0.25 db/km Attenuation, Tight Buffer Cable 1310 nm 0.50 db/km 1385 nm 0.50 db/km 1550 nm 0.50 db/km Mode Field Diameter 1310 nm 8.9 + 0.4 µm 1550 nm 10.0 + 0.5 µm Group Refractive Index 1310 nm 1.467 1385 nm 1.467 1550 nm 1.468 Dispersion 1310 nm 3.5 ps/(nm-km) from 1285 to 1330 nm 1550 nm 18 ps/(nm-km) Optical Characteristics, General Point Defects, maximum Cutoff Wavelength Zero Dispersion Wavelength Zero Dispersion Slope Polarization Mode Dispersion Link Design Value 0.10 db < 1260 nm 1302-1322 nm 0.092 ps/(km-nm-nm) < 0.06 ps/sqrt(km) F9 Environmental Characteristics Temperature Dependence -60 C to +85 C Temperature Humidity Cycling -10 C to +85 C up to 95% RH Water Immersion, 23 + 2 C Heat Aging, 85 + 2 C < 0.05 db < 0.05 db < 0.05 db < 0.05 db
LightScope NZD TM Type 8T Singlemode Fiber Specifications Available in CommScope Outside Plant Cable Types Non-Zero Dispersion Standards Compliance: ITU-T G.655.C, D Physical Characteristics Cladding Diameter 125 ± 0.7 µm Core/Clad Offset < 0.5 µm Coating Diameter (uncolored) 245 ± 5 µm Coating Diameter (colored) 256 ± 8 µm Coating/Cladding Concentricity Error, maximum 10 µm Clad Non-Circularity < 0.7% Mechanical Characteristics Proof Test 100 kpsi (.69 Gpa) Coating Strip Force 0.3-2.0 lbf (1.3-8.9 N) Fiber Curl Dynamic Fatigue Parameter Macrobend 100 turns @ 75mm mandrel > 4 m > 20 nd 1550 and 1625 nm 0.05 db maximum Macrobend 1 turn @ 32mm mandrel 1550 and 1625nm 0.50 db maximum Optical Characteristics, Wavelength Specific Attenuation, Loose Tube Cable 1310 nm 0.45 db/km 1550 nm 0.25 db/km 1625 nm 0.34 db/km Mode Field Diameter 1550 nm 8.4 + 0.6 µm 1625 nm 8.9 + 0.6 µm Group Refractive Index 1310 nm 1.471 1550 nm 1.470 1625 nm 1.470 Dispersion 1310 nm -8 ps/(nm-km) (typical) 1550 nm 2.6 to 6 ps/(nm-km) from 1530-1565 nm 1625 nm 4.0 to 8.9 ps/(nm-km) from 1565-1625 nm Optical Characteristics, General Maximum Attenuation at 1385 nm Point Defects, maximum Cutoff Wavelength Dispersion Slope Polarization Mode Dispersion Link Design Value 0.45 db/km 0.10 db < 1260 nm < 0.05 ps/(km-nm-nm) at 1550 nm < 0.04 ps/sqrt(km) Environmental Characteristics Temperature Dependence -60 C to +85 C Temperature Humidity Cycling -10 C to +85 C up to 95% RH Water Immersion, 23 + 2 C Heat Aging, 85 + 2 C < 0.05 db < 0.05 db < 0.05 db < 0.05 db F10
Type 6F Multimode Fiber Specifications Available in All CommScope Cable Types 62.5 micron, FDDI Grade Multimode Fiber Standards Compliance: TIA 492AAAA (OM1) Physical Characteristics Core Diameter 62.5 ± 2.5 µm Cladding Diameter 125 ± 1.0 µm Core/Clad Offset < 1.0 µm Coating Diameter (uncolored) 245 ± 10 µm Coating Diameter (colored) 254 ± 7 µm Coating/Cladding Concentricity Error, maximum 8 µm Clad Non-Circularity < 1% Mechanical Characteristics Proof Test 100 kpsi (.69 Gpa) Coating Strip Force 0.3-2.0 lbf (1.3-8.9 N) Dynamic Fatigue Parameter > 18 nd Macrobend 100 turns @ 75mm mandrel 850 nm and 1300 nm 0.50 db maximum Optical Characteristics, Wavelength Specific Attenuation, Loose Tube Cable 850 nm 3.0 db/km 1300 nm 1.0 db/km Attenuation, Tight Buffer Cable 850 nm 3.4 db/km 1300 nm 1.0 db/km Bandwidth, OFL (Over-Filled Launch) 850 nm 220 MHz - km 1300 nm 500 MHz - km Group Refractive Index 850 nm 1.496 1300 nm 1.491 1 GB Ethernet Distance 850 nm 300 m 1300 nm 550 m Optical Characteristics, General Numerical Aperature 0.275 ± 0.015 Point Defects, maximum 0.15 db Zero Dispersion Wavelength 1320-1365 nm Zero Dispersion Slope, maximum 0.097 ps/(km-nm-nm) Environmental Characteristics Temperature Dependence -60 C to +85 C Temperature Humidity Cycling -10 C to +85 C up to 95% RH Water Immersion, 23 + 2 C Heat Aging, 85 + 2 C < 0.20 db < 0.20 db < 0.20 db < 0.20 db F11
LazrSPEED 150 Type 5M Multimode Fiber Specifications Available in All CommScope Cable Types LazrSPEED 150, 50 micron Multimode Fiber Standards Compliance: Exceeds TIA 492AAAB (OM2+) Physical Characteristics Core Diameter 50.0 ± 2.5 µm Cladding Diameter 125 ± 1.0 µm Core/Clad Offset < 1.5 µm Coating Diameter (uncolored) 245 ± 10 µm Coating Diameter (colored) 255 ± 7 µm Coating/Cladding Concentricity Error, maximum 6 µm Clad Non-Circularity < 1% Mechanical Characteristics Proof Test 100 kpsi (.69 Gpa) Coating Strip Force 0.3-2.0 lbf (1.3-8.9 N) Dynamic Fatigue Parameter > 18 nd Macrobend 100 turns @ 75mm mandrel 850 nm and 1300 nm 0.50 db maximum Optical Characteristics, Wavelength Specific Attenuation, Loose Tube Cable 850 nm 3.0 db/km 1300 nm 1.0 db/km Attenuation, Tight Buffer Cable 850 nm 3.0 db/km 1300 nm 1.0 db/km Bandwidth, OFL 850 nm 700 MHz - km 1300 nm 500 MHz - km Bandwidth, Laser 850 nm 950 MHz - km 1300 nm 500 MHz - km Differential Mode Delay 850 nm 0.70 ps/m 1300 nm 0.88 ps/m Group Refractive Index 850 nm 1.483 1300 nm 1.479 1 GB Ethernet Distance 850 nm 800 m 1300 nm 600 m 10 GB Ethernet Distance 850 nm 150 m Optical Characteristics, General Numerical Aperature 0.200 + 0.015 Point Defects, maximum 0.15 db Zero Dispersion Wavelength 1297-1316 nm Zero Dispersion Slope 0.105 ps/(km-nm-nm) Environmental Characteristics Temperature Dependence -60 C to +85 C Temperature Humidity Cycling -10 C to 85 C up to 95% RH Water Immersion, 23 + 2 C Heat Aging, 85 + 2 C 0.10 db 0.10 db 0.20 db 0.20 db F12
Outside Plant Gel-Free Stranded Loose Tube Cable Armored Jacket/Armor Combinations for Buried/Underground/Aerial Applications 100% dry stranded loose tube cable reduces cable prep time and keeps gel from getting on clothes, workbenches, or splicing equipment Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ Single Armor D-XXX-LA-XY-F12NS 5 0.45/11.5 6.8/17.3 4.5/11.5 607/2700 180/800 78 116 2-60 Fibers 62-72 Fibers D-XXX-LA-XY-F12NS 6 0.47/12.0 7.1/18.0 4.7/12.0 607/2700 180/800 82 123 74-96 Fibers D-XXX-LA-XY-F12NS 8 0.53/13.6 8.0/20.3 5.3/13.6 607/2700 180/800 103 154 98-120 Fibers D-XXX-LA-XY-F12NS 10 0.60/15.1 8.9/22.7 6.0/15.1 607/2700 180/800 126 188 122-144 Fibers D-XXX-LA-XY-F12NS 12 0.68/17.2 10.2/25.8 6.8/17.2 607/2700 180/800 158 235 146-216 Fibers D-XXX-LA-XY-F12NS 18 0.68/17.2 10.2/25.8 6.8/17.2 607/2700 180/800 141 209 218-288 Fibers D-XXX-LA-XY-F12NS 24 0.77/19.6 11.6/29.4 7.7/19.6 607/2700 180/800 177 264 Singlemode/Multimode Composite (4-288 Fibers) D-XXX-LA-CM-F12NS/AAaaa/BBbbb Refer to above specifications. Buffer Tubes 13-24 repeat color sequence with tracer stripe F13 Gel-Free Stranded Loose Tube Armored Cable (72 Fiber Version Shown) PE Outer Jacket Steel Tape Armoring Water Swellable Tape 2.5mm Gel-Free Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (2) Installation Temperature Operating Temperature Storage Temperature -22 to +158 F (-30 to +70 C) -40 to +158 F (-40 to +70 C) -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105; RUS/RDUP 7 CFR 1755.902 RD Telecommunications Program Listed.
Outside Plant Gel-Free Stranded Loose Tube Cable Non-Armored, All-Dielectric For Buried/Underground/Aerial Applications 100% dry stranded loose tube cable reduces cable prep time and keeps gel from getting on clothes, workbenches, or splicing equipment Lightweight, small design is installer-preferred due to ease of handling Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ 2-60 Fibers D-XXX-LN-XY-F12NS 5 0.40/10.2 6.0/15.3 4.0/10.2 607/2700 180/800 45 66 62-72 Fibers D-XXX-LN-XY-F12NS 6 0.42/10.6 6.3/15.9 4.2/10.6 607/2700 180/800 49 73 74-96 Fibers D-XXX-LN-XY-F12NS 8 0.48/12.2 7.2/18.3 4.8/12.2 607/2700 180/800 64 96 98-120 Fibers D-XXX-LN-XY-F12NS 10 0.54/13.8 8.1/20.6 5.4/13.8 607/2700 180/800 83 123 122-144 Fibers D-XXX-LN-XY-F12NS 12 0.62/15.8 9.3/23.7 6.2/15.8 607/2700 180/800 107 159 146-216 Fibers D-XXX-LN-XY-F12NS 18 0.62/15.8 9.3/23.7 6.2/15.8 607/2700 180/800 90 134 218-288 Fibers D-XXX-LN-XY-F12NS 24 0.72/18.2 10.8/27.3 7.2/18.2 607/2700 180/800 122 181 Singlemode/Multimode Composite (4-288 Fibers) D-XXX-LN-CM-F12NS/AAaaa/BBbbb Refer to above specifications. Buffer Tubes 13-24 repeat color sequence with tracer stripe Gel-Free Stranded Loose Tube Non-Armored, All-Dielectric Cable (72 Fiber Version Shown) PE Outer Jacket Water Swellable Tape 2.5mm Gel-Free Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105; RUS/RDUP 7 CFR 1755.902 RD Telecommunications Program Listed. F14
Outside Plant Gel-Free Stranded Loose Tube Cable Double Jacketed, Single Armored Double Jacket for Buried/Underground/Aerial Applications 100% dry stranded loose tube cable reduces cable prep time and keeps gel from getting on clothes, workbenches, or splicing equipment Corrugated steel tape is strong yet flexible, providing additional crush and rodent protection Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Double Jacket/ Single Armor D-XXX-L2-XY-F12NS 5 0.59/15.0 8.9/22.5 5.9/15.0 607/2700 180/800 129 192 2-60 Fibers 62-72 Fibers D-XXX-L2-XY-F12NS 6 0.61/15.4 9.1/23.1 6.1/15.4 607/2700 180/800 134 200 74-96 Fibers D-XXX-L2-XY-F12NS 8 0.67/17.0 10.0/25.4 6.7/17.0 607/2700 180/800 160 238 98-120 Fibers D-XXX-L2-XY-F12NS 10 0.73/18.5 10.9/27.8 7.3/18.5 607/2700 180/800 189 281 122-144 Fibers D-XXX-L2-XY-F12NS 12 0.81/20.6 12.2/30.9 8.1/20.6 607/2700 180/800 224 334 146-216 Fibers D-XXX-L2-XY-F12NS 18 0.81/20.6 12.2/30.9 8.1/20.6 607/2700 180/800 207 308 218-288 Fibers D-XXX-L2-XY-F12NS 24 0.90/23.0 13.6/34.5 9.0/23.0 607/2700 180/800 255 380 Singlemode/Multimode D-XXX-L2-CM-F12NS/AAaaa/BBbbb Composite (4-288 Fibers) Refer to above specifications. F15 Gel-Free Stranded Loose Tube Armored Cable Double Jacketed, Single Armored (72 Fiber Version Shown) PE Outer Jacket Steel Tape Armoring Water Blocking Tape 2.5mm Gel-Free Buffer Tubes PE Inner Jacket Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (2) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105; RUS/RDUP 7 CFR 1755.902 RD Telecommunications Program Listed.
Outside Plant Arid-Core Stranded Loose Tube Cable Armored Jacket/Armor Combinations for Buried/Underground/Aerial Applications Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ Single Armor O-XXX-LA-XY-F12NS/25T 5 0.45/11.5 6.8/17.2 4.5/11.5 607/2700 180/800 81 121 2-60 Fibers 62-72 Fibers O-XXX-LA-XY-F12NS/25T 6 0.47/11.9 7.0/17.9 4.7/11.9 607/2700 180/800 86 128 74-96 Fibers O-XXX-LA-XY-F12NS/25T 8 0.53/13.5 8.0/20.2 5.3/13.5 607/2700 180/800 108 161 98-120 Fibers O-XXX-LA-XY-F12NS/25T 10 0.59/15.1 8.9/22.6 5.9/15.1 607/2700 180/800 133 197 122-144 Fibers O-XXX-LA-XY-F12NS/25T 12 0.68/17.2 10.1/25.7 6.8/17.2 607/2700 180/800 165 246 146-216 Fibers O-XXX-LA-XY-F12NS/25T 18 0.68/17.2 10.1/25.7 6.8/17.2 607/2700 180/800 153 228 218-288 Fibers O-XXX-LA-XY-F12NS/25T 24 0.77/19.5 11.5/29.3 7.7/19.5 607/2700 180/800 194 288 Singlemode/Multimode Composite (4-288 Fibers) O-XXX-LA-CM-F12NS/25T/AAaaa/BBbbb Refer to above specifications. Buffer Tubes 13-24 repeat color sequence with tracer stripes Arid-Core Stranded Loose Tube Armored Cable (72 Fiber Version Shown) PE Outer Jacket Steel Tape Armoring Water Swellable Tape 2.5 mm Gel Filled Buffer Tubes Water Blocking Gel Dielectric Strength Member Strength Elements 250 Micron Fiber Ripcord (2) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F16
Outside Plant Arid-Core Stranded Loose Tube Cable Non-Armored, All-Dielectric For Buried/Underground/Aerial Applications Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Lightweight, small design is installer-preferred due to ease of handling Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ 2-60 Fibers O-XXX-LN-XY-F12NS/25T 5 0.40/10.2 6.0/15.3 4.0/10.2 607/2700 180/800 48 71 62-72 Fibers O-XXX-LN-XY-F12NS/25T 6 0.42/10.5 6.2/15.8 4.2/10.5 607/2700 180/800 52 78 74-96 Fibers O-XXX-LN-XY-F12NS/25T 8 0.48/12.1 7.2/18.2 4.8/12.1 607/2700 180/800 69 103 98-120 Fibers O-XXX-LN-XY-F12NS/25T 10 0.54/13.7 8.1/20.6 8.1/13.7 607/2700 180/800 89 133 122-144 Fibers O-XXX-LN-XY-F12NS/25T 12 0.62/15.8 9.3/23.7 6.2/15.8 607/2700 180/800 114 170 146-216 Fibers O-XXX-LN-XY-F12NS/25T 18 0.62/15.8 9.3/23.7 6.2/15.8 607/2700 180/800 102 153 218-288 Fibers O-XXX-LN-XY-F12NS/25T 24 0.72/18.2 10.7/27.3 7.2/18.2 607/2700 180/800 138 206 Singlemode/Multimode Composite (4-288 Fibers) O-XXX-LN-CM-F12NS/25T/AAaaa/BBbbb Refer to above specifications. Buffer Tubes 13-24 repeat color sequence with tracer stripes Arid-Core Stranded Loose Tube Non-Armored, All-Dielectric Cable (72 Fiber Version Shown) PE Outer Jacket Water Swellable Tape 2.5 mm Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F17
Multi-Jacketed Stranded Loose Tube Cable Double Jacketed, Single Armored Jacket/Armor Combinations for Buried/Underground/Aerial Applications Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km Double Jacket/ Single Armor O-XXX-L2-XY-F12NS/25T 5 0.59/15.0 8.8/22.4 5.9/15.0 607/2700 180/800 132 196 2-60 Fibers 62-72 Fibers O-XXX-L2-XY-F12NS/25T 6 0.60/15.3 9.0/23.0 6.0/15.3 607/2700 180/800 138 205 74-96 Fibers O-XXX-L2-XY-F12NS/25T 8 0.67/16.9 10.0/25.3 6.7/16.9 607/2700 180/800 164 245 98-120 Fibers O-XXX-L2-XY-F12NS/25T 10 0.73/18.5 10.9/27.7 7.3/18.5 607/2700 180/800 195 290 122-144 Fibers O-XXX-L2-XY-F12NS/25T 12 0.81/20.6 12.1/30.8 8.1/20.6 607/2700 180/800 232 345 146-216 Fibers O-XXX-L2-XY-F12NS/25T 18 0.81/20.6 12.1/30.8 8.1/20.6 607/2700 180/800 220 327 218-288 Fibers O-XXX-L2-XY-F12NS/25T 24 0.90/22.9 13.6/34.4 9.0/22.9 607/2700 180/800 272 404 Singlemode/Multimode O-XXX-L2-CM-F12NS/25T/AAaaa/BBbbb Composite (4-288 Fibers) *Other jacket/armor configurations available upon request. Refer to above specifications. Double Jacket/Single Armor Loose Tube Cable (72 Fiber Version Shown) PE Outer Jacket Ripcord (2) Steel Tape Armoring Water Blocking Tape 2.5 mm Buffer Tubes PE Inner Jacket Dielectric Strength Member 250 Micron Fibers Water Blocking Tape Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105; RUS/RDUP CFR 1755.902 RD Telecommunications Program Listed F18
Outside Plant Arid-Core Mini Stranded Loose Tube Cable Armored Jacket/Armor Combinations for Buried/Underground/Lashed Aerial Applications Very small 2.0 mm buffer tubes improve kink resistance and facilitate route management in closures Lightweight, small design is installer-preferred due to ease of handling Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Smaller form factor cable can be utilized for tight duct spaces Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ Single Armor 2-72 Fibers O-XXX-LA-XY-FZZNS/20T 6 0.43/10.8 6.4/16.2 4.3/10.8 607/2700 180/800 79 117 74-96 Fibers O-XXX-LA-XY-FZZNS/20T 8 0.48/12.1 7.2/18.2 4.8/12.1 607/2700 180/800 92 137 98-120 Fibers O-XXX-LA-XY-FZZNS/20T 10 0.52/13.1 7.8/19.7 5.2/13.1 607/2700 180/800 108 160 122-144 Fibers O-XXX-LA-XY-FZZNS/20T 12 0.58/14.6 8.6/22.0 5.8/14.6 607/2700 180/800 134 200 Mini-Diameter Stranded Loose Tube Cable (72 Fiber Armored Version Shown) PE Outer Jacket Steel Tape Armoring Water Swellable Tape 2.0 mm Gel Filled Buffer Tubes Water Blocking Gel Dielectric Strength Member Strength Elements 250 Micron Fiber Ripcord (2) Installation Temperature Operating Temperature Storage Temperature -22 to +158 F (-30 to +70 C) -40 to +158 F (-40 to +70 C) -40 to +167 F (-40 to +75 C) Compression (Armored) 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC 60794-1-2, Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F19
Outside Plant Arid-Core Mini Stranded Loose Tube Cable Non-Armored, All-Dielectric For Buried/Underground/Lashed Aerial Applications Lightweight, small design is installer-preferred due to ease of handling Smaller form factor cable which can be utilized for tight duct space requirements Small and flexible 2.0mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitates route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ 2-72 Fibers O-XXX-LN-XY-F12NS/20T 6 0.37/9.5 5.6/14.3 3.7/9.5 607/2700 180/800 48 72 74-96 Fibers O-XXX-LN-XY-F12NS/20T 8 0.41/10.5 6.2/15.7 4.1/10.5 607/2700 180/800 58 86 98-120 Fibers O-XXX-LN-XY-F12NS/20T 10 0.46/11.8 6.9/17.6 4.6/11.8 607/2700 180/800 71 106 122-144 Fibers O-XXX-LN-XY-F12NS/20T 12 0.52/13.3 7.8/19.9 5.2/13.3 607/2700 180/800 92 138 Arid-Core Mini Stranded Loose Tube Non-Armored, All-Dielectric Cable (72 Fiber Version Shown) PE Outer Jacket Water Swellable Tape 2.0 mm Gel Filled Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F20
Indoor/Outdoor LSZH Arid-Core Mini Stranded Loose Tube Cable Low-Smoke Zero-Halogen, Armored For Indoor/Outdoor Applications that Require a LSZH Rating Helps eliminate transition splicing at the building entrance Lightweight, small design is installer-preferred due to ease of handling Flexible 2.0mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management UV-resistant jacket suitable for use outdoors Corrugated steel armor is strong yet flexible providing additional crush and rodent protection Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ 2-72 Fibers Z-XXX-LA-XY-F12BK/20G 6 0.48/12.3 7.3/18.5 4.8/12.3 607/2700 180/800 123 183 74-96 Fibers Z-XXX-LA-XY-F12BK/20G 8 0.54/13.6 8.0/20.4 5.4/13.6 607/2700 180/800 143 213 98-120 Fibers Z-XXX-LA-XY-F12BK/20G 10 0.58/14.6 8.6/21.9 5.8/14.6 607/2700 180/800 166 248 122-144 Fibers Z-XXX-LA-XY-F12BK/20G 12 0.64/16.1 9.5/24.2 6.4/16.1 607/2700 180/800 201 300 LSZH Arid Core Mini Stranded Loose Tube Armored Cable (72 Fiber Version Shown) LSZH Outer Jacket Steel Tape Armoring Water Swellable Tape 2.0 mm Gel Filled Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (1) Flame Test Specifications Flame Test Listing NEC Type: OFNR-LS (ETL) and c(etl) Flame Test Standard UL-1666, UL-1685, IEC 60332-3, IEC 61034-2; IEC 60754-2, IEEE 383 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-104-696-2001; Telcordia GR-20-CORE Issue 2; EN 187105 F21
Indoor/Outdoor LSZH Mini Stranded Loose Tube Cable Low-Smoke Zero-Halogen, Non-Armored, All-Dielectric For Indoor/Outdoor Applications that Require a LSZH Rating Helps eliminate transition splicing at the building entrance Lightweight, small design is installer-preferred due to ease of handling Flexible 2.0mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management UV-resistant jacket suitable for use outdoors Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Single Jacket/ 2-72 Fibers Z-XXX-LN-XY-F12BK/20G 6 0.43/11.0 6.5/16.5 4.3/11.0 607/2700 180/800 85 127 74-96 Fibers Z-XXX-LN-XY-F12BK/20G 8 0.47/12.0 7.1/18.0 4.7/12.0 607/2700 180/800 101 151 98-120 Fibers Z-XXX-LN-XY-F12BK/20G 10 0.52/13.3 7.8/19.9 5.2/13.3 607/2700 180/800 123 183 122-144 Fibers Z-XXX-LN-XY-F12BK/20G 12 0.58/14.7 8.7/22.0 5.8/14.7 607/2700 180/800 151 225 LSZH Mini Stranded Loose Tube Non-Armored, All-Dielectric Cable (72 Fiber Version Shown) LSZH Outer Jacket Water Swellable Tape 2.0 mm Gel Filled Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (1) Flame Test Specifications Flame Test Listing NEC Type: OFNR-LS (ETL) and c(etl) Flame Test Standard UL-1666, UL-1685, IEC 60332-3, IEC 61034-2; IEC 60754-2, IEEE 383 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-104-696-2001; Telcordia GR-20-CORE Issue 2; EN 187105 F22
Outside Plant Stranded Loose Tube Cable High Density Loose Tube For Buried/Underground/Aerial Applications Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Flexible buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures Eliminates the need for ribbonized fibers by giving you a compact cable with up to 576 loose fibers Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Armored 290-432 Fibers O-XXX-LA-XY-F24NS 18 0.90/22.9 13.5/34.3 9.0/22.9 607/2700 180/800 241 358 434-576 Fibers O-XXX-LA-XY-F24NS 24 1.03/26.2 15.4/39.2 10.3/26.2 607/2700 180/800 310 461 All Dielectric 290-432 Fibers O-XXX-LN-XY-F24NS 18 0.85/21.5 12.7/32.2 8.5/21.5 607/2700 180/800 173 258 434-576 Fibers O-XXX-LN-XY-F24NS 24 0.98/24.8 14.6/37.2 9.8/24.8 607/2700 180/800 233 347 Double Jacketed Single Armored O-XXX-L2-XY-F24NS 18 1.02/25.9 15.3/38.9 10.2/25.9 607/2700 180/800 337 501 290-432 Fibers 434-576 Fibers O-XXX-L2-XY-F24NS 24 1.15/29.2 17.3/43.8 11.5/29.2 607/2700 180/800 423 630 Buffer Tubes 13-24 repeat color sequence with tracer stripe All-Dielectric High Density Loose Tube Fiber Cable (432 Fiber Version Shown) PE Outer Jacket Strength Elements 3.5 mm Gel Filled Buffer Tube Dielectric Strength Member Fiber Threads Water Swellable Tape 250 Micron Optical Fibers Ripcord (1) Subunit Detail Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression (dielectric) 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Compression (armored) 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F23
ADSS Short Span Loose Tube Cable All-Dielectric, Self-Supporting (ADSS) Aerial Design For Aerial Long Haul and Metro Applications Small cable diameter and bend radius for lightweight and ease of handling and installation Designed for aerial spans requiring a self-supporting, non-messengered product Single Medium Density Polyethylene (MDPE) jacket for fast convenient cable preparation Fully qualified in accordance with Telcordia Technologies, EIA/TIA and IEEE Standards Product Type/ Catalog Sub Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Units inch/mm Loaded Unloaded Short Term Long Term l bs/ kg/ inch/cm lbs/newtons kft km kft km Single Jacket 2-60 Fibers S-XXX-LN-XY-F12NS/NFB 5 0.46/11.8 7.0/17.7 4.6/11.8 960/4270 775/3447 66 99 Other ADSS designs are available upon request. Buffer Tubes 13-24 repeat color sequence with tracer stripe Custom Sag & Tension Tables are available upon request. ADSS Double Jacket Loose Tube All-Dielectric Cable (60 Fiber Version Shown) PE Outer Jacket Aramid Strength Elements 3.0mm Gel-Filled Buffer Tube Dielectric Strength Member Water Swellable Tape Ripcord (1) 250 Micron Fibers Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F24
Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube Armored For Aerial Applications Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Uses standard figure-8 cable hardware and installation practices 100% gel-free stranded loose tube cable reduces cable prep time Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Minimum Bend Radius Weight Product Type/ Catalog Buffer Cable OD Cable Height Messenger Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/cm Jacket. OD inch/cm inch/cm kft km Figure-8 Armored 2-60 Fibers M-XXX-LA-XY-F12NS/ 5 0.47/11.9 0.89/22.5 0.33/8.3 7.0/17.8 4.7/11.9 230 342 25D Figure-8 Armored Cable (60 Fiber Version Shown) MPDE Outer Jacket Stranded 0.25 Galvanized Steel Messenger Steel Tape Armoring Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F25
Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube Non-Armored For Aerial Applications Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Uses standard figure-8 cable hardware and installation practices 100% gel-free stranded loose tube cable reduces cable prep time Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip \ Cable Outer Messenger Minimum Bend Radius Weight Product Type/ Catalog Buffer Diameter Cable Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/cm inch/mm inch/cm inch/cm kft km Figure-8 Non-Armored 2-60 Fibers M-XXX-LN-XY-F12NS/ 5 0.41/10.5 0.85/21.7 0.33/8.3 16.5/42.0 8.2/21.0 200 299 25D Figure-8 Self-Supporting Non-Armored Cable (60 Fiber Version Shown) MDPE Outer Jacket Stranded 0.25 Flooded Steel Messenger Water Swellable Tape Strength Elements 2.5 mm Gel-Free Buffer Tube Dielectric Strength Member 250 Micron Fiber Ripcord Installation Temperature Operating Temperature Storage Temperature -22 to +158 F (-30 to +70 C) -40 to +158 F (-40 to +70 C) -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F26
Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube Armored For Aerial Applications Figure-8 cable design allows easy, one-step installation resulting in cost savings Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Uses standard figure-8 cable hardware and installation practices Cable Outer Messenger Minimum Bend Radius Weight Product Type/ Catalog Sub Diameter Cable Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm inch/cm lbs/newtons kft km Figure-8 Armored 2-60 Fibers M-XXX-LA-XY-F12NS 5 0.51/13.0 0.95/24.2 0.35/8.9 7.7/19.4 5.1/13.0 251 373 62-72 Fibers M-XXX-LA-XY-F12NS 6 0.55/14.0 0.99/25.1 0.35/8.9 8.2/20.9 5.5/14.0 267 397 74-144 Fibers M-XXX-LA-XY-F12NS 12 0.79/20.2 1.24/31.4 0.35/8.9 11.9/30.3 7.9/20.2 372 554 146-216 Fibers M-XXX-LA-XY-F12NS 18 0.79/20.2 1.24/31.4 0.35/8.9 11.9/30.3 7.9/20.2 357 531 218-288 Fibers M-XXX-LA-XY-F12NS 24 0.91/23.2 1.35/34.4 0.35/8.9 13.7/34.7 9.1/23.2 424 633 Figure-8 Armored Cable (72 Fiber Version Shown) MPDE Outer Jacket Stranded 0.25 Galvanized Steel Messenger Steel Tape Armoring Water Swellable Tape 3.0 mm Gel Filled Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F27
Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube Non-Armored For Aerial Applications Figure-8 cable design allows easy, one-step installation resulting in cost savings Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Standard color-coding on fibers and buffer tubes helps ease installation All buffer tubes are constructed to a nominal OD of 3mm reducing the number of tools required in the field Uses standard figure-8 cable hardware and installation practices Cable Outer Messenger Minimum Bend Radius Weight Product Type/ Catalog Sub Diameter Cable Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm inch/cm lbs/newtons kft km Figure-8 Non-Armored 2-60 Fibers M-XXX-LN-XY-F12NS 5 0.46/11.6 0.90/22.8 0.35/8.9 6.8/17.4 4.6/11.6 214 318 2-72 Fibers M-XXX-LN-XY-F12NS 6 0.50/12.6 0.94/23.8 0.35/8.9 7.4/18.9 5.0/12.6 227 338 74-144 Fibers M-XXX-LN-XY-F12NS 12 0.74/18.8 1.18/30.0 0.35/8.9 11.1/28.2 7.4/18.8 313 466 146-216 Fibers M-XXX-LN-XY-F12NS 18 0.74/18.8 1.18/30.0 0.35/8.9 11.1/28.2 7.4/18.8 298 443 218-288 Fibers M-XXX-LN-XY-F12NS 24 0.86/21.8 1.30/33.0 0.35/8.9 12.9/32.7 8.6/21.8 349 520 Figure-8 Non-Armored Cable (72 Fiber Version Shown) MDPE Outer Jacket Stranded 0.25 Galvanized Steel Messenger Water Swellable Tape Strength Elements 3.0 mm Gel-Filled Buffer Tube Dielectric Strength Member 250 Micron Fiber Ripcord Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F28
Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube Armored For Aerial Applications 100% gel-free stranded loose tube cable reduces cable prep time Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Cable Outer Cable Messenger Maximum Bend Radius Weight Product Type/ Catalog Buffer Diameter Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/mm inch/mm inch/cm lbs/newtons kft km Figure-8 Armored 2-60 Fibers M-XXX-LA-XY-F12NS/ 5 0.47/11.9 0.83/21.1 0.27/6.9 7.0/17.8 4.7/11.9 180 267 25D/188 Figure-8 Armored Cable (60 Fiber Version Shown) MPDE Outer Jacket Stranded 3/16 Galvanized Steel Messenger Steel Tape Armoring Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F29
Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube, Non-Armored For Aerial Applications 100% gel-free stranded loose tube cable reduces cable prep time Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Cable Outer Cable Messenger Maximum Bend Radius Weight Product Type/ Catalog Buffer Diameter Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/mm inch/mm inch/cm lbs/newtons kft km Figure-8 Non-Armored 2-60 Fibers M-XXX-LN-XY-F12NS/ 5 0.41/10.5 0.78/19.7 0.27/6.9 6.2/15.8 4.1/10.5 146 217 25D/188 Figure-8 Non-Armored Cable (60 Fiber Version Shown) MPDE Outer Jacket Stranded 3/16 Galvanized Steel Messenger Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F30
Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube, Armored For Aerial Applications 100% gel-free stranded loose tube cable reduces cable prep time Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Cable Outer Cable Messenger Maximum Bend Radius Weight Product Type/ Catalog Buffer Diameter Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/mm inch/mm inch/cm lbs/newtons kft km Figure-8 Armored 2-60 Fibers M-XXX-LA-XY-F12NS/ 5 0.47/11.9 0.75/19.2 0.20/5.0 7.0/17.8 4.7/11.9 124 185 25D/109 Figure-8 Armored Cable (60 Fiber Version Shown) MPDE Outer Jacket 0.109 Galvanized Steel Messenger Steel Tape Armoring Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F31
Outside Plant Self-Supporting Figure-8 Cable Messengered Stranded Loose Tube, Non-Armored For Aerial Applications 100% gel free stranded loose tube cable reduces cable prep time Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Cable Outer Cable Messenger Maximum Bend Radius Weight Product Type/ Catalog Buffer Diameter Height Jacket OD Loaded Unloaded lbs/ kg/ Fiber Count Number Tubes inch/mm inch/mm inch/mm inch/cm lbs/newtons kft km Figure-8 Non-Armored 2-60 Fibers M-XXX-LN-XY-F12NS/ 5 0.41/10.5 0.70/17.8 0.20/5.0 6.2/15.8 4.1/10.5 90 134 25D/109 Figure-8 Non-Armored Cable (60 Fiber Version Shown) MPDE Outer Jacket 0.109 Galvanized Steel Messenger Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F32
Indoor/Outdoor Stranded Loose Tube Cable Riser-Rated For Indoor/Outdoor Applications that Require a Riser Rating All meet critical NEC/CEC riser (OFNR) safety standards, eliminating the need for splice point at building entrance 100% gel free stranded loose tube cable reduces cable prep time Lightweight, small design is installer-preferred due to ease of handling Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km Single Jacket 2-60 Fibers R-XXX-LN-XY-F12BK/25D 5 0.45/11.5 6.8/17.3 4.5/11.5 607/2700 180/800 79 118 62-72 Fibers R-XXX-LN-XY-F12BK/25D 6 0.47/11.9 7.1/17.9 4.7/11.9 607/2700 180/800 85 127 74-96 Fibers R-XXX-LN-XY-F12BK/25D 8 0.53/13.5 8.0/20.3 5.3/13.5 607/2700 180/800 109 161 98-120 Fibers R-XXX-LN-XY-F12BK/25D 10 0.59/15.1 8.9/22.6 5.9/15.1 607/2700 180/800 130 193 122-144 Fibers R-XXX-LN-XY-F12BK/25D 12 0.68/17.2 10.1/25.7 6.8/17.2 607/2700 180/800 176 262 146-216 Fibers R-XXX-LN-XY-F12BK/25D 18 0.70/17.8 10.5/26.7 7.0/17.8 607/2700 180/800 162 240 218-288 Fibers R-XXX-LN-XY-F12BK/25D 24 0.79/20.2 11.9/30.2 7.9/20.2 607/2700 180/800 208 309 Singlemode/Multimode Composite (4-288 Fibers) R-XXX-LN-XY-F12BK/25D/AAaaa/BBbbb Refer to above specifications. Buffer Tubes 13-24 repeat color sequence with tracer stripe F33 Riser-Rated Indoor/Outdoor Stranded Loose Tube Cable (72 Fiber Version Shown) PVC Outer Jacket Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member Strength Element 250 Micron Fiber Ripcord Flame Test Specifications Flame Test Listing NEC Type OFNR (ETL) and c(etl) Flame Test Standard UL-1666 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105
Indoor/Outdoor Stranded Loose Tube Cable Plenum-Rated For Indoor/Outdoor Applications that Require a Plenum Rating Combines application spaces of building interconnect and plenum in a campus environment Dielectric design is lightweight, easy to access and does not require grounding 100% gel-free stranded loose tube cable reduces cable prep time Water blocking prevents moisture migration Temperature range is fully outside plant rated Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km Single Jacket 2-60 Fibers P-XXX-LN-XY-F12BK/25D 5 0.38/9.7 5.7/14.6 3.8/9.7 600/2700 180/800 64 96 61-72 Fibers P-XXX-LN-XY-F12BK/25D 6 0.40/10.1 6.0/15.2 4.0/10.1 600/2700 180/800 71 105 74-96 Fibers P-XXX-LN-XY-F12BK/25D 8 0.46/11.7 6.9/17.5 4.6/11.7 600/2700 180/800 95 142 98-120 Fibers P-XXX-LN-XY-F12BK/25D 10 0.52/13.3 7.8/19.9 5.2/13.3 600/2700 180/800 124 185 122-144 Fibers P-XXX-LN-XY-F12BK/25D 12 0.60/15.3 9.1/23.0 6.0/15.3 600/2700 180/800 168 250 Singlemode/Multimode Composite (4-144 Fibers) P-XXX-LN-CM-F12BK/25D/AAaaa/BBbbb Refer to above specifications. Buffer Tubes 13-24 repeat color sequence with tracer stripe Plenum-Rated Indoor/Outdoor Stranded Loose Tube Cable (72 Fiber Version Shown) Plenum-Rated Outer Jacket Water Swellable Tape 2.5mm Gel Free Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fiber Ripcord (1) Flame Test Specifications Flame Test Listing NEC Type OFNP (ETL) and c(etl) Flame Test Standard NFPA-262 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105 F34
Indoor/Outdoor FiberGuard TM Stranded Loose Tube Cable Riser-Rated For Indoor/Outdoor Applications that Require a Riser Rating Cables are protected with an interlocking armor to shield against damage Well suited for construction and renovations, heavy industry and high security area applications Aluminum interlocking armor with overall jacket NEC/CEC compliant Outstanding mechanical protection for sensitive cables combined with excellent flexibility Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Buffer Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Tubes inch/mm inch/cm inch/cm Short Term Long Term kft km 2-60 Fibers R-XXX-LZ-XY-FZZBK/25D 5 0.81/20.5 16.1/40.9 11.3/28.6 300/1335 90/400 215 320 62-72 Fibers R-XXX-LZ-XY-FZZBK/25D 6 0.81/20.5 16.1/40.9 11.3/28.6 300/1335 90/400 221 328 74-96 Fibers R-XXX-LZ-XY-FZZBK/25D 8 0.86/21.7 17.1/43.5 12.0/30.4 300/1335 90/400 254 378 98-120 Fibers R-XXX-LZ-XY-FZZBK/25D 10 0.91/23.0 18.1/46.0 12.7/32.2 300/1335 90/400 285 424 122-144 Fibers R-XXX-LZ-XY-FZZBK/25D 12 1.01/25.5 20.1/51.1 14.1/35.7 300/1335 90/400 329 489 146-216 Fibers R-XXX-LZ-XY-FZZBK/25D 18 1.06/26.8 21.1/53.6 14.8/37.5 300/1335 90/400 323 481 218-288 Fibers R-XXX-LZ-XY-FZZBK/25D 24 1.11/28.1 22.1/56.2 15.5/39.3 300/1335 90/400 378 563 Singlemode/Multimode Composite (4-288 Fibers) R-XXX-LZ-XY-FZZBK/25D/AAaaa/BBbbb Refer to above specifications. Buffer Tubes 13-24 repeat color sequence with tracer stripe Riser-Rated Indoor/Outdoor Stranded Loose Tube Cable (72 Fiber Version Shown) Riser-Rated Outer Jacket Interlocking Aluminum Armor Riser-Rated Inner Jacket Strength Elements Water Swellable Tape Dielectric Strength Member 250 Micron Fiber 2.5 mm Gel Free Buffer Tubes Ripcord(1) Flame Test Specifications Flame Test Listing NEC Type OFCR (ETL) and c(etl) Flame Test Standard UL-1666 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 483 lbf/in (85 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Flex 25 Cycles FOTP-24; IEC 60794-1-2; Sec. 10 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105 F35
Indoor/Outdoor FiberGuard TM Stranded Loose Tube Cable Plenum-Rated For Indoor/Outdoor Applications that Require a Plenum Rating Cables are protected with an interlocking armor to shield against damage Well suited for construction and renovations, heavy industry and high security area applications Aluminum interlocking armor with overall jacket 100% gel-free stranded loose tube cable reduces cable prep time Outstanding mechanical protection for sensitive cables combined with excellent flexibility Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Buffer Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Tubes inch/mm inch/cm inch/cm Short Term Long Term kft km 2-60 Fibers P-XXX-LZ-XY-FZZBK/25D 5 0.71/17.9 14.1/35.8 9.9/25.1 300/1335 90/400 192 286 62-72 Fibers P-XXX-LZ-XY-FZZBK/25D 6 0.71/17.9 14.1/35.8 9.9/25.1 300/1335 90/400 199 296 74-96 Fibers P-XXX-LZ-XY-FZZBK/25D 8 0.81/20.5 16.1/40.9 11.3/28.6 300/1335 90/400 245 365 98-120 Fibers P-XXX-LZ-XY-FZZBK/25D 10 0.86/21.7 17.1/43.5 12.0/30.4 300/1335 90/400 285 425 122-144 Fibers P-XXX-LZ-XY-FZZBK/25D 12 0.96/24.3 19.1/48.5 13.4/34.0 300/1335 90/400 330 491 Singlemode/Multimode Composite (4-288 Fibers) P-XXX-LZ-XY-FZZBK/25D/AAaaa/BBbbb Refer to above specifications. Buffer Tubes 13-24 repeat color sequence with tracer stripe Plenum-Rated Indoor/Outdoor Stranded Loose Tube Cable (72 Fiber Version Shown) Plenum-Rated Outer Jacket Interlocking Aluminum Armor Plenum-Rated Inner Jacket Strength Elements Water Swellable Tape Dielectric Strength Member 250 Micron Fiber 2.5 mm Gel Free Buffer Tubes Ripcord(1) Flame Test Specifications Flame Test Listing NEC Type OFCP (ETL) and c(etl) Flame Test Standard NFPA-262 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 483 lbf/in (85 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Flex 25 Cycles FOTP-24; IEC 60794-1-2; Sec. 10 Cable Freeze +28 F (-2 C) FOTP-98 Drip N/A N/A ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105 F36
Outside Plant Central Tube Cable Armored and All-Dielectric Designs For Buried/Underground/Aerial Applications Robust constructions offer excellent protection of fibers Provides easy access to the fibers Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Product Type/ Catalog Subunits Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Armored O-XXX-CA-XY-F12NS 2 0.43/11.0 6.5/16.5 4.3/11.0 607/2700 180/800 91 135 2-24 Fibers, 4mm Tube 26-48 Fibers, 6mm Tube O-XXX-CA-XY-F12NS 4 0.51/13.0 7.7/19.5 5.1/13.0 607/2700 180/800 118 176 50-96 Fibers, 8mm Tube O-XXX-CA-XY-F12NS 8 0.59/15.0 8.9/22.5 5.9/15.0 607/2700 180/800 148 220 All-Dielectric O-XXX-CN-XY-F12NS 2 0.40/10.1 5.9/15.1 4.0/10.1 607/2700 180/800 63 94 2-24 Fibers, 4mm Tube 26-48 Fibers, 6mm Tube O-XXX-CN-XY-F12NS 4 0.48/12.1 7.2/18.2 4.8/12.1 607/2700 180/800 86 128 50-96 Fibers, 8mm Tube O-XXX-CN-XY-F12NS 8 0.55/14.1 8.3/21.1 5.5/14.1 607/2700 180/800 110 164 Singlemode/Multimode O-XXX-CA-CM-F12NS/AAAaa/BBbbb Refer to above specifications. Composite (4-96 Fibers) O-XXX-CN-CM-F12NS/AAaaa/BBbbb (Tube size will vary depending on fiber count/configuration.) Central Tube Armored Cable (24 Fiber Version Shown) Steel RSM (2) Ripcord for Armor Access (2) PE Outer Jacket Gel 4.0 mm Buffer Tube Fiber Thread 250 Micron Fibers Steel Armor Ripcord for Jacket Access (2) Central Tube Non-Armored All-Dielectric Cable (36 Fiber All-Dielectric Version Shown) Rigid RSM (2) PE Outer Jacket Water-Blocking Tape Gel 6.0 mm Buffer Tube Fiber Threads 250 Micron Fibers Ripcord for Jacket Access (2) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression (Dielectric) 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Compression (Armored) 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +70 (+140 C) FOTP-81; IEC 60794-102, Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F37
Indoor/Outdoor Central Tube Cables Riser-Rated For Indoor/Outdoor Applications that Require a Riser Rating All meet critical NEC/CEC riser (OFNR) safety standards eliminating the need for splice point at building entrance Arid-Core water blocking technology helps protect fibers from moisture Standard color-coding on fibers helps ease installation Robust constructions offer excellent protection of fibers Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km Single Jacket 2-24 Fibers, 4mm Tube R-XXX-CN-XY-F12BK 2 0.40/10.1 5.9/15.1 4.0/10.1 607/2700 180/800 87 129 Indoor/Outdoor Central Tube Cable (24 Fiber Version Shown) Rigid RSM (2) PVC Outer Jacket Flexible Strength Elements Gel 4.0mm Buffer Tube 250 Micron Fibers Fiber Threads Ripcord for Jacket Access (2) Flame Test Specifications Flame Test Listing NEC Type OFNR (ETL) and c(etl) Flame Test Standard UL-1666 Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Strain See long & short tensile loads FOTP-33; IEC 60794-1-2; Sec. 5 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105 F38
Outside Plant Drop Cable Armored Design For Buried/Underground/Aerial Applications Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Small, lightweight cable increases ease of installation, routing and termination (no preferential bend) Cost effective, low fiber count cable for outside plant applications Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Subunits Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Armored 1-12 Fibers O-XXX-DA-XY-F12NS 1 0.32/8.1 4.8/12.2 3.2/8.1 300/1334 90/400 47 70 Singlemode/Multimode O-XXX-DA-CM-F12NS/AAaaa/BBbbb Composite (4-12 Fibers) Refer to above specifications. *This design is also available with a ripcord for applications where mid-span access is important (O-XXX-DA-XY-F12NS/BP) 8F Bend Insensitive, Singlemode Fiber* *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter Drop Armored Cable (12 fiber version shown) MDPE Outer Jacket Steel Armor Fiberglass Strength Elements 3.0mm Buffer Tube Aramid Strength Elements Gel 250 Micron Fibers Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-110-717-2002 RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed F39
Outside Plant Drop Cable All-Dielectric Design For Buried/Underground/Aerial Applications Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Small, lightweight cable increases ease of installation, routing and termination Cost effective, low fiber count cable for outside plant applications An outstanding choice when space is at a premium Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km All-Dielectric 1-12 Fibers O-XXX-DN-XY-F12NS 1 0.34/8.7 5.1/13.0 3.4/8.7 300/1334 90/400 46 69 Singlemode/Multimode Composite (4-12 Fibers) O-XXX-DN-CM-F12NS/AAaaa/BBbbb Refer to above specifications. 8F Bend-Insensitive, Singlemode Fiber* Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter All-Dielectric Drop Cable (12 fiber version shown) PE Outer Jacket Rigid RSM (2) Strength Elements 3.0 mm Buffer Tube Gel 250 Micron Fibers Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-110-717-2002 F40
Self-Support Non-Armor Figure-8 Outdoor Drop Cable 1-6 Fiber Arid-Core Construction For Aerial Applications Cost effective, low fiber count cable for outside plant applications Figure-8 cable designed for extended span capability Small, very flexible cable allowing for increased ease of installation, routing and termination The legs can be easily separated as needed Fiber leg was designed to function as a self-sufficient cable once separated from the messenger Product Type/ Catalog Diameter Cable Diameter Minimum Bend Radius Max Tensile Load Weight Fiber Count Number Over Messenger Height Over Fiber Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/cm inch/cm Lbs/N Lbs/N kft km Figure-8 Drop 1-6 Fibers M-XXX-MN-XY-FZZNS/ 0.17/4.3 0.42/10.7 0.20/5.1 3.0/7.7 2.0/5.1 300/1334 90/400 52 77 25G/109 8F Bend-Insensitive, Singlemode Fiber* Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter Figure-8 Drop Cable (6 fiber version shown) Low Density Polyethylene Outer Jacket 0.109 Solid Steel Messenger Strength Elements 2.5 mm Gel Filled Buffer Tube 250 Micron Fibers Rigid Strength Elements Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-110-717-2002 RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed F41
Outside Plant Self-Supporting Figure-8 Drop Cable 1-12 Fiber Arid-Core Construction For Aerial Applications Small, lightweight cable allowing for increased ease of installation, routing and termination Cost effective, low fiber count cable for outside plant applications Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Solid steel messenger member for simplified aerial applications Flexible design allows ease of routing and placement Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Diameter Cable Diameter Minimum Bend Radius Max Tensile Load Weight Fiber Count Number Over Messenger Height Over Fiber Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/cm inch/cm Lbs/N Lbs/N kft km Figure-8 Drop 1-12 Fibers M-XXX-DN-XY-FZZNS/ 0.13/3.4 0.45/11.5 0.27/6.8 4.0/10.2 2.7/6.8 300/1334 90/400 47 69 GSM/40T 8F Bend-Insensitive, Singlemode Fiber* Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter Figure-8 Drop Cable (2 fiber version shown) MDPE Outer Jacket 0.083 Messenger Wire Strength Elements Ripcord (1) 4.0 mm Buffer Tube Gel 250 Micron Fibers Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-110-717-2002 RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed F42
Outside Plant Self-Supporting Figure-8 Mini-Drop Cable 1-6 Fiber Arid-Core Construction Copper Clad Steel Messenger For Underground/Conduit Applications Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Small, lightweight cable increases ease of installation, routing and termination Cost effective, low fiber count cable for outside plant applications Solid steel messenger member can be used for toning Flexible design allows ease of routing and placement Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Product Type/ Catalog Diameter Cable Diameter Minimum Bend Radius Max Tensile Load Weight Fiber Count Number Over Messenger Height Over Fiber Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/cm inch/cm Lbs/N Lbs/N kft km Figure-8 Drop 1-12 Fibers M-XXX-MN-XY-F12NS/ 0.16/4.0 0.36/9.0 0.15/3.8 2.2/5.6 1.5/3.8 300/1334 90/400 26 39 CCS 8F Bend-Insensitive, Singlemode Fiber* Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F, a minimum bend radius of 5X the cable diameter Figure-8 Mini-Drop Cable (6 fiber version shown) Linear Low Density Polyethylene Outer Jacket Solid Steel Messenger 2.5mm Gel Filled Buffer Tube 250 Micron Fibers Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-110-717-2002 RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed F43
Outside Plant All-Dielectric Flat Drop Cable 1-12 Fiber Arid-Core Construction Aerial Self-Support or Direct Burial For Aerial Applications All dielectric cable design, which requires no bonding or grounding Compatible with industry standard hanging hardware Cost effective, low fiber count cable for outside plant applications Small, lightweight cable increases ease of installation, routing and termination Product Type/ Catalog Cable Outer Cable Minimum Bend Radius Max. Tensile Window Weight Fiber Count Number Diameter Height Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/cm inch/cm lbs/n lbs/n kft km All-Dielectric Flat Drop 1-12 Fibers O-XXX-DF-XY-F12NS 0.32/8.2 0.18/4.5 4.8/12.3 3.2/8.1 300/1334 90/400 28 42 Figure-8 Mini-Drop Cable (12 fiber version shown) MDPE Outer Jacket GRP Rods 2.0mm Buffer Tube 250 Micron Fibers Ripcords (2) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-110-717-2002 RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed F44
Outside Plant All-Dielectric Flat Drop Cable 1-12 Fiber Arid-Core Construction Aerial Self-Support For Underground/Conduit Applications Incorporated tone wire designed for tone locating when digging Cost effective, low fiber count cable for outside plant applications Small, lightweight cable increases ease of installation, routing and termination Tone wire can be easily separated as needed Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Product Type/ Catalog Cable Outer Cable Msg. Jkt. Minimum Bend Radius Max. Tensile Window Weight Fiber Count Number Diameter Height Outer Dia. Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/mm inch/cm inch/cm lbs/n kft km All-Dielectric Flat Drop 1-12 Fibers O-XXX-DF-HY-F12NS/ 0.40/10.2 0.18/4.5 0.08/2.0 6.0/15.3 3.2/8.1 300/1334 90/400 38 57 XYXXX/1x24AWG Figure-8 Mini-Drop Cable (12 fiber version shown) 24-awg Copper Conductor MDPE Outer Jacket GRP Rods 2.0mm Buffer Tube 250 Micron Fibers Ripcords (2) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-110-717-2002 RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed F45
LSZH Indoor/Outdoor Cable Non-Armored, All-Dielectric For Indoor/Outdoor Drop Applications that Require a LSZH Rating Black jackets are UV-stable for outdoor use yet meet critical NEC type safety standards OFNR-LS (ETL) and C(ETL) Also meets many international flame ratings such as IEC 60332-1, IEC 60332-3, IEC 61034-02, IEC 60754-1, IEC 60754-2 and NES 713 Riser rating eliminates splice points at the building entrance Arid-Core water blocking technology helps protect fibers from moisture Low-Smoke Zero-Halogen (LSZH) gives added protection to building occupants and equipment Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km Single Jacket 1-12 Fibers Z-XXX-DN-XY-F12BK/ 1 0.24/6.1 3.6/9.1 2.4/6.1 300/1334 90/400 30 44 20G Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km Single Jacket 1-24 Fibers Z-XXX-DN-XY-F12BK 2 0.33/8.3 4.9/12.5 3.3/8.3 300/1334 90/400 48 72 LSZH All-Dielectric Indoor/Outdoor Cable (12 Fiber, 4.0 mm Tube Version Shown) FRPE Outer Jacket Fiberglass Strength Elements 4.0 mm Gel Filled Buffer Tube 250 Micron Fibers Ripcord Flame Test Specifications Flame Test Listing NEC Type OFNR-LS (ETL) and c(etl) Flame Test Standard UL-1666, UL-1685, IEC 60332-3, IEC 61034-2, IEC 60754-2, IEEE 383 Installation Temperature -4 to +158 F (-20 to +70 C) Operating Temperature -4 to +158 F (-20 to +70 C) Storage Temperature -4 to +167 F (-20 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze +28 F (-2 C) FOTP-98 Drip +140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 Heat Age -4 to +185 F (-20 to +85 C) N/A Low High Bend -4 to +140 F (-20 to +60 C) FOTP-28; IEC 60794-1-2; Sec. 28 Temperature Cycle -4 to +158 F (-20 to +70 C) 24 Hours ANSI/ICEA S-110-717-2002 F46
ConQuest Toneable Conduit TM Installed with Central Tube Fiber Optic Products Fiber In ConQuest Toneable Conduit Cuts Installation Effort and Costs High strength 18 gauge copper clad steel tone wire saves installation dollars Moisture resistant polymer coated tone wire accurately detectable over various depths and lengths Tone wire embedded in the wall of the HDPE conduit results in easy wire removal Internally reinforced HDPE wall works with standard conduit connections Cable Type/ Fiber Part Number & Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count Conduit Description Weight (kft) Conduit OD Thicknesses SDR 11 SDR 13.5 SCH 40 Central Tube O-XXX-CN-XY-F12NS 0.40 1 SDR 11 or 13.5 265 230 Dielectric Specify Conduit OD, 63 lbs. 1 1 / 4 SDR 11 or 13.5 381 326 2-24 Fibers Wall Thickness and Color 1 1 / 2 SDR 11 or 13.5 477 405 2 SDR 13.5 or SCH 40 593 533 Central Tube O-XXX-CN-XY-F12NS 0.48 1 SDR 11 or 13.5 273 238 Dielectric Specify Conduit OD, 86 lbs. 1 1 / 4 SDR 11 or 13.5 389 334 26-48 Fibers Wall Thickness and Color 1 1 /2 SDR 11 or 13.5 485 413 2 SDR 13.5 or SCH 40 601 541 Central Tube O-XXX-CN-XY-F12NS 0.55 1 SDR 11 or 13.5 291 256 Dielectric Specify Conduit OD, 110 lbs. 1 1 / 4 SDR 11 or 13.5 407 352 50-96 Fibers Wall Thickness and Color 1 1 / 2 SDR 11 or 13.5 503 431 2 SDR 13.5 or SCH 40 619 559 Other cables and wall sizes may be available upon request. For more information, please see the Conduit section of this catalog. * Weight does not include reel. Central Tube Fiber-In-Conduit (24 Fiber Construction in Toneable Conduit Shown) Copper Clad Steel Tone Wire High-Grade Polyethylene Conduit Silicon-Based Lubricant Central Tube Cable F47
ConQuest Toneable Conduit TM Pre-Installed with CommScope Dry Loose Tube Fiber Optic Cable Fiber-In-Conduit All of CommScope s fiber cables can be pre-installed in conduit, including the gel free, Dry Loose Tube cable. Available in five different diameters - 3 /4, 1, 1 1 /4, 1 1 /2 and 2 and three different wall thicknesses - SDR 11, SDR 13.5 and SCH 40. For more information or specifications on Fiber Optic cables, please visit our website at www.commscope.com. Cable Type/ Fiber Part Number & Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count Conduit Description Weight (kft) Conduit OD Thicknesses SDR 11 SDR 13.5 SCH 40 Dry (gel free) D-XXX-LN-XY-F12NS 0.40 3 /4 SDR 11 or 13.5 175 156 Loose Tube Specify Conduit OD, Wall 45 lbs. 1 SDR 11 or 13.5 249 214 Dielectric Thickness and Color 1 1 / 4 SDR 11 or 13.5 355 264 2-60 Fibers 1 1 / 2 SDR 11 or 13.5 461 389 2 SDR 13.5 or SCH 40 577 517 Dry (gel free) D-XXX-LN-XY-F12NS 0.42 3 / 4 SDR 11 or 13.5 179 160 Loose Tube Specify Conduit OD, Wall 49 lbs. 1 SDR 11 or 13.5 253 218 Dielectric Thickness and Color 1 1 / 4 SDR 11 or 13.5 369 314 62-72 Fibers 1 1 / 2 SDR 11 or 13.5 465 393 2 SDR 13.5 or SCH 40 581 521 Dry (gel free) D-XXX-LN-XY-F12NS 0.48 3 /4 SDR 11 or 13.5 194 175 Loose Tube Specify Conduit OD, Wall 64 lbs. 1 SDR 11 or 13.5 269 233 Dielectric Thickness and Color 1 1 / 4 SDR 11 or 13.5 384 329 74-96 Fibers 1 1 / 2 SDR 11 or 13.5 480 408 2 SDR 13.5 or SCH 40 596 536 Dry (gel free) D-XXX-LN-XY-F12NS 0.54 1 SDR 11 or 13.5 287 252 Loose Tube Specify Conduit OD, Wall 83 lbs. 1 1 / 4 SDR 11 or 13.5 403 348 Dielectric Thickness and Color 1 1 / 2 SDR 11 or 13.5 499 427 98-120 Fibers 2 SDR 13.5 or SCH 40 615 555 Dry (gel free) D-XXX-LN-XY-F12NS 0.62 1 1 / 4 SDR 11 or 13.5 427 372 Loose Tube Specify Conduit OD, Wall 107 lbs. 1 1 / 2 SDR 11 or 13.5 523 451 Dielectric Thickness and Color 2 SDR 13.5 or SCH 40 639 579 122-144 Fibers Dry (gel free) D-XXX-LN-XY-F12NS 0.62 1 1 /4 SDR 11 or 13.5 410 355 Loose Tube Specify Conduit OD, Wall 90 lbs. 1 1 / 2 SDR 11 or 13.5 506 434 Dielectric Thickness and Color 2 SDR 13.5 or SCH 40 622 562 146-216 Fibers Dry (gel free) D-XXX-LN-XY-F12NS 0.72 1 1 /4 SDR 11 or 13.5 442 387 Loose Tube Specify Conduit OD, Wall 122 lbs. 1 1 /2 SDR 11 or 13.5 538 466 Dielectric Thickness and Color 2 SDR 13.5 or SCH 40 654 594 218-288 Fibers Other cables and wall sizes may be available upon request. * Weight does not include reel. Dry Loose Tube Fiber-In-Conduit (72 Fiber Construction in Toneable Conduit Shown) Copper Clad Steel Tone Wire High-Grade Polyethylene Conduit Silicon-Based Lubricant Dry Loose Tube Cable * Weight does not include reel. Other cables and wall sizes may be available upon request. F48
ConQuest Toneable Conduit TM Pre-Installed with CommScope Arid-Core Fiber Optic Cable Fiber-In-ConQuest Toneable Conduit Cuts Installation Effort and Costs All of CommScope s fiber cables can be pre-installed in conduit, including the Arid-Core Loose Tube cable. Available in five different diameters - 3 /4, 1, 1 1 /4, 1 1 /2 and 2 and three different wall thicknesses - SDR 11, SDR 13.5 and SCH 40. For more information or specifications on Fiber Optic cables, please visit our website at www.commscope.com. Cable Type/ Fiber Part Number & Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count Conduit Description Weight (kft) Conduit OD Thicknesses SDR 11 SDR 13.5 SCH 40 Arid-Core O-XXX-LN-XY-F12NS/25T 0.40 3 /4 SDR 11 or 13.5 178 159 Loose Tube Specify Conduit OD, Wall 48 lbs. 1 SDR 11 or 13.5 252 217 Dielectric Thickness and Color 1 1 / 4 SDR 11 or 13.5 368 313 2-60 Fibers 1 1 / 2 SDR 11 or 13.5 464 392 2 SDR 13.5 or SCH 40 580 520 Arid-Core O-XXX-LN-XY-F12NS/25T 0.42 3 /4 SDR 11 or 13.5 182 163 Loose Tube Specify Conduit OD, Wall 52 lbs. 1 SDR 11 or 13.5 256 221 Dielectric Thickness and Color 1 1 / 4 SDR 11 or 13.5 372 327 62-72 Fibers 1 1 / 2 SDR 11 or 13.5 468 396 2 SDR 13.5 or SCH 40 584 524 Arid-Core O-XXX-LN-XY-F12NS/25T 0.48 3 /4 SDR 11 or 1.35 200 180 Loose Tube Specify Conduit OD, Wall 69 lbs. 1 SDR 11 or 13.5 273 268 Dielectric Thickness and Color 1 1 / 4 SDR 11 or 13.5 389 334 74-96 Fibers 1 1 / 2 SDR 11 or 13.5 485 413 2 SDR 13.5 or SCH 40 578 518 Arid-Core O-XXX-LN-XY-F12NS/25T 0.54 1 SDR 11 or 13.5 293 258 Loose Tube Specify Conduit OD, Wall 89 lbs. 1 1 / 4 SDR 11 or 13.5 409 382 Dielectric Thickness and Color 1 1 / 2 SDR 11 or 13.5 505 461 98-120 Fibers 2 SDR 13.5 or SCH 40 649 561 Arid-Core O-XXX-LN-XY-F12NS/25T 0.62 1 1 / 4 SDR 11 or 13.5 434 379 Loose Tube Specify Conduit OD, Wall 114 lbs. 1 1 / 2 SDR 11 or 13.5 530 458 Dielectric Thickness and Color 2 SDR 13.5 or SCH 40 646 586 122-144 Fibers Arid-Core O-XXX-LN-XY-F12NS/25T 0.62 1 1 / 4 SDR 11 or 13.5 422 367 Loose Tube Specify Conduit OD, Wall 102 lbs. 1 1 / 2 SDR 11 or 13.5 518 446 Dielectric Thickness and Color 2 SDR 13.5 or SCH 40 634 574 146-216 Fibers Arid-Core O-XXX-LN-XY-F12NS/25T 0.72 1 1 / 4 SDR11 or 13.5 458 403 Loose Tube Specify Conduit OD, Wall 138 lbs. 1 1 / 2 SDR 11 or 13.5 554 482 Dielectric Thickness and Color 2 SDR 13.5 or SCH 40 670 610 218-288 Fibers Other cables and wall sizes may be available upon request. * Weight does not include reel. Arid-Core Loose Tube Fiber-In-Conduit (72 Fiber Construction in Toneable Conduit Shown) Copper Clad Steel Tone Wire High-Grade Polyethylene Conduit Silicon-Based Lubricant Arid-Core Loose Tube Cable F49 * Weight does not include reel. Other cables and wall sizes may be available upon request.
ConQuest Conduit Pre-Installed with CommScope Fiber Drop Cable Fiber-In-Conduit All of CommScope s fiber cables can be pre-installed in conduit, including the Fiber Drop cables. Available in 1 / 2 or 3 / 4 and two different wall thicknesses - SDR 11 or SDR 13.5. For more information or specifications on Fiber Optic cables, please visit our website at www.commscope.com. Figure-8 Fiber Drop Cable In Conduit Cable Type/ Catalog Number Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count (Description) Weight (kft) Conduit OD Thickness SDR 11 SDR 13.5 Fiber Drop M-XXX-MN-XY-FZZNS/CCS 0.16 x 0.31 ½ SDR 11 or 13.5 112 98 Messengered (Solid Steel Construction) 27 lbs. ¾ 157 138 1-6 Fibers Specify Conduit OD, Wall Thickness and Color NOTE: The solid or stranded steel messengers can be used to pull the cable during installation, and for locating after burial. All-Dielectric Flat Drop Cable In Conduit Cable Type/ Catalog Number Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count (Description) Weight (kft) Conduit OD Thickness SDR 11 SDR 13.5 Flat Drop O-XXX-DF-XY-FZZNS 0.18 x 0.32 ½ SDR 11 or 13.5 115 101 1-12 Fibers Specify Conduit OD, 30 lbs. ¾ 160 141 Wall Thickness and Color *Other size conduits may be available upon request. * Weight does not include reel. Toneable Flat Drop Cable In Conduit Cable Type/ Catalog Number Cable OD & Available Available Wall Weight (lb/kft)* Fiber Count (Description) Weight (kft) Conduit OD Thickness SDR 11 SDR 13.5 Toneable Flat Drop 1-12 Fibers O-XXX-DF-HY-FZZNS/XYZZZ/ 0.18 x 0.40 ¾ SDR 11 or 13.5 168 149 1X12AWG 38 lbs. 1 SDR 11 or 13.6 242 207 Specify Conduit OD, Wall Thickness and Color *Other size conduits may be available upon request. * Weight does not include reel. 5M LaserCore Solid Steel Messengered Fiber Drop In ConQuest Conduit (6 Fiber Construction Shown) High-Grade Polyethylene Conduit Silicon-Based Lubricant All-Dielectric Flat Drop Cable in ConQuest Conduit (6 Fiber Construction Shown) High-Grade Polyethylene Conduit Silicon-Based Lubricant Toneable Flat Drop Cable in ConQuest Conduit (6 Fiber Construction Shown) High-Grade Polyethylene Conduit Silicon-Based Lubricant Messengered Fiber Drop Cable Flat Drop Cable Toneable Flat Drop Cable Drawings are not to scale Specifications are subject to change without notice F50
CommScope Hybrid Cable Fiber/6 Series Drop Cable (BrightWire ) Features & Benefits The BrightWire drop cable leg is designed to carry video The optical leg is designed to carry voice and data Only a single installation is required Small, very flexible cable allowing for increased ease of installation, routing and termination The legs can be easily separated as needed Product Type/ Catalog Cable Outer Cable Component Sub Minimum Bend Radius Max. Tensile Window Weight Fiber Count Number Diameter Height Jacket OD Units Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm inch/cm inch/cm lbs/n lbs/n kft km 1-12 Fibers O-XXX-DN-HY-F12NS/ 0.26/6.6 0.61/15.4 0.30/7.5 1 3.9/9.9 2.6/6.6 300/1334 90/400 78 116 40G/XYXXX/F6SSBW Jacket Color: Black Medium Density Polyethylene Arid-Core Construction Fiber Coax Hybrid Cable (12 Fiber Version Shown) LDPE Jacket BrightWire Aluminum Braid Anti-Corrosion Tape BrightWire Aluminum Braid Anti-Corrosion Tape 18 AWG Copper Clad Steel Dielectric Fiberglass Strength Elements 4.0mm Buffer Tube Gel 250 Micron Fibers Ripcord Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-110-717-2002 F51
CommScope Self-Support Figure-8 Hybrid Cable Fiber/6 Series Drop Cable (BrightWire ) Features & Benefits The BrightWire drop cable leg is designed to carry video The optical leg is designed to carry voice and data Only a single installation is required Small, very flexible cable allowing for increased ease of installation, routing and termination The legs can be easily separated as needed Product Type/ Catalog Cable Outer Cable Messenger Copper Minimum Bend Radius Max. Tensile Window Weight Fiber Count Number Diameter Height Jacket OD Comp./ Loaded Unloaded Short Term Long Term lbs/ kg/ inch/mm inch/mm inch/mm Buffer Tubes inch/cm inch/cm lbs/n lbs/n kft km 1-12 Fibers M-XXX-DN-HY-F12NS/ 0.26/6.6 0.79/20.1 0.13/3.4 1/1 3.9/9.9 2.6/6.6 300/1334 90/400 101 150 XYXXX/40T/F6SSBW/ GSM Jacket Color: Black Linear Low Density Polyethylene Arid-Core Construction Self-Supporting Hybrid Cable (12 Fiber Version with Messenger Shown) Galvanized Steel Messenger LDPE Jacket BrightWire Aluminum Braid Anti-Corrosion Tape BrightWire Aluminum Braid Anti-Corrosion Tape 0.0403 CU/Steel Dielectric 4.0mm Buffer Tube Strength Elements Gel Ripcord (1) 250 Micron Fibers Installation Temperature Operating Temperature Storage Temperature -22 to +158 F (-30 to +70 C) -40 to +158 F (-40 to +70 C) -40 to +167 F (-40 to +75 C) Compression 57 lbf/in (10 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-110-717-2002 F52
Hybrid Single Jacket Outdoor Cable Armored Features & Benefits Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection Designed for tone locating when digging and for communications Used for powering optoelectrical equipment down the line Provides line fault detection and location Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count/Pair Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km 2-48 Fibers O-XXX-LA-HY-FZZNS/ 1 Pair XYXXX/1X22UTP 5 0.50/12.7 7.5/19.0 5.0/12.7 607/2700 180/800 95 141 50-60 Fibers O-XXX-LA-HY-FZZNS/ 6 0.54/13.7 8.1/20.5 5.4/13.7 607/2700 180/800 110 164 1 Pair XYXXX/1X22UTP 62-84 Fibers O-XXX-LA-HY-FZZNS/ 8 0.62/15.7 9.3/23.6 6.2/15.7 607/2700 180/800 141 210 1 Pair XYXXX/1X22UTP 86-108 Fibers O-XXX-LA-HY-FZZNS/ 10 0.70/17.8 10.5/26.7 7.0/17.8 607/2700 180/800 174 259 1 Pair XYXXX/1X22UTP 110-132 Fibers O-XXX-LA-HY-FZZNS/ 12 0.78/19.9 11.7/29.8 7.8/19.9 607/2700 180/800 214 318 1 Pair XYXXX/1X22UTP 134-204 Fibers O-XXX-LA-HY-FZZNS/ 18 0.78/19.9 11.7/29.8 7.8/19.9 607/2700 180/800 199 296 1 Pair XYXXX/1X22UTP 206-276 Fibers O-XXX-LA-HY-FZZNS/ 1 Pair XYXXX/1X22UTP 24 0.90/22.9 13.5/34.3 9.0/22.9 607/2700 180/800 258 383 Copper Twisted Pairs are identified with standard color coding: 1/White/Blue, 2/White/Orange, 3/White/Green, 4/White/Brown, 5/White/Grey Hybrid Single Jacket Armored Cable (108 Fiber Version Shown) PE Outer Jacket 22 AWG UTP (1) Water Swellable Tape Steel Tape Armoring Strength Elements Dielectric Strength Member Central Member Upjacket 3.0mm Gel Filled Buffer Tubes 250 Micron Fibers Ripcord (2) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F53
Hybrid Single Jacket Outdoor Cable All-Dielectric Features & Benefits Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Designed for communications and tone locating when digging Used for powering optoelectrical equipment down the line Provides line fault detection and location Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count/Pair Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km 2-48 Fibers 1 Pair O-XXX-LN-HY-FZZNS/ 5 0.44/11.3 6.7/16.9 4.4/11.3 607/2700 180/800 58 87 XYXXX/1X22UTP 50-60 Fibers O-XXX-LN-HY-FZZNS/ 6 0.48/12.3 7.3/18.4 4.8/12.3 607/2700 180/800 71 106 1 Pair XYXXX/1X22UTP 62-84 Fibers O-XXX-LN-HY-FZZNS/ 1 Pair XYXXX/1X22UTP 86-108 Fibers O-XXX-LN-HY-FZZNS/ 1 Pair XYXXX/1X22UTP 110-132 Fibers O-XXX-LN-HY-FZZNS/ 1 Pair XYXXX/1X22UTP 134-204 Fibers O-XXX-LN-HY-FZZNS/ 1 Pair XYXXX/1X22UTP 206-276 Fibers O-XXX-LN-HY-FZZNS/ 1 Pair XYXXX/1X22UTP 8 0.56/14.3 8.5/21.5 5.6/14.3 607/2700 180/800 96 143 10 0.65/16.4 9.7/24.6 6.5/16.4 607/2700 180/800 123 184 12 0.73/18.5 10.9/27.8 7.3/18.5 607/2700 180/800 155 231 18 0.73/18.5 10.9/27.8 7.3/18.5 607/2700 180/800 140 209 24 0.85/21.5 12.7/32.2 8.5/21.5 607/2700 180/800 191 284 Copper Twisted Pairs are identified with standard color coding: 1/White/Blue, 2/White/Orange, 3/White/Green, 4/White/Brown, 5/White/Grey Hybrid Single Jacket All-Dielectric Cable (108 Fiber Version Shown) PE Outer Jacket 22 AWG UTP (1) Water Swellable Tape Strength Elements Dielectric Strength Member Central Member Upjacket 3.0mm Gel Filled Buffer Tubes 250 Micron Fibers Ripcord Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F54
Hybrid Single Jacket Outdoor Cable + Conductor Armored Features & Benefits Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection Designed for tone locating when digging Provides line fault detection and location Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count/Conductor Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km 2-48 Fibers 1-4 Conductors O-XXX-LA-HY-FZZNS/ 5 0.50/12.7 7.5/19.0 5.0/12.7 607/2700 180/800 113 168 XYXXX/NX12AWG 50-60 Fibers O-XXX-LA-HY-FZZNS/ 6 0.54/13.7 8.1/20.5 5.4/13.7 607/2700 180/800 128 191 1-4 Conductors XYXXX/NX12AWG 62-84 Fibers O-XXX-LA-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG 86-108 Fibers O-XXX-LA-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG 110-132 Fibers O-XXX-LA-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG 134-204 Fibers O-XXX-LA-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG 8 0.62/15.7 9.3/23.6 6.2/15.7 607/2700 180/800 160 238 10 0.70/17.8 10.5/26.7 7.0/17.8 607/2700 180/800 193 287 12 0.78/19.9 11.7/29.8 7.8/19.9 607/2700 180/800 232 346 18 0.78/19.9 11.7/29.8 7.8/19.9 607/2700 180/800 217 323 206-276 Fibers O-XXX-LA-HY-FZZNS/ 24 0.90/22.9 13.5/34.3 9.0/22.9 607/2700 180/800 276 411 1-4 Conductors XYXXX/NX12AWG Copper Conductors Color Coding: Specified by customer F55 Hybrid Single Jacket All-Dielectric Cable (108 Fiber Version Shown) PE Outer Jacket Steel Tape Armoring Water Swellable Tape Strength Elements 3.0mm Gel Filled Buffer Tubes Dielectric Strength Member 12 AWG Copper Conductor White (1) 250 Micron Fibers Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 250 lbf/in (44 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Hybrid Single Jacket Outdoor Cable + Conductor All-Dielectric Features & Benefits Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Designed for tone locating when digging Provides line fault detection and location Outer Minimum Bend Radius Maximum Tensile Load Weight Product Type/ Catalog Sub Diameter Loaded Unloaded lbs/meters lbs/ kg/ Fiber Count/Conductor Count Number Units inch/mm inch/cm inch/cm Short Term Long Term kft km 2-48 Fibers 1-4 Conductors O-XXX-LN-HY-FZZNS/ 5 0.44/11.3 6.7/16.9 4.4/11.3 607/2700 180/800 76 114 XYXXX/NX12AWG 50-60 Fibers O-XXX-LN-HY-FZZNS/ 6 0.48/12.3 7.3/18.4 4.8/12.3 607/2700 180/800 89 133 1-4 Conductors XYXXX/NX12AWG 62-84 Fibers O-XXX-LN-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG 86-108 Fibers O-XXX-LN-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG 110-132 Fibers O-XXX-LN-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG 134-204 Fibers O-XXX-LN-HY-FZZNS/ 1-4 Conductors XYXXX/NX12AWG 8 0.56/14.3 8.5/21.5 5.6/14.3 607/2700 180/800 114 170 10 0.65/16.4 9.7/24.6 6.5/16.4 607/2700 180/800 142 211 12 0.73/18.5 10.9/27.8 7.3/18.5 607/2700 180/800 174 259 18 0.73/18.5 10.9/27.8 7.3/18.5 607/2700 180/800 159 236 206-276 Fibers O-XXX-LN-HY-FZZNS/ 24 0.85/21.5 12.7/32.2 8.5/21.5 607/2700 180/800 210 312 1-4 Conductors XYXXX/NX12AWG Copper Conductors are identified with a standard color coding: 1/Red, 2/Black, 3/Green, 4/Brown Hybrid Single Jacket All-Dielectric Cable (108 Fiber Version Shown) PE Outer Jacket Water Swellable Tape Strength Elements 3.0mm Gel Filled Buffer Tubes Dielectric Strength Member 12 AWG Copper Conductor White (1) 250 Micron Fibers Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105 F56
Single Jacket Single Armor Outdoor Cable + Conductor Armored and Non-Armored, All Dielectric Features & Benefits Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Designed for tone locating when digging Provides line fault detection and location Product Type/ Catalog Outer Diameter Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Number Subunits inch/mm Loaded Unloaded Short Term Long Term lbs/ kg/ inch/cm inch/cm lbs/newtons lbs/newtons kft km Armored 278-408 Fibers O-XXX-LA-HY-F24NS/ 18 0.90/22.9 13.5/34.3 9.0/22.9 607/2700 180/800 261 389 1-4 Conductors XYXXX/NX12AWG 410-552 Fibers O-XXX-LA-HY-F24NS/ 24 1.03/26.2 15.4/39.2 10.3/26.2 607/2700 180/800 337 502 1-4 Conductors XYXXX/NX12AWG All-Dielectric 278-408 Fibers O-XXX-LN-HY-F24NS/ 18 0.84/21.5 12.7/32.2 8.5/21.5 607/2700 180/800 194 289 1-4 Conductors XYXXX/NX12AWG 410-552 Fibers O-XXX-LN-HY-F24NS/ 24 0.97/24.8 14.6/39.2 9.8/24.8 607/2700 180/800 261 388 1-4 Conductors XYXXX/NX12AWG *Weights were calculated using a single 12 AWG conductor. Providing number of conductors, custom tables are available upon request. Buffer Tubes 13-23 repeat color sequence with tracer stripe Copper Conductors Color Coding: Specified by customer F57 Single Jacket Single Armor Outdoor Cable + Conductor (552 Fiber Armored,1 x 12 AWG Version Shown) 12 AWG Copper Conductor (1) PE Outer Jacket Steel Tape Armor Strength Elements Water Swellable Tape 3.5mm Gel Filled Buffer Tubes 250 Micron Fibers Dielectric Strength Member Ripcord (1) Installation Temperature -22 to +158 F (-30 to +70 C) Operating Temperature -40 to +158 F (-40 to +70 C) Storage Temperature -40 to +167 F (-40 to +75 C) Compression 125 lbf/in (22 N/mm) FOTP-41; IEC 60794-1-2; Sec. 7 Cable Freeze 28 F (-2 C) FOTP-98 Drip 140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105
Indoor/Outdoor LSZH Distribution Cable Low-Smoke Zero-Halogen, Riser-Rated LSZH Construction Permits Riser Applications as Well Black jackets are UV-stable for outdoor use yet meet critical NEC/CEC riser (OFNR and OFN-LS) safety standards Riser rating eliminates splice points at the building entrance Arid-Core water blocking technology helps protect fibers from moisture Low-Smoke Zero-Halogen (LSZH) gives added protection to building occupants and equipment Tight buffered construction reduces installation cost Fiber Catalog Outer Minimum Bend Radius Maximum Tensile Load Weight Count Number Diameter Loaded Unloaded Short term Long term lbs/kft kg/km 2 Fibers (no central member) Z-ØØ2-DS-XY-FSUBK 0.15/3.8 3.0/7.7 1.5/3.8 225/1001 68/300 7.8 11.6 4 Fibers (no central member) Z-ØØ4-DS-XY-FSUBK 0.20/5.1 4.0/10.1 2.0/5.1 300/1335 90/400 13.5 20.1 6 Fibers Z-ØØ6-DS-XY-FSUBK 0.22/5.5 4.4/11.1 2.2/5.5 300/1335 90/400 17.6 26.3 8 Fibers Z-ØØ8-DS-XY-FSUBK 0.25/6.3 5.0/12.6 2.5/6.3 300/1335 90/400 23.7 35.3 12 Fibers Z-Ø12-DS-XY-FSUBK 0.28/7.2 5.6/14.2 2.8/7.1 400/1780 120/534 32.6 48.6 18 Fibers Z-Ø18-DS-XY-FSUBK 0.31/7.9 6.2/15.7 3.1/7.9 300/1335 90/400 37.0 55.0 24 Fibers Z-Ø24-DS-XY-FSUBK 0.34/8.7 6.8/17.4 3.4/8.7 300/1335 90/400 45.2 67.3 36 Fibers Z-Ø36-DS-XY-FMUBK 0.70/17.8 14.0/35.6 7.0/17.8 800/3560 240/1068 162.4 241.6 48 Fibers Z-Ø48-DS-XY-FMUBK 0.80/20.2 16.0/40.6 8.0/20.3 800/3560 240/1068 206.6 307.4 60 Fibers Z-Ø60-DS-XY-FMUBK 0.87/22.0 17.4/44.2 8.7/22.1 1000/4450 300/1335 260.7 387.9 72 Fibers Z-Ø72-DS-XY-FMUBK 0.95/24.1 19.0/48.2 9.5/24.1 1000/4450 300/1335 320.5 477.0 Singlemode/Multimode Z-ØØØ-DS-CM-FSUBK/AAaaa/BBbbb Custom design - sizes/specs will vary depending on fiber count Composite (4-72 Fibers) Z-ØØØ-DS-CM-FMUBK/AAaaa/BBbbb Tight Jacket Color: UV Stabilized Black LSZH Indoor/Outdoor Riser-Rated Distribution Cable (Multi-Unit) (72 Fiber Version Shown) Low-Smoke Zero-Halogen (LSZH) Outer Jacket Triathlon Subunit with Arid-Core Central Strength Member Water Blocking Tapes Ripcord 12 Fiber Unit (Single Unit) LSZH Jacket Aramid Yarn Central Strength Member 900 Micron Tight-Buffered 250 Micron Fiber Ripcord Water Blocking Thread Mechanical Properties Description Specification Test Method Operating Temperature -40 to 158 F (-40 to 70 C) FOTP-3 Installation Temperature -22 to 158 F (-30 to 70 C) N/A Storage Temperature -40 to 167 F (-40 to 75 C) N/A Crush Resistance Exceeds 126 lbf/in (22 N/mm) FOTP-41 Impact Resistance Exceeds 4.34 lb ft (5.88 N m) FOTP-25 Flexing Exceeds 100 cycles FOTP-104 Twist Bend Exceeds FOTP-85 CommScope Fiber Optic Premises cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. Water penetration performance meets the requirements of Telcordia GR-20-CORE, Issue 2. F58
Indoor/Outdoor LSZH Cordage Cable Low-Smoke Zero-Halogen, Riser-Rated LSZH Construction Permits Riser Applications as Well Black jackets are UV-stable for outdoor use yet meet critical NEC/CEC riser (OFNR and OFN-LS) safety standards Riser rating eliminates splice points at the building entrance Arid-Core water blocking technology helps protect fibers from moisture Low-Smoke Zero-Halogen gives added protection to building occupants and equipment Simplex and zipcord cables are available in a variety of sizes Designed for ease of handling and termination Cable Type/Unit Size Catalog Outer Minimum Bend Radius Maximum Tensile Load Weight Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./newtons kft km Simplex/1.6mm Z-ØØ1-SP-XY-F16BK 0.067/1.70 2.0/5.0 1.2/3.0 35/156 11/47 1.9 2.9 Simplex/2.5mm Z-ØØ1-SP-XY-F25BK 0.098/2.50 2.0/5.0 1.2/3.0 60/267 18/80 4.5 6.7 Simplex/2.9mm Z-ØØ1-SP-XY-F29BK 0.114/2.90 2.3/5.8 1.2/3.0 60/267 18/80 6.2 9.2 Zipcord/1.6mm Z-ØØ2-ZC-XY-F16BK 0.067 x 0.138/ 2.0/5.0 1.2/3.0 70/311 21/93 3.8 5.6 1.70 x 3.50 Zipcord/2.5mm Z-ØØ2-ZC-XY-F25BK 0.098 x 0.201/ 2.50 x 5.10 2.0/5.0 1.2/3.0 90/400 27/120 9.0 13.4 Zipcord/2.9mm Z-ØØ2-ZC-XY-F29BK 0.114 x 0.232/ 2.90 x 5.90 2.3/5.8 1.2/3.0 90/400 27/120 12.4 18.5 Interconnect/2.9mm Z-ØØ2-IC-XY-F29BK 0.114/2.90 2.3/5.8 1.2/3.0 70/311 21/93 5.0 7.4 Tight Buffer/Fiber Identification Colors: 1/Blue, 2/Orange Jacket Color: UV Stabilized Black Indoor/Outdoor LSZH Simplex Cable LSZH Riser Rated Outer Jacket Water Blocking System Aramid Yarn 900µm Tight Buffer 250µm Optical Fiber Indoor/Outdoor LSZH Zipcord Cable LSZH Riser Rated Outer Jacket Aramid Yarn Water Blocking System 900µm Tight Buffer 250µm Optical Fiber Indoor/Outdoor LSZH 2-Fiber Interconnect Cable LSZH Riser Rated Outer Jacket Aramid Yarn Water Blocking System 900µm Tight Buffer 250µm Optical Fibers Mechanical Properties Description Specification Test Method Operating Temperature -40 to 158 F (-40 to 70 C) FOTP-3 Installation Temperature -22 to 158 F (-30 to 70 C) N/A Storage Temperature -40 to 167 F (-40 to 75 C) N/A Crush Resistance Exceeds 57 lbf/in (10 N/mm) FOTP-41 Impact Resistance Exceeds 0.54 lbf ft (0.74 N m) FOTP-25 Flexing Exceeds 300 cycles FOTP-104 Twist Bend Exceeds FOTP-85 CommScope Fiber Optic Premise cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. Water penetration performance meets the requirements of Telcordia GR-20-CORE, Issue 2. F59
Premise Riser-Rated Distribution Cable For Indoor Applications that Require a Riser Rating Meets critical NEC/CEC riser (OFNR) safety standards Colored-Coded and color-coded fibers help ease installation Outer Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Catalog Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./newtons kft km 2 Fibers R-ØØ2-DS-XY-FSUZZ 0.16/4.1 3.2/8.1 1.6/4.1 225/1001 68/300 8.6 12.9 4 Fibers R-ØØ4-DS-XY-FSUZZ 0.19/4.8 3.8/9.5 1.9/4.8 300/1335 90/400 13.1 19.4 6 Fibers R-ØØ6-DS-XY-FSUZZ 0.20/5.1 4.1/10.3 2.0/5.1 300/1335 90/400 15.2 22.7 8 Fibers R-ØØ8-DS-XY-FSUZZ 0.22/5.5 4.3/11.0 2.2/5.5 300/1335 90/400 17.2 25.7 12 Fibers R-Ø12-DS-XY-FSUZZ 0.24/6.0 4.7/12.1 2.4/6.0 300/1335 90/400 21.7 32.2 18 Fibers R-Ø18-DS-XY-FSUZZ 0.30/7.7 6.0/15.4 3.0/7.7 300/1335 90/400 32.1 47.7 24 Fibers R-Ø24-DS-XY-FSUZZ 0.33/8.4 6.6/16.7 3.3/8.4 300/1335 90/400 37.9 56.4 36 Fibers (3 subunits) R-Ø36-DS-XY-FMUZZ 0.58/14.6 11.5/29.3 5.8/14.6 800/3560 240/1068 112.0 167.0 48 Fibers (4 subunits) R-Ø48-DS-XY-FMUZZ 0.63/16.1 12.7/32.2 6.3/16.1 800/3560 240/1068 143.0 212.0 60 Fibers (5 subunits) R-Ø6Ø-DS-XY-FMUZZ 0.71/18.0 14.2/36.1 7.1/18.0 1000/4450 300/1335 188.0 279.0 72 Fibers (6 subunits) R-Ø72-DS-XY-FMUZZ 0.79/20.0 15.8/40.1 7.9/20.0 1000/4450 300/1335 232.0 345.0 96 Fibers (8 subunits) R-Ø96-DS-XY-FMUZZ 0.93/23.7 18.7/47.5 9.3/23.7 1000/4450 300/1335 337.0 502.0 144 Fibers (12 subunits) R-144-DS-XY-FMUZZ 1.03/26.1 20.5/52.2 10.3/26.1 1000/4450 300/1335 350.0 522.0 Singlemode/Multimode R-XXX-DS-CM-FSUOR/AAaaa/BBbbb Composite (4-144 Fibers) R-XXX-DS-CM-FMUOR/AAaaa/BBbbb Custom design - sizes/specs will vary depending on fiber count Tight Buffer/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Subunits are color-coded in the same manner. Riser Distribution Cable (Multi-Unit) (72 and 12 Fiber Versions Shown) Riser Rated Outer Jacket Core Wrap Tape Central Strength Member 12 Fiber Subunit Ripcord 12 Fiber Unit (Single Unit) Riser Rated Outer Jacket Aramid Yarn 900 µm Tight Buffer 250 µm Optical Fiber Ripcord Mechanical Properties Description Specification Test Method Operating Temperature -4 to 158 F (-20 to 70 C) FOTP-3 Installation Temperature -4 to 158 F (-20 to 70 C) N/A Storage Temperature -40 to 158 F (-40 to 70 C) N/A Crush Resistance Exceeds 57 lbf/in (10N/mm) FOTP-41 Impact Resistance Exceeds 4.34 lb ft (5.88 N m) FOTP-25 Flexing Exceeds 100 cycles FOTP-104 Twist Bend Exceeds FOTP-85 CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. F60
Premise Riser-Rated Cordage Cable Several Constructions Available for a Variety of Applications For Indoor Applications that Require a Riser Rating Meets critical NEC/CEC riser (OFNR) safety standards Simplex and zipcord cables are available in a variety of sizes Designed for ease of handling and termination Cable Type/Unit Size Catalog Outer Minimum Bend Radius Maximum Tensile Load Weight Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./newtons kft km Simplex/1.6mm R-ØØ1-SP-XY-F16ZZ 0.067/1.70 2.0/5.0 1.2/3.0 35/156 11/47 1.8 2.7 Simplex/2.0mm R-ØØ1-SP-XY-F20ZZ 0.079/2.00 2.0/5.0 1.2/3.0 50/222 15/67 2.8 4.1 Simplex/2.5mm R-ØØ1-SP-XY-F25ZZ 0.098/2.50 2.0/5.0 1.2/3.0 60/267 18/80 4.2 6.3 Simplex/2.9mm R-ØØ1-SP-XY-F29ZZ 0.114/2.90 2.3/5.8 1.2/3.0 60/267 18/80 5.8 8.7 Zipcord/1.6mm R-ØØ2-ZC-XY-F16ZZ 0.067 x 0.138/ 2.0/5.0 1.2/3.0 70/311 21/93 3.7 5.5 1.70 x 3.50 Zipcord/2.0mm R-ØØ2-ZC-XY-F20ZZ 0.079 x 0.161/ 2.0/5.0 1.2/3.0 80/356 24/107 5.4 8.0 2.00 x 4.10 Zipcord/2.5mm R-ØØ2-ZC-XY-F25ZZ 0.098 x 0.201/ 2.0/5.0 1.2/3.0 90/400 27/120 8.5 12.6 2.50 x 5.10 Zipcord/2.9mm R-ØØ2-ZC-XY-F29ZZ 0.114 x 0.232/ 2.3/5.8 1.2/3.0 90/400 27/120 11.7 17.4 2.90 x 5.90 Interconnect /2.9mm R-ØØ2-IC-XY-F29ZZ 0.114/2.90 2.3/5.8 1.2/3.0 70/311 21/93 4.7 7.0 ZZ = Standard Jacket Color YL (Yellow - Singlemode Cable) OR (Orange - Multimode or Composite Cable) AQ (Aqua - LaserCore Cable) Fiber Identification Colors: 1/Blue, 2/Orange Riser Simplex Cable Riser Rated Outer Jacket 900 µm Tight Buffer 250 µm Optical Fiber Aramid Yarn Riser Zipcord Cable Riser Rated Outer Jacket Aramid Yarn 900 µm Tight Buffer 250 µm Optical Fiber Riser 2-Fiber Interconnect Cable Riser Rated Outer Jacket Aramid Yarn 900 µm Tight Buffer 250 µm Optical Fiber Mechanical Properties Description Specification Test Method Operating Temperature -4 to 158 F (-20 to 70 C) FOTP-3 Installation Temperature -4 to 158 F (-20 to 70 C) N/A Storage Temperature -40 to 158 F (-40 to 70 C) N/A Crush Resistance Exceeds 57 lbf/in (10N/mm) FOTP-41 Impact Resistance Exceeds 0.54 lb ft (0.74 N m) FOTP-25 Flexing Exceeds 300 cycles FOTP-104 Twist Bend Exceeds FOTP-85 CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. F61
Premise Plenum-Rated Distribution Cable For Indoor Applications that Require a Plenum Rating Meets critical NEC/CEC plenum (OFNP) safety standards Color-coded subunits and color-coded fibers help ease installation Outer Minimum Bend Radius Maximum Tensile Load Weight Fiber Count Catalog Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./newtons kft km 2 Fibers P-ØØ2-DS-XY-FSUZZ 0.15/3.9 3.1/7.8 1.5/3.9 225/1001 68/300 8.8 13.1 4 Fibers P-ØØ4-DS-XY-FSUZZ 0.17/4.4 3.4/8.7 1.7/4.4 300/1335 90/400 12.2 18.2 6 Fibers P-ØØ6-DS-XY-FSUZZ 0.19/4.8 3.8/9.7 1.9/4.8 300/1335 90/400 15.1 22.5 8 Fibers P-ØØ8-DS-XY-FSUZZ 0.20/5.1 4.0/10.2 2.0/5.1 300/1335 90/400 16.8 24.9 12 Fibers P-Ø12-DS-XY-FSUZZ 0.23/5.8 4.6/11.7 2.3/5.8 300/1335 90/400 20.8 30.9 18 Fibers P-Ø18-DS-XY-FSUZZ 0.31/7.9 6.2/15.8 3.1/7.9 300/1335 90/400 40.9 60.9 24 Fibers P-Ø24-DS-XY-FSUZZ 0.33/8.5 6.7/16.9 3.3/8.5 300/1335 90/400 47.3 70.4 36 Fibers (3 subunits) P-Ø36-DS-XY-FMUZZ 0.54/13.7 10.8/27.4 5.4/13.7 800/3560 240/1068 128.0 191.0 48 Fibers (4 subunits) P-Ø48-DS-XY-FMUZZ 0.59/15.1 11.9/30.2 5.9/15.1 800/3560 240/1068 138.0 205.0 60 Fibers (5 subunits) P-Ø6Ø-DS-XY-FMUZZ 0.68/17.2 13.6/34.4 6.8/17.2 1000/4450 300/1335 190.0 282.0 72 Fibers (6 subunits) P-Ø72-DS-XY-FMUZZ 0.75/19.1 15.1/38.2 7.5/19.1 1000/4450 300/1335 237.0 353.0 96 Fibers (8 subunits) P-Ø96-DS-XY-FMUZZ 0.91/23.1 18.2/46.1 9.1/23.1 1000/4450 300/1335 361.0 537.0 144 Fibers (12 subunits) P-144-DS-XY-FMUZZ 0.97/24.8 19.5/49.5 9.7/24.8 1000/4450 300/1335 357.0 531.0 Singlemode/Multimode P-XXX-DS-CM-FSUOR/AAaaa/BBbbb Composite (4-144 Fibers) P-XXX-DS-CM-FMUOR/AAaaa/BBbbb Custom design - sizes/specs will vary depending on fiber count Tight Buffer/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Subunits are color-coded for easy identification Plenum Distribution Cable (Multi-Unit) (72 and 12 Fiber Versions Shown) Plenum Rated Outer Jacket Central Strength Member 12 Fiber Subunit Ripcord 12 Fiber Unit (Single Unit) Riser Rated Outer Jacket Aramid Yarn 900 µm Tight Buffer 250 µm Optical Fiber Ripcord Mechanical Properties Description Specification Test Method Operating Temperature -4 to 158 F (-20 to 70 C) FOTP-3 Installation Temperature 32 to 158 F (0 to 70 C) N/A Storage Temperature -40 to 158 F (-40 to 70 C) N/A Crush Resistance Exceeds 57 lbf/in (10N/mm) FOTP-41 Impact Resistance Exceeds 4.34 lb ft (5.88 N m) FOTP-25 Flexing Exceeds 100 cycles FOTP-104 Twist Bend Exceeds FOTP-85 CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. F62
Premise Plenum-Rated Cordage Cable Several Constructions Available for a Variety of Uses For Indoor Applications that Require a Plenum Rating Meets critical NEC/CEC plenum (OFNP) safety standards Simplex and zipcord cables are available in a variety of sizes Designed for ease of handling and termination Cable Type/Unit Size Catalog Outer Minimum Bend Radius Maximum Tensile Load Weight Number Diameter Loaded Unloaded Short term Long term lbs/ kg/ inch/mm inch/cm inch/cm lbs./ Newtons lbs./newtons kft km Simplex/1.6mm P-ØØ1-SP-XY-F16ZZ 0.067/1.70 2.0/5.0 1.2/3.0 35/156 11/47 2.0 3.0 Simplex/2.0mm P-ØØ1-SP-XY-F20ZZ 0.079/2.00 2.0/5.0 1.2/3.0 50/222 15/67 3.0 4.5 Simplex/2.5mm P-ØØ1-SP-XY-F25ZZ 0.098/2.50 2.0/5.0 1.2/3.0 60/267 18/80 4.9 7.3 Simplex/2.9mm P-ØØ1-SP-XY-F29ZZ 0.114/2.90 2.3/5.8 1.2/3.0 60/267 18/80 6.8 10.1 Zipcord/1.6mm P-ØØ2-ZC-XY-F16ZZ 0.067 x 0.138/ 2.0/5.0 1.2/3.0 70/311 21/93 4.0 6.0 1.70 x 3.50 Zipcord/2.0mm P-ØØ2-ZC-XY-F20ZZ 0.079 x 0.161/ 2.0/5.0 1.2/3.0 80/356 24/107 5.9 8.8 2.00 x 4.10 Zipcord/2.5mm P-ØØ2-ZC-XY-F25ZZ 0.098 x 0.201/ 2.0/5.0 1.2/3.0 90/400 27/120 9.8 14.6 2.50 x 5.10 Zipcord/2.9mm P-ØØ2-ZC-XY-F29ZZ 0.114 x 0.232/ 2.3/5.8 1.2/3.0 90/400 27/120 13.6 20.2 2.90 x 5.90 Interconnect/2.9mm P-ØØ2-IC-XY-F29ZZ 0.114/2.90 2.3/5.8 1.2/3.0 70/311 21/93 5.8 8.6 ZZ = Standard Jacket Color YL (Yellow - Singlemode Cable) OR (Orange - Multimode or Composite Cable) AQ (Aqua - LaserCore Cable) Fiber Identification Colors: 1/Blue, 2/Orange Plenum Simplex Cable Plenum Rated Outer Jacket 900 µm Tight Buffer 250 µm Optical Fiber Aramid Yarn Plenum Zipcord Cable Plenum Rated Outer Jacket Aramid Yarn 900 µm Tight Buffer 250 µm Optical Fiber Plenum 2-Fiber Interconnect Cable Plenum Rated Outer Jacket Aramid Yarn 900 µm Tight Buffer 250 µm Optical Fiber Mechanical Properties Description Specification Test Method Operating Temperature -4 to 158 F (-20 to 70 C) FOTP-3 Installation Temperature 32 to 158 F (0 to 70 C) N/A Storage Temperature -40 to 158 F (-40 to 70 C) N/A Crush Resistance Exceeds 57 lbf/in (10N/mm) FOTP-41 Impact Resistance Exceeds 0.54 lb ft (0.74 N m) FOTP-25 Flexing Exceeds 300 cycles FOTP-104 Twist Bend Exceeds FOTP-85 CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. F63
Fiber Optic Cable Packaging and Shipping Information Packaging and Shipping Fiber optic cable is packaged for shipment on wooden or composite reels. Each package contains only one continuous length of cable. The packaging is designed to prevent damage to the cable during shipping and handling. Fiber cable reels are protected with a reel wrap, the highest technology available today. This wrap is stronger, lighter and more environmentally friendly than other methods of lagging. In addition, reel wrap is simple to remove from the reel and readily disposable. All reel sizes between 35 and 78 inches will be blocked and palletized to help ensure safe arrival to the customer. Reels larger than 78 inches are placed on the rolling edge and securely fastened to the trailer during shipment. F Flange Diameter T Traverse Width D Drum Diameter Each reel is plainly marked to indicate the direction in which it should be rolled to prevent loosening of the cable on the reel. Method of Shipment CommScope s customary method of shipment of fiber optic cable from Claremont, North Carolina to the purchaser s site will vary depending on factors such as the size and number of cable reels, and the destination location. Shipper options include Federal Express, UPS, BAX, LTL motor freight carriers and CommScope s own fleet of trucks, Cable Transport. Some trucks within CommScope s fleet are equipped with Cargo Master equipment for ease in unloading cable reels on location where no loading dock is available. CommScope has red arm Cargo Masters, which can lift anything 2,500 pounds or less. CommScope also has white arm Cargo Masters which will lift anything up to 8,000 pounds that is on an 84 reel or smaller. These specially equipped trucks are available by request. International Packaging Products shipped outside the continental United States are protected with reel wrap, lagged with wood, and blocked and palletized (for reel sizes between 35 and 78 inches) or placed on the rolling edge and securely fastened to international shipping containers. F64
Fiber Optic Cable Packaging and Shipping Information Outside Plant Dry Stranded Loose Tube Armored (D-LA) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1 35 x 16.5 x 18 70 3,805 3,752 2,834 2,414 1,742 1,722 1,411 42 x 24 x 24 109 6,706 6,008 4,988 3,838 3,101 3,101 2,510 42 x 22 x 29.75 118 8,816 8,021 6,249 5,231 3,885 3,885 3,165 48 x 22 x 32.5 140 15,058 13,828 10,597 8,624 6,868 6,868 5,279 54 x 24 x 28 350 16,987 15,888 12,526 9,881 7,914 7,914 5,821 60 x 30 x 32 433 22,681 20,988 16,528 12,973 10,548 10,548 7,724 66 x 30 x 31 580 29,384 26,363 20,713 16,715 12,885 12,885 9,987 72 x 36 x 36 627 38,603 34,883 27,084 21,831 17,174 17,174 13,002 78 x 36 x 36 758 47,398 44,759 34,523 27,371 22,174 22,114 16,407 84 x 40 x 40 850 59,951 56,558 43,978 35,569 27,634 27,634 20,574 88 x 40 x 40 958 N/A 59,942 50,344 39,867 31,433 31,433 23,844 96 x 44 x 46 1,125 N/A N/A 59,910 56,045 42,748 42,748 33,491 All Units in Feet 2 Flange Clearance Outside Plant Dry Stranded Loose Tube Non-Armored (D-LN) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1 35 x 16.5 x 18 70 5,195 4,783 3,671 2,847 2,054 2,054 1,704 42 x 24 x 24 109 8,572 7,784 6,029 4,566 3,683 3,683 2,630 42 x 22 x 29.75 118 11,173 10,816 7,922 6,156 4,614 4,614 3,755 48 x 22 x 32.5 140 19,027 17,654 12,932 10,648 7,832 7,832 6,035 54 x 24 x 28 350 21,977 20,432 15,705 11,680 8,819 8,819 7,157 60 x 30 x 32 433 29,256 27,346 20,773 15,736 11,903 11,903 9,388 66 x 30 x 31 580 36,834 34,662 26,098 20,458 15,199 15,199 11,848 72 x 36 x 36 627 48,165 45,550 34,589 26,798 20,008 20,008 15,583 78 x 36 x 36 758 59,950 56,756 42,952 34,179 25,296 25,296 19,307 84 x 40 x 40 850 N/A 59,942 54,434 42,065 33,135 33,135 23,925 88 x 40 x 40 958 N/A N/A 59,910 48,310 37,275 37,275 27,448 96 x 44 x 46 1125 N/A N/A N/A 59,872 46,351 46,351 33,491 All Units in Feet 2 Flange Clearance Outside Plant Dry Loose Tube Double Jacket, Single Armor (D-L2) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1 35 x 16.5 x 18 70 2,407 2,110 1,735 1,449 1,191 1,191 N/A 42 x 24 x 24 109 3,831 3,756 3,091 2,560 2,083 2,083 1,651 42 x 22 x 29.75 118 5,328 5,145 3,963 3,289 2,684 2,684 2,204 48 x 22 x 32.5 140 8,760 8,509 6,835 5,932 4,651 4,651 3,913 54 x 24 x 28 350 10,464 9,727 7,874 6,517 5,595 5,595 4,319 60 x 30 x 32 433 13,973 12,793 10,502 8,590 7,459 7,459 5,864 66 x 30 x 31 580 17,505 16,490 13,106 10,960 9,034 9,034 7,270 72 x 36 x 36 627 23,217 21,578 17,098 14,480 11,843 11,843 9,442 78 x 36 x 36 758 28,917 27,071 22,003 19,034 15,108 15,108 11,597 84 x 40 x 40 850 35,461 35,237 27,501 23,625 19,069 19,069 15,869 88 x 40 x 40 958 41,206 39,508 31,272 27,115 22,231 22,231 17,770 96 x 44 x 46 1125 55,862 53,103 43,166 36,645 29,694 29,694 23,862 All Units in Feet 2 Flange Clearance F65 Reel Weights subject to change without notice.
Fiber Optic Cable Packaging and Shipping Information Outside Plant Stranded Loose Tube Armored (O-LA/25T) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1 3 35 x 16.5 x 18 70 4,118 3,746 2,831 2,411 1,741 1,741 1,410 42 x 24 x 24 109 6,832 6,121 5,097 3,836 3,099 3,099 2,509 42 x 22 x 29.75 118 8,950 8,615 6,778 5,227 3,882 3,882 3,163 48 x 22 x 32.5 140 15,045 14,008 10,761 8,615 6,861 6,861 5,276 54 x 24 x 28 350 16,972 15,856 12,506 9,869 7,906 7,906 5,817 60 x 30 x 32 433 22,663 21,265 16,786 12,960 10,539 10,539 7,719 66 x 30 x 31 580 29,357 27,785 21,621 16,697 12,872 12,872 9,980 72 x 36 x 36 627 38,572 36,172 28,238 21,809 17,158 17,158 12,994 78 x 36 x 36 758 48,885 44,670 34,470 28,502 22,092 22,092 16,396 84 x 40 x 40 850 59,951 57,121 44,507 35,530 27,607 27,607 20,560 88 x 40 x 40 958 N/A 59,942 50,944 41,293 31,401 31,401 23,827 96 x 44 x 46 1125 N/A N/a 59,910 55,980 43,342 43,342 33,491 All Units in Feet 2 Flange Clearance Outside Plant Stranded Loose Tube Non-Armored (O-LN/25T) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1 35 x 16.5 x 18 70 5,189 4,773 3,666 2,8473 2,052 2,052 1,703 42 x 24 x 24 109 8,565 7,772 6,023 4,562 3,681 3,681 2,629 42 x 22 x 29.75 118 11,162 10,797 7,911 6,149 4,611 4,611 3,752 48 x 22 x 32.5 140 19,002 17,847 13,878 10,633 7,825 7,825 6,031 54 x 24 x 28 350 21,947 20,693 15,677 12.329 9,001 9,011 7,152 60 x 30 x 32 433 29,221 27,651 21.056 16,579 11,895 11,895 9,382 66 x 30 x 31 580 36,785 34,583 26,054 20,428 15,186 15,186 11,849 72 x 36 x 36 627 48,108 45,458 34,537 26,762 19,992 19,992 15,573 78 x 36 x 36 758 59,952 56,628 42,879 34,127 25,274 25,274 19,292 84 x 40 x 40 850 N/A 59,942 54,346 44,128 33,108 33,108 23,908 88 x 40 x 40 958 N/A N/A 59,910 48,896 37,242 37,242 27,427 96 x 44 x 46 1125 N/A N/A N/A 59,873 46,351 46,351 33,491 All Units in Feet Outside Plant Loose Tube Double Jacket, Single Armor (O-L2/25T) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6@1 15@9@1 35 x 16.5 x 18 70 2,407 2,110 1,735 1,449 1,191 1,191 N/A 42 x 24 x 24 109 3,831 3,756 3,091 2,560 2,083 2,083 1,651 42 x 22 x 29.75 118 5,328 5,145 3,963 3,289 2,684 2,684 2,204 48 x 22 x 32.5 140 8,760 8,509 6,835 5,932 4,651 4,651 3,913 54 x 24 x 28 350 10,464 9,727 7,874 6,517 5,595 5,595 4,319 60 x 30 x 32 433 13,973 12,793 10,502 8,590 7,459 7,459 5,864 66 x 30 x 31 580 17,505 16,490 13,106 10,960 9,034 9,034 7,270 72 x 36 x 36 627 23,217 21,578 17,098 14,480 11,843 11,843 9,442 78 x 36 x 36 758 28,917 27,071 22,003 19,034 15,108 15,108 11,597 84 x 40 x 40 850 35,461 35,237 27,501 23,625 19,069 19,069 15,869 88 x 40 x 40 958 41,206 39,508 31,272 27,115 22,231 22,231 17,770 96 x 44 x 46 1125 55,862 53,103 43,166 36,645 29,694 29,694 23,862 All Units in Feet 2 Flange Clearance 2 Flange Clearance Reel Weights subject to change without notice. F66
Fiber Optic Cable Packaging and Shipping Information Outside Plant Stranded Loose Tube Armored (O-LA), Loose Tube Non-Armored (O-LN) and Loose Tube Double Jacket, Single Armored (O-L2) High Density Cables Outside Plant Stranded Loose Tube Armored (O-LA/20T) and Loose Tube Non-Armored (O-LN/20T) Cables Armored (O-LA/20T) Non-Armored (O-LN/20T) Flange x Drum x Reel 2-72 74-96 98-120 122-144 2-72 74-96 98-120 122-144 Traverse Weight (lbs) 6@1 8@1 10@1 12@1 6@1 8@1 10@1 12@1 35 x 16.5 x 18 70 4,698 3,666 3,169 2,470 5,935 4,766 3,731 2,901 42 x 24 x 24 109 7,678 6,023 5,178 4,313 9,786 7,901 6,609 5,076 42 x 22 x 29.75 118 10,032 7,911 6,978 5,403 13,244 10,939 8,725 6,871 48 x 22 x 32.5 140 16,664 13,878 11,540 9,487 21,938 17,820 14,151 11,578 54 x 24 x 28 350 19,397 15,677 13,568 10,599 24,908 20,659 16,834 12,668 60 x 30 x 32 433 26,033 21,056 17,818 14,131 33,282 27,612 22,501 16,975 66 x 30 x 31 580 32,770 26,054 21,785 17,697 42,214 34,527 27,656 21,859 72 x 36 x 36 627 43,244 34,537 28,837 23,428 55,904 45,920 36,497 28,503 78 x 36 x 36 758 54,160 42,879 36,490 29,155 59,962 57,194 46,540 36,083 84 x 40 x 40 850 59,962 54,346 46,879 37,670 N/A 59,945 59,333 46,421 88 x 40 x 40 958 N/A 59,945 53,479 43,599 N/A N/A 59,920 52,968 96 x 44 x 46 1125 N/A N/A 59,920 58,733 N/A N/A N/A 59,885 All Units in Feet 2 Flange Clearance Armored (O-LA) Non-Armored (O-LN) Double Jacket, Single Armored (O-L2) Flange x Drum x Reel 290-432F 434-576F 290-432F 434-576F 290-432F Traverse Weight (lbs) 12@6@1 15@9@1 12@6@1 15@9@1 12@6@1 35 x 16.5 x 18 70 N/A N/A N/A N/A N/A 42 x 24 x 25 109 1,713 1,327 2,099 1,612 1,325 42 x 22 x 29.75 118 2,270 1,713 2,709 2,104 1,770 48 x 22 x 32.5 176 4,019 2,884 4,585 3,387 2,875 54 x 24 x 28 370 4,456 3,341 5,059 3,757 3,330 60 x 30 x 32 433 5,855 4,469 6,781 4,998 4,457 66 x 30 x 32 506 7,472 5,902 9,145 6,483 5,882 72 x 36 x 36 627 9,670 7,327 11,427 8,484 7,521 78 x 36 x 36 758 12,648 9,224 13,778 10,545 9,464 84 x 40 x 40 913 15,844 11,853 17,518 13,389 12,126 88 x 40 x 40 958 17,740 13,489 20,545 15,143 13,796 96 x 44 x 46 1,020 24,298 18,714 27,682 20,696 19,074 All Units in Feet 2 Flange Clearance F67 Outside Plant Stranded Loose Tube Armored (Z-LA/20G) and Loose Tube Non-Armored (Z-LN/20G) Cables Armored (Z-LA/20G) Non-Armored (Z-LN/20G) Flange x Drum x Reel 2-72 74-96 98-120 122-144 2-72 74-96 98-120 122-144 Traverse Weight (lbs) 6@1 8@1 10@1 12@1 6@1 8@1 10@1 12@1 35 x 16.5 x 18 70 3,383 2,838 2,469 2,066 4,276 3,753 2,901 2,471 42 x 24 x 24 109 5,923 4,993 4,312 3,601 7,572 6,010 5,076 4,315 42 x 22 x 29.75 118 7,813 6,256 5,403 4,536 9,784 8,023 6,871 5,406 48 x 22 x 32.5 140 12,784 10,612 9,485 7,727 16,317 13,832 11,578 9,493 54 x 24 x 28 350 14,747 12,545 10,596 8,878 18,383 15,893 12,668 10,606 60 x 30 x 32 433 19,573 16,550 14,128 11,737 24,408 20,994 16,975 14,140 66 x 30 x 31 580 24,770 20,387 17,693 14,988 31,366 26,371 21,859 17,709 72 x 36 x 36 627 32,930 27,120 23,423 19,773 40,990 34,892 28,503 23,443 78 x 36 x 36 758 42,545 34,575 29,148 23,932 51,613 44,772 36,083 29,175 84 x 40 x 40 850 53,982 44,042 37,662 31,000 59,962 56,574 46,421 37,696 88 x 40 x 40 958 59,962 50,423 43,589 34,989 N/A 59,945 52,968 43,631 96 x 44 x 46 1125 N/A 59,945 58,719 48,345 N/A N/A 59,920 58,775 All Units in Feet 2 Flange Clearance Reel Weights subject to change without notice.
Fiber Optic Cable Packaging and Shipping Information Outside Plant Figure-8 Armored (M-LA) and Non-Armored (M-LN) Cables Armored (M LA) Non-Armored (M LN) Flange x Drum x Reel 5@1 6@1 12@1 12@6 15@9 5@1 6@1 12@1 12@6 15@9 Traverse Weight (lbs) 2-60 62-72 74-144 146-216 218-288 2-60 62-72 74-144 146-216 218-288 35 x 16.5 x 18 70 1,671 1,559 867 867 N/A 1,955 1,748 909 909 N/A 42 x 24 x 24 109 2,807 2,498 1,359 1,359 1,082 3,358 3,036 1,605 1,605 1,309 42 x 22 x 29.75 118 3,726 3,380 1,983 1,983 1,449 4,486 3,994 2,032 2,032 1,711 48 x 22 x 32.5 140 6,218 5,801 2,961 2,961 2,578 7,546 6,733 3,431 3,431 2,637 54 x 24 x 28 350 7,256 6,443 3,594 3,594 2,887 8,653 7,557 3,965 3,965 3,242 60 x 30 x 32 433 9,604 8,569 4,751 4,751 3,862 11,364 10,302 5,417 5,417 4,308 66 x 30 x 32 580 12,283 11,179 6,306 6,306 4,717 14,727 13,068 6,820 6,820 5,198 72 x 36 x 36 627 16,062 14,678 8,271 8,271 6,309 19,587 17,017 8,905 8,905 6,907 78 x 36 x 36 758 20,201 18,030 9,887 9,887 7,752 24,056 21,264 11,129 11,129 8,919 84 x 40 x 40 850 26,345 23,153 13,036 13,036 9,878 30,211 26,957 14,509 14,509 11,256 88 x 40 x 40 958 29,968 26,599 14,411 14,411 11,745 34,498 30,567 15,929 15,929 12,544 96 x 44 x 46 1,125 34,498 34,498 20,364 20,364 16,271 N/A 34,498 22,219 22,219 17,227 All Units in Feet 2 Flange Clearance Outside Plant Figure-8 Armored (M-LA/25D) and Non-Armored (M-LN/25D) Cables Armored (M LA/25D) Non-Armored (M LN/25D) Flange x Drum x Reel 5@1 1@1 5@1 5@1 5@1 5@1 Traverse Weight (lbs) 2-60 2-60 2-60 2-60 2-60 2-60 35 x 16.5 x 18 70 2,266 2,069 1,970 2,773 2,551 2,329 42 x 24 x 24 109 3,719 3,359 3,239 4,633 4,088 3,816 42 x 22 x 29.75 118 5,363 4,799 4,516 6,411 5,785 5,316 48 x 22 x 32.5 140 8,645 7,821 7,410 10,421 9,494 8,800 54 x 24 x 28 350 9,935 8,861 8,324 12,342 11,108 10,182 60 x 30 x 32 433 13,124 11,874 11,249 16,146 14,711 13,634 66 x 30 x 32 580 17,245 15,563 14,722 20,543 18,208 17,275 72 x 36 x 36 627 22,352 20,450 19,023 26,934 24,294 22,709 78 x 36 x 36 758 27,601 25,252 23,490 33,549 30,000 28,286 84 x 40 x 40 850 34,498 30,000 30,215 34,498 N/A 34,498 88 x 40 x 40 958 N/A N/A 34,063 N/A N/A N/A 96 x 44 x 46 1,125 N/A N/A 34,498 N/A N/A N/A All Units in Feet 2 Flange Clearance Outside Plant ADSS Loose Tube (S-LN) Cables Flange x Drum x Reel 2-60F Traverse Weight (lbs) 5@1 35 x 16.5 x 18 70 3,733 42 x 24 x 24 109 6,612 42 x 22 x 29.75 118 8,729 48 x 22 x 32.5 140 13,954 54 x 24 x 28 350 16,844 60 x 30 x 32 433 22,187 66 x 30 x 31 580 27,672 72 x 36 x 36 627 36,516 78 x 36 x 36 758 45,075 84 x 40 x 40 850 59,367 88 x 40 x 40 958 66,768 96 x 44 x 46 1,125 85,636 All Units in Feet 2 Flange Clearance Reel Weights subject to change without notice. F68
Fiber Optic Cable Packaging and Shipping Information Indoor/Outdoor Stranded Loose Tube Non-Armored (R-LN/25D) Cables Flange x Drum x Reel 2-60F 62-72F 74-96F 98-120F 122-144F 146-216F 218-288F Traverse Weight (lbs) 5@1 6@1 8@1 10@1 12@1 12@6 15@9 3 35 x 16.5 x 18 70 3,808 3,748 2,831 2,411 1,741 1,691 1,361 42 x 24 x 24 109 6,710 6,123 5,097 3,836 3,099 3,035 2,145 42 x 22 x 29.75 118 8,822 8,619 6,778 5,227 3,882 3,825 3,103 48 x 22 x 32.5 140 15,071 14,016 10,761 8,615 6,860 6,125 4,737 54 x 24 x 28 350 17,002 15,865 12,506 9,869 7,904 7,280 5,715 60 x 30 x 32 433 22,699 21,275 16,786 12,960 10,537 9,533 7,600 66 x 30 x 31 580 29,410 27,380 21,621 16,697 12,870 12,025 9,834 72 x 36 x 36 627 38,634 36,191 28,238 21,809 17,155 15,780 12,830 78 x 36 x 36 758 47,440 44,695 34,470 28,502 22,088 20,519 15,336 84 x 40 x 40 850 59,950 57,152 44,507 35,530 27,602 25,786 20,362 88 x 40 x 40 958 N/A 59,942 50,944 41,293 31,394 29,456 22,510 96 x 44 x 46 1125 N/A N/A 59,910 55,980 43,333 40,371 31,361 All Units in Feet 2 Flange Clearance Indoor/Outdoor Stranded Loose Tube Plenum Non-Armored (P-LN/25D) Cables and Plenum/Interlocking Armor (P-LZ/25D) Cables Non-Armored (P-LN/25D) Interlocking Armor (P-LZ/25D) Flange x Drum x Reel 5@1 6@1 8@1 10@1 12@1 5@1 6@1 8@1 10@1 12@1 Traverse Weight (lbs) 2-60 62-72 74-144 146-216 218-288 2-60 62-72 74-144 146-216 218-288 35 x 16.5 x 18 70 5,466 5,297 3,821 2,901 2,343 N/A N/A N/A N/A N/A 42 x 24 x 24 109 9,523 8,699 6,728 5,076 3,753 2,701 2,701 2,080 2,034 N/A 42 x 22 x 29.75 118 12,224 11,860 8,850 6,871 5,249 3,832 3,832 N/A N/A N/A 48 x 22 x 32.5 140 20,610 19,205 14,120 11,578 8,662 6,140 6,140 N/A N/A N/A 54 x 24 x 28 350 23,795 22,219 16,794 12,668 9,714 7,118 7,118 5,581 4,936 N/A 60 x 30 x 32 433 31,486 29,539 22,455 16,975 13,023 9,555 9,555 7,442 6,637 5,130 66 x 30 x 32 580 40,683 37,957 28,009 21,859 16,468 10,000 10,000 9,012 8,128 6,448 72 x 36 x 36 627 53,412 50,160 36,895 28,503 21,553 N/A N/A 10,000 10,000 8,444 78 x 36 x 36 758 59,950 59,942 47,033 36,083 27,035 N/A N/A N/A N/A 10,000 84 x 40 x 40 850 N/A N/A 59,199 46,421 35,191 N/A N/A N/A N/A N/A 88 x 40 x 40 958 N/A N/A 59,910 52,968 39,453 N/A N/A N/A N/A N/A 96 x 44 x 46 1,125 N/A N/a N/A 59,872 46,351 N/A N/A N/A N/A N/A All Units in Feet 2 Flange Clearance Indoor/Outdoor and Outside Plant Central Tube Non-Armored (R-CN, O-CN) Cables Flange x Drum x Reel RCN CN CN CN Traverse Weight (lbs) 1-24 1-24 26-48 50-96 35 x 16.5 x 18 70 5,288 5,288 3,668 2,780 42 x 24 x 24 109 8,687 8,687 6,026 4,485 42 x 22 x 29.75 118 12,006 12,006 7,917 6,076 48 x 22 x 32.5 140 19,168 19,168 12,922 9,707 54 x 24 x 28 350 22,173 22,173 15,691 11,542 60 x 30 x 32 433 29,487 29,487 20,757 15,307 66 x 30 x 31 580 38,371 38,371 26,076 19,003 72 x 36 x 36 627 48,648 48,648 34,563 25,028 78 x 36 x 36 758 N/A N/A 42,915 32,156 84 x 40 x 40 850 N/A N/A 48,593 33,252 All Units in Feet 2 Flange Clearance F69 Reel Weights subject to change without notice.
Fiber Optic Cable Packaging and Shipping Information Outside Plant Central Tube Armored (O-CA) Cables Flange x Drum x Reel CA CA CA Traverse Weight (lbs) 2-24 26-48 50-96 35 x 16.5 x 18 70 4,278 3,254 2,409 42 x 24 x 24 109 7,574 5,169 3,833 42 x 22 x 29.75 118 9,786 6,964 5,331 48 x 22 x 32.5 140 16,322 11,700 8,768 54 x 24 x 28 350 18,389 13,532 9,858 60 x 30 x 32 433 24,414 18,068 13,192 66 x 30 x 31 580 31,376 23,067 17,521 72 x 36 x 36 627 41,002 30,430 22,855 78 x 36 x 36 758 51,545 38,278 28,469 84 x 40 x 40 850 N/A 46,761 33,252 88 x 40 x 40 958 N/A 51,545 N/A All Units in Feet 2 Flange Clearance Outside Plant Flat Drop (O-DF, O-DF/HY) Cables Flange x Drum x Reel ODF ODF/HY Traverse Weight (lbs) 1-12 1-12 34 x 6.75 x 12 1 1,000 11,918 35 x 16.5 x 18 70 14,350 19,606 42 x 24 x 24 92 23,926 25,282 42 x 22 x 29.75 118 31,728 43,324 48 x 22 x 32.5 140 48,685 48,685 All Units in Feet 2 Flange Clearance LZSH Indoor/Outdoor (Z-DN) Cables Flange x Drum x Reel ZDN ZDN/20T Traverse Weight (lbs) 1-12 1-12 35 x 16.5 x 18 70 7,706 14,403 42 x 24 x 24 92 12,980 24,286 42 x 22 x 29.75 118 17,195 32,181 48 x 22 x 32.5 140 28,321 48,685 54 x 24 x 28 350 32,726 N/A 60 x 30 x 32 433 43,439 N/A 66 x 30 x 31 580 48,671 N/A All Units in Feet 2 Flange Clearance Outside Plant Drop (O-DA, O-DN, M-MN and M-DN) Cables Flange x Drum x Reel DA DN MMN MDN/109 MDN Traverse Weight (lbs) 1-12 1-12 1-12 1-6 1-12 14 x 6.75 x 12 12 N/A N/A N/A N/A N/A 35 x 16.5 x 18 70 8,498 7,087 15,530 9,657 6,782 42 x 24 x 24 92 14,146 11,861 26,042 16,103 11,596 42 x 22 x 29.75 118 18,697 15,751 34,948 21,560 14,957 48 x 22 x 32.5 140 30,251 26,446 41,001 34,498 25,375 54 x 24 x 28 350 36,099 30,945 N/A N/A 28,829 60 x 30 x 32 433 44,200 40,792 N/A N/A 38,469 66 x 30 x 31 627 N/A 48,684 N/A N/A 48,674 All Units in Feet 2 Flange Clearance Hybrid Loose Tube Non-Armored/Coax (O-DN-HY, M-DN-HY) Cables Flange x Drum x Reel Fiber + Coax Hybrid Self Supporting Fiber + Coax Hybrid Traverse Weight (lbs) DN (1-12F) DN (1-12F) 35 x 16.5 x 18 70 4,998 3,791 42 x 24 x 24 109 8,476 6,520 42 x 22 x 29.75 118 11,362 8,703 48 x 22 x 32.5 140 19,262 14,817 54 x 24 x 28 350 22,714 17,282 60 x 30 x 32 433 29,842 22,955 66 x 30 x 31 580 37,946 29,017 72 x 36 x 36 627 44,198 37,863 78 x 36 x 36 758 N/A 44,198 All Units in Feet 2 Flange Clearance Reel Weights subject to change without notice. F70
Fiber Optic Cable Packaging and Shipping Information Low-Smoke Zero-Halogen (LSZH) Distribution (Z-DS) Cables Fiber Construction 18x12x12 22x12x12 30x12x12 35x16.5x18 35x16.5x18 42x24x25 42x22x29.75 48x22x32.5 54x24x28 60x30x32 66x30x32 72x36x36 78x36x36 Type FT FT FT FT FT FT FT FT FT FT FT FT FT 2 SU 4,090 8,991 22,563 28,000 N/A N/A N/A N/A N/A N/A N/A N/A N/A 4 SU 2,419 5,278 12,881 24,443 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 6 SU 1,976 4,287 10,420 19,855 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 8 SU 1,583 3,418 8,294 15,862 N/A 27,646 28,000 N/A N/A N/A N/A N/A N/A 12 SU 1,228 2,626 6,326 12,375 N/A 21,514 28,000 N/A N/A N/A N/A N/A N/A 18 SU N/A N/A N/A 10,069 N/A 17,289 23,123 28,000 N/A N/A N/A N/A N/A 24 SU N/A N/A N/A 8,393 N/A 14,595 18,966 28,000 N/A N/A N/A N/A N/A 18 MU N/A N/A N/A N/A 2,115 3,859 5,266 8,695 9,540 12,822 16,857 21,628 27,141 24 MU N/A N/A N/A N/A 1,737 3,271 4,060 6,990 7,885 10,516 13,410 17,120 22,035 36 MU N/A N/A N/A N/A 1,692 3,125 3,919 6,262 7,282 9,536 12,302 15,784 20,524 48 MU N/A N/A N/A N/A 1,365 2,220 3,197 4,750 5,732 7,619 10,116 12,865 15,381 60 MU N/A N/A N/A N/A N/A 2,043 2,655 4,085 4,547 5,963 8,176 10,536 12,816 72 MU N/A N/A N/A N/A N/A 1,669 2,162 3,466 3,864 5,122 6,639 8,431 11,188 Reel Weights subject to change without notice. Riser-Rated Distribution (R-DS) Cables Fiber Construction 18x12x12 22x12x12 30x12x12 35x16.5x18 35x16.5x18 42x24x25 42x22x29.75 48x22x32.5 54x24x28 60x30x32 66x30x32 72x36x36 78x36x36 Type FT FT FT FT FT FT FT FT FT FT FT FT FT 2 SU 3,553 8,168 20,028 28,000 N/A N/A N/A N/A N/A N/A N/A N/A N/A 4 SU 2,522 5,802 14,170 26,713 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 6 SU 2,419 5,278 12,881 24,443 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 8 SU 1,976 4,287 10,420 19,855 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 12 SU 1,640 3,525 8,866 16,947 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 18 SU N/A N/A N/A 10,820 N/A 18,657 24,907 28,000 N/A N/A N/A N/A N/A 24 SU N/A N/A N/A 9,097 N/A 15,669 20,392 28,000 N/A N/A N/A N/A N/A 18 MU N/A N/A N/A N/A 3,673 6,273 8,058 13,136 15,714 20,784 26,930 28,000 N/A 24 MU N/A N/A N/A N/A 2,529 4,600 6,211 9,912 11,586 15,357 19,768 25,111 28,000 36 MU N/A N/A N/A N/A 2,475 4,531 5,522 9,036 10,625 14,161 18,409 23,479 28,000 48 MU N/A N/A N/A N/A 2,061 3,790 4,728 7,861 8,854 11,710 15,571 20,078 25,397 60 MU N/A N/A N/A N/A 1,699 2,785 3,840 6,154 7,135 9,576 12,361 15,541 19,248 72 MU N/A N/A N/A N/A 1,360 2,215 3,186 4,849 5,707 7,591 10,072 12,815 16,187 96 MU N/A N/A N/A N/A N/A 1,661 2,150 3,443 3,968 5,245 7,340 9,278 11,407 144 MU N/A N/A N/A N/A N/A 1,327 1,713 288 3,341 4,469 5,902 7,327 9,224 Plenum-Rated Distribution (P-DS) Cables Fiber Construction 18x12x12 22x12x12 30x12x12 35x16.5x18 35x16.5x25 42x24x25 42x22x29.75 48x22x32.5 54x24x28 60x30x32 66x30x32 72x36x36 78x36x36 Type FT FT FT FT FT FT FT FT FT FT FT FT FT 2 SU 4,090 8,991 22,563 28,000 N/A N/A N/A N/A N/A N/A N/A N/A N/A 4 SU 3,050 6,998 17,584 28,000 N/A N/A N/A N/A N/A N/A N/A N/A N/A 6 SU 2,522 5,802 14,170 26,713 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 8 SU 2,419 5,278 12,881 24,443 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 12 SU 1,696 3,899 9,444 18,048 N/A 28,000 N/A N/A N/A N/A N/A N/A N/A 18 SU N/A N/A N/A 10,069 N/A 17,289 23,123 28,000 N/A N/A N/A N/A N/A 24 SU N/A N/A N/A 9,097 N/A 15,669 20,392 28,000 N/A N/A N/A N/A N/A 18 MU N/A N/A N/A N/A 4,679 8,067 10,988 17,918 19,605 26,276 28,000 N/A N/A 24 MU N/A N/A N/A N/A 3,302 6,181 7,968 13,027 14,803 19,637 25,652 28,000 N/A 36 MU N/A N/A N/A N/A 2,845 4,772 6,385 10,820 12,337 16,589 21,158 26,779 28,000 48 MU N/A N/A N/A N/A 2,408 4,023 5,437 8,924 10,466 13,975 18,181 23,227 28,000 60 MU N/A N/A N/A N/A 1,745 3,193 3,982 6,878 7,926 10,562 13,478 16,872 20,721 72 MU N/A N/A N/A N/A 1,461 2,657 3,313 5,488 6,408 8,461 11,067 14,307 17,888 96 MU N/A N/A N/A N/A N/A 1,717 2,208 3,921 4,328 5,874 7,500 9,459 11,621 144 MU N/A N/A N/A N/A N/A 1,612 2,104 3,387 3,757 4,998 6,483 8,484 10,545 F71 Reel Weights subject to change without notice.
Fiber Optic Cable Packaging and Shipping Information Riser, Plenum and LSZH* Simplex (SP) Cables Fiber Size 18x12x12 22x12x12 30x12x12 FT FT FT 1 1.6 19,602 28,000 N/A 1 2.0 14,364 28,000 N/A 1 2.5 9,363 20,848 28,000 1 2.9 6,897 15,824 28,000 * LSZH is only for the 2.5 and 2.9 cables. Riser, Plenum and LSZH* Zipcord (ZC) Cables Fiber Size 24 x 12 x 19.25 35 x 16.5 x 18 FT FT 2 1.6 28,000 N/A 2 2.0 28,000 N/A 2 2.5 21,983 28,000 2 2.9 15,965 28,000 * LSZH is only for the 2.5 and 2.9 cables. Riser, Plenum and LSZH* Interconnect (IC) Cables Fiber Size 18x12x12 22x12x12 30x12x12 FT FT FT 2 2.9 6,897 15,824 28,000 All reels calculated using 2 flange clearance Reel Weights subject to change without notice. F72
Fiber Optic Cable Packaging and Shipping Information International Packaging - Weights and Dimensions Reel Dimensions Reels per Layer Layers Cube Size (in.) (l x w x h) Lagging Weight (lbs.) Reel Weight (lbs.) Pallet Weight (lbs.) Total Weight (lbs.) 18 x 12 x 12 5 1 44 x 44 x19 N/A 10 32 82 18 x 12 x 12 5 2 44 x 44 x 32 N/A 10 32 132 18 x 12 x 12 5 3 44 x 44 x 45 N/A 10 32 182 18 x 12 x 12 4 1 36 x 36 x 19 N/A 10 23 63 18 x 12 x 12 4 2 36 x36 x 32 N/A 10 23 103 18 x 12 x 12 4 3 36 x 36 x 45 N/A 10 23 143 22 x 12 x 12 4 1 44 x 44 x 19.25 N/A 12 32 80 22 x 12 x 12 4 2 44 x 44 x 32.5 N/A 12 32 128 22 x 12 x 12 4 3 44 x 44 x 45.75 N/A 12 32 176 24 x 12 x 19.25 1 1 36 X 24 X 30 N/A 17 32 49 30 x 12 x 12 1 1 42 x 42 x 19.25 N/A 22 30 52 35 x 16.5 x 18.5 1 N/A 39 X 25 X 41 60 70 36 166 42 x 22 x 29.75 1 N/A 44 X 40 X 52 189 118 43 350 42 x 24 x 24 1 N/A 44 X 33 X 52 189 109 41 339 48 x 22 x 32.5 1 N/A 51 x 42 x 58 169 140 78 387 54 x 24 x 28 1 N/A 57 x 42 x 64 188 350 78 616 60 x 30 x 32 1 N/A 63 X 45 X 70 215 433 138 786 66 x 30 x 32 1 N/A 69 X 45 X 75 241 580 138 959 72 x 36 x 36 1 N/A 75 X 48 X 82 333 627 197 1157 78 x 36 x 36 1 N/A 81 x 48 x 88 360 758 197 1315 84 x 40 x 40 1 N/A 85 x 52 x 92 387 850 210 1447 88 x40 x 40 1 N/A 91 x 52 x 97 414 958 210 1582 96 x 44 x 40 1 N/A not palletized 450 1125 0 1575 NOTE: Units per container can be limited due to product weight F73 Reel Weights subject to change without notice.